• Title/Summary/Keyword: EMTP (Electro-magnetic Transient Program)

Search Result 92, Processing Time 0.035 seconds

Surge Protection Method of the Underground Distribution System in Korea (국내 지중배전시스템의 서어지 보호방안)

  • Lee, Jae-Bong;Jung, Yeon-Ha;Park, Chul-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.84-88
    • /
    • 2008
  • This paper deals with the part of the surge protection method of the underground distribution system in Korea using arrestors by simulating with ATP-EMTP(Electro-Magnetic Transient Program) based on the "A Study on the Surge Propagation Property of Underground Distribution Cables by Field Tests" which was published in 2007. Although domestic underground distribution system is protected by arrester which installed at a riser pole, we need to additional protection method because lightning surge can be doubled and affect underground distribution facilities when it is injected into the mixed distribution line of overhead and underground through a riser pole. In this paper, it is proposed that scout method that arresters are attached to the sides of a riser pole is better than developing of a elbow arrester on a viewpoint of economics and maintenance, because of the situation of the domestic underground distribution system.

Development of a Reclosing Scheme for Reduction of Turbine Generator Shaft Torsional Torques: A Decision Method to Achieve Optimal Reactor Capacity

  • Oh, Yun-Sik;Seo, Hun-Chul;Yang, Jeong-Jae;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1145-1153
    • /
    • 2014
  • It is well known that line switching operations like reclosing are able to cause transient power oscillations which can stress or damage turbine generators. This paper presents a reclosing scheme to reduce the shaft torsional torques of turbine generators by inserting an additional reactor. A novel method to determine optimal reactor capacity to minimize the torsional torque generated in a turbine generator is also proposed. In this paper, the turbine generator shaft is represented by a multi-mass model to measure torsional torques generated in the shaft between the turbine and the generator. Transmission systems based on actual data from Korea are modeled to verify the proposed scheme using ElectroMagnetic Transient Program (EMTP) software. The simulation results clearly show the effectiveness of the proposed scheme and torsional torque can be minimized by applying the proposed scheme.

A Harmonic Effect Analysis on Telecommunication Line Adjacent to 22.9kV Distribution Lines (22.9kV 배전선로에서의 고조파에 의한 인접 통신선 영향 분석)

  • Kim, Hyoun-Su;Rhee, Sang-Bong;Kim, Chul-Hwan;Lyu, Seung-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.151-153
    • /
    • 2007
  • Harmonic Currents flowing on the distribution system or within an end-user facility can induce the harmful voltage to telecommunication lines. In this paper, the induced voltages on telecommunication lines in distribution systems from harmonic component are simulated and analyzed with EMTP (Electro-Magnetic Transient Program).

  • PDF

Analysis of Progression of Transmission Line Fault by Fault Recorder Oscillograph (Fault Recorder 파형 분석을 통한 송전선로 고장 진전상황 분석)

  • Shim, Eung-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.525-526
    • /
    • 2011
  • 전력계통에서 발생하는 고장 중에는 고장 후의 결과만을 가지고는 어떻게 고장이 초기에 발생하여 진전되었는지를 추정하기가 어려운 고장이 간혹 발생한다. 본 고장 분석사례는 보호계전기의 동작사항과 고장기록장치의 파형을 이용하여 송전선로에서 고저항 지락에 의한 최초의 고장이 발생 할 수 있는 가능성과, 그 고장으로 인한 파급 고장 사례를 예시하였다. 과도현상 분석 프로그램인 EMTP (Electro-Magnetic Transient Program)를 이용하여 고장 사례를 재현하여 Fault Recorder 기록과의 유사성을 확인하였다.

  • PDF

Impact Analysis of a Grid-connected Photovoltaic system on High Impedance Fault (고저항 지락사고에 대한 태양광 발전의 영향분석)

  • Kim, Sang-Hyub;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.476_477
    • /
    • 2009
  • This paper compares the several cases with High Impedance Fault(HIF) conditions and analyzes the impact of the grid-connected photovoltaic system at the HIF conditions. Simulations are conducted by using Electro-Magnetic Transient Program (EMTP) and using the results, the analysis is presented.

  • PDF

Approximated Analysis method of Industrial Distribution System (산업용 수변전 계통의 근사화 해석 기법)

  • 이배희;설용태
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.172-174
    • /
    • 1999
  • In this paper the approximated analysis method of industrial distribution system using PTW(Power Tools for Windows). System input data, cable impedance and transformer data etc., were calculated by the approximated method using EMTP(Electro Magnetic Transient Program). The effectiveness of this method was improved by electrical characteristics analysis of real factory.

  • PDF

Effects of an Overhead Ground Wire and Surge Arrester in the Railway due to Lightning Strokes (전차선로에서의 뇌격에 의한 가공지선과 보안기의 차폐효과)

  • 임성정;김재철;창상훈;정용철
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.93-99
    • /
    • 2000
  • Using the EMTP(Electro Magnetic Transient Program) for the analysis of lightning direct voltage on the railway system, the shielding effects of overhead grounding wire on the railway were studied quantitatively. Installation of overhead ground wire and gap-type arrester such as s-horn Provides a 6.6㎸ HV distribution line with good protection effects. Even severe lightning induced voltage were create, 6.6㎸ HV lines can be withstand.

  • PDF

AC/DC Converter Modeling for EV Charging System using EMTP (EMTP를 이용한 전기자동차 충전기용 AC/DC 컨버터 모델링)

  • Jung, Dong-Su;Sim, Hyeong-Wook;Ju, Seong-Chul;Lee, Jae-Won;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.89-90
    • /
    • 2011
  • 최근 친환경적인 자동차 산업을 위해 지속적인 전기 자동차의 보급이 이루어지고 있다. 따라서 내연기관의 대체 교통수단으로 자리매김하기 위해 전기 자동차 충전소와 같은 적합한 인프라 구축이 필요하다. 전기 자동차 보급에 있어 가장 이슈가 되고 있는 부분은 전기 자동차의 충전시간이며 이 충전시간은 내연기관 차량의 주유 시간과 비교했을 때 비교적 길기 때문에 이를 최대한 단축시키기 위한 급속 충전 기술 개발이 시급하다. 본 논문에서는 전기 자동차용 급속 충전기에 대한 분석을 위해 EMTP(Electro Magnetic Transient Program)를 이용하여 3상 AC/DC 컨버터를 모델링하고 검증하였다.

  • PDF

Hybrid Type Superconducting Fault Current Limiter Modeling using EMTP (EMTP를 이용한 Hybrid Type Superconducting Fault Current Limiter)

  • Park, Se-Ho;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.172-174
    • /
    • 2008
  • A fault current limitation using fault current limiter(FCL) is very important for power system operation. In recent year, a number of research have been performed and still Progressing about the super conducting fault current limiter(SFCL), To protect the power system effectively from the large fault current, several superconducting fault current limiters proposed. However, there are many problem such as cost, recovery and ac loss. To solve these problems, hybrid superconducting fault current limiter(HSFCL) have been proposed. In this paper, HSFCL are modeled using (Electro Magnetic Transient Program - Restructured Version) EMTP-RV.

  • PDF

Modelling and Performance Analysis of UPFC Using EMTP/ATPDraw (EMTP/ATPDraw를 이용한 UPFC구현 및 동작 분석)

  • Jang, Won-Hyeok;Lee, You-Jin;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.217-219
    • /
    • 2008
  • Among the Flexible AC Transmission Systems (FACTS) devices, Unified Power Flow Controller (UPFC) is considered as the most powerful and versatile one as it provides simultaneous, real time control of the transmission parameters, voltages, impedances, and phase angles which determine the power flow in AC transmission systems. This paper presents modelling of UPFC and describes its characteristics. The UPFC implemented in this paper is based on Sinusoidal Pulse Width Modulation (SPWM) and Electro-Magnetic Transients Program (EMTP)/ATPDraw is used to model and analyze it. The simulation results confirm advantages of UPFC in operational performance with respect to the steady state Power flow regulation and the transient stability control.

  • PDF