• 제목/요약/키워드: Efficient Energy Use

검색결과 849건 처리시간 0.033초

우주법(宇宙法)의 최근동향(最近動向) (Recent Developments in Space Law)

  • 최준선
    • 항공우주정책ㆍ법학회지
    • /
    • 제1권
    • /
    • pp.223-243
    • /
    • 1989
  • The practical application of modern space science and technology have resulted in many actual and potential gains of mankind. These successes have conditioned and increased the need for a viable space law regime and the challenge of space has ultimately led to the formation of an international legal regime for space. Space law is no longer a primitive law. It is a modern law. Yet, in its stages of growth, it has not reached the condition of perfection. Therefore, under the existing state of thing, we could carefully say that the space law is one of the most newest fields of jurisprudence despite the fact that no one has so far defined it perfectly. However, if space law can be a true jurisprudential entity, it must be definable. In defining the space law, first of all, the grasp of it's nature iis inevitable. Although space law encompasses many tenets and facets of other legal discriplines, its principal nature is public international law, because space law affects and effects law relating intercourse among nations. Since early 1960s when mankind was first able to flight and stay in outer space, the necessity to control and administrate the space activities of human beings has growingly increased. The leading law-formulating agency to this purpose is the United Nation's ad hoc Committee on Peaceful Uses of Outer Space("COPUOS"). COPUOS gave direction to public international space law by establishing the 1963 Declaration of Legal Principles Governing the Activities of the States in the Exploration and Use of Outer Space("1963 Declaration"). The 1963 Declaration is very foundation of the five international multilateral treaties that were established successively after the 1963 Declaration. The five treaties are as follows: 1) The Treaty on Principles Governing the Activities of States in the Exploration and Use of Outer Space including Moon and other Celestial Bodies, 1967. 2) The Agreement on the Rescue of Astronauts, the Return of Astronauts, and the Return of Objects Launched into Outer Space, 1968. 3) The Convention on International Liability for Damage Caused by Space Objects, 1972. 4) The Convention on Registration of Objects Launched into Outer Space, 1974. 5) The Agreement Governing Activities of States on the Moon and Other Celestial Bodies: Moon Treaty, 1979. The other face of space law is it's commercial aspect. Space is no longer the sole domination of governments. Many private enterprise have already moved directly or indirectly into space activities in the parts such as telecommunications and space manufacturing. Since space law as the public international law has already advanced in accordance with the developments of space science and technology, there left only a few areas untouched in this field of law. Therefore the possibility of rapid growth of space law is expected in the parts of commerical space law, as it is, at this time, in a nascent state. The resources of the space environment are also commercially both valuable and important since the resources include the tangible natural resources to be found on the moon and other celestial bodies. Other space-based resources are solar energy, geostationary and geosynchronous orbital positions, radio frequencies, area possibly suited to human habitations, all areas and materials lending themselves to scientific research and inquiry. Remote sensing, space manufacturing and space transportation services are also another potential areas in which commercial. endeavors of Mankind can be carried out. In this regard, space insurance is also one of the most important devices allowing mankind to proceed with commercial space venture. Thus, knowlege of how space insurance came into existence and what it covers is necessary to understand the legal issues peculiar to space law. As a conclusion the writer emphasized the international cooperation of all nations in space activities of mankind, because space commerce, by its nature, will give rise many legal issues of international scope and concern. Important national and world-community interests would be served over time through the acceptance of new international agreements relating to remote sencing, direct television broadcasting, the use of nuclear power sources in space, the regularization of the activities of space transportation systems. standards respecting contamination and pollution, and a practical boundary between outer space and air space. If space activity regulation does not move beyond the national level, the peaceful exploration of space for all mankind will not be realized. For the efficient regulation on private and governmental space activities, the creation of an international space agency, similar to the International Civil Aviation Organization but modified to meet the needs of space technology, will be required. But prior to creation of an international organization, it will be necessary to establish, at national level, the Office of Air and Space Bureau, which will administrate liscence liscence application process, safety review and sale of launch equipment, and will carry out launch service.

  • PDF

EDXRF에 의한 용접흄 중의 중금속의 비파괴 정량 (The Non-Destructive Determination of Heavy Metals in Welding Fume by EDXRF)

  • 박승현;정지연;유장진;이나루;유일재;송경석;이용학;한정희;김성진;박정선;정호근
    • 한국산업보건학회지
    • /
    • 제11권3호
    • /
    • pp.229-234
    • /
    • 2001
  • The EDXRF(Energy Dispersive X-ray Fluorescence Spectrometer) technique was applied to the determination of heavy metals in welding fume. The EDXRF method designed in this study was a non-destructive analysis method. Samples were analyzed directly by EDXRF without any pre-treatment such as digestion and dilution. The samples used to evaluate this method were laboratory samples exposed in a chamber connected with a welding fume generator. The samples were first analyzed using a non-destructive EDXRF method. The samples subsequently were analyzed using AAS method to verify accuray of the EDXRF method. The purpose of this study was to evaluate the possibility of the non-destructive analysis of heavy metals in welding fume by EDXRF. The results of this study were as follow: 1.When the samples were collected under the open-face sampling condition, a surface distribution of welding fume particles on sample filters was uniform, which made non-destructive analysis possible. 2. The method was statistically evaluated according to the NIOSH(National Institute for Occupational Safety and Health) and HSE(Health and Safety Executive) method. 3. The overall precision of the EDXRF method Was calculated at 3.45 % for Cr, 2.57 % for Fe and 3.78 % for Mn as relative standard deviation(RSD), respectively. The limits of detection were calculated at $0.46{\mu}g$/sample for Cr, $0.20{\mu}g$/sample for Fe and $1.14{\mu}g$/sample for Mn, respectively. 4. A comparison between the results of Cr, Fe, Mn analyzed by EDXRF and AAS was made in order to assess the accuracy of EDXRF method. The correlation coefficient between the results of EDXRF and AAS was 0.9985 for Cr, 0.9995 for Fe and 0.9982 for Mn, respectively. The overall uncertainty was determined to be ${\pm}12.31%$, 8.64 % and 11.91 % for Cr, Fe and Mn, respectively. In conclusion, this study showed that Cr, Fe, Mn in welding fume were successfully analyzed by the EDXRF without any sample pre-treatment such as digestion and dilution and a good correlation between the results of EDXRF and AAS was obtained. It was thus possible to use the EDXRF technique as an analysis method of working environment samples. The EDXRF method was an efficient method in a non-destructive analysis of heavy metals in welding fume.

  • PDF

장기간 SPOT/VEGETATION 정규화 식생지수를 이용한 지면 변화 탐지 개선에 관한 연구 (The Study of Land Surface Change Detection Using Long-Term SPOT/VEGETATION)

  • 염종민;한경수;김인환
    • 한국지리정보학회지
    • /
    • 제13권4호
    • /
    • pp.111-124
    • /
    • 2010
  • 지표면의 환경변화를 관측하는 것은 토지사용과 기후변화, 기상연구, 농업, 지표면의 에너지 균형 및 환경시스템에 매우 중요한 연구로 이용되어지고 있다. 최근 위성영상을 이용한 변화탐지는 국지 단위 환경변화 탐지를 위해 그 필요성이 높아지고 있는 실정이며, 특히 잦은 개발과 변화로 주기적인 탐지가 필요한 도심지역의 변화탐지는 국토환경변화 및 지역계획 연구에 대한 효율적인 의사결정 지원이 가능하므로 그 활용성이 매우 높아지고 있다. 이러한 배경으로, 위성 영상을 이용한 원격탐사 자료를 활용한 분석은 비교적 짧은 시간에 광범위한 지역의 영상 정보를 취득할 수 있기 때문에 국토 환경변화 관리 분야에서의 적용 가능성이 높다. 본 연구에서는 인공위성 자료를 활용하여 변화탐지를 수행할 때 공간정보 추출의 정확성을 높이는 기술 개발을 위해 시계열자료의 통계적 분석을 통한 변화탐지기법 개발을 수행하였다. 전처리된 자료를 이용하여 정규화 식생지수를 산출하고 K-mean clustering 무감독 분류를 통해 처리된 데이터를 연구영역의 10년간 자료를 이용한 평균 정규화 식생지수 값과 표준편차 값을 계산하여 각각의 화소별 상대적인 변화량을 측정하여 변화 정도를 탐지하였다. 일반적으로 변화 탐지 수행 시, 태양광 채널을 이용할 경우 기하학적 특성에 의해 발생하는 방향성 효과를 보정하여야 한다. 본 연구에서는 대기 보정과 방향성 보정이 수행된 중 저해상도 정규화 식생지수를 이용하여 객관적인 변화 임계치 값을 결정하였다. 연구결과 반사도 값의 차이를 이용한 변화탐지보다 객관적이고 명확하게 변화지역을 탐지할 수 있었다.

밭 작물(作物)의 가리(加里) 생리(生理) (Potassium Physiology of Upland Crops)

  • 박훈
    • 한국토양비료학회지
    • /
    • 제10권3호
    • /
    • pp.103-134
    • /
    • 1977
  • 밭 작물에 대(對)한 칼리의 생리(生理) 및 생화학적(生化學的) 역할(役割)을 최근(最近) 연구결과(硏究結果)를 중심(中心)으로 검토(檢討)하였으며 우리나라 밭 작물(作物)의 가리영양(加里營養) 현황(現況)을 살펴봤다. 칼리이온의 물리화학적(物理化學的) 특성(特性)은 Na에 의(依)하여 완전(完全) 대체(代替) 불가능(不可能)함을 보이며 대부분(大部分)의 작물(作物)에서 Na의 K대체(代替)는 불가피(不可避)한 대체기능(代替機能)에 대(對)한 부분적(部分的) 대체(代替)에 불과(不過)한 것 같다. 칼리의 특이성(特異性)은 엽록체(葉綠體) thylacoid막(膜)과 같은 미세구조(微細構造)를 효율적(效率的) 구조(構造)로 유지(維持)하며 주(主)로 탄수화물(炭水化物)과 단백질(蛋白質) 대사(代謝)에 관계(關係)하는 제효소(諸酵素)들의 allosteric effector로, 효율적(效率的) conformation의 유지자(維持者)로 작용(作用)하는 것으로 보였다. 광인산화(光燐酸化) 반응(反應)과 산화적(酸化的) 인산반응(燐酸反應) 등(等) energy 대사(代謝)에 필수적(必須的) 존재(存在)로서 유기물(有機物)의 합성(合成)과 전류등(轉流等) 광범(廣範)한 energy 의존(依存) 생리작용(生理作用)에 관여(關與)하고 있다. 칼리는 삼투압(渗透壓) 및 교질(膠質)의 가수도(加水度)를 유지(維持)하여 수분흡수(水分吸收) 및 전류(轉流)의 동인(動因)으로 작용(作用)하여 생리작용(生理作用)의 최적환경(最適環境)을 만들며 수분효율(水分效率)을 높인다. 칼리는 무기양분(無機養分)의 흡수(吸收)와 체내분포(體內分布)에 영향(影響)을 주고 생산물의 품질향상(品質向上)에도 영향을 주며 생산품의 K함량자체(含量自體)가 인체(人體)에서의 K의 중요성(重要性)으로 품질평가(品質評價)의 기준(基準)이 될 것 같다. 칼리의 흡수(吸收)는 저온(低溫)에 의(依)해 크게 저해(沮害)받으며 내부(內部) 칼리 함량에 의(依)한 부(否)의 feedback기작(機作)이 있어서 칼리의 사치흡수는 재평가(再評價)되어야 할 것으로 보였다. 우리나라 토양(土壤)의 전가리(全加里)는 약(約) 3%이나 치환성(置換性)은 0.3me/100g으로 동해(凍害), 한해(寒害)와 불균일(不均一)한 강우(降雨)로 인(因)한 습해(濕害), 한해(旱害) 등(等)으로 모든 밭 작물(作物)에서 요구도(要求度)가 컸다. 대맥(大麥)은 결빙직전(結氷直前) 및 해빙(解氷) 직후(直後)의 K영양(營養)이 수량(收量)과 유의성(有意性) 상관(相關)을 보이며 곡실(穀實)로 많이 전류(轉流)되는 것이 좋았다. 대맥(大麥)의 가리이용률(加里利用率)은 27%, 대두(大豆)는 숙전(熟田)에서 58% 개간지(開墾地)에서 46%였다. 대두(大豆)는 야산(野山) 개발지(開發地)에서 특(特)히 가리(加里) 결핍증상(缺乏症狀)을 많이 보였으며 화아분화기(花芽分花期)에 엽(葉) 중(中) $K_2O$ 2% 이상(以上) K/(Ca+Mg) (함량비(含量比))비(比)는 1.0 이상(以上)이어야 할 것 같다. 고구마는 가리흡수력(加里吸收力)이 커서 후작(後作)의 K영양(營養)에 크게 영향(影響)을 주었다. 감자와 옥수수는 Ca와 Mg에 비(比)해 K가 특히 높았다. 가리결핍(加里缺乏) 고구마는 뿌리에서 K농도 차이가 가장 컸다. 당근, 가지, 배추, 고추, 무우, 도마도가 가리(加里) 함량(含量)이 많았으며 배추 수량(收量)은 가리(加里)와 정상관(正相關)이었다. 사료작물(飼料作物)의 가리(加里) 함량(含量)은 비교적(比較的) 높은 편이었으며 식물체(植物體) 중(中) N, P, Ca와 유의정상관(有意正相關)을 보였다. 과수원(果樹園)의 16~25%가 가리(加里) 부족(不足)으로 나타났으며 우량(優良) 사과밭과 배밭의 토양(土壤)과 엽(葉)은 가리(加里) 함량(含量)이 높았다. 뽕나무의 동해(凍害)에 의(依)한 가지 끝 고사방지(枯死防止)를 위(爲)한 엽(葉) 중(中) $K_2O/(CaO+MgO)$ 임계치(臨界値)는 0.95이었다. 밭 작물재배(作物栽培) 뒤의 토양(土壤) 중(中) 가리(加里)는 전작(前作)에 따라 증가(增加)되는 경우와 감소(減少)되는 경우가 있으며 가리(加里) 흡수(吸收)는 토양수분(土壤水分)에 존재(依存)하는 것 같다. 따라서 토양(土壤) 중(中)의 전가리(全加里)를 포함한 형태별(形態別) 가리(加里) 함량(含量)의 토질(土質), 기상(氣象), 작부체계(作付體系) 등(等) 제요인(諸要因)과 관련(關聯) 장기적(長期的)이고 정량적(定量的)인 조사(調査)가 필요(必要)하다. 가리(加里)의 추비(追肥), 심층시비(深層施肥) 또는 완용성(緩溶性) 비료(肥料)와 입상비료(粒狀肥料) 등(等)이 강우양상(降雨樣相)과 관련(關聯) 검토(檢討)됨으로써 K흡수(吸收) 및 효율(效率)을 증진(增進)시킬 수 있을 것 같다. 가리영양(加里營養)을 포함하여 밭 작물(作物)의 영양해석(營養解析)에는 다요인분석(多要因分析)에 의(依)한 합리적(合理的)이고 실용적(實用的)인 영양지표(營養指標)를 찾는데 경주(傾注)해야 할 것 같다.

  • PDF

소나무와 리기다소나무를 사용하여 제조한 목재펠릿의 품질 특성 비교 (Comparison of Quality Characteristics of Woodpellet Manufactured from Pinus densiflora S. et Z. and Pinus rigida Mill)

  • 서준원;이응수;강찬영;김시백;윤용한;박헌
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권3호
    • /
    • pp.374-380
    • /
    • 2015
  • 목질 바이오매스 자원의 효율적 에너지화 방안의 일환으로 소나무와 리기다소나무를 목재펠릿으로 만들고, 그 특성을 조사하였다. 제조된 목재펠릿의 함수율, 발열량, 회분, 겉보기밀도, 내구성, 원소분석을 측정하여 비교하였다. 소나무와 리기다소나무 목재펠릿의 원소분석의 결과, 소나무는 61.42% (C), 수소 5.56% (H), 산소 32.87% (O) 그리고 0.15% (N)로 나타났으며, 리기다소나무는 61.03% (C), 수소 5.96% (H), 산소 32.83% (O) 그리고 0.18% (N)로 나타나 두 수종 간에 거의 차이가 없었다. 각 시료의 발열량은 약 19 MJ/kg로서 품질규격 1급((${\geq}18.0MJ/kg$)을 만족시켰다. 회분량의 경우 소나무가 0.50%, 리기다소나무가 0.53%로 양자 간의 차이가 거의 없었으며, 품질규격 1급(${\leq}0.7%$)을 만족시켰다. 겉보기 밀도는 소나무 펠릿의 경우 $648kg/m^3$으로 품질규격 1급(${\geq}640kg/m^3$)을 만족시켰으나, 리기다소나무의 경우 $622kg/m^3$으로 품질규격 2급(${\geq}600kg/m^3$)을 만족시켰다. 함수율의 경우 두 수종 모두 품질규격 1급(${\leq}10%$)를 만족시켰으며, 내구성의 경우 소나무 목재펠릿은 품질규격 3급(${\geq}95%$)를 만족시켰으나 리기다소나무 목재펠릿은 내구성 품질규격을 만족시키지 못하였다.

예천 금당실 송림의 생태적 특성 및 관리방안 (Ecological Characteristics and Management Plan of Geumdangsil Pine Forest of Yecheon)

  • 이수동;이찬;김동욱;김지석
    • 한국환경생태학회지
    • /
    • 제27권6호
    • /
    • pp.718-732
    • /
    • 2013
  • 본 연구는 천연기념물 제469호로 지정된 예천 금당실 송림의 실질적인 보존관리방안 수립을 위한 기초자료를 확보하고 지속가능한 관리 및 보호방안을 제안하였다. 숲에 영향을 주는 문제점을 방지하고 저감하여 숲의 지속가능한 이용과 보전을 위해 본 연구에서는 지형 및 지세, 토지이용, 수목 생육현황, 토양환경, 이용 및 관리현황 등을 조사 분석하였다. 예천 금당실 송림은 해발 130~140m의 평탄지에 위치하며, 주변지역은 대부분 경작지로 이용되었다. 송림에 식재된 수목은 총 565주이며, 이중 소나무가 558주이고 25개의 밑둥이 확인되었다. 식재된 소나무는 흉고직경 30~50cm에 집중되어 있었으며, 평균 수령은 85.4년이었고, 최고 수령은 약 200년으로 추정되었다. 표본목의 가지 생장량은 연간 4.3~5.1cm이며 가장 생장이 왕성한 중앙의 가지는 3년간 평균 24.2cm의 생장을 보였다. 7개 조사구의 토양 이화학적 특성 분석 결과 유기물 함량, 전질소, 유효인산, 전기전도도 항목은 비교적 양호하였으나, 토양 pH, 치환성 양이온 등의 항목에서 개선이 필요하였다. 현재 내부의 시설물와 이용압력은 많지 않은 상태이나, 경작에 의한 잠식 등의 위협요인이 남아있으며, 생태계 관리에 치중한 관리로 시설물, 이용객, 운영 관리 등의 종합적인 관리가 필요한 상태이었다. 본 연구에서 제시한 지속가능한 관리방안은 생태계관리, 시설물관리, 이용객관리, 운영관리 4가지 부분을 고려하였다.

$K(^{86}Rb)-bioassay$를 이용한 감귤나무의 가리영양진단법 개발 (Development of K-bioassay for the Efficient Potassium Fertilization of Citrus Tree)

  • 유장걸;한해룡;문덕영;김창명;임한철;문두경;송성준
    • Applied Biological Chemistry
    • /
    • 제37권3호
    • /
    • pp.182-188
    • /
    • 1994
  • 작물의 인산영양진단을 $^{32}P-bioassay$법에 의하는 것과 같은 원리로 K의 영양진단 가능성을 검토하기 위하여 맥주보리(Hordeum distichum)를 K수준을 달리 공급하여 4주간 수경재배한 후 $^{42}K$(half life: 12.36 hr)와 $^{86}Rb$(half life: 18.86 hr)을 추적자로 사용하여 K-bioassay를 실시했던 바 $^{42}K$$^{86}Rb$의 흡수능은 모두 K의 공급수준과 지수적인 역상관을 나타내어 K의 영양진단이 가능하다는 사실을 확인했으며, 반감기가 짧아서 실험시간의 제한을 받게 되는 $^{42}K$대신 K의 analog로 Rb을 사용할 수 있음도 알게 되었다. 그리고 3년생 조생온주감귤(Citrus unshiu Marc.)을 K공급수준을 달리해서 4개월간 수경으로 재배한 뒤 $^{86}Rb$의 흡수능을 측정한 결과 K공급수준과 지수적인 역상관을 나타내어 맥주보리와 비슷한 경향을 나타냈다. 따라서 감귤나무의 경우 $^{86}Rb$ 추적자를 이용한 K-bioassay가 가능하다고 생각된다. 또한, K시비수준을 달리하여 7주간 재배된 보리의 Rb흡수능이 토양 중 치환성 가리함량과 고도의 상관을 보인 점은 K-bioassay에 의한 Rb흡수능 값과 치환성가리의 함량과의 관계에서 작물의 생육에 적당한 치환성가리 함량을 산정해 낼 수 있다고 사료된다. 한편, 맥주보리와 감귤뿌리에 의한 $^{42}K$$^{86}Rb$의 흡수는 모두 $5{\times}10^{-3}\;M$ KCN에 의해서 크게 저해되었으므로 K와 Rb이 능동적 흡수가 이루어지고 있음을 알 수 있었다. 감귤의 엽중 K함량은 K의 공급수준과 밀접한 상관이 발견되지 않았기 때문에 $^{86}Rb$을 이용한 K-bioassay법은 엽분석보다 더 정확하게 감귤의 생리적인 K요구성을 측정할 수 있다고 생각된다. 그러나 3년생 이상의 감귤나무에 대하여는 포장시험으로 확인되어야 할 것이다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF