• Title/Summary/Keyword: Effective floor area

Search Result 98, Processing Time 0.035 seconds

Seismic study of buildings with viscoelastic dampers

  • Pong, W.S.;Tsai, C.S.
    • Structural Engineering and Mechanics
    • /
    • v.3 no.6
    • /
    • pp.569-581
    • /
    • 1995
  • In this paper, the seismic behavior of a 10-story building equipped with viscoelastic dampers is analyzed. The effects of ambient temperature, the thickness, the total area, and the position of the viscoelastic dampers are studied. Results indicate that the energy-absorbing capacity of viscoelastic damper decreases with increasing the ambient temperature. The thickness and the total area of viscoelastic dampers also affect the seismic mitigation capacity. The thickness cannot be too small, which is not effective in vibration reduction, nor can it be too large, which not only increases the cost but also reduces the seismic resistance. The total area of viscoelastic dampers should be determined properly for optimum damper performance at the most economical design. The mounting position of viscoelastic dampers also influences the structure's seismic performance. Numerical results show that, if properly equipped, the VE dampers can reduce the structural response both floor displacement and story shear force and increase the overall level of damping in structures during earthquakes.

A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance (염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구)

  • Oh, Myung-Hwan;Sim, Se-Ra;Lee, Chul-Sung;Chin, Kyung-Il;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

A Study of Utilization of Semi-public Space of Street for the Betterment in Life Environment (도시생활환경 개선을 위한 도로변 공개공지의 활용실태에 관한 연구)

  • 김한수;정준현
    • Journal of the Korean housing association
    • /
    • v.11 no.2
    • /
    • pp.85-95
    • /
    • 2000
  • This study tries to promote an effective use of semi-public space of urban street in social point of view. The main results are follows. First, semi-public space is occupied by private users and it makes urban landscape unrecoverable. The real problem is that people do not know the space is for public use rather than pure private use. Second, the standard of semi-public space requirement should be changed from floor space to lot area. In addition, the standard should apply to buildings on an area less than a legal standard. Third, some ways of attaining the semi-public space in relation with adjacent lots should be introduced in the case of urban redevelopment nad living condition improvement projects.

  • PDF

A Case Study on the Environmental Improvement of Low-Rise and High-Density Housing (저층고밀형 주택지 정비수법에 관한 연구)

  • Lee, Dong-Hyun;Baek, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.1
    • /
    • pp.44-53
    • /
    • 2009
  • The Purpose of this study is to find out necessity and possibility of low-rise high density housing improving an old residential district of hillside areas. Housing of hillside areas should be maintained and it is necessary to make topographical adaptation plan. For this purpose, we calculate the floor area ratio to break even on case study area by GIS date. As a result, we found out that floor area ratio as minimum qualifications for the feasibility of urban redevelopment is 180%, and carried out a landscape simulation to a low-rise high density housing by AutoCAD 2004 and ArcView 3.2a. In results of simulations, it reveals that a rule to low-rise high density housing effective for topographical adaptation development.

  • PDF

Optimum Collector Area and Economic Evaluation for the Greenhouse Heating (태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가)

  • Pak, Ee-Tong;Kim, Kyu-In
    • Solar Energy
    • /
    • v.2 no.1
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF

A Study of Efficient Floor Planning and Facility Improvement for Physical Therapy Room of Domestic Long-term Hospitals (국내 요양병원의 물리치료실의 효율적 평면계획 및 시설개선에 관한 연구)

  • Chung, Kwang-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.4
    • /
    • pp.5-11
    • /
    • 2011
  • The present study investigated the actual conditions of physical therapy rooms at long-term hospitals in Korea and conducted a comparative analysis to develop an efficient floor plan and facility improvement measures. 1. At hospitals surveyed, physical therapy services were used at a high frequency but they did not have enough space for rehab treatment and long paths of patient flow were found to make patient management inconvenient. Therefore, physical therapy units should be conveniently located both in terms of distance and direction so as to be accessible from patient rooms or wards. The space should be organized in a concentrated layout for efficiency of physical therapy, and floor planning for therapy units should ensure the best possible viewing angle to therapists. 2. With regard to the disease characteristics of patients, many physical therapy rooms were in difficult circumstances because of poor facilities, so they need to secure skilled personnel, supplement apparatuses and equipment and have rooms for functional recovery, hydrotherapy and operation treatment. In addition, each of the curtained or partitioned areas for treatment should be set up with consideration for the amount of space taken up by medical equipment. The area under each bed should be designed for patient convenience so that it can be used as storage space for patient's belongings and shoes. 3. Patients complained about the lack of physical therapy space, resting places or exercise areas and demanded the expansion of rehab programs and facilities. Physical therapy facilities need to be improved for patient privacy and effective natural ventilation. 4. At most of the long-term hospitals surveyed, physical therapy units were found to have small areas and treatment equipment and devices were insufficient compared to the number of patients. Therefore, it is required to secure more space (at least 138.24 sq. meters per 100 beds) and improve facilities for better physical therapy services.

Behavior Analysis According to the Shear Wall Layout of Column-Supported Wall System Subject to Vertical and Lateral Loads (연직 및 횡하중이 작용하는 상부벽식-하부골조구조물의 벽체 배치유형에 따른 거동 해석)

  • Lee, Dae-Hyeon;Kim, Ho-Soo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.2 s.12
    • /
    • pp.53-61
    • /
    • 2004
  • Recently, most of residential-commercial buildings and apartment houses which are being constructed in the downtown area mainly adopt hybrid structural systems to compose various spaces. Especially, column-supported wall system which is one of the hybrid systems includes shear wall and rigid frame structure and these structures are connected by the transfer floor. But this system is very disadvantageous from the viewpoint of structural safety and is difficult to find out the stress distribution at the transfer floor. Therefore, this study analyzes the behavior and stress distribution according to the shear wall layout of transfer girder system subject to vertical and static lateral loads. Also, this study recognizes load paths and stress concentration based on the analysis results nearby the transfer floor and presents guidelines for the effective design of wall and transfer girder.

  • PDF

The Amount of House Mite Allergens & Dusts According to Environmental Factors of Patients With Allergic Rhinitis (알레르기성비염 환자 침실의 환경적 특성에 따른 집먼지 진드기 항원량과 먼지량)

  • Moon Jung Soon;Choi Soon Ock
    • Journal of Korean Public Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.51-60
    • /
    • 1996
  • This study was conducted to provide basic knowledges of effective environmental control of patients with allergic rhinitis. From July to October 1995, 58 dust samples Were drawn from the bedrooms of patients with allergic rhinitis who were registerd at an allergy clinic of a hospital. Those samples were examined for the amount of house mite allergens & dusts. The data were analysed by using ANOVA and Pearson correiation coefficients. The results were as follows : 1. As for the amount of house mite allergens in terms of environmental factors, the amount of house mite allergens of using washing water temperature of bedding above than $55^{\circ}C$ was significantly lower than that of below $54^{\circ}C$. Other environmental factors such as type of house, area of bed room floor, bed in bedroom, bedroom cleaning by vacuum cleaner, days after bedding washing, relative humidity of bedroom were relate to the amount of house mite allergens. 2. As for the amount of dusts in terms of environmental factors, the amount of dusts of days of days after bedding washing more than 15 days was significantly lower than thant of less than 15days. Other environmental factors such as type of house, area of bedroom floor, bed in bedroom, bedroom cleaning by vacuum cleaner, was hing water taemperature of bedding, relative humidity of bedroom were not relate to the amount of dusts. 3. There was a significant positive correlation between the amount of house mite allergens and the amount of dusts. It may be conclusively said. the amount of dusts and house mite allergens were closely associated with the washing temperature and days after washing of bedding. Hence. intensive instruction for the methods of bedding washing was needs of the patients with allergic rhinitis.

  • PDF

Survey of the Land-Cover Type Pattern in High-rise Building (초고층 건축물 외부공간의 토지피복 변화에 관한 연구)

  • Hong, Suk-Hwan;Han, Bong-Ho;Kim, Hong-Soon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.2
    • /
    • pp.15-23
    • /
    • 2012
  • This study was accomplished by analyzing the change of land cover pattern in high-rise buildings in Korea. For this study, we selected 15 locations of high-rise buildings. The ratio of average building coverage and paved area was 79.7%, and both green and water area were low, relatively. The biotope area factor of the site showed low percentage by 15.90% due to the underground space development. As a result of correlation analysis between the time of construction and land-cover type, building coverage has been decreased according to the stream of time. However, biotope area factor has been increased And, the paved area has m correlation. It was identified that reducing paved area is effective to enhance the ecological functions of a high-rise building outdoor.

Imputation Methods for the Population and Housing Census 2000 in Korea

  • Kim, Young-Won;Ryu, Jeabok;Park, Jinwoo;Lee, Jaewon
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.2
    • /
    • pp.575-583
    • /
    • 2003
  • We proposed imputation strategies for the Population and Housing Census 2000 in Korea. The total area of floor space and marital status which have relatively high non-response rates in the Census are considered to develope the effective missing value imputation procedures. The Classification and Regression Tree(CART) is employed to construct the imputation cells for hot-deck imputation, as well as to predict missing value by model-based approach. We compare three imputation methods which include CART model-based imputation, hot-deck imputation based on CART and logical hot-deck imputation proposed by The Korea National Statistical Office. The results suggest that the proposed hot-deck imputation based on CART is very efficient and strongly recommendable.