• Title/Summary/Keyword: Eccentric Moment

Search Result 94, Processing Time 0.028 seconds

Evaluation of Analysis Technique for Piles Driven by Vibration through Parametric Study (매개변수연구를 통한 진동타입말뚝 해석기법 평가)

  • Lee, Seung-Hyun;Lee, Su-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1749-1755
    • /
    • 2014
  • Technique for analyzing a pile installed by vibrohammer was developed and parametric studies were executed in order to evaluate reliability of the developed technique. Comparing the accelerations obtained from parametric studies of varying eccentric moment and frequency, it can be seen that magnitude of maximum acceleration was proportional to the eccentric moment and square of frequency. It can also be seen that amplitude of displacement was roughly proportional to the eccentric moment but has nothing to do with the frequency. It can be said that all of the analysis results reflect characteristics of behavior of a pile in case of free vibration. Comparing the dynamic load transfer curves, maximum dynamic unit toe resistance was constant regardless of the eccentric moment and the frequency and it can be seen that dynamic unit skin friction was affected by the eccentric moment not by frequency. Comparing all of the analysis results, it can be said that the developed technique is reliable.

Buckling Experiment of Eccentric Seismic Bracing Devices for Branch Lines (내진설계용 편심방식 가지배관 고정장치의 좌굴 실험)

  • Changsoo, Oh;Jihoon, Kim;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.9-14
    • /
    • 2024
  • Restraints of Branch Lines are used as earthquake-resistant support devices for fire-fighting pipes along with sway brace devices. The central types are aligned and fixed in a straight line with center of the pipe, but the eccentric types are fixed to on side of the pipe, so a bending moment occurs. In this study, three specimens each of central type and eccentric type were installed at an angle of 45° from the vertical and a monotonic compression load of 1340N was applied. All central type samples satisfied 17.8mm of the allowable displacement, but all eccentric type samples failed to meet the target load and buckled. Therefore, when considering the performance of eccentric type restraints, both compressive load and bending moment must be considered. Even through material mechanics calculations, the yield stress of eccentric type - 3/8 inch all threaded steel bolt - exceeds 320Mpa of the allowable stress. A experiment standards need to be established for eccentric type restraints.

Strength Model for Eccentric Shear of Flat Plate-Column Connections under Unbalanced Moment (불균형 휨모멘트를 받는 플랫플레이트-기둥 접합부의 편심전단강도)

  • Choi Kyoung-Kyu;Park Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.229-240
    • /
    • 2004
  • Many experiments have been performed to investigate eccentric shear strength and unbalanced moment-carrying capacity of flat plate-column connections under combined gravity and lateral load. However, each existing experiment used different test setup, and the shear strength of the connection was different depending on the test setup. Current design methods which were based on the experimental results might not accurately explain the shear strength of the flat plate. In a companion study, based on results of nonlinear finite element analyses, an alternative design method for the plate-column connection was developed. However, in this method, eccentric shear strength of the connection which was required for assessing unbalanced moment-carrying capacity was evaluated by an empirical formula. In the present study, a theoratical approach using Rankine's failure criterion was attemped to investigate failure mechanism of the eccentric shear. Based on the results, an improved strength model of the eccentric shear was developed, and it was verified by comparison with the existing experimental results. By means of the strength model, the design method developed in the companion study was re-verified.

Biomechanical Alternation of the Elderly Depending on the Type of Gait Termination (멈춤 유형에 따른 노인 보행의 생체역학적 변화)

  • Yi, Jae-Hoon;Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.2
    • /
    • pp.189-196
    • /
    • 2011
  • The purpose of this study was to verify the difference in biomechanical variation and pattern of the lower limb between planned and unexpected termination, which is related to the prevention of fatal fall in the elderly. Therefore, selected twenty subjects for each group which composed of females(age: $73.5{\pm}4.63$ year, height: $153.2{\pm}6.46$ cm, body mass: $58.98{\pm}5.82$ kg) and women(age: $23.4{\pm}2.5$ year, height: $164.65{\pm}3.9$ cm, body mass: $58.47{\pm}5.53$ kg) in their twenties. As a result, lower limb's extension moment and power were increased significantly in statistics(p<.05). Also, knee joint power showed instant changes from concentric contraction to eccentric contraction and hip joint power from eccentric contraction to concentric contraction. During unexpected termination there were dramatical increase in eccentric contraction and power(p<.05). In both planned and unexpected termination, ankle joint moment were higher in young group, but the moment of the hip joint were higher in the elderly group(p<.05). In contrast to younger group, there were no changes in knee extension moment in elderly group(p<.05). but showed relatively higher hip joint extension moment and power(p<.05).

Capacity and the moment-curvature relationship of high-strength concrete filled steel tube columns under eccentric loads

  • Lee, Seung-Jo
    • Steel and Composite Structures
    • /
    • v.7 no.2
    • /
    • pp.135-160
    • /
    • 2007
  • Recently, CFT column has been well-studied and reported on, because a CFT column has certain superior structural properties as well as good productivity, execution efficiency, and improved rigidity over existing columns. However, CFT column still has problems clearing the capacity evaluation between its steel tube member and high-strength concrete materials. Also, research on concrete has examined numerical values for high-strength concrete filled steel square tube columns (HCFT) to explain transformation performance (M-${\phi}$) when a short-column receives equal flexure-moment from axial stress. Moment-curvature formulas are proposed for HCFT columns based on analytic assumption described in this paper. This study investigated structural properties (capacity, curvature), through a series of experiments for HCFT with key parameters, such as strength of concrete mixed design (58.8 MPa), width-thickness ratio (D/t), buckling length to sectional width ratio (Lk/D) and concrete types (Zeolite, Fly-ash, Silica-fume) under eccentric loads. A comparative analysis executed for the AISC-LRFD, AIJ and Takanori Sato, etc. Design formulas to estimate the axial load (N)-moment (M)-curvature (${\phi}$) are proposed for HCFT columns based on tests results described in this paper.

Load Carrying Capacities of Cold Formed Steel Structural Columns subject to Combined Axial Load and Bending Moment (압축과 휨의 조합하중을 받는 냉간성형강 기둥의 내력성능)

  • Shin, Tae Song
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.1 s.74
    • /
    • pp.83-92
    • /
    • 2005
  • This paper is to evaluate the load carrying capacities of cold-formed steel columns subject to combined axial load and bending moment. A combined strength experiment is carried out using full-scale 24 specimens of lipped channel section with embossment in web. An eccentric axial load is applied in varying member-length and eccentric distance which produces an end-moment of the column. The predictions of the AISI specification and the Eurocode are compared with the experimental results, and it is shown that all of these codes are reasonable on the whole in relation to the experimental results.

Interaction of Flexure-Torsional by eccentric load in horizontal curved 'I' shape girder (편심하중이 작용하는 수평 곡선 I 형 거더의 휨·비틀림 상호작용)

  • Lim, Jeong-Hyeon;Lee, Kee-Sei;Kim, Hee-Soo;Choi, Jun-Ho;Kang, Young-Joung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6385-6390
    • /
    • 2015
  • With bending moment, torsional moment due to geometric properties as "Initial curvature" acts in horizontally curved I-girder. These behavior causes the secondary effect of bending in minor-axis because of interaction between bending and torsion. The bending and torsion interaction cause a loss of load bearing capacity by induced the early inelastic or plasticity condition in curved girder. Also eccentric load by movements of traffic can increase torsion. However, Equation of interaction between bending and torsion for straight girder, not deal with characteristics of curved girder behavior in previous studies, can be overestimated for ultimate strength in horizontally curved I-girder acting vertical force. Therefore, using more rational, obvious suggestion is required when design curved girder. In this study, we identified the bending-torsional moment interaction for the horizontally curved I-girder of the eccentric load acting by FEM analysis.

Analysis of the Differences of the Shock Absorption Strategy between Drop-Landing and Countermovement-Jump (드롭 착지와 착지 후 점프 시 충격흡수 기전의 차이 분석)

  • Cho, Joon-Haeng;Kim, Kyoung-Hun;Koh, Young-Chul
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.4
    • /
    • pp.379-386
    • /
    • 2012
  • The aim of this study was to investigate and identify the differences in lower extremity energy dissipation strategies between drop-landing and countermovement-jump maneuvers. Fourteen recreational athletes(Age : $23.3{\pm}2.1years$, Height : $172.3{\pm}4.0cm$, Weight : $69.2{\pm}4.7kg$) were recruited and instructed to perform drop-landing from 45 cm height and countermovement-jump from 45 cm to 20 cm height. The landing phase was taken as the time between initial contact and peak knee flexion. A motion-capture system consisting of eight infra-red cameras was employed to collect kinematics data at a sampling rate of 200 Hz and a force-plate was used to collect GRF data at a sampling rate of 2000 Hz. Paired t-test was performed to determine the difference in kinematics and kinetics variables between each task. During the countermovement-jump task, all of lower extremity joint ROM and the hip joint eccentric moment were decreased and the ankle joint plantarflexion moment was increased than drop-landing task. In the eccentric work during countermovement-jump task, the ankle joint displayed greater while knee and hip joint showed lesser than drop-landing. Therefore, the knee joint acted as the key energy dissipater during drop-landing while the ankle joint contributed the most energy dissipation during countermovement-jump. Our findings collectively indicated that different energy dissipation strategies were adopted for drop-landing and countermovement-jump.

Minimum area for circular isolated footings with eccentric column taking into account that the surface in contact with the ground works partially in compression

  • Inocencio Luevanos-Soto;Arnulfo Luevanos-Rojas;Victor Manuel Moreno-Landeros;Griselda Santiago-Hurtado
    • Coupled systems mechanics
    • /
    • v.13 no.3
    • /
    • pp.201-217
    • /
    • 2024
  • This study aims to develop a new model to obtain the minimum area in circular isolated footings with eccentric column taking into account that the surface in contact with the ground works partially in compression, i.e., a part of the contact area of the footing is subject to compression and the other there is no pressure (pressure zero). The new model is formulated from a mathematical approach based on a minimum area, and it is developed by integration to obtain the axial load "P", moment around the X axis "Mx" and moment around the Y axis "My" in function of σmax (available allowable soil pressure) R (radius of the circular footing), α (angle of inclination where the resultant moment appears), y0 (distance from the center of the footing to the neutral axis measured on the axis where the resultant moment appears). The normal practice in structural engineering is to use the trial and error procedure to obtain the radius and area of the circular footing, and other engineers determine the radius and area of circular footing under biaxial bending supported on elastic soils, but considering a concentric column and the contact area with the ground works completely in compression. Three numerical problems are given to determine the lowest area for circular footings under biaxial bending. Example 1: Column concentric. Example 2: Column eccentric in the direction of the X axis to 1.50 m. Example 3: Column eccentric in the direction of the X axis to 1.50 m and in the direction of the Y axis to 1.50 m. The new model shows a great saving compared to the current model of 44.27% in Example 1, 50.90% in Example 2, 65.04% in Example 3. In this way, the new minimum area model for circular footings will be of great help to engineers when the column is located on the center or edge of the footing.

Wave load resistance of high strength concrete slender column subjected to eccentric compression

  • Jayakumar, M.;Rangan, B.V.
    • Structural Engineering and Mechanics
    • /
    • v.50 no.3
    • /
    • pp.287-304
    • /
    • 2014
  • A computer based iterative numerical procedure has been developed to analyse reinforced high strength concrete columns subjected to horizontal wave loads and eccentric vertical load by taking the material, geometrical and wave load non-linearity into account. The behaviour of the column has been assumed, to be represented by Moment-Thrust-Curvature relationship of the column cross-section. The formulated computer program predicts horizontal load versus deflection behaviour of a column up to failure. The developed numerical model has been applied to analyse several column specimens of various slenderness, structural properties and axial load ratios, tested by other researchers. The predicted values are having a better agreement with experimental results. A simplified user friendly hydrodynamic load model has been developed based on Morison equation supplemented with a wave slap term to predict the high frequency non-linear impulsive hydrodynamic loads arising from steep waves, known as ringing loads. A computer program has been formulated based on the model to obtain the wave loads and non-dimensional wave load coefficients for all discretised nodes, along the length of column from instantaneous free water surface to bottom of the column at mud level. The columns of same size and material properties but having different slenderness ratio are analysed by the developed numerical procedure for the simulated wave loads under various vertical thrust. This paper discusses the results obtained in detail and effect of slenderness in resisting wave loads under various vertical thrust.