• Title/Summary/Keyword: Effective Flow Area

Search Result 466, Processing Time 0.034 seconds

A NUMERICAL INVESTIGATION ON THE INTERNAL FLOW CHARACTERISTICS IN TURBINE NOZZLE BY VARIATION OF ITS FLOW AREA (목 면적 변화에 따른 터빈노즐 내부 유동 특성에 관한 수치적 조사)

  • Kim, Y.C.;Kang, W.T.;Shin, B.R.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.584-585
    • /
    • 2010
  • A numerical simulation was performed to investigate the internal flow characteristics in gas turbine nozzle by the variation of flow area of the nozzle. In general the area of turbine nozzle is chosen by the most substantial factor on performance improvement of turbine at the first stage. In the performances test through CFD analysis for three types of nozzle with conventional, enlarged and reduced area, reduced one with effective flow area (EFA) was the most efficient. That is the minimum effective value within EFA limit defined by the manual of technical order had a good performance. It is useful to avoid the low power problem in the test of performance after maintenance and overhaul of turbine engine.

  • PDF

Experimental Study for Effective Flow and Force Area of Discharge Valve System in a Linear Compressor (리니어 압축기 토출밸브계의 유효 유동면적 및 힘면적에 관한 실험적 연구)

  • Lee Byung-Chan;Lee Hyuk;Ahn Tae-Kil
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.7 s.184
    • /
    • pp.122-129
    • /
    • 2006
  • The linear compressor has lately attracted considerable attention because of its low power consumption and excellent efficiency. For an efficient design, it is necessary to develop an analytical model of the linear compressor. The effective flow and force areas are important parameters to describe the behavior of the linear compressor, which are used to determine the mass flow rates through the valving systems and the forces on the valves, respectively. It is not easy to estimate these parameters because shapes of the valve systems of the linear compressor are so different from those of tile conventional valve systems. In this paper, we suggest method to measure experimentally the effective discharge flow and force areas of the linear compressor and analyze valve characteristic to apply the experimental results to their theoretical model.

One-Dimensional Analysis of Air-Water Two Phase Natural Circulation Flow (공기와 물의 이상 자연순환 유동의 1 차원 해석)

  • Park, Rae-Joon;Ha, Kwang-Soon;Kim, Jae-Cheol;Hong, Seong-Wan;Kim, Sang-Baik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2626-2631
    • /
    • 2007
  • Air-water two phase natural circulation flow in the T-HERMES (Thermo-Hydraulic Evaluation of Reactor cooling Mechanism by External Self-induced flow)-1D experiment has been evaluated to verify and evaluate the experimental results by using the RELAP5/MOD3 computer code. The RELAP5 results have shown that an increase in the coolant inlet area leads to an increase in the water circulation mass flow rate. However, the water outlet area does not effective on the water circulation mass flow rate. As the coolant outlet moves to a lower position, the water circulation mass flow rate decreases. The water level is not effective on the water circulation mass flow rate. As the height increases in the air injection part, the void fraction increases. However, the void fraction in the upper part of the air injector maintains a constant value. An increase in the air injection mass flow rate leads to an increase in the local void fraction, but it is not effective on the local pressure.

  • PDF

A study on Spray Characteristic of Fuel Injection Nozzle with Geometrical Shape Changes of Needle Valve (연료분사노즐의 니들밸브 형상변화에 따른 분무특성에 관한 연구)

  • 채재우
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.35-40
    • /
    • 1987
  • The experimental study, using constant pressure injection system, is carried out to investigate the effect of the geometrical shape changes of the needle valve of the effective flow area, the spray angle and the Sauter's Mean Diameter according to needle valve lift for a pintle-type injection nozzle. The results are as follows: 1) With the increase of the needle valve lift, the effective flow area is increased, the spray angle is at first increased and later decreased, and the Sauter's Mean Diameter is decreased. 2) It is also shown that the spray angle is maximum at the rapidly increased region of the effective flow area.

  • PDF

Effect of emergency core cooling system flow reduction on channel temperature during recirculation phase of large break loss-of-coolant accident at Wolsong unit 1

  • Yu, Seon Oh;Cho, Yong Jin;Kim, Sung Joong
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.979-988
    • /
    • 2017
  • The feasibility of cooling in a pressurized heavy water reactor after a large break loss-of-coolant accident has been analyzed using Multidimensional Analysis of Reactor Safety-KINS Standard code during the recirculation phase. Through evaluation of sensitivity of the fuel channel temperature to various effective recirculation flow areas, it is determined that proper cooling of the fuel channels in the broken loop is feasible if the effective flow area remains above approximately 70% of the nominal flow area. When the flow area is reduced by more than approximately 25% of the nominal value, however, incipience of boiling is expected, after which the thermal integrity of the fuel channel can be threatened. In addition, if a dramatic reduction of the recirculation flow occurs, excursions and frequent fluctuations of temperature in the fuel channels are likely to be unavoidable, and thus damage to the fuel channels would be anticipated. To resolve this, emergency coolant supply through the newly installed external injection path can be used as one alternative means of cooling, enabling fuel channel integrity to be maintained and permanently preventing severe accident conditions. Thus, the external injection flow required to guarantee fuel channel coolability has been estimated.

Analysis of Woven Wire Wick Structure for a Miniature Heat Pipe (소형 히트파이프용 편조 윅의 형상 해석)

  • 이진성;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.1
    • /
    • pp.18-24
    • /
    • 2001
  • Woven wire wick is very effective structure because of its easiness to insert inside of pipe for a miniature heat pipe. The present study was conducted to investigate the effect of the effective flow passage with respect to wire helix angle. Also effective thermal conductivity were examined by defining mean porosity considering effective liquid flow passages. Effective heat transfer area is varied with respect to wire helix angle, and in the range of $\thet=60~65^{\circ}C$, heat transfer area is decreased about 15~20%. Permeability of woven wire wick shows similar value of 200 mesh screen wick. And comparison of experimental results on effective thermal conductivity shows a fairly good agreement with the analytical results.

  • PDF

Effect of the Orifice Area Ratio on the Exit Flow of a Multi-Perforated Tube (다공튜브 오리피스 면적비 변화가 출구유동에 미치는 영향)

  • Lee, Sang-Kyoo;Lee, Jee-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.317-323
    • /
    • 2013
  • A multi-perforated tube indicates the existence of multiple holes of various shapes on the surface of a long cylinder-type or rectangular tube, and a hole installed on the surface is called an orifice, as it is relatively small in size, compared with the surface area of the tube. In this study, the flow characteristics of a circular multi-perforated tube with many orifices on the surface were investigated experimentally and numerically. The volume flowrate issuing from each orifice, discharge angle, effective flow area ratio, and the flow fields around the orifices were measured and visualized, with the variation of the orifice area ratio, at the same blockage ratio. The volume flowrate distributions along the flow direction of the multi-perforated tube tends to be more uniform, as larger orifices were positioned at the inlet side of the multi-perforated tube, compared with no orifice area change along the flow direction.

an Analysis of the Variation on the Impedance Characteristic according to Effective Area of Globe Control Valve at Low Frequency Perturbation (저주파 압력섭동에서 글로브 제어밸브의 유효 단면적에 따른 임피던스 특성 변화 해석)

  • Park, Seungsoo;Yoon, Woongsup;ohm, Wonsuk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.718-723
    • /
    • 2017
  • In this paper, Analytical study is carried out on the impedance characteristics of the globe control valve, which is mainly used for thrust control in liquid rockets, according to the effective area at low frequency perturbation. The impedance tends to increase according to effective area and the cause of impedance characteristic change through flow field visualization is investigated. In the future, the information on the change in the impedance characteristics of the control valve can be used to obtain the impedance of the supply system and it can be utilized to predict pogo phenomenon as well as design accumulator and orifice to reduce the pogo phenomenon.

  • PDF

Development of the S/G TSP Clogging Image Analysis Algorithm (증기발생기 유로홈막힘 사진판독 알고리즘 개발)

  • Cho, Nam Cheoul;Kim, Wang Bae;Moon, Chan Kook
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.8-14
    • /
    • 2011
  • The clogging of the flow area at the tube support plates(TSPs), especially at the upper TSPs results in the water level oscillation of a steam generator during normal operation. A reduction of the TSP flow area causes to increase in pressure drop within the two-phase flow zone, which destabilizes the boiling flow through the tube bundle. This phenomenon was occasionally observed at a few domestic and foreign nuclear power plants. One of the methods for defining the flow area clogging is visual inspection, which is the most effective inspection method. The results of the visual inspection for TSPs' flow area are clogging images on TSPs' quartrefoil lobes. These images are complexly distorted due to lens aberration and external factors like the distance to a subject and angle etc. In this work, we developed the analysis algorithm for clogging image of the TSP flow area of steam generators. For this purpose, we designed an image verification device applicable to the camera employed in the field for visual inspection and then, we demonstrated the validity of image analysis algorithm by using this device and commercial autoCAD program.

Performance Analysis of a Reciprocating Compressor using a CFD (CFD를 이용한 왕복동압축기 성능해석)

  • Park, W.S.;Hur, N.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.441-447
    • /
    • 2001
  • This paper presents numerical method of investigating flow characteristics of reed valves of reciprocating compressors. The numerically determined effective flow areas agreed within $5.4\%$ of those obtained from experimental measurements. Reasonably good agreements between the experimental and numerical results have been found, implying that the effective flow and force areas of reed valves could be obtained by CFD alone with enough accuracy. A computer simulation of reciprocating compressor has been performed using a numerical results of reed valves. The calculated P-V diagram shows a good agreement with experimental result.

  • PDF