• 제목/요약/키워드: Eddy Current Inspection

검색결과 94건 처리시간 0.02초

Defect Shape Recovering by Parameter Estimation Arising in Eddy Current Testing

  • Kojima, Fumio
    • 비파괴검사학회지
    • /
    • 제23권6호
    • /
    • pp.622-634
    • /
    • 2003
  • This paper is concerned with a computational method for recovering a crack shape of steam generator tubes of nuclear plants. Problems on the shape identification are discussed arising in the characterization of a structural defect in a conductor using data of eddy current inspection. A surface defect on the generator tube ran be detected as a probe impedance trajectory by scanning a pancake type coil. First, a mathematical model of the inspection process is derived from the Maxwell's equation. Second, the input and output relation is given by the approximate model by virtue of the hybrid use of the finite element and boundary element method. In that model, the crack shape is characterized by the unknown coefficients of the B-spline function which approximates the crack shape geometry. Finally, a parameter estimation technique is proposed for recovering the crack shape using data from the probe coil. The computational experiments were successfully tested with the laboratory data.

Detectability evaluation of the loose parts in steam generator by eddy current testing techniques

  • Kim, Kyungcho;Min, Kyongmahn;Kim, Changkuen;Kim, Jin-Gyum;Jhung, Myungjo
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1160-1167
    • /
    • 2018
  • Detectability of the loose parts (LPs) in steam generator (SG) was studied with eddy current testing technique such as X-probe, bobbin and rotating coils ($MRPC^{(R)}$) as a function of LP size and spacing between LP and tube or between LP and support structures. SG mockup simulating SG tube and support structures with LP was fabricated. The X-probe showed slightly better detectability than $MRPC^{(R)}$ for LP of ferrous (F-LP) material and vice versa for LP of nonferrous (NF-LP) material. In terms of feasibility, inspection rate and other predictable features of the SG tubing inspections, X-probe can be used reliably for monitoring the LPs and the flaws formed by LPs on SG tubes.

Stainless강(鋼) 전열관(傳熱管)에 있어서 과전류(過電流) 신호강도(信號强度)와 결함(缺陷)크기와의 관계에 관한 연구(硏究) (A study on the Relationship between the Size of Defect and the Intensity of Eddy Current Signal in Heat Exchanging Tube made of STS 304.)

  • 한응교;엄호섭;박익근;최명식
    • 비파괴검사학회지
    • /
    • 제6권2호
    • /
    • pp.7-16
    • /
    • 1987
  • Eddy Current Examination is expected as the effective technique for nondestructive inspection of steam generator and various kinds of heat exchanging tubes made of STS - 304. In Case of E. C. T, a study on the various factors which have an effect on coil impedance is very important to the sensitivity of defect detection and the ratio of signal to noise. Therefore, this study analyzed coil impedance by means of the variational principle, the minimized theory of energy functional and the application of Finite Element Method. Really by using E. C. T, the relationship between the size of defects and the intensity of Eddy Current Signals can be obtained. Signal intensity becomes maximum at certain frequency. This frequency is affected by the characteristics and the position of signal sources.

  • PDF

Fuzzy Syntactic Pattern Recognition Approach for Extracting and Classifying Flaw Patterns from and Eddy-Current Signal Waveform

  • Kang, Soon-Ju
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권4호
    • /
    • pp.59-65
    • /
    • 1997
  • In this paper, a general fuzzy syntactic method for recognition of flaw patterns and for the measurement of flaw characteristic parameters for a non-destructive inspections signal, called eddy-current, is presented. Solutions are given to the subtasks of primitive pattern selection, signal to symbol transformation, pattern grammar formulation, and event-synchronous flaw pattern extraction based on the grammars. Fuzzy attribute grammars are used as the model for the pattern grammar because of their descriptive power in the face of uncertain constraints caused by nose or distortion in the signal waveform, due to their ability to handle syntactic as well as semantic information. This approach has been implemented and the performance of eh resultant system has been evaluated using a library of law patterns obtained from steam generator tubes in nuclear power plants by an eddy current-based non-destructive inspection method.

  • PDF

연속된 배관의 결함 검출을 위한 개폐식 와전류 탐촉자 개발 (Development of Open-Connect Type Eddy Current Transducers for the Detection of Surface Flaws in Continuous Pipeline)

  • 김영주;안봉영;이승석
    • 비파괴검사학회지
    • /
    • 제22권2호
    • /
    • pp.187-192
    • /
    • 2002
  • 서로 연결되어 있는 강관의 결함을 검사할 수 있도록 하기 위한 개폐식 탐촉자를 제작하였다. 본 탐촉자는 기존의 외삽형 와전류 탐촉자로서는 탐상이 불가능한 설치 가동중인 튜브류의 검사를 위한 것이다. 리본 케이블과 커넥터로 구성된 여기 코일은 접합/단락이 가능하게 하였으며 감지 코일은 튜브 외벽 근처에 원주 방향으로 어레이 형태로 배치하였는데 여기 코일로부터 튜브 직경의 약 1.5배정도 떨어진 위치이다. 제작된 탐촉자를 강관에 적용한 결과, 감도나 결함 크기 구분 등의 성능은 자기 포화형 탐촉자에 미치지 못하나 비교적 큰 결함의 발견이나 위치 파악 등에는 적용 가능한 것으로 나타났다. 크랙 형태의 표면 결함의 경우 두께의 19% 이상의 결함을 찾을 수 있었다.

PGSFR 가동중검사기술 개발 (Development of In-Service Inspection Techniques for PGSFR)

  • 김회웅;주영상;이영규;박상진;구경회;김종범;김성균
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.93-100
    • /
    • 2016
  • Since the sodium-cooled fast reactor is operated in a hostile environment due to the use of liquid sodium as its coolant, advanced techniques for in-service inspection are required to periodically verify the integrity of the reactor. This paper presents the development of in-service inspection techniques for Proto-type Generation IV Sodium-cooled Fast Reactor. First, the 10 m long plate-type ultrasonic waveguide sensor has been developed for in-service inspection of reactor internals, and its feasibility was verified through several under-water and under-sodium experiments. Second, the combined inspection system for in-service inspection of ferromagnetic steam generator tubes has been developed. The remote field eddy current testing and magnetic flux leakage testing can be conducted simultaneously by using the developed inspection system, and the detectability was demonstrated through several damage detection experiments. Finally, the electro-magnetic acoustic transducer which can withstand high temperature and be installable in the remote operated vehicle has been developed for in-service inspection of the reactor vessel, and its detectability was investigated through damage detection experiments.

비파괴검사 전용 시뮬레이터를 이용한 와전류검사 신호 시뮬레이션 (Simulation of Eddy Current Testing Signals Using Simulation Software Dedicated to Nondestructive Testing)

  • 이태훈;조찬희;이희종
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.75-81
    • /
    • 2014
  • A simulation of eddy current testing has been utilized for predicting the signal characteristics to the various defects and developing the probes. Especially, CIVA which is a simulation tool dedicated to nondestructive testing has a good accuracy and speed, and provides a three-dimensional graphical user interface for improved visualization and familiar data displays consistent with NDE technique. Although internal validations have been performed by the CIVA software development specialists, an independent validation study is necessary for the accuracy assessment of the software prior to practical use. For this purpose, in this study, eddy current testing signals of ASME FBH calibration standard tube for bobbin probe were simulated using CIVA and the results were compared to the experimental inspected signals based on the relationship between each flaw signal in terms of amplitude and phase, and the shape of the Lissajous curve. And then we verified the accuracy of the simulated signals and the possible range for simulation. Overall, there is a good qualitative agreement between the CIVA simulated and experimental results in the absolute and differential modes at the two inspection frequencies.

배열와전류프로브를 이용한 증기발생기 세관의 결함 변화에 따른 유한요소해석 (Finite Element Method Analysis of Eddy Current Array Probe According to Defects Variation of Steam Generator)

  • 김지호;이향범
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.54-58
    • /
    • 2009
  • In this paper, the ECT(eddy current testing) signal analysis of eddy current array probe for inspection of SG(steam generator) tube in NPP(nuclear power plant) using electromagnetic FEM(finite element method) was performed. To obtain the electromagnetic characteristics of probes, the governing equation was derived from Maxwell's equation, and the problem was solved by using the 3-dimensional FEM. The types of defects were FBH(flat bottomed hole) and OD groove, Spiral groove, natural defects(pitting, SCC, multiple SCC, wear). The depth of FBH defects were 20%, 40%, 60%, 80%, 100 of SG tube thickness, and it was assumed that the defects were located on the tube outside. And the operation frequency of 100kHz, 300kHz and 400kHz were used. Material of specimen was Inconel 600 which is usually used for SG tubes in NPP. The signal difference could be observed according to the variation of size and depth on FBH defects and operation frequencies. The results in this paper can be helpful when the ECT signals from EC array probe are evaluated and analyzed.

  • PDF

자동차용 볼트의 검사를 위한 시뮬레이션에 기반한 ECT 센서 설계 및 실험적특성 (Experimental Approach and Simulation-Based Design of Eddy Current Sensors for Inspection of Vehicular Bolts)

  • 임광희;이슬기;김학준;송성진;우용득;나승우;이형호
    • 한국생산제조학회지
    • /
    • 제24권3호
    • /
    • pp.294-301
    • /
    • 2015
  • Oil filters for vehicular parts are used under high and low temperatures as the engine is cooled, and defects can be generated with repeated changes in the operating environment and with changes in the shape, such as very high internal losses for the bolts. Visually checking for defects inside a bolt is impossible. Nondestructive evaluation methods such as eddy current testing (ECT) are recommended as a more effective way to examine inside a bolt and detect surface defects in a short amount of time. In this study, the fit bobbin coil eddy current probe was applied to checking the bolts. The bolt parameters were calculated by using a COMSOL analysis program to obtain parameters for professional interior design and fault diagnosis.