• Title/Summary/Keyword: Economical operation

Search Result 500, Processing Time 0.027 seconds

Operation of High Performance Elutriation-Type Sludge Fermenter and Feasibility for Its Application (고성능 세정식 슬러지 산발효조의 운전 및 적용성 평가)

  • Ahn, Young-Ho;Speece, R.E.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.85-92
    • /
    • 2005
  • The performance of a novel fermentation process, adopting a sludge blanket type configuration for higher hydrolysis/acidogenesis of the municipal primary sludge, was investigated under batch and semi-continuous conditions with various pH and temperature conditions. This acid elutriation slurry reactor provided higher system performance with a short HRT (5 days) and higher acidogenic effluent quality under pH 9 and thermophilic ($55^{\circ}C$) conditions. The hydrolysis of the sludge was revealed to be significantly dependent on seasonal effects for sludge characteristics but with little impact on acidogenesis. Based on the rainy season at the optimum conditions, VFA production and recovery fraction ($VFA_{COD}/COD$) were $0.18\;g\;VFA_{COD}\;g^{-1}\;VSS_{COD}$ and 63%. As byproducts, nitrogen and phosphorus releasing were $0.006\;g\;N\;g^{-1}\;VSS_{COD}$ and $0.003\;g\;P\;g^{-1}\;VSS_{COD}$, respectively. For the mass balance in a full-scale plant($Q=158,880\;m^3\;day^{-1}$) based on the rainy season, the VFA and non-VFA(as COD) production were $3,110\;kg\;VFA_{COD}\;day^{-1}$ and $1,800\;kg\;COD\;day^{-1}$, resulting in an increase of organics of $31\;mg\;COD\;L^{-1}$ and $20\;mg\;VFA_{COD}\;L^{-1}$ and nutrients of $0.7\;mg\;N\;L^{-1}$ and $0.3\;mg\;P\;L^{-1}$ in the influent sewage. The economical benefit from this process application was estimated to be about $67 per $1,000m^3$ of sewage except for energy requirements and also, better benefits can be expected during the dry season. Also, the results revealed that the process has various additional advantages such as pathogen-free stabilized solids production, excellent solids control and economical benefits.

A Study of School Waste Disposal Status and Its Reforms (Public Primary and Secondary Schools in Seoul) (학교 쓰레기 처리현황과 개선에 관한 연구 - 서울시 공립 초.중등학교를 대상으로 -)

  • 노성빈
    • Hwankyungkyoyuk
    • /
    • v.3 no.1
    • /
    • pp.130-140
    • /
    • 1992
  • The purpose of this study was to survey the trends of waste products in schools, its gathering and disposal, identification of problems and to analyze its disposal. Moreover, this study was aimed at basic suggestions about the establishment and plans of waste environmental education. 98 public primary and secondary schools were surveyed in Seoul during the month of March and April, 1991. Information was collected from each educational association by random sampling. Questionaries were used for this survey. To understand the disposal status of school waste and its reforms, this study surveyed the amount of waste by products, their origin and analyzed the disposal by type, one number of schools and teachers involved. The dump sited and disposal methods of school waste, its problems, and the status of school waste educations were researched, and ideal disposal methods and plans for waste education were suggested. The results were as follows. 1. The School's trash was produced by followings: paper, vinyle plastics, food, woods, metals, ceramics, glass, bottles, and ash from the heating system. The biggest cause of the school's waste as shown by the survey was a lack of environmental awareness(39.8%). The second biggest was the use of a one time use of disposable paper products(27.6%). 2. Waste collection by different grade levels were proven to be important but as you move from elementary to high school, the waste collecting operation decreased, in this connection between the students and waste collection itself it was significant on the other hand the teachers were not working as significant variables. 3. Of the school that collected waste 69.5 percent of the schools separately grouped common waste and recyclable waste. 25 schools(42.4%) received improvement on their environmental awareness of trash collection through this method. 4. From the number of disposal sites in surveyed schools, it was determined that the education of the necessity for separation of waste was performed in vain and accordingly the should require a real education in the future. 5. Regarding the method of disposal of waste the survey indicated that the #1 method of disposal was partial burning and the remains carried to a dump site by others(35,7%). In elementary schools the entire waste was taken by individuals to a dump site (33.3%). In high schools partial burning and then transported by individuals #1 in our survey(50%). 6. Relative to the problem of the treatment to waste, the emission of smoke from the burning was considered to be the #1 priority in our survey (62.3%) the problem of trash collection being delayed was 52.1%(1in our survey). 7. The present situation of environmental education of waste us lacking. Under present circumstances, the practice of public announcements for improvement and waste-paper collection has been going on vigorously but lacking in education as to the preparation of compositions for students the themes of public exhibitions, the organizing of voluntary associations should be part of the education system to reinforce student's awareness of proper waste disposal. 8. The most economical alternative for disposal was recycling usable waste or combustible material through a variety of education we can therefore educate students bring this education to their homes public servants will also be able to benefit in the waste disposal process with proper education. In conclusion we should intensify the systemical organization and the education of our waste disposal for a better environment.

  • PDF

A Study on the Evaluation of Materials for Aircraft Turbofan Engine Using Data Base. (항공기용 터어보팬 엔진의 재료선정용 DATA BASE를 이용한 재료평가에 관한 연구)

  • Kim, Gwang-Bae;Bu, Jun-Hong;Kim, Hak-Bong;Im, Gyeong-Ho;Yu, Sang-Sin
    • Korean Journal of Materials Research
    • /
    • v.1 no.3
    • /
    • pp.156-167
    • /
    • 1991
  • The purpose of this study is to develop a data base for material selection of turbofan engines, which is preferred in these days on many application due to their high performance with economical operation. Hundreds of Super Alloys have been developed by this time, each having special properties. Since it is very difficult task for a design engineer to select materials of adequate Properties for specific engine components, a good data bate is strongly desired to manage informations on various kinds of materials. However, no basic research is reported in this area so far in our country. The operating conditions such as temperature, pressure, rpm of spools are assumed to be provided by other mechanical studies. Creep rupture strength, corrosion resistance, yield strength, thermal expansion, melting point, etc., are considered as typical properties in this study to search a group of candidate materials. Formability, manufacturing or purchase cost can also be important variables to be considered. As a result of this study, a user-friendly computer program has been developed for input of new material information, interactive material selection, and output of selection results. Finally, discussion is presented from. the viewpoint of materials engineering. A method to evaluate the performance of the selected materials is also suggested.

  • PDF

A Study on the Introduction and Application Plan of the Mobile Saturation Diving System for ROK Navy Salvage Operations (한국 해군의 해난구조작전을 위한 이동식 포화잠수체계 도입 및 활용방안에 관한 연구)

  • Yu, Ho-Hwi;Kang, Sin-Young;Lim, An
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.4
    • /
    • pp.389-396
    • /
    • 2015
  • This study examined how to improve the Korean Navy diving system, particularly focused on using the mobile saturation diving system. This study determined the range of navy operations, and suggested requirements of mobile saturation diving system from the analysis of previous study and current Navy Diving system. Also, this study examined the use of military strategy in terms of its technical and applicable possibility for the enhancement of current system. In addition, the study analyzed both advantages/disadvantages of importing mobile saturation diving system products and domestic development. To review measures in installing and operating such system, this study included analysis on the effectiveness of individual platform. As the result, the study suggested requirements of mobile saturation diving system to be able to be operated by more than 6 divers for more than 17 days at more than 200m depth. And the study confirmed that there are beneficial to use mobile saturation diving system and current Navy saturation diving system together. However, it is low economical efficiency to change current Navy gas diving system to Saturation diving system. To review measures in installing and operating such system, this study suggested that second ATS-II should be built to be able to install mobile saturation diving system. Also, this study generated an utilization method of the system to use it for training when peacetime, and than it should be installed on other platform to use as additional salvage strength during wartime.

Maximum Power Point Tracking operation of Thermoelectric Module without Current Sensor (전류센서가 없는 열전모듈의 최대전력점 추적방식)

  • Kim, Tae-Kyung;Park, Dae-Su;Oh, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.436-443
    • /
    • 2017
  • Recently, the development of new energy technologies has become a hot topic due to problems,such as global warming. Unlike renewable energy technologies, such as solar energy generation, solar power, and wind power, which are optimized to achieve medium or above output power, the output power of energy harvesting technology is very small and has not received much attention. On the other hand, as the mobile industry has been revitalized recently, the utility of energy harvesting technology has been reevaluated. In addition, the technology of tracking the maximum power point has been actively researched. This paper proposes a new MPPT(Maximum Power Point Tracking) control method for a TEM(thermoelectric module) for load resistance. The V-I curve characteristics and internal resistance of TEM were analyzed and the conventional MPPT control methods were compared. The P&O(Perturbation and Observation) control method is more accurate, but it is less economical than the CV (Constant Voltage)control method because it usestwo sensors to measure the voltage and current source. The CV control method is superior to the P&O control method in economic aspects because it uses only one voltage sensor but the MPP is not matched precisely. In this paper, a method wasdesigned to track the MPP of TEM combining the advantages of the two control method. The proposed MPPT control method wasverified by PSIM simulation and H/W implementation.

Performance Evaluation of the Field Scale Sequential Washing Process for the Remediation of Arsenic-Contaminated Soils (Field 규모 연속 토양세척공정을 이용한 비소 오염토양 정화 효율 평가)

  • Choi Sang Il;Kim Kang Hong;Han Sang-Keun
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.6
    • /
    • pp.68-74
    • /
    • 2005
  • This study was carried out to evaluate the feasibility of field-scale sequential soil washing process for remediation on Kyongsangnamdo D mine soils which was heavily contaminated by arsonic. Arsenic concentration of untreated soils was $321\pm32mg/kg$. By applying the basic operating condition which was proposed from several pilot-scale experiments, arsenic concentration of treated soils was reduced 2.04 mg/kg ($99\%$ removal efficiency). We optimized the basic operating condition (mainly on washing solution concentration, cut-off size, and mixing ratio) to improve efficiently and economically the field-scale sequential soil washing process. The resulting optimized conditions were that solution concentration is 0.2M HCl, 1.0M HCl, 1.0M NaOH, that the cut-off size is 0.15mm (seive $\sharp$100), and that the mixing ratio is 1 3. Also, the optimized pH value for soil washing effluent treatment was 6 (33 ppb), in which the precipitation disruption caused by supersaturation of the floe did not occur. Results of TCLP tests showed that arsenic concentration from the washed gravels was 1.043 mg/L, that from soils ND (not detected), and that from filter cakes 0.066 mg/L. Also, the water content as a percentage of dewatered sludges was low $(48\%)$ and so the dewatered sludges can be disposed by landfilling. Through these results, we can concluded that tile field-scale sequential soil washing process developed in this study is adopted for remediation of arsenic-contaminated soils.

Forecasting Air Freight Demand in Air forces by Time Series Analysis and Optimizing Air Routing Problem with One Depot (군 항공화물수요 시계열 추정과 수송기 최적화 노선배정)

  • Jung, Byung-Ho;Kim, Ik-Ki
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.5
    • /
    • pp.89-97
    • /
    • 2004
  • The Korea Air Force(KAF) has operated freight flights based on the prefixed time and route schedule, which is adjusted once in a month. The major purpose of the operation of freight flights in the KAF is to distribute necessary supplies from the home air base to other air bases. The secondary purpose is to train the young pilots to get more experiences in navigation. Each freight flight starts from and returned to the home air base everyday except holidays, while it visits several other air bases to accomplish its missions. The study aims to forecast freight demand at each base by using time series analysis, and then it tried to optimize the cost of operating flights by solving vehicle routing problem. For more specifically, first, several constraints in operating cargos were defined by reviewing the Korea Air Force manuals and regulation. With such constraints, an integer programming problem was formulated for this specific routing problem allowing several visits in a tour with limitation of maximum number of visits. Then, an algorithm to solve the routing problem was developed. Second, the time series analysis method was applied to find out the freight demand at each air base from the mother air base in the next month. With the forecasted demands and the developed solution algorithm, the oprimum routes are calculated for each flight. Finally, the study compared the solved routing system by the developed algorithm with the existing routing system of the Korea Air Force. Through this comparison, the study proved that the proposed method can provide more (economically) efficient routing system than the existing system in terms of computing and monetary cost. In summary, the study suggested objective criteria for air routing plan in the KAF. It also developed the methods which could forecast properly the freight demands at each bases by using time series analysis and which could find the optimum routing which minimizes number of cargo needed. Finally, the study showed the economical savings with the optimized routing system by using real case example.

Real-time Environmental Radiation Monitoring System with Automatic Restoration of Backup Data in Site Detector via Communication using Radio Frequency (현장검출기에 저장된 백업데이터를 무선통신방식으로 자동 복원하는 실시간 환경선량 감시 시스템)

  • Lee, Wan-No;Kim, Eun-Han;Chung, Kun-Ho;Cho, Young-Hyun;Choi, Geun-Sik;Lee, Chang-Woo;Park, Ki-Hyun;Kim, Yun-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.255-261
    • /
    • 2003
  • An environmental radiation monitoring system based on high pressurized ionization chamber has been used for on-line gamma monitoring surrounding the KAERI (Korea Atomic Energy Research Institute), which transmits the dose data measured from ion chamber on the site via radio frequency to a central processing computer and stores the transmitted real-time data. Although communication using radio frequency has several advantages such as effective and economical transmission, storage, and data process, there is one main disadvantage that data loss during transmission often happens because of unexpected communication problems. It is possible to restore the loss data by off-line such as floppy disk but the simultaneous process and display of current data as well as the backup data are very difficult in the present on-line system. In this work, a new electronic circuit board and the operation software applicable to the conventional environmental radiation monitoring system are developed and the automatical synchronization of the ion chamber unit and the central processing computer is carried out every day. This system is automatically able to restore the backup data within 34 hours without additional equipments and also display together the current data as well as the transmitted backup data after checking time flag.

A Comparative Study of Economical Efficiency in Apartment Security System: Focused on a Enhancing the Effectiveness of Senior Employment Programs (아파트 유·무인 경비시스템의 경제성 비교 연구: 노인일자리 사업의 효용성 제고를 중심으로)

  • Ha, Jai-Ryong;Lee, Kwang-Won
    • Korean Security Journal
    • /
    • no.41
    • /
    • pp.7-36
    • /
    • 2014
  • Recently the Korean government announced that minimum wage policy would be applied even to apartment security staffs by 2015 who had been waived from the policy enforcement for their unique work conditions. This caused apartment management to introduce unmanned security system instead of employing security staffs because of fearing possible hike of management fees. People recklessly tend to believe unmaned system is cheaper than maned system if minimum wage guideline is applied. This study examines the economic feasibility of two different apartment security systems by utilizing cost-benefit analysis: maned and unmaned security systems. The authors estimate the costs and the benefits of each security system for 5 years(2014-2018) with application of social discount rate(5.5%). Thirty six apartment complexes at 8 different areas(meons and dongs) in Asan, Chungcheongnam-do province were surveyed. And to attain the exact costs of unmaned system establishment and operation, the authors interviewed persons working for the unmaned security corporations. The benefit-cost(B/C) ratio for unmanned security system is 1.66% at minimum and 1.30% at maximum. while B/C ratio for manned security system is 1.42% and 1.66% respectively. This results mean that people's belief is not correct, that is, transferring from maned system to unmaned is not always economically efficient. Benefits of maned security system is more diverse than unmaned system. The former provides living conveniences(parking helps and keeping parcels) and social benefits(employing aged worker and giving them opportunities to enjoy happier lives) as well as security benefits like crime prevention. The latter provides security benefits only, but that effect is also doubtable. Taking into account these diverse benefits maned system provides, the B/C ratio of maned system is equitable or higher than unmaned system.

  • PDF

A Study on an Improvement for Management System of Municipal Sewage Sludge through an investigation of MSS Treatment Facilities (하수오니 처리시설 현황분석을 통한 처리체계 개선 방안 연구)

  • Kim, Young-Koo;Phae, Chae-Gun;Ryu, Don-Sik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.2
    • /
    • pp.121-128
    • /
    • 2006
  • In this study, the existing MSS facilities were investigated for examination the the present condition of MSS treatment system. There are 23 MSS treatment facilities across the country, In total facilities, 6 facilities have economical problems, and 2 facilities were stopped the operation of establishments for technical problems, and most facilities are suffering from environmental problems, for example, odor and waste water. These kinds of problems play a role as obstacle to treat MSS efficiently. Accordingly, to reform current MSS treatment system, a few adequate measures are required. First a Guide line, which is a manual for establishment of MSS treatment facilities efficiently and environmentally friendly, must be offered from the agencies concerned of the Ministry of Environment to local governments. Second, to devise a plan for MSS treatment, Ministry of Environment and all local governments should devise a long-range policy synthetically not fragmentarily and temporarily.

  • PDF