• 제목/요약/키워드: ESS : Energy Storage System

검색결과 402건 처리시간 0.024초

에너지저장장치를 이용한 제주지역 풍력발전 한계용량 증대효과 분석 (Increasing Effect Analysis of the Wind Power Limit Using Energy Storage System in Jeju-Korea)

  • 김영환;김세호
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.81-90
    • /
    • 2014
  • The Jeju-Korea power system is a small-sized network with a system demand ranging from a autumn minimum of 350MW to a summer peak of 716MW. Because Jeju island is well exposed to north-east winds with high speed, applications to connect to Jeju power system are flooded. Considering physical/environmental constraints, Jeju Self-governing Province has also target for the wind power capacity of 1,350MW by 2020. It amounts to two or three times of Jeju average-demand power and wind power limit capacity announced by Korea Power Exchange (KPX) company. Wind farm connection agreements will be signed to maximize utilization of wind resource. In spite of submarine cable HVDC connected to Korea mainland, Jeju power system is independently operated by frequency and reserve control. This study reevaluates wind power limit based on the KPX criteria from 2016 to 2020. First of all wind power generation limit are affected by off-peak demand in Jeju power system. Also the possibility capacity rate of charging wind power output is evaluated by using energy storage system (ESS). As a result, in case of using 110MWh ESS, wind power limit increases 33~55MW(30~50% of ESS), wind power constraint energy decreases from 68,539MWh to 50,301MWh and wind farm capacity factor increases from 25.9 to 26.1% in 2020.

신재생에너지가 연계된 마이크로그리드에서 에너지 저장장치의 최적 용량 선정에 관한 연구 (A Study on Optimal Capacity of Energy Storage System in Renewable Energy Based Micorgrids)

  • 김욱원;이남형;이윤성;신제석;김진오
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.529-533
    • /
    • 2012
  • By introducing RPS(Renewable Portfolio Standard) for reduction of greenhouse gas, Renewable energy sources have becoming widespread gradually. However, Renewable energy sources, such as wind power and PV are difficult to control the output and they have intermittent characteristics of the output. These characteristics would cause some problems when it is connected in the power system. In order to solve these problems, Energy Storage Systems(ESS) are considered to use. Although there are many different storage devices, the utilization of Secondary Battery is the one of the best ways to stabilize an output fluctuation of RES because of its fast responsibility. For that reason, it would better fit a large-capacity of Secondary battery for stabilization. However, batteries cannot be installed with a large capacity blindly because of its expensive cost. So to select proper capacity of the battery is an important consideration. This paper presented a methodology for the optimal capacity and operation of ESS in microgrids.

  • PDF

Transient Characteristics and Physical Constraints of Grid-Tied Virtual Synchronous Machines

  • Yuan, Chang;Liu, Chang;Yang, Dan;Zhou, Ruibing;Tang, Niang
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1111-1126
    • /
    • 2018
  • In modern power systems, distributed generators (DGs) result in high stress on system frequency stability. Apart from the intermittent nature of DGs, most DGs do not contribute inertia or damping to systems. As a result, a new control method referred to as a virtual synchronous machine (VSM) has been proposed, which brought new characteristics to inverters such as synchronous machines (SM). DGs employing an energy storage system (ESS) provide inertia and damping through VSM control. Meanwhile, energy storage presents some physical constraints in the VSM implementation level. In this paper, a VSM mathematical model is built and analyzed. The dynamic responses of the output active power are presented when a step change in the frequency occurs. The influences of the inertia constant, damping factor and operating point on the ESS volume margins are investigated. In addition, physical constraints are proposed based on these analyses. The proposed physical constraints are simulated using PSCAD/EMTDC software and tested through RTDS experiment. Both simulation and RTDS test results verify the analysis.

Operation Planning of Reserve in Microgrid Considering Market Participation and Energy Storage System

  • Lee, Si Young;Jin, Young Gyu;Kim, Sun Kyo;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1089-1095
    • /
    • 2014
  • Innumerable microgrids would be operated independently by individual operators in a future smart grid. This kind of decentralized power system requires entirely different operation scheme in the actual power system and electricity market operation. Especially, frequency regulation is very important for successive energy trade in this multi-microgrid circumstance. This paper presents an optimal energy and reserve market participation strategy and operation strategy of energy storage system (ESS) by a microgrid operator (MGO). For definite evaluation of the proposed strategy, we postulate that the MGO should participate in the Power Exchange for Frequency Control (PXFC) market, which was devised by Maria Ilic and her coworkers and is suitable to the decentralized operation circumstances. In particular, optimal reserve capacity of the frequency control market and optimal market participation ratio of ESS between frequency control market and energy market are derived theoretically and evaluated by simulations utilizing Nordic Pool Elspot price data.

ESS의 전자 잡음 주파수 분석 및 제거 (Frequency Analysis and Reduction of Electronic Noise in ESS)

  • 안봉만;한병성;한운기;이영관;안현진
    • 한국전기전자재료학회논문지
    • /
    • 제35권6호
    • /
    • pp.568-575
    • /
    • 2022
  • This paper is a study on frequency analysis and electronic noise reduction of energy storage system (ESS). We acquired 4 necessary data for about 2 minutes and 4 seconds using a sampling frequency of 10,000 Hz in ESS. Fast Fourier transform (FFT) was used for electronic noise analysis from the acquired data. As a result, it was confirmed that DC component, fundamental wave, second and higher harmonic component exist. For the attenuation of harmonics, low-pass filter (LPF) was applied. We confirmed that an attenuation of approximately 59.3% appears from the second harmonic. The presence of many harmonic components in the data of the ESS was expected to occur due to the insufficiency of optimization among the modules inside the ESS. Therefore, we propose that a national certification system for ESS should be introduced to settle down the issue properly.

Two Stage Hybrid Optimization을 사용한 ESS 최적 운전 전략에 대한 연구 (A Study on ESS Optimal Operation Strategy Using Two Stage Hybrid Optimization)

  • 공은경;손진만
    • 전기학회논문지
    • /
    • 제67권7호
    • /
    • pp.833-839
    • /
    • 2018
  • This paper presents an analysis and the methodology of optimal operation strategy of the ESS(Energy Storage System) for reduce electricity charges. Electricity charges consist of a basic charge based on the contract capacity and energy charge according to the power usage. In order to use electrical energy at minimal charge, these two factors are required to be reduced at the same time. QP(Quadratic Programming) is appropriate for minimization of the basic charge and LP(Linear Programmin) is adequate to minimize the energy charge. However, the integer variable have to be introduced for modelling of different charge and discharge efficiency of ESS PCS(Power Conversion System), where MILP(Mixed Integer Linear Programming) can be used. In this case, the extent to which the peak load savings is accomplished should be assumed before the energy charge is minimized. So, to minimize the electricity charge exactly, optimization is sequentially performed in this paper, so-called the Two Stage Hybird optimization, where the extent to which the peak load savings is firstly accomplished through optimization of basic charge and then the optimization of energy charge is performed with different charge and discharge efficiency of ESS PCS. Finally, the proposed method is analyzed quantitatively with other optimization methods.

발전기 가속에너지를 이용한 고장파급방지장치 운전조건 완화용 전기저장장치 적정용량 산정방안 (Required Capacity Assessment of Energy Storage System for Relieving Operation Condition of SPS Using Generator Acceleration Energy)

  • 송승헌;최우영;권한나;국경수
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Due to the highly concentrated power plants integrated through the limited transmission lines in Korea, a Special Protection System(SPS) has been applied to stabilize the power systems by instantly tripping the pre-determined generators in a large-scaled power plant when a fault occurs on the drawing transmission lines. Moreover, power outputs of those generators are constrained to avoid any activation of Under Frequency Load Shedding(UFLS) even after those generators are tripped by SPS action. For this, this paper proposes a method for calculating the required capacity of Energy Storage System(ESS) expected to relieve the operating constraints to generators using its fast response for controlling power system frequency. The proposed method uses the generator acceleration energy to derive the stable condition during the SPS action. In addition, its effectiveness is verified by the case studies adopting actual SPS operations in Korean power systems.

DC전원공급 기능을 보유한 600W PV ESS (600W PV ESS with DC power supply function)

  • 팽성일;박운호;임용배;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.85-86
    • /
    • 2017
  • 본 논문에서는 DC 48V 전원 공급이 가능한 600W급 PV ESS( Energy Storage system)시스템에 대하여 제안한다. PV 입력부는 100V이하의 전압 입력에서 사용할 수 있도록 3레벨 부스트(Three level boost)컨버터로 구성하였다. 배터리는 양방향 DC/DC 컨버터를 사용하였고 DC48V부는 벅 컨버터로 구성하였다. 제안한 시스템의 검증하기 위하여 시뮬레이션과 600W PV ESS 시스템을 구성 실험을 진행하였다.

  • PDF

주파수조정용 ESS의 성능검증 및 경제성평가 알고리즘에 관한 연구 (A Study on The Performance Verification and Economic Evaluation of ESS for Frequency Regulation Application)

  • 이주광;최성식;강민관;노대석
    • 한국산학기술학회논문지
    • /
    • 제18권5호
    • /
    • pp.738-744
    • /
    • 2017
  • 최근 신재생에너지의 확대 보급과 더불어 전기저장장치(ESS, Energy Storage System)가 활발하게 도입되고 있다. 하지만 현재 전기저장장치에 대한 도입효과와 경제성 및 계통에 미치는 영향에 대한 구체적인 평가방법이 없어 효과적인 도입운용이 어려운 실정이다. 특히 주파수조정용 ESS에 대한 국제적인 기술표준 및 제도가 마련되지 않아, 이의 설치에 따른 전기품질, 계통영향, 기여도 등은 물론 편익 산정에 대한 종합적인 연구가 필요한 실정이다. 따라서 본 논문에서는 주파수조정용 ESS의 성능검증 방안을 마련하기 위하여, 기존발전기의 주파수조정 성능평가 방법인 미국 PJM의 AGC(Automatic Generation Control, 발전기 자동발전제어) 성능 평가방식을 분석하여, 주파수조정용 ESS의 성능평가 알고리즘을 제안하였고, 고가발전기의 정산금과 화력발전기의 정산금을 이용하여 500MW급의 주파수조정용 ESS의 도입에 따른 편익을 산정할 수 있는 경제성 평가 알고리즘을 제시하였다. 제안한 알고리즘의 유용성을 확인하기 위하여, 실 계통 데이터를 바탕으로 시뮬레이션을 수행한 결과, 전기저장장치가 기존의 발전기에 비하여 아주 우수한 성능을 가지고 있음을 확인하였고, 500MW 도입시 연간 약 3,457~4,296억의 편익이 발생함을 확인하였다.

주택용 단상 ESS-PCS의 전압손실과 직류링크 맥동을 고려한 직류측 배터리 사이즈 및 제어기 설계 (Design of DC Battery Size & Controller for Household Single-Phase ESS-PCS Considering Voltage Drop and DC Link Voltage Ripple)

  • 김용중;이진성;김효성
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.94-100
    • /
    • 2018
  • Generally, in a single-phase energy storage system (ESS) for households, AC ripple component with twice the fundamental frequency exists inevitably in the DC link voltage of single-phase PCS. In the grid-connected mode of a single-phase inverter, the AC ripple component in the DC link voltage causes low-order harmonics on grid-side current that deteriorates power quality on an AC grid. In this work, a control system adopting a feedforward controller is established to eliminate the AC ripple interference on the DC link side. Optimal battery nominal voltage design method is also proposed by considering the voltage loss and AC ripple voltage on DC link side in a single-phase ESS. Finally, the control system and battery nominal voltage design method are verified through simulations and experiments.