• 제목/요약/키워드: Efficient lamp

검색결과 117건 처리시간 0.023초

미세 선가공을 위한 레이저 변수 제어 (Control of Laser Parameter for Precision Line Processing)

  • 김영섭;최은서;신용진
    • 한국레이저가공학회지
    • /
    • 제10권1호
    • /
    • pp.11-17
    • /
    • 2007
  • We presented the proper laser processing conditions for the capillary line marking, which could be applied for the fabrication of injection needles. With changing the parameters such as lamp current, duty cycle and beam amplification factor of beam expander, we evaluated the processing performance considering amount of dross, processing efficiency and processed linewidth in the sample. We could carry out the proper line marking at the condition of 70% lamp current, duty cycle of 7-10% and 6-times amplification of beam diameter. To perform efficient line processing, the utilization of duty cycle of 12% at 80% lamp current was also preferred.

  • PDF

Ar 가스 압력과 RF 전력변화에 따른 유도결합형ㆍ플라즈마 E-H모드 변환의 광학적 특성 (Optical E-H Transition Properties of Inductively Coupled Plasma with Ar Gas Pressure and RF Pourer)

  • 허인성;조주웅;이영환;김광수;최용성;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권1호
    • /
    • pp.20-23
    • /
    • 2004
  • In this paper, the emission properties of electrodeless fluorescent lamp were discussed using the inductively coupled plasma. To transmit the electromagnetic energy into the chamber, a RF power of 13.56 [MHz] was applied to the antenna and considering the Ar gas pressure and the RF electric power change, the emission spectrum, Ar I line, luminance were investigated. At this time, the input parameter for ICP RF plasma, Ar gas pressure and RF power were applied in the range of 10∼60 [mTorr], 10∼300 [W], respectively. From emission intensity and lumnance intensity results, the mode transition from E-mode to H-mode was observed. This implies that this method can be used to find an optimal RF power for efficient light illumination in an electrodeless fluorescent lamp.

제논 혼합가스를 이용한 고효율 면광원과 국부적 밝기 제어 방식 (High Luminous Efficiency Flat Light Source with Xe mixture Gas Discharge and Areal Brightness Control Method)

  • 정재철;서인우;오병주;황기웅
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.153-157
    • /
    • 2009
  • A Highly efficient Mercury-free Flat Fluorescent Lamp (MFFL) with dielectric barrier Xe gas discharge was developed for an alternative of conventional line-type Cold Cathode Fluorescent Lamps (CCFLs) which shows a wide voltage margin and a stable discharge operation for diffuse glow discharge with an application of a auxiliary electrode. Electro-optic characteristics of the MFFL were examined through the changes in ambient temperature, total pressure and Xe partial pressure. the single cell is expanded into a multi-structured configuration to realize a large sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive brightness control using dual auxiliary electrodes and bi-polar drive scheme. In addition, interesting application of this ultra high luminance flat lamp by the optimization of the gas condition and the pattern of the rear phosphor layer is suggested as a good alternative of daylight lamp source

  • PDF

기상예보를 이용한 태양광 LED 가로등의 효율적 운용에 관한 연구 (A Study on Efficient Management of Solar Powered LED Street Lamp Using Weather forecast)

  • 표세영;권오석;김기환
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권2호
    • /
    • pp.129-135
    • /
    • 2015
  • 본 논문에서는 가로등 운용에 있어서 일기예보 및 일조량을 고려한 알고리즘을 제안하였다. 이 알고리즘에 의해 생성된 Weather Factor를 적용하여 보행자가 있을 시에는 가로등의 광량을 최대로 유지하고 보행자가 없을 경우 최대전력을 사용하지 않고 일정한 밝기를 유지하는 대기전력모드를 사용하여 전력소비를 줄였다. 이렇게 함으로써 배터리의 잔량을 확보할 수 있으며 이를 이용하여 부조일이 지속될 경우 운용일수를 최대한 연장하기 위한 적절한 알고리즘을 제안하였다. 또한 이러한 알고리즘에 필요한 Weather Factor의 값을 실험을 통하여 결정하였으며. 모의실험을 통해 알고리즘의 적합성을 확인하였다.

확산형 LED램프와 백열램프의 각도별 광속에 관한 비교연구 (A Comparative Study on the Luminous Flux by Degree of Non-directional LED Lamps and Incandescent lamp)

  • 박창용;서정현
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.32-39
    • /
    • 2014
  • In general, non-directional LED lamps including high transmittance cover are more advantageous than directional LED lamps, which are efficient enough to improve luminous efficacy and obtain certification, allowing wide manufacture, sale, and distribution. Although KS C 7651(Self-ballasted LED lamps-Safety and performance requirements) was revised in July 2013, however, many companies are having a lot of difficulties in keeping the certification and product development for the lack of the photometric analysis for non-directional LED lamps. In this paper, through the measurement of the angular distribution of luminous flux of incandescent lamp and non-directional LED lamps, we examined the reasonability of non-directional LED lamps' standards as suggested in KS C 7651. According to the results, even if non-directional LED lamps satisfy KS C 7651, when compared to an incandescent lamp, they showed less diffusive than the incandescent lamp and the distribution of the luminous flux depending on the angle fluctuated greatly even among LED lamps. Judging by the result, the current standard of the non-directional LED lamps, KS C 7651, has been comprehended that the angular distribution of the luminous flux needs to be presented after being much more thoroughly standardized.

RF통신을 이용한 LED 조명의 온도제어 (Temperature Control for LED Lamps Using RF Communication)

  • 최형식;신희영;오지윤;이상섭
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.759-765
    • /
    • 2012
  • In this paper, a temperature control for LED (light emitting diode) lamp using a cooling fan is studied. An efficient temperature control scheme for the LED lamp using the fan wind at the lowest sound noise is studied. For the study, after measurement of the minimum sound noise of the fan and related temperature of the LED lamp through tests, experiments on temperature control of the LED lamp using the fan with various size of heat sinks was performed. To reduce the fan sound noise, a method of reducing the operation time with optimal size of the heat sink was studied. Also, a control of LED lamps using RF communication was studied.

Rapid and Sensitive Detection of Lettuce Necrotic Yellows Virus and Cucumber Mosaic Virus Infecting Lettuce (Lactuca sativa L.) by Reverse Transcription Loop-Mediated Isothermal Amplification

  • Zhang, Yubao;Xie, Zhongkui;Fletcher, John D;Wang, Yajun;Wang, Ruoyu;Guo, Zhihong;He, Yuhui
    • The Plant Pathology Journal
    • /
    • 제36권1호
    • /
    • pp.76-86
    • /
    • 2020
  • Cucumber mosaic virus (CMV) is damaging to the growth and quality of lettuce crops in Lanzhou, China. Recently, however, for the first time an isolate of lettuce necrotic yellows virus (LNYV) has been detected in lettuce crops in China, and there is concern that this virus may also pose a threat to lettuce production in China. Consequently, there is a need to develop a rapid and efficient detection method to accurately identify LNYV and CMV infections and help limit their spread. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays were developed to detect the nucleoprotein (N) and coat protein (CP) genes of LNYV and CMV, respectively. RT-LAMP amplification products were visually assessed in reaction tubes separately using green fluorescence and gel electrophoresis. The assays successfully detected both viruses in infected plants without cross reactivity recorded from either CMV or LNYV or four other related plant viruses. Optimum LAMP reactions were conducted in betaine-free media with 6 mM Mg2+ at 65℃ for LNYV and 60℃ for 60 min for CMV, respectively. The detection limit was 3.5 pg/ml and 20 fg/ml using RT-LAMP for LNYV and CMV plasmids, respectively. Detection sensitivity for both RT-LAMP assays was greater by a factor of 100 compared to the conventional reverse transcription polymerase chain reaction assays. This rapid, specific, and sensitive technique should be more widely applied due to its low cost and minimal equipment requirements.

Loop-mediated Isothermal Amplification assay for Detection of Candidatus Liberibacter Asiaticus, a Causal Agent of Citrus Huanglongbing

  • Choi, Cheol Woo;Hyun, Jae Wook;Hwang, Rok Yeon;Powell, Charles A
    • The Plant Pathology Journal
    • /
    • 제34권6호
    • /
    • pp.499-505
    • /
    • 2018
  • Huanglongbing (HLB, Citrus greening disease) is one of the most devastating diseases that threaten citrus production worldwide. Although HLB presents systemically, low titer and uneven distribution of these bacteria within infected plants can make reliable detection difficult. It was known loop-mediated isothermal amplification (LAMP) method has the advantages of being highly specific, rapid, efficient, and laborsaving for detection of plant pathogens. We developed a new LAMP method targeting gene contained tandem repeat for more rapid and sensitive detection of Candidatus Liberibacter asiaticus (CLas), putative causal agent of the citrus huanglongbing. This new LAMP method was 10 folds more sensitive than conventional PCR in detecting the HLB pathogen and similar to that of real-time PCR in visual detection assay by adding SYBR Green I to mixture and 1% agarose gel electrophoresis. Positive reactions were achieved in reaction temperature 57, 60 and $62^{\circ}C$ but not $65^{\circ}C$. Although this LAMP method was not more sensitive than real-time PCR, it does not require a thermocycler for amplification or agarose gel electrophoresis for resolution. Thus, we expect that this LAMP method shows strong promise as a reliable, rapid, and cost-effective method of detecting the CLas in citrus and can be applied for rapid diagnosis is needed.

디지털제어방식을 이용한 자동차용 고압방전등 안정기의 조광제어 (Dimming Control of A Automotive HID Lamp Ballast Using Digital Control Method)

  • 이재학;김윤호
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.24-33
    • /
    • 2005
  • 본 논문은 디지털제어방식을 이용한 자동차용 35[W]급 메탈핼라이드 램프용 전자식 안정기의 고효율 조광제어 시스템을 구현하였다. 본 논문에서는 밝기, 연색성, 광효율, 수명 등에서 기존의 할로겐 램프에 비해 우수한 특성을 가지고 있지만 복잡한 과도특성을 가지고 있는 메탈핼라이드 램프를 자동차에 적용하기 위해 디지털 제어방식을 전자식 안정기에 적용하여 램프 요구조건 및 주변 환경에 최적으로 적용할 수 있도록 전자식 안정기를 설계하였다. 또한, 주변의 빛의 세기에 따라 램프의 양단전압을 단계별로 가변 제어하는 조광시스템을 구현하여, 운전자에게는 보다 효율적인 운전여건을 만듬과 동시에 한정된 에너지를 가진 밧데리로 운전하는 자동차에서 효율적인 전력제어를 실현하였다. 개발된 안정기에 대한 동작특성을 시뮬레이션과 실험을 통해 확인하였다.

펄스 UV 램프를 이용한 미생물 소독 및 2-MIB 제거 특성 (Characteristics of Disinfection and Removal of 2-MIB Using Pulse UV Lamp)

  • 안영석;양동진;채선하;임재림;이경혁
    • 상하수도학회지
    • /
    • 제23권1호
    • /
    • pp.69-75
    • /
    • 2009
  • The characteristics of disinfection and organic removal were investigated with pulse UV lamp in this study. The intensity and emission wavelength of pulse UV Lamp were compared with low pressure UV lamp. The emission spectrum range of pulse UV lamp was between 200 and 400 nm while the emission spectrum of low pressure UV lamp was only single wavelength of 254nm. 3 Log inactivation rate of B. subtilis spore by pulse UV and low pressure UV irradiation was determined as $44.71mJ/cm^2$ and $57.7mJ/cm^2$, respectively. This results implied that wide range of emission spectrum is more effective compared to single wavelength emission at 254nm. 500ng/L of initial 2-MIB concentration was investigated on the removal efficiency by UV only and $UV/H_2O_2$ process. The removal efficiency of UV only process achieved approximately 80% at $8,600mJ/cm^2$ dose. 2-MIB removal rate of $UV/H_2O_2$ (5 mg/L $H_2O_2$) process was 25 times increased compared to UV only process. DOC removal efficiency for the water treatment plant effluent was examined. The removal efficiency of DOC by UV and $UV/H_2O_2$ was no more than 20%. Removal efficiency of THMFP(Trihalomethane Formation Potential), one of the chlorination disinfection by-products, is determined on the UV irradiation and $UV/H_2O_2$ process. Maximum removal efficiency of THMFP was approximately 23%. This result indicates that more stable chemical structures of NOM(Natural Organic Matter) than low molecule compounds such as 2-MIB, hydrogen peroxide and other pollutants affect low removal efficiency for UV photolysis. Consequently, pulse UV lamp is more efficient compared to low pressure lamp in terms of disinfection due to it's broad wavelength emission of UV. Additional effect of pulse UV is to take place the reactions of both direct photolysis to remove micro organics and disinfection simultaneously. It is also expected that hydrogen peroxide enable to enhance the oxidation efficiency on the pulse UV irradiation due to formation of OH radical.