• Title/Summary/Keyword: EMTDC/PSCAD

Search Result 690, Processing Time 0.028 seconds

A Study on an Evaluation Modeling of Power System Performance for Frequency Regulation ESS Based on the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 주파수조정용 ESS의 계통영향성 평가 모델링에 관한 연구)

  • Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Nam, Yang-Hyun;Park, Ji-Hyun;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1024-1030
    • /
    • 2018
  • Recently, the large scaled energy storage system(ESS) which has various functions such as peak saving, demand management, output stabilization of renewable energy and frequency regulation(FR) is being energetically installed and operated. Especially, as the use case of frequency regulation ESS, the KEPCO has demonstrated the total of 376[MW] ESS since 2014. However, there are no operational experiences and international technical standards on frequency regulation application in ESS. Therefore, this paper propose the evaluation algorithm for power system performance of ESS by considering the frequency characteristics between governor of existing generator and frequency regulation ESS, in order to verify the power system performance of ESS. And also, this paper propose an evaluation modeling for small scaled power system including the existing generator, frequency control ESS and customer loads based on the PSCAD/EMTDC S/W. From the simulation results in 360[MW] model power system, it is confirmed that frequency regulation ESS has better performances than conventional generators.

Jeju 80kV HVDC Controller Modeling Using PSCAD/EMTDC Program (PSCAD/EMTDC 프로그램을 이용한 제주 80kV HVDC 제어기 모델링)

  • Choi, Soon-Ho;Lee, Seong-Doo;Kim, Chan-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.533-541
    • /
    • 2011
  • This paper studies modeling of Jeju 80kV HVDC system and its controller by using PSCAD/EMTDC program. Reduced ac network is applied to verify interaction between ac network and dc system. Design parameter is applied to the converter transformer, harmonic filter and dc transmisstion line to simulate dc system. HVDC controller is divided into a rectifier controller and a inverter controller according to the converter operating mode. The inverter controller is composed of current control, voltage control and extingtion angle control. The rectifier controller is composed of current control and voltage control. Both controller has VDCOL characteristics so that current order is dependant on voltage variation. Step response, ac network single phase fault, three phase fault is simulated to verify the dynamic performance of controller model in both transient state and steady state.

A Study on the Modeling Method of Performance Evaluation System for MW Scaled Energy Storage System Using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 MW급 ESS용 성능평가설비 모델링 방안에 관한 연구)

  • Kang, Min-Kwan;Choi, Sung-Sik;Park, Jae-Beom;Nam, Yang-Hyeon;Kim, Eung-Sang;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.885-891
    • /
    • 2017
  • The energy storage system(ESS) is a core component for exchanging the power system structure of the unidirectional power flow into a bidirectional structure. Its important role has been increasing because it has multiple functions such as output stabilization of new renewable energy, demand management, frequency regulation, etc. However, the performance evaluation technology of ESS in korea is lower than one of advanced countries and the recognition of standardization is also lack compared to advanced countries. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W devices but also performance verification by S/W tool. Therefore, in order to verify the performance testing of ESS by S/W tool, this paper proposes the modeling method of performance testing devices for MW scaled ESS by using the PSCAD/EMTDC S/W, based on real testing devices in domestic institute. From the simulation results of proposed modeling method, it is confirmed that the proposed modeling method is a useful tool for performance validation of ESS.

Development of PSCAD User-defined Model for the Simulation of a PV Array (PV 어레이의 계통연계 모의를 위한 PSCAD 사용자 정의 모델 개발)

  • Ahn, Seon-Ju;Choi, Joon-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.134-139
    • /
    • 2011
  • Since large and small scale photovoltaic(PV) systems have been commercialized in many countries, it is necessary to assess the effects of PV systems on the electric power system. For this, the development of accurate simulation model of PV arrays is very important. PSCAD/EMTDC, a widely used simulation tool for analyzing the transient behavior of electrical apparatus and networks, does not have a standard model of a PV array. Therefore in order to simulate the PV array, users have to develop their own simulation model. However, the block-diagram-based model is very complicated, and it is hard to modify the model parameters. In this study, we develop the user-defined model of a PV array by using the Design Editor, which is provided by PSCAD program. The mathematical model of a PV array and the method to determine the parameters of nonlinear I-V equation are implemented in a Fortran code. The graphical user interface provides the users with easy and simple way to modify the PV array parameters and simulation conditions. In order to help the users, this model also provides the parameters of 10 commercial PV arrays.

A Study on the Compensation Control of Distribution Static Compensator Considering Induction Motor Load Using PSCAD/EMTDC (PACAD/EMTDC을 이용한 유도기 부하를 고려한 DSTATCOM의 보상제어에 관한 연구)

  • Lee, Myung-Un;Cho, Myung-Hyun
    • 전자공학회논문지 IE
    • /
    • v.43 no.1
    • /
    • pp.32-38
    • /
    • 2006
  • When induction motor moves, power quality decline of line is risen seriously because provoking voltage drop the moment to system power supply by excessive moving current as well as power-factor drop in case drive by light-load because current reaches in 6 times $\sim$ 8 times of rated current. In this paper, a modeling did an distribution system 13 bus type model and induction machine load presents in IEEE using a PSCAD/EMTDE package, and it displayed an accident conspiracy and a compensating factor of DSTATCOM through simulation show.

Modeling for Utility Interactive Photovoltaic Power Generation System using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 태양광 발전시스템의 배전계통 연계운전을 위한 모델링)

  • Kim, Woo-Hyun;Kang, Min-Kyu;Kim, Eung-Sang;Kim, Ji-Won;Ro, Byong-Kwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1180-1182
    • /
    • 1999
  • Modeling for utility interactive photovoltaic power generation system has been studied using PSCAD/EMTDC. The proposed model system consists of a simple utility circuit configuration, 3kW of single phase utility interactive photovoltaic system, single phase PWM voltage source inverter module, and feed forward PID controller as control circuit. In the system, the DC current is assumed constant, and the voltage source inverter provides sinusoidal ac current for the loads of utility system. The simulation results are given in order to verify the effectiveness of the proposed model. The phases of output voltage of utility system and the output current of the inverter module are compared. Especially, the compensation effect of the photovoltaic system for the unbalanced load is analyzed. and the transient phenomena for a phase to ground fault are also simulated.

  • PDF

Fixed speed wind power generation system modeling and transient state stabilization method using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 고정속 풍력발전시스템 모델링 및 과도상태 안정화기법)

  • Kim, Young-Ju;Park, Dae-Jin;Ali, Mohd Hasan;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1178-1179
    • /
    • 2008
  • This paper describes a modeling of fixed speed wind power generation system which comprise of wind turbine, generator and grid. The wind turbine is based on MOD-2, which is IEEE standard wind turbine, and includes a component using wind turbine characteristic equation. Fixed speed induction generator is directly connected to grid, so the variation of wind speed has effects on the electrical torque and electrical output power. Therefore the power control mode pitch control system is necessary for aerodynamic control of the blades. But the power control mode does not operate at the fault condition. So it is required some methods to control the rotor speed at transient state for stabilization of wind power system. In this paper, simulation model of a fixed speed wind power generation system based on the PSCAD/EMTDC is presented and implemented under the real weather conditions. Also, a new pitch control system is proposed to stabilize the wind power system at the fault condition. The validity of the stabilization method is demonstrated with the results produced through sets of simulation.

  • PDF

Modeling and Analysis of Seongsan Wind Farm using PSCAD/EMTDC Program (PSCAD/EMTDC에 의한 성산풍력발전단지의 모델링과 해석)

  • Kim, Jae-Hong;Kang, Bo-Seung;Kim, Eel-Hwan;Kim, Se-Ho;Oh, Sung-Bo;Song, Ki-Heuk;Kim, Young-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1180-1181
    • /
    • 2008
  • 불확실한 출력 변화 특성을 갖는 풍력발전 설비가 제주지역에 크게 증가하고 있다. 이러한 증가는 풍력발전 설비가 연계된 선로에 전력의 품질을 떨어뜨릴 수 있는 가능성이 커진다. 성산 풍력발전단지는 2008년도 현재 기준으로 총 67[MW]의 풍력발전 용량이 180[KVA]의 설비용량을 갖는 성산변전소 22.9[kV] 배전선로에 접속된다. 이로 인하여 풍력발전의 출력변화에 따른 성산변전소의 배전선로에 나타나는 전력품질의 변화를 사전에 예측하고 검토할 필요가 있다. 이에 본 논문에서는 전력전자와 전력계통의 여러 가지 모델을 쉽게 해석 할 수 있는 PSCAD/EMTDC 프로그램을 이용하여 제주지역의 전 계통을 모델링하고 제주계통 부하용량이 320[MW] 기저 부하시 급격한 풍력발전 출력변화에 따른 성산변전소의 배전선로에 나타나는 전압과 주파수 변화에 대한 전력품질 특성을 시뮬레이션 결과를 통하여 나타내고자 한다.

  • PDF

Development of PSCAD/EMTDC Inverter Module for Simulating Grid-connect Wind Energy Conversion System (풍력발전 계통연계 모의를 위한 PSCAD/EMTDC 인버터 모듈 개발)

  • Kim, Seul-Ki;Kim, Eung-Sang;Park, Min-Won;Kim, Ji-Won;Jeon, Jin-Hong;Kim, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.204-206
    • /
    • 2002
  • 계통연계 풍력발전시스템의 특성을 고찰하기 위해서는 블레이드, wind turbine, 정류기, 인버터 등의 풍력발전시스템의 각 구성요소의 모델링과 적절한 제어 알고리즘에 대한 모의가 요구된다. 본 연구에서는 동기발전기를 풍력발전기로 사용하고 있는 계통연계형 풍력발전시스템의 출력 및 동특성을 모의하기 위한 전류제어형 전압원인버터의 PSCAD/EMTDC 모듈을 제시한다. 풍속의 가변특성에 의해 동기발전기에 들어오는 입력은 변하게 되고, 동기발전기가 동기주파수를 유지할 수 있도록 인버터에서는 이러한 입력과 동일한 출력을 낼 수 있어야 하며, 동시에 계통에서 허용하는 일정 전압과 계통주파수와 동일한 주파수를 갖는 출력을 공급해야 한다. 본 논문에서는 이를 위해 동기발전기의 주파수를 제어하는 전류제어형 전압원인버터 모듈을 소개한다. 모의를 통해 결과를 검증한다.

  • PDF

Modeling for Power Supply Substation in Maglev Train System (자기부상열차 급전변전소의 모델링)

  • Lee, Yun-Seong;Kim, Jin-O;Kim, Hyung-Chul;Kim, Ju-Rak;Lee, Jun-Kyung
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.3
    • /
    • pp.278-282
    • /
    • 2010
  • Since a power supply substation of the magnetic levitation train system includes a inverter which is necessary to change the frequency of power, it has a different characteristic comparing to any other railway system. Nowaday a study for determining rating of facilities constituting a power supply system and modeling that system is undergoing. In this paper, a analysis model for the power supply system of the magnetic levitation train using the 3-level inverter is proposed. And the analysis for output characteristic is performed using the PSCAD/EMTDC program. The control method about the output of 3-level inverter for supplying power to loads in magnetic levitation train system is also described.