• 제목/요약/키워드: Electric Compressor

검색결과 140건 처리시간 0.029초

철도차량 제동기의 압력제어에 관한 연구 (A Study on Pressure Control Method of Train Brake System)

  • 이한민;김길동;박성환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1909-1915
    • /
    • 2008
  • The brake systems of the rolling stocks are generally consisted of electrical and mechanical brake systems. Because of its inherent structure of the each brake system, the electrical brake system is mainly used at the high speed range while the mechanical brake system is used at the relatively lower speed range. It is desirable for the rolling stocks to apply the entire electrical brake system. However, since the brake force from electric brake system is not enough to stop the rolling stock within the legal stop distance. Therefore, the mechanical brake system is indispensable to rolling stocks. In general, the vast majority of the world trains are equipped with mechanical braking systems which use compressed air as the force to push block on to wheels or pads on to discs. These mechanical systems are known as air brake or pneumatic brakes. For the air brake system, basically huge scale air compressor is equipped and the long pipe line is complexively connected. Since mass of these air brake components, it is difficult to be a light weight equipment and the long pipe line raise the maintenance problem. In order to overcome these problems of air brake system, the hydraulic brake system is proposed in this research. The hydraulic brake system makes the whole weight of brake equipment be light and large braking force can be applied. Therefore, in this research, the validity and advantages of applying the hydraulic brake system are reviewed.

  • PDF

화력발전소 흡입필터 세정용 급속 배기 밸브의 개발 (Development of the Quick Exhaust Valve to Blowing the Intake Filter for the Thermal Power Plant)

  • 정찬세;이형욱;정영만;이창돈;양순용
    • 한국생산제조학회지
    • /
    • 제19권4호
    • /
    • pp.548-552
    • /
    • 2010
  • The air suction filter of the power plant decrease the dust and impurities of suction air that reduce the life and efficiency of the boiler. The suction efficiency of the air filter falls with the dust and impurities when the time of use comes to be long. Therefore, the various contaminant of the filter must remove periodically. This paper presents a developed quick exhaust valve to use in the thermo-electric power plant. to removing contaminants on the filter, the blowing is done shortly by air pressure. The Air flowed out to the out side from the inside of the filter. The performance test of the developed valve is done by making a test-bench according to JIS and KS standards. The efficiency is found higher than the existing related valve.

무공해 자동차용 수열원 히트펌프 시스템의 난방 성능에 관한 실험적 연구 (An Experimental Study on the Heating Performance of Coolant Heat Source Heat Pump System for Zero Emission Vehicles)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제22권7호
    • /
    • pp.57-62
    • /
    • 2014
  • This study presented the feasibility of a coolant heat-source heat pump system as an alternative heating system for electrically driven vehicles. Heat pumps are among the most environmentally friendly and efficient heating technologies in residential buildings. In various countries, electric mobiles devices such as EV, PHEV, and FCEV, have been mainly concerned with heat pumps for new mobile markets. The experiments herein were conducted for various ambient temperatures and coolant temperatures to reflect the winter season. The system, a coolant heat-source heat pump, consisted of an inside heat exchanger, an outside heat exchanger, a motor driven compressor, an electronic expansion valve, and plumbing parts. For the experimental results, the maximum heating capacity and air discharge temperature are up to 6.3 kW and $62^{\circ}C$ respectively at an ambient temperature of $10^{\circ}C$, and coolant at $10^{\circ}C$. However, at $-20^{\circ}C$ ambient temperature and $-10^{\circ}C$ coolant temperature, conditions were insufficient to warm the cabin as the air discharge temperature was $13^{\circ}C$.

A STUDY ON THE EXPLOSION SAFETY ASSESSMENT OF HYDROCARBON REFRIGERANT REFRIGERATOR

  • Oh, Kyu-Hyung;Kim, Min-Kyu;Chu, Euy-Sung;Lim, Byung-Han;Kim, Man-Hoe;Park, Yoon-Ser
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.289-296
    • /
    • 1997
  • This paper discribes an experimental explosion risk assessment study on refrigerators containing flammable hydrocarbon refrigerant. A refrigerator used in this study is a larder fridge type, 215 liter in volume. The hydrocarbon refrigerant used in the refrigerator is iso-butane(C$_4$H$_{10}$). For the explosion safety assessment of the refrigerator, temperature of compressor, cooling air circulation fan motor, defrost heater and inner lamp were measured during the operation. And to confirm the ignitablity of flammable gas by the electric spark of the switches of the refrigerator, ON-OFF test of all switches were conducted with compulsorily near the stoichiometric concentration atmosphere of iso-butane-air mixture. As the result of experiment above mentioned and another experiment for the explosion safety assessment, we can conclude that explosion hazard in connection with the use of hydrocarbon refrigerant was few.w.

  • PDF

주위온도조건이 스터링 극저온냉동기의 성능에 미치는 영향 (Effects of the environmental temperature on the performance of the Stirling cryocooler)

  • 홍용주;김효봉;박성제
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.65-68
    • /
    • 2009
  • The Stirling cryocoolers have been widely used for the cooling of the infrared detector(InSb, HgCdTe, and etc,) and HTS(High Temperature Superconductor) to the cryogenic temperature. The monobloc Stirling cryocoolers with the rotary compressor are applicable to the cooling device for the compact mobile thermal imaging system, because the cryocoolers have the compact structure and light weight. The typical performance factors of the Stirling cryocooler are the cool-down time, cooling capacity at the desired temperature (80 K), the electric input power and COP. The above performance factors depend on the operating conditions such as the charging pressure of the helium gas, the thermal environment and etc.. In this study, the effects of the thermal environment (temperature of 241, 293, and 333 K) on the performance of the cryocooler were investigated by experiments. The results show the effects of the temperature of the thermal environment on the cooling capacity and input power.

화재사례 및 재현실험을 통한 온도조절장치 고장 및 오동작으로 인한 전자제품 화재 메커니즘 분석 (A Study on the Analysis of Fire Mechanisms in Electronic Products due to Failure and Malfunction of Thermostats Through Fire Cases and Reproduction Experiments)

  • 이정일;임종화
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.31-38
    • /
    • 2024
  • In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.

시설풋고추 재배에서의 지중관수 및 공기주입 효과 (Effects of Subsurface Drip Irrigation and Aeration in Green Pepper Cultivation)

  • 권준국;강남준;조명환;강윤임;박경섭;이재한
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.225-231
    • /
    • 2009
  • 지표관수와 비교하여 지중관수 및 지중관수 시 공기주입의 효과를 검토하고자 '녹광' 풋고추를 온실 내에서 토양재배(silty loam)하여 관수효율, 토양특성, 과실 생육 및 수량 등을 조사하였다. 관수방법은 관수호스를 이랑당 2열 배열하되 지표관수는 토양표면, 지중관수는 지표 20cm 아래에 설치하였고, 공기주입은 air compressor를 이용하여 낮 동안에 시간당 3분간 주입하였다. 관수는 콘트롤러, 전자식 토양수분장력센서 등을 이용, 토양수분에 기초한 자동관수를 실시하였는데, 관수개시점은 -20kPa, 관수종료점을 -10kPa로 설정하여 관리하였다. 그 결과, 토양수분의 감소속도가 지표 관수에 비해 지중관수와 지중관수 +공기주입이 늦었으며, 관수량도 지중관수가 지표환수에 비해 지표면에서의 증발 감소 등으로 약 30% 적었다. 표토층의 EC 및 무기이온함량은 지표관수에 비해 지중관수나 지중관수 +공기주입이 낮은 수준이었다. 뿌리의 발달은 지표관수에 비해 지중관수+공기주입한 것이 가장 좋았는데, 특히 뿌리가 길고 세근의 발달이 많았다. 이로 인해 풋고추 수량이 지표관수에 비해 지중관수가 22%, 지중관수 +공기주입이 30% 각각 증가되었다.

고속철도차량의 EMB 적용을 위한 3상 IPMSM의 설계 및 제동압부력 제어 (A Design Method of Three-phase IPMSM and Clamping Force Control of EMB for High-speed Train)

  • 백승구;오혁근;곽민호;김석원
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.578-585
    • /
    • 2018
  • 본 논문은 고속철도차량에 전기기계제동장치(EMB : Electric Mechanical Brake)를 적용하기 위한 주요 구성품인 3상 매입형영구자석동기전동기(IPMSM : Interior Permanent Magnet Synchronous Motor)의 설계방법과 이를 이용한 인버터 제어시스템의 압부력제어 시뮬레이션 방법을 제안한다. 최근 자동차에서 주로 사용하는 유압식 제동장치는 유압을 발생시키기 위해 필요한 오일류와 유압 라인의 관리, 유지보수성 및 유압펌프의 동작으로 인한 효율성 등이 문제로 제기되면서 EMB에 대한 관심이 높아지고 있으나 비용증가 및 안전측면의 보완이 지속적으로 요구되고 있다. 공압식 제동장치를 주로 사용하는 철도차량은 EMB 시스템을 적용할 경우 차량 하부에 큰 공간을 차지하는 공기압축기, 제동공기통 및 연결 배관 등의 부품이 필요하지 않으므로 50% 이상의 소형화가 가능하며 인버터를 적용한 전동기 구동방식으로 인하여 상대적으로 빠른 응답속도와 정밀제어를 통해 공주거리를 단축시킬 수 있는 장점을 갖는다. 또한, 철도차량은 다수의 제동장치가 제동력을 분담하는 구조로 설계되어 자동차와 비교하여 EMB 적용이 안전측면에서 유리하다. 본 논문에서는 JMAG을 활용하여 고속철도의 제동 캘리퍼와 제동력 출력에 적합한 모터설계 및 전자계해석을 수행하였다. 제동 압부력 제어 시뮬레이션을 위해 기계구동부는 기존 EMB 시스템에 주로 적용된 볼스크류 형태의 동작방식과는 달리 고속철도차량에 적용된 편심축 회전을 이용한 구동방식으로 모델링하였다. IPMSM 제어를 통한 제동압부력 및 제동력 출력결과는 Matlab/Simulink를 활용하여 JMAG의 IPMSM 모델과 co-simulation을 통해 보였으며 결과의 타당성은 차세대고속철도(HEMU-430X)의 제동사양과의 비교를 통해 검증하였다.

An experimental study on the cooling performance and the phase shift between piston and displacer in the Stirling cryocooler

  • Park, S. J.;Y. J. Hong;Kim, H. B.;D. Y. Koh;B. K. Yu;Lee, K. B.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.111-117
    • /
    • 2003
  • In the design of the split type free displacer Stilting cryocooler the motion of the displacer is very important to decide the cooling capacity, which depends upon the working gas pressure, the swept volume in the compression space and the expansion space, operating frequency, the phase shift between piston and displacer, etc. In this study, Stirling cryocooler actuated by the electric farce of the dual linear motor is designed and manufactured. Cool down characteristics of the cold end with laser displacement sensor in the expander of the Stilting cryocooler is evaluated. The charging pressure was 15kg$_{f}$/$\textrm{cm}^2$ and operating frequency was 50Hz. Input power and the lowest temperature were about 32W and 67K, respectively. And, displacement of the piston is measured by LVDTs (Linear Variable Differential Transformers), displacement of thedisplacer is measured by laser optic method, and phase shift between piston and displacer is discussed. As the peak-to-peak pressure of the compressor was increased, peak-to-peak displacement of the displacer was increased. The peak-to-peak displacement of the displacer increases in the range of 0 - 64.5Hz(resonant frequency of the displacer), but decreases steeply when the operating frequency is bigger than the resonant frequency. Finally when the phase shift between displacements of the Piston and displacer is 45。, operating frequency is optimum and is decided by resonant frequency of the expander, mass and cross section area of the displacer and constant by friction and flow resistance.e.

초전도 전력 케이블 냉각 시스템 적용을 위한 극저온 터보 팽창기 설계 및 해석 (Design and Analysis of Cryogenic Turbo Expander for HTS Power Cable Refrigeration System)

  • 이창형;김동민;양형석;김석호
    • 한국기계가공학회지
    • /
    • 제14권3호
    • /
    • pp.141-148
    • /
    • 2015
  • The cryogenic cooling system should maintain the HTS power cable below 77 K. As the length of HTS power cables has increased, there have been many efforts to develop large capacity cryocoolers. Brayton, Joule-Thomson, and Claude refrigerators were considered for the large capacity cryocooler. Among the various cryocoolers, the Brayton refrigerator is the most competitive in terms of the HTS power cable. At present, it is thought that a 10-kW class refrigerator will be able to be used as a unit cooling system for the commercialization of HTS power cables in the near future. The Brayton refrigerator is composed of recuperative heat exchangers, a compressor, and a cryogenic turbo expander. Among the various components, the cryogenic turbo expander is the part that decreases the temperature, and it is the most significant component that is closely related with overall system efficiency. It rotates at high speed using high-pressure helium or neon gas at cryogenic temperatures. This paper describes the design of a 300-W class Brayton refrigeration cycle and the cryogenic turbo expander as a downscale model for the practical 10-kW class cycle. Flow and structural analyses are performed on the rotating impeller and nozzle to verify the efficiency and the design performance.