• 제목/요약/키워드: Efficiency of ventilation

검색결과 402건 처리시간 0.024초

IR(Infrared) 센서기반 제어방법에 따른 공동주택 멀티 존 환기시스템 평가 연구 (An Evaluation on IR Sensor Based Demand Controlled Ventilation Strategies for Multi-zone in the Apartment House)

  • 홍성민;윤동원
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.174-182
    • /
    • 2012
  • In previous research, most occupant said that they have not operated ventilation system installed in the house, because of increasing of energy consumption and unconcern of ventilation. Therefore, it is necessary to applied the sensor based demand controlled ventilation for the IAQ(Indoor Air Quality) and improvement of energy efficiency in ventilation strategy. The propose of this study is to present a application method of IR(Infrared) sensor for multi-zone DCV(Demand Controlled Ventilation) in the apartment house. It is possible that IR sensor could be used for DCV, because that could detect the occupant and action. IR sensor based DCV strategies are established to evaluate characteristic of application in the apartment house and simulated by Contam program. As a result, they have some week points though, if they would be applied DCV with optimum strategy, it would be useful to improve IAQ, to reduce energy consumption.

추적가스법을 적용한 국내 석회석 광산의 환기성능 평가 연구 (Ventilation Efficiency Evaluation of Domestic Limestone Mine Using Tracer Gas Method)

  • 김영수;노장훈;김진
    • 터널과지하공간
    • /
    • 제26권4호
    • /
    • pp.274-282
    • /
    • 2016
  • 현재 국내에서 가행 중인 석회석 광산은 자연환기력을 주된 환기방법으로 사용하고 있고, 대단면 굴착으로 매우 저속의 공기유동현상이 나타나고 있다. 이로 인하여 작업구간의 공기질이 매우 저하되어 있는 실정이다. 이러한 문제점들을 개선하기 위해서는 먼저 환기성능을 면밀하게 평가할 필요가 있다. 본 연구에서는 이러한 환기성능평가를 위해서 추적가스법을 적용하여 평가를 실시하였다. 연구 결과, 추적가스법을 통해 매우 저속의 공기유동, 공기재순환현상, 작업장 공기교환율 등을 정량적으로 평가함에 따라서 연구광산의 환기문제점들을 정밀하게 확인할 수 있었다. 이러한 추적가스법을 활용한 환기성능 평가방법은 광산의 작업환경 개선을 위하여 매우 정밀한 도구로 사용될 수 있음을 확인하였다.

건축물의 대공간 집회시설의 실내공기질 개선방안에 관한 연구 (A Study of the Indoor Air Quality Improvement for Large Scale Assembly Facilities)

  • 임태섭;강승모
    • 한국실내디자인학회논문집
    • /
    • 제20권4호
    • /
    • pp.183-190
    • /
    • 2011
  • Lately majority of churches have preferred to enlarge their worship area to both horizontal and vertical axis. According to expand their area which brings more devotees to the limited service area. Transform from a small church into a large church is no longer unprecedented issue in South Korea. As the size of church getting bigger, many unexpected issues become matters. One of the significant problem is that the number of people have experienced either fall a sleep or feel a doziness during their service period. Due to the limited condition for the specific building type such as religion facility(church), IAQ improvements is seriously concerned. Therefore, we are going to examine by using simulation tool, CF, a difference of ventilation efficiency about the location and number of windows, and find the best way of the ventilation efficiency in a multi-stories type church by changing the exhaust pipes location and size. Furthermore, in this thesis, by changing a ceiling height from the existing building to confirm that $CO_2$ have been satisfied for both the ventilation efficiency and IAQ.

IoT와 기계학습을 이용한 스마트 환풍기 제어 시스템 구현 (Implementation of Smart Ventilation Control System using IoT and Machine Learning)

  • 이희은;최진구
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권2호
    • /
    • pp.283-287
    • /
    • 2020
  • 본 논문에서는 스마트폰 앱을 통하여 환풍기의 현재 상태 모니터링, on/off 기능 등 IoT를 지원하는 제어 시스템을 구현하였다. 기계학습(Machine Learning) 알고리즘 종류 중 하나인 지도학습에 포함되는 선형회귀(Linear Regression)를 적용하여 자율적으로 가정의 실내 온도, 습도의 데이터를 수집하여 상태를 진단하고 운전하면서 에너지를 최대한 효율적으로 사용하면서 사용자의 요구를 충족하도록 하였다. 구현한 시스템에서는 수동제어보다 같은 습도가 되는 데 필요한 환풍기의 작동 시간이 더 적다는 것으로 더 좋은 에너지 효율을 확인할 수 있었다. 이로 인해 사용자들은 기존의 환풍기보다 더욱 편리하고 효율적으로 사용할 수 있을 것으로 기대된다.

터널 환기용 제트홴의 성능 향상을 위한 수치최적화 (Numerical Optimization for Performance Improvement of a Tunnel Ventilation Jet fan)

  • 김준형;김진혁;김광용;윤준용;최영석;양상호
    • 한국유체기계학회 논문집
    • /
    • 제14권5호
    • /
    • pp.63-68
    • /
    • 2011
  • This paper presents an optimization procedure for performance improvement of a tunnel ventilation jet fan. Optimization techniques based on response surface approximation (RSA) are employed to improve the aerodynamic performance of a tunnel ventilation jet fan. For numerical analysis, three-dimensional Renolds- averaged Navier-Stokes (RANS) equations with shear stress transport turbulence model are discretized by using finite volume approximations and solved on hexahedral grids to evaluate the total efficiency at the operating condition as the objective function. Four geometric variables defining the meridional length and the thickness profile at the hub and shroud in the jet fan rotor are selected as design variables for the numerical optimization. The results of the numerical optimization show that the total efficiency of the optimized model is significantly improved in comparison with the base model.

전산유체역학을 이용한 표준 오리사 설계안에 대한 환기효율성 분석 (Analysis on Ventilation Efficiency of Standard Duck House using Computational Fluid Dynamics)

  • 여욱현;조예슬;권경석;하태환;박세준;김락우;이상연;이승노;이인복;서일환
    • 한국농공학회논문집
    • /
    • 제57권5호
    • /
    • pp.51-60
    • /
    • 2015
  • In Korea, 69.4 % of duck farms had utilized conventional plastic greenhouses. In this facilities, there are difficulties in controlling indoor environments for raising duck. High rearing density in duct farms also made the environmental control difficult resulting in getting more stressed making their immune system weaker. Therefore, a facility is needed to having structurally enough solidity and high efficiency on the environmental control. So, new design plans of duck house have recently been conducted by National Institute of Animal Science in Korea. As a study in advance to establish standard, computational fluid dynamics (CFD) was used to estimate the aerodynamic problems according to the designs by means of overall and regional ventilation efficiencies quantitatively and qualitatively. Tracer gas decay (TGD) method was used to calculate ventilation rate according to the structural characteristics of duck houses including installation of indoor circulation fan. The results showed that natural ventilation rate was averagely 164 % higher than typically designed ventilation rate, 1 AER ($min^{-1}$). Meanwhile, mechanically ventilated duck houses made 81.2 % of summer ventilation rate requirement. Therefore, it is urgent to develop a new duck house considering more structural safety as well as higher efficiency of environmental control.

복합식 공기청정기의 물리적 및 생물학적 입자상 물질의 제거 효과 (Efficiency of the Hybrid-type Air Purifier on Reducing Physical and Biological Aerosol)

  • 김기연;김치년;김윤신;노영만;이철민
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.478-484
    • /
    • 2006
  • There was no significant difference in the CADR (Clean Air Delivery Rate) between physical aerosols, NaCl and smoke, and biological aerosols, airborne MS2 virus and P. fluorescens, which implicate that the hybrid-type of air purifier, applying the unipolar ion emission and the radiant catalytic ionization, imposed identical reduction effect on both physical aerosol and bioaerosol. Ventilation decreases the efficiency of air cleaning by unipolar ionization because high ventilation diminishes the particle concentration reduction effect. The particle removal efficiency decreases with increase in the chamber volume because of the augmented ion diffusion and higher ion wall loss rate. Particle size affects the efficiency of air ionization. The efficiency is high for particles with very small diameter because reduction of charge increases with particle size. If there is no increasing supply of ions, the efficiency of air cleaning by unipolar ionization increases with respect to initial concentration of particles because of the large space charge effect at high particle concentration and amplified electric field.

건축물에너지효율등급 기밀시험이 등급에 미치는 영향분석 (Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds)

  • 김대원;정광섭;김영일;남아리새;주정경
    • 에너지공학
    • /
    • 제23권1호
    • /
    • pp.40-45
    • /
    • 2014
  • 주거시설에서 환기횟수 0.7회 적용은 실내공기질 향상과 거주자의 쾌적성을 높이고자 100세대 이상은 의무적으로 적용하고 있다. 건축물에너지효율등급에서는 환기횟수를 기준으로한 기밀시험을 실시 하여 그결과 값을 효율등급결과치에 반영함으로서 창호주변의 정밀시공을 유도하고 침기로 인해 손실되는 에너지절감을 꾀하고 있다. 건축물엔지효율등급 현장실사 결과 환기횟수가 0.6~0.71까지 나타났으며 그차이가 에너지 절감량에 크게 영향을 미치는 것으로 나타났다. 유럽의 패시브 하우스 기준이 0.6회 이하의 기밀을 요구하고 있고 우리나라도 2017년 패시브하우스, 2025년 제로하우스를 목표로 하고 있어 비주거 건물의 기밀진단의 의무확대와 고기밀 건물에 대한 연구와 시공방법이 시급한 실정이다.

쏠라 썬루프를 이용한 주차환기 시스템의 효과에 관한 실험적 연구 (An Experimental Study on the Benefit of Pre-ventilation Using Solar Sunroof)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제22권6호
    • /
    • pp.89-95
    • /
    • 2014
  • This study presented the benefit of the pre-ventilation using solar sunroof with integrated photovoltaic. Recent year, auto-makers make an effort to enhance the fuel efficiency and moreover to clean the cabin passenger's health. Solar energy, one of the alternative energies, adapted in automotive air handling system, in order to pre-ventilation when vehicle parked under the sun in summer. The power generated by a prototype solar sunroof has been used to run blower in a air handing system. And the solar sunroof was installed in a vehicle, and evaluated to find out benefit of the pre-ventilation. The effect of reducing the cabin temperature about $3^{\circ}C{\sim}10^{\circ}C$ with 20 ~ 40W power generator from solar sunroof were obtained in the pre-ventilation test. This reduced thermal load can lead to the reduction of air-conditioning operation time than that of current car. Moreover, fuel economy may increase as a results of the short use of the air-conditioning time. Additionally, Total Volatile Organic Compounds in the cabin is reduced maximum 80% than that of the current vehicle.

광산 통기수갱발파에서 전색조건이 발파효율에 미치는 영향에 관한 수치해석적 연구 (Numerical Analysis on Effect of Stemming Condition in Mine Ventilation Shaft Blasting)

  • 김준하;김정규;정승원;고영훈;;김종관
    • 화약ㆍ발파
    • /
    • 제39권3호
    • /
    • pp.15-23
    • /
    • 2021
  • 통기 수갱은 지하공간 개발시 분진 또는 매연 등을 제거하기 위해 광산과 터널에서 사용되는 통로이다. 광산에서는 통기 수갱 개발을 위해 10~20m 구간의 크라운필라 영역을 1회의 장공발파로 굴착하는 공법이 적용 가능하다. 이 경우 천공오차를 파악하기 위해 장약공을 완전히 천공하였을 때 장약공 하부가 구속되지 않으며, 또한 이는 폭약 장약과 발파효율을 떨어트리는 문제를 발생시킨다. 이는 장약공 하부에 전색을 사용함으로 장약공 하부를 전색하여 폭약 장약의 문제를 해결하고 발파효율을 증가시킬 수 있다. 본 연구에서는 ANSYS AUTODYN 2D SPH(Smooth particle hydrodynamics) 해석기법을 이용하여 장약공 직경(45, 76mm)과 다양한 전색장을 달리한 통기 수갱 발파 시뮬레이션을 실시하였다. 또한 발파에 따른 하부의 대괴 사이즈, 저항선을 확인하여 최적의 하부전색장을 도출하였다. 해석 결과 하부전색장 30cm 이하의 경우 발파효율이 저하되며, 발파효율을 높이기 위해서 30cm 이상의 전색장을 적용하여야 함을 확인하였다.