• Title/Summary/Keyword: Economical operation condition

Search Result 64, Processing Time 0.028 seconds

An Empirical Study on the Operation of Cogeneration Generators for Heat Trading in Industrial Complexes

  • Kim, Jaehyun;Kim, Taehyoung;Park, Youngsu;Ham, Kyung Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.29-39
    • /
    • 2019
  • In this study, we introduce a model that satisfies energy efficiency and economical efficiency by introducing and demonstrating cogeneration generators in industrial complexes using various actual data collected at the site. The proposed model is composed of three scenarios, ie, full - time operation, scenario operated according to demand, and a fusion type. In this study, the power generation profit and surplus thermal energy are measured according to the operation of the generator, and the thermal energy is traded according to the demand of the customer to calculate the profit and loss including the heat and evaluate the economic efficiency. As a result of the study, it is relatively profitable to reduce the generation of the generator under the condition that the electricity rate is low and the gas rate is high, while the basic charge is not increased. On the contrary, if the electricity rate is high and the gas rate is low, The more you start up, the more profit you can see. These results show that even a cogeneration power plant with a low economic efficiency due to a low "spark spread" has sufficient economic value if it can sell more than a certain amount of heat energy from a nearby customer and adjust the applied power through peak management.

Assessment for Vertical Earth Pressure of Roadbeds Applied to Slab Track Structure by Real-scale Loading Tests (실대형 재하시험을 통한 슬래브궤도 노반의 연직토압 평가)

  • Lee, Tae-Hee;Lee, Jin-Wook;Won, Sang-Soo;Lee, Seong-Hyeok
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2057-2063
    • /
    • 2011
  • Recently, concrete slab track is mostly used to satisfy requirements for safety of high-speed train operation and economical efficiency of maintenance. Due to structural characteristics of ballast track structures, roadbeds under the ballast experience a state of high stress. In case of slab track structures, however, its roadbeds place on a condition of low stress less than roadbeds of ballast track structures as increasing of the loading area. In this study, vertical earth pressure under slab track structures was investigated through real-scale loading tests and theoretical analysis to compare with each other.

  • PDF

Inspection of the Diagnosis Report for Life Assessment of Engine Generator (내연발전기 건전성 판정을 위한 종합 진단결과 고찰)

  • Lee, Young-Jun;Ju, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.96-99
    • /
    • 2010
  • This paper presents evaluating procedure for engine generator operated over 13 years which are usually installed at the island and therefore, isolated to the main distribution line. To decide continual operation of the generator, their diagnosis results should guarantee safety running. So the determination of criteria for continual usage or replacement is essential for economical and reliable maintenance. We present all the courses of evaluating the condition which includes the processes from acquiring basic data to comprehensive determination of generators. All the test was applied to serial number 3 generator in Jodo Engine Power Plant.

Clinical Evaluation of the Lung Cancer (폐암의 임상적 고찰)

  • 최순호
    • Journal of Chest Surgery
    • /
    • v.11 no.1
    • /
    • pp.26-34
    • /
    • 1978
  • We observed 82 cases of primary lung cancer clinically and statistically, which had been experienced at the dept. of thoracic surgery, Chonnam University Hospital, during the period of 13 years from 1964 to 1967. The results obtained were as follows: Peak incidence of age was from 5th decade to 6th decade, and the ratio of male to female was 3: 1. The frequency of lung cancer was higher in the heavy smoker than in the lighter smoker, and undifferentiated carcinoma showed low resectability in spite of the shorter clinical duration. Major symptoms were coughing and chest tightness & pain, especially coughing was initial symptom in the majority of patients. Of the 82 cases, operation was performed in the 32 cases [39%], but resection was possible in the 22 cases [27%]. The delaying factors led patients to an inoperable stage were physician’s misdiagnosis of bronchogenic carcinoma due to non-specific symptoms and signs of the patients, old age patients were dependence on herb medicine, and poor economical condition of the patients in our region especially. Basic conditions of treatment in lung cancer were early detection & early surgery, so, chest P-A would be checked per 3 to 6 months interval associated with sputum cytology in the smoker over 45 age routinely.

  • PDF

A Comparison of Operation Characteristics for $3\Phi$Boost/Buck Converter to Inverter Arc Welding Machine (인버터 아크용접기를 위한 3상 승압/강압형 컨버터의 운전특성비교)

  • 최해룡;구영모;채영민;최규하;목형수;김규식;원충연
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.260-264
    • /
    • 1998
  • Three phase Boost/Buck converter which have economical merits and simple control scheme, are analyzed and evaluated through comparative methods and digital simulation for equivalent load. Those play a part of voltage boost/buck as well as power factor correction with single switch. Controller operating in constant and variable frequency is used for rapid output response and stable system condition respectively. Moreover low THD property of single switched converters is available for inverter arc welding machine known as high power and low power factor. So, in this paper a comparison of the characteristics in boost and buck converter is described and then simulation results conforms the merits from point of view of power factor and voltage regulator.

  • PDF

Design improvement and test and evaluation of aluminium carbody of korea high speed rolling stock (한국형 고속전철 시제차량용 알루미늄차체 설계개선 및 시험평가)

  • 이병현;정경렬;박형순
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.154-159
    • /
    • 2003
  • In this paper, the design improvement for high speed train carbody, which made by aluminium alloy, was described. The design improvements was achieved in fields of economical efficiency, extrusion, welding, assembling, etc. This paper also describes the result of carbody test. The purpose of the test is to evaluate an safety under the load and operation condition. This strength test based on KTX and reference code is UIC 566 and JIS E 7105. The test results shows that aluminium carbody structural have enough strength for all part.

  • PDF

Dead Operation Characteristics of Earth Leakage Circuit Breaker for 50[A] Against Surge Voltages (서지전압에 대한 50[A]용 누전차단기의 부동작 특성)

  • 이승칠;장석훈;이복희
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.5
    • /
    • pp.44-52
    • /
    • 1997
  • Electronic circuits with semiconductor and IC are very weak against the surge voltage and currents. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of the earth leakage circuit breaker(ELB) due to the operation of surge protective devices, and the interruption of AC power lines on account of the malfunction of the ELB brings about several disadvantages such as low operation efficiency and reliability of electronic and informational systems, economical loss, and etc. The aim of the present work is to investigate the dead operation characteristics of the ELB against the surge voltages. The impulse generator of 10[kV) in an 1.2/ 50[~) voltage waveform was fabricated. The dead operation characteristics of the ELB applied by surge voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a consequence, the peak value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not bring about dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELB installed at the AC power lines with the surge protective devices bring about the dead operation.

  • PDF

A Study on Characteristic of NO Reduction by High Level O2Gas in Selective Non-Catalystic Reaction (High Level O2배가스중 NO 저감에 대한 선택적비촉매환원 반응특성에 관한 연구)

  • 이강우;정종현;오광중
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.577-582
    • /
    • 2002
  • Selective catalytic reduction and selective non-catalytic reduction processes are mainly used to treat nitrogen oxidants generated from fossil-fuel combustion. Especially, the selective non-catalytic reduction process can be operated more economical and designed more simply than the selective catalytic reduction. For this reason, many researchers carried out to increase the removal efficiency of nitrogen oxidants in the condition of low oxygen concentration by using the selective non-catalytic reduction process. However, this study was flue gas contained high oxygen concentration of 20(v/v%) with ammonia as a reducing agent. Moreover, it carried out experiment with many factors that are reaction temperature, retention time, initial NO concentration, NSR(normalized stoichiometric ratio). It was determined optimal operating conditions to improve NO removal efficiency with SNCR process. The De-NOx efficiency was increased with NSR, initial NO concentration and retention time increasement. This study has NO removal efficiency over 80% in the high oxygen concentration as well as low oxygen concentration. The injection of reducing agent may be considered for SNCR process and facility operation in 850$\^{C}$ of optimal condition.

Application of Electrochemical Method for Decolorization of Biologically Treated Animal Wastewater Effluent (생물학적 축산폐수 처리수 색도제거를 위한 전기화학적 방법의 적용)

  • 윤성준;신종서;라창식
    • Journal of Animal Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.315-324
    • /
    • 2006
  • This research was conducted to clarify the characteristics of electrochemical decolorization of effluent discharged from a biological animal wastewater treatment process and to finally establish parameters or mode for optimum operation of electrolysis system. Average color unit of wastewater was about 1,200 and DSA(Dimensionally Stable Anode) was used as electrode. Experiments were performed with two different operation conditions or modes, fixed voltage-free current(Run A) and free voltage-fixed current(Run B). Color removal rate was proportional to the electrode area and electrical conductivity, and an equation subject to them at a condition of fixed voltage was derived as follows; Ct=C0ekt, k=[{0.0121×a(dm2)× c(mS/cm)}+0.0288], [where, C0: initial color, Ct: color unit after treatment for t, k: reaction coefficient, t: time(min.), a: electrode area, c: conductivity]. From the study on the effects of current density on color removal, it was revealed that the removal efficiency of color was function of the current density, showing direct proportion. However, when considered energy consumption rate, maintenance of low current density was an economical way. Based on the obtained results, it was concluded that supplementation of electrolyte is not necessary for the removal of color from the effluent of secondary treatment process and operation with the mode of free voltage-fixed current, rather than operation with fixed voltage-free current mode, would be an efficient way to increase the removal performance and capacity per consumed energy.

Simulation Analysis of Sludge Disposal and Volatile Fatty Acids Production from Gravity Pressure Reactor via Wet Air Oxidation (습식산화반응을 통한 중력식반응기로부터의 슬러지 처리 및 유기산 생산 공정모사)

  • Park, Gwon Woo;Seo, Tae Wan;Lee, Hong-Cheol;Hwang, In-Ju
    • Korean Chemical Engineering Research
    • /
    • v.54 no.2
    • /
    • pp.248-254
    • /
    • 2016
  • Efficacious wastewater treatment is essential for increasing sewage sludge volume and implementing strict environmental regulations. The operation cost of sludge treatment amounts up to 50% of the total costs for wastewater treatment plants, therefore, an economical sludge destruction method is crucially needed. Amid several destruction methods, wet air oxidation (WAO) can efficiently treat wastewater containing organic pollutants. It can be used not only for sludge destruction but also for useful by-product production. Volatile fatty acids (VFAs), one of many byproducts, is considered to be an important precursor of biofuel and chemical materials. Its high reaction condition has instituted the study of gravity pressure reactor (GPR) for an economical process of WAO to reduce operation cost. Simulation of subcritical condition was conducted using Aspen Plus with predictive Soave-Redlich-Kwong (PSRK) equation of state. Conjointly, simulation analysis for GPR depth, oxidizer type, sludge flow rate and oxidizer injection position was carried out. At GPR depth of 1000m and flow rate of 2 ton/h, the conversion and yield of VFAs were 92.02% and 0.17g/g, respectively.