• Title/Summary/Keyword: Effective Power Usage

Search Result 88, Processing Time 0.025 seconds

A Study of Ground System improvement on Isolated Power Generation (독립 전원설비에서의 접지방법 개선에 관한 연구)

  • 류보혁;남택주;김정훈
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.96-102
    • /
    • 2001
  • In construction sites, portable generators and electrical equipments cause frequently electrical accidents due to the poor condition of their usage. However, there are very few technical guidelines on these equipments even though they have serious accident causing potentiality. In order to reduce such accidents in practical and economical, grounding methods are studied in this paper as the countermeasure of electrical accidents. Several Korean national standards and international standards regarding three grounding types are compared each other, and some prevention means of electrical accidents are reviewed in this study. This paper presents the most effective grounding methods by assuming the WCS with the isolated power systems.

  • PDF

Control of accidental discharge of radioactive materials by filtered containment venting system: A review

  • Bal, Manisha;Jose, Remya Chinnamma;Meikap, B.C.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.931-942
    • /
    • 2019
  • Radioactive materials are released from the molten core into the containment at the time of a severe accident in a nuclear power plant (NPP). Filtered containment venting system is a popular and effective safety measure installed to obstruct the uncontrolled escape of radioactive materials due to the over pressurization of the containment. Different designs of filtered containment venting system (FCVS) are available today, each being the result of extensive research and development varying in one way or the other. This paper gives an elaborate description of the different types of FCVS currently being used, the current usage status in over 17 countries and the legislations regarding it. The recent researches being carried out in this field has also been discussed in detail. This present paper focuses on the critical review of existing FCVS, reports the challenges faced by it and highlights the potential developments to overcome the difficulties.

Antioxidant Activity of Main and Fine Roots of Ginseng (Panax Ginseng C.A. Meyer) Extracted with Various Solvents

  • Kim, Ji-Sang;Yoon, Ki-Sun;Lee, Young-Soon
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.46-51
    • /
    • 2008
  • The objective of this study was to investigate antioxidant activities of freeze-dried, main root, and fine root of ginseng (Panax ginseng CA. Meyer), which were extracted with various solvents including ethanol, methanol, and water. Ethanol extracts in both parts showed the most powerful scavenging activities against DPPH radicals. Especially, ethanol extract of fine root had higher reducing power and antioxidant capacity than that of main root. The highest antioxidant activity in linoleic acid emulsion system was also observed in fine root extracted with ethanol, followed by methanol and water. Both ferrous ion chelating activity and ferric reducing antioxidant power (FRAP) of extracts were increased with the increase of extracts concentration. These results suggest that ethanol extract of fine root of ginseng has the most effective antioxidant capacity compared to the methanol and water extracts tested in the present study. Thus it can be applied for the effective extraction of functional material from ginseng for the usage of pharmaceutical and/or food industries.

Communication Module Selection Algorithm for Energy Saving of Smartphone (스마트폰 에너지 절감을 위한 통신모듈 선택 알고리즘)

  • Lee, Chang-Moo;Lee, Seung-Jae;Choi, Deok-Jai
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.22-31
    • /
    • 2012
  • A Smartphone is an intelligent device combined mobile phone and pc's support functions, and can perform multiple functions to satisfy the demands of users. It has excellent processing power and communication modules(DMB, Wi-Fi, Bluetooth, NFC etc) to carry out the demands of users. But continuous using of battery power on processor and equipped modules causes acceleration of battery consumption. This means that effective power management in devices like smartphone is important. Therefore, the management of power consumption on system execution and communication module is a serious issue in this field of study. In this paper, we would like to propose a communication module selection algorithm based on energy consumption parameter of each communication module and data transfer time. Our scheme automatically select appropriate communication system to reduce high energy consumption on bluetooth sleep mode so that this scheme is more efficient and effective thus improving user convenience in longer usage time. Experimental results showed the 20% energy saving.

A Development of Monitoring and Control System for Improved the Voltage Stability in the Power System (전력계통의 전압안정도향상을 위한 감시제어시스템 개발)

  • Lee, Hyun-Chul;Jeoung, Ki-Suk;Park, Ji-Ho;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.437-443
    • /
    • 2013
  • This paper was developed a monitoring and control system to use reactive power control algorithm. This algorithm could be improved voltage stability in power system. This method was controlled the voltage for stability improvement, effective usage of reactive power, and the increase of the power quality. PMS(Power Management System) has been calculate voltage sensitivity, and control reactive power compensation device. The voltage control was used to the FACTS, MSC/MSR(Mechanically Switched Capacitors/Reactors), and tap of transformer in power system. The reactive power devices in power system were control by voltage sensitivity ranking of each bus. Also, to secure momentary reactive power, it had been controlled as the rest of reactive power in the each bus. In here, reactive power has been MSC/MSR. The simulation result, First control was voltage control as fast response control of FACTS. Second control was voltage control through the necessary reactive power calculation as slow response control of MSR/MSR. Third control was secured momentary reactive reserve power. This control was method by cooperative control between FACTS and MSR/MSC. Therefore, the proposed algorithm was had been secured the suitable reactive reserve power in power system.

Fault tolerant control scheme for a converter in a photovoltaic system (태양광 발전시스템의 컨버터 고장에 따른 보상운전기법)

  • Park, Tae-Sik;Hur, Yong-Ho;Lee, Kwang-Woon;Moon, Chae-Joo;Kwak, No-Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.31-40
    • /
    • 2016
  • The demands for photovoltaic systems on a large scale have grown dramatically and require new technologies to get the high efficiency and reliable operations of power conversion systems. These needs can be realized by the cost-effective and high performance digital revolutions and faster semiconductor switching devices. However, the new power systems have been more sophisticated and their reliability becomes critical issues. In this paper, a new fault-tolerance power conversion scheme for the photovoltaic systems is proposed. The proposed fault-tolerant scheme is able to supply energy from solar panels to loads intermittently in spite of a front boost converter open failure, and its voltage and current controllers are designed to improve the transient performance by using an average model design scheme. The proposed approach is verified both by simulations. The results will enable more timely and wide usage of alternative/renewable energy systems resulting in increased energy security.

Development of a Power Management System for Efficient Power usage of Intelligent Ship (지능형 선박의 효울적인 전력사용을 위한 전력 관리 시스템 개발)

  • Park, Ji-Sang;Jeon, Min-Ho;Lee, Myung-Eui
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.609-615
    • /
    • 2013
  • As with any ships, adequate power provision is crucial, especially on the ocean navigating ships far from the land. In order to resolve the effective and economic power supply system of any ship in operation, in this paper, we propose a power management system that intelligently controls the power supply in ships. Power management systems in this design consist of a power load detection system, a generator configuration system, and a power monitoring system respectively. The CT / PT sensor is used to measure amount of current and power in the power detection system, and according to the collected information from various sensor, the generator configuration system will switch on and off the main / sub generator effectively. Finally, the power monitoring system will display all status information of this power management system at a glance for users. This power management systems implemented in this paper is evaluated via real-time experiments, which works well as designed, and certified by KSCIEC61892-1:2012 and KSCIEC60950-1:2008.

A Study of Edge Detection for Auto Focus of Infrared Camera

  • Park, Hee-Duk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.1
    • /
    • pp.25-32
    • /
    • 2018
  • In this paper, we propose an edge detection algorithm for auto focus of infrared camera. We designed and implemented the edge detection of infrared image by using a spatial filter on FPGA. The infrared camera should be designed to minimize the image processing time and usage of hardware resource because these days surveillance systems should have the fast response and be low size, weight and power. we applied the $3{\times}3$ mask filter which has an advantage of minimizing the usage of memory and the propagation delay to process filtering. When we applied Laplacian filter to extract contour data from an image, not only edge components but also noise components of the image were extracted by the filter. These noise components make it difficult to determine the focus state. Also a bad pixel of infrared detector causes a problem in detecting the edge components. So we propose an adaptive edge detection filter that is a method to extract only edge components except noise components of an image by analyzing a variance of pixel data in $3{\times}3$ memory area. And we can detect the bad pixel and replace it with neighboring normal pixel value when we store a pixel in $3{\times}3$ memory area for filtering calculation. The experimental result proves that the proposed method is effective to implement the edge detection for auto focus in infrared camera.

Material distribution optimization of 2D heterogeneous cylinder under thermo-mechanical loading

  • Asgari, Masoud
    • Structural Engineering and Mechanics
    • /
    • v.53 no.4
    • /
    • pp.703-723
    • /
    • 2015
  • In this paper optimization of volume fraction distribution in a thick hollow cylinder with finite length made of two-dimensional functionally graded material (2D-FGM) and subjected to steady state thermal and mechanical loadings is considered. The finite element method with graded material properties within each element (graded finite elements) is used to model the structure. Volume fractions of constituent materials on a finite number of design points are taken as design variables and the volume fractions at any arbitrary point in the cylinder are obtained via cubic spline interpolation functions. The objective function selected as having the normalized effective stress equal to one at all points that leads to a uniform stress distribution in the structure. Genetic Algorithm jointed with interior penalty-function method for implementing constraints is effectively employed to find the global solution of the optimization problem. Obtained results indicates that by using the uniform distribution of normalized effective stress as objective function, considerably more efficient usage of materials can be achieved compared with the power law volume fraction distribution. Also considering uniform distribution of safety factor as design criteria instead of minimizing peak effective stress affects remarkably the optimum volume fractions.

A Study on Leakage of Critical Information via the Power Analysis of Power Lines (전원선의 전력분석을 이용한 주요정보 유출 가능성에 관한 연구)

  • Han, Kyong-Ho;Lee, Seong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1571-1574
    • /
    • 2014
  • In this paper, we propose a unidirectional transmission of critical information obtained by keyboard hacking or kernel and keyboard driver hacking even though the computer is not connected to the external network. We show the hacking can be attempted in the proposed method to show the way preventing such attempts in advance. Firewalls and other various methods are used to prevent the hacking from the external network but the hacking is also attempted in various ways to detour the firewall. One of the most effective way preventing from the hacking attack is physically disconnect the internal intranet systems from the external internet and most of the government systems, military systems and big corporate systems are using this way as on one of the protection method. In this paper, we show the feasibility of transmission of security codes, etc via the short message to the external network on the assumption that a hacking program such as Trojan Horse is installed on the computer systems separated from the external network. Previous studies showed that the letters on the monitor can be hijacked by electromagnetic analysis on the computer to obtain the information even though the system is not connected ti the network. Other studies showed that the security code hint can obtained by analyzing the power consumption distribution of CPU. In this paper, the power consumption distribution of externally accessible power line is analyzed to obtain the information and the information can be transmitted to the external network. Software controlling the CPU and GPU usage is designed to control the power supply of computer. The sensors such as the Rogowski coils can be used on the external power line to collect the data of power consumption change rates. To transmit the user password by short message, due to the capacitive components and the obstacle from other power supply, A very slow protocol are used.