• 제목/요약/키워드: EMG sensor

검색결과 90건 처리시간 0.024초

재활환자 모의보행 패턴분석을 이용한 하지 편측 장애자의 정량적 재활상태 모니터링 (Quantitative Rehabilitation Extent Monitoring for Unilateral Lower Extremity Disabled Patients using Simulated Gait Pattern Analysis)

  • 문동준;김주영;노시철;최흥호
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권6호
    • /
    • pp.227-233
    • /
    • 2014
  • In this paper, to quantitatively evaluate the degree of rehabilitation for the disabled of unilateral lower extremity, we compared the EMG pattern of normal and simulated abnormal gait. The EMG signal was measured at a rate of 1 kHz on the quadriceps and biceps femoris, the pressure sensor was attached to the sole in order to distinguish the gait cycle. Integrated EMG (IEMG) was obtained by the gait cycle, and classified four patterns that were the normal gait pattern, amplitude decrease pattern, reversed pattern, and irregular pattern. For comparison of the patterns, a curve fitting was performed using the trigonometric functions. The result of curve fitting, the method using a variable A that corresponds to the amplitude of the regression curve was able to distinguish the reverse pattern and remaining pattern. The coefficient of determination ($R^2$) representing coincidence of the pattern of the regression curve and EMG was confirmed the biggest value at the normal gait. Therefore, the degree of normal gait can be confirmed using the coefficient of determination. This results show that it is possible to quantitatively confirm the degree of unilateral lower extremity disabled rehabilitation, and it will be contributed to the study of efficient rehabilitation methods by objective analysis.

등척성 무릎 토크 발생 시 사전활성화 유형의 차이가 최대 자발적 토크 생성에 미치는 영향 (Effect of Muscle Pre-activation Properties on the Magnitude of Joint Torque during Voluntary Isometric Knee Extension)

  • Kim, Jong-Ah;Shin, Narae;Lee, Sungjune;Xu, Dayuan;Park, Jaebum
    • 한국운동역학회지
    • /
    • 제31권2호
    • /
    • pp.140-147
    • /
    • 2021
  • Objective: The purpose of this study is to identify the mechanism of changes in maximum voluntary torque with the magnitude and duration of pre-activation torque during voluntary isometric knee extension. Method: 11 male subjects (age: 25.91±2.43 yrs., height: 173.12±3.51 cm, weight: 76.45±7.74 kg) participated in this study. The subjects were required to produce maximal voluntary isometric torque with a particular pre-activation torque condition. The properties of pre-activation torque consisted of the combinations of 1) three levels of magnitude, e.g., 32 Nm, 64 Nm, 96 Nm, and 2) two levels of duration, e.g., 1 sec, and 3 sec; thus, a total of six conditions were given to the subjects. The force and EMG data were measured using the force transducers and wireless EMG sensor, respectively. Results: The results showed that the maximum voluntary torque increased the most with relatively large and fast (96 Nm, 1 sec) pre-activation condition. Similarly, with relatively large and fast (96 Nm, 1 sec) preactivation, it was found that the integrated EMG (iEMG) of the agonist muscles increased, while no significant changes in the co-contraction of the antagonist muscles for the knee extension. Also, the effect of pre-activation conditions on the rate of torque development was not statistically significant. Conclusion: The current findings suggest that relatively larger in magnitude and shorter in duration as the properties of pre-activation lead to a larger magnitude of maximal voluntary torque, possibly due to the increased activity of the agonist muscles during knee extension.

근활성도(EMG) 측정 전극 레이어 설계에 따른 성능 및 안정성 평가 (Performance and Stability Evaluation of Muscle Activation (EMG) Measurement Electrodes According to Layer Design)

  • 구본학;이동희;김주용
    • 감성과학
    • /
    • 제26권4호
    • /
    • pp.41-50
    • /
    • 2023
  • 본 연구는 EMG(electromyography) 텍스타일 전극 개발을 목적으로 레이어 수의 디자인 및 원단을 다르게 하여 성능 및 신호 획득 안정성을 평가한다. 레이징 및 프레스 공정을 통하여 텍스타일 전극을 제조하며 Layer-0, Layer-1, Layer-2로 레이어 유무 및 수에 따른 결과를 분석했다. 이에 레이어 유무에 따라서는 근활성 측정에 영향을, 수가 많을수록 높은 성능이 나타남을 확인할 수 있었다. Layer-2 구조로 통일하여 5가지의 원단(네오프렌, 스판덱스 쿠션, 폴리에스테르 100%, 나일론 스판덱스, 광목 캔버스)으로 전극을 제조해 실험해 보았다. 성능적인 면에서, 원단의 중량이 높은 나일론 스판덱스가 높은 성능을 보였으며, 스판쿠션 텍스타일 전극이 근활성도 수득에 높은 안정성을 보였다. 이에 위 연구는 레이어에 따른 성능 연관성과 전극-피부사이의 닿는 면적 간의 관계 등을 고찰하여 슬리브 전체의 의복압을 늘리는 대신 특정 센서 측정 부위에만 높은 압력을 가함으로 차후 연구에서 레이어의 수 및 물성에 따른 전극의 공학적 설계 가능성을 제시한 의의가 있다.

IR센서 기반 보행보조기를 이용한 보행 시 경사상태에 따른 보행의지 파악에 관한 연구 (A Study on Walking Intention Detection of Gait Slope and Velocity of the Rollator Based on IR Sensor)

  • 이현종;강승록;유창호;권대규
    • 재활복지공학회논문지
    • /
    • 제8권4호
    • /
    • pp.259-265
    • /
    • 2014
  • 본 논문은 보행의지를 파악하기 위해 IR 센서 기반 보행보조기를 이용하여 보행 시 슬관절 전방변위 측정과 하지의 근육활성도를 고찰하였다. 슬관절 전방변위 측정을 위해 보행보조기에 IR센서를 장착하였고, 근전도 (Bagnoli-8ch, Delsys Inc, USA)장비를 이용하여 대퇴직근, 대퇴이두근, 전경골근, 비복근을 측정 하였다. 실험에 참가한 피험자들은 성인 8명(나이 $23.7{\pm}0.5years$, 신장 $175.4{\pm}2.3cm$, 체중 $70.6{\pm}5.6kg$)이며 매주 30분씩 총 3주간 진행되었다. 보행 시 경사조건과 보행 속도의 증가에 따라서 슬관절 전방변위가 변화되는 결과를 확인할 수 있었다. 또한 근육활성도 결과, 전방경사 시 대퇴부 근육의 활성도가 증가하였고 후방경사 시 하퇴부 근육이 많이 활성화 되어 IR센서 결과와 유사한 경향을 확인할 수 있었다.

  • PDF

노약자의 팔꿈치 거동 지원을 위한 착용형 로봇 개발 (Development of Wearable Robot for Elbow Motion Assistance of Elderly)

  • 장혜연;한창수;김태식;장재호;한정수
    • 한국정밀공학회지
    • /
    • 제25권3호
    • /
    • pp.141-146
    • /
    • 2008
  • The purpose of this study is to develop the algorithm which can control muscle power assist robot especially for elderly. Recently, wearable robots for power assistance are developed by many researchers, and its application fields are also variable such as for medical or military equipment. However, there are many technical barriers to develop the wearable robot. This study suggest a control method improving performance of a wearable robot system by using a EMG signal of major muscles and a force sensor signal as command signal of system. The result of the robot Prototype efficiency experiment, the case of Maximum Isometric motion it suggest 100% power of muscle, the man need only 66% of MVIC(Maximum Voluntary Isometric Contraction) to lift 5kg dumbbell without robot assist. However the man needs only 52% of MVIC to lift 5kg dumbbell with robot assist. Therefore 20% muscle power increased with robot assist. Also, we designed light weight robot mechanism that extract the command signal verified and drive the wanted motions.

Comparison of Muscle Activity of Vastus Lateralis and Medialis Oblique among Knee Extension Angles at 90°, 135°, 180° in Sitting Position

  • Jeon, InCheol
    • The Journal of Korean Physical Therapy
    • /
    • 제32권1호
    • /
    • pp.52-57
    • /
    • 2020
  • Purpose: This study compared the muscle activities of the Vastus medialis oblique (VMO) and the Vastus lateralis (VL) at three different knee extension angles: 90°, 135°, and 180° in the sitting position. Methods: Twenty subjects between 20 and 30 years of age participated in the study. A mobile phone application called the Clinometer was used to measure the knee joint angle. Electromyography (EMG) was performed to measure the muscle activities of the VMO and VL muscles during knee isometric extension exercises. The pulling sensor was used to maintain 70% of the maximum strength of the knee extensor continuously in the sitting position. After attaching the EMG sensor, the subjects were asked to perform isometric knee extension exercises randomly among three knee extension angles (90°, 135°, or 180°) in the sitting position. One-way repeated measures analysis of the variance and a Bonferroni post hoc test was used to identify the VMO and VL muscle activity during knee extension angles among 90°, 135°, and 180°. Results: The VMO and VL muscle activities increased with increasing knee extension angle in the sitting position (p<0.01). Conclusions: Knee extension exercise at a 180° angle in the sitting position can be recommended to increase the muscle activity of the VMO and VL muscle activities efficiently.

Development and physiological assessments of multimedia avian esophageal catheter system

  • Nakada, Kaoru;Hata, Jun-ichi
    • Journal of Multimedia Information System
    • /
    • 제5권2호
    • /
    • pp.121-130
    • /
    • 2018
  • We developed multimedia esophageal catheters for use with birds to measure and record ECG and angular velocity while anesthesized, at rest, and in flight. These catheters enable estimates of blood pressure based on readings given by an angular velocity sensor and by RR intervals of ECG affected by EMG. In our experiments, the catheters had the following characteristics: 1. Esophageal catheters offer a topological advantage with 8-dB SNR improvement due to elimination of electromyography (EMG). 2. We observed a very strong correlation between blood pressure and the angular velocity of esophageal catheter axial rotation. 3. The impulse conduction pathway (Purkinje fibers) of the cardiac ventricle has a direction opposite to that of the mammalian pathway. 4. Sympathetic nerves predominate in flight, and RR interval variations are strongly suppressed. The electrophysiological data obtained by this study provided especially the state of the avian autonomic nervous system activity, so we can suspect individual's health condition. If the change of the RR interval was small, we can perform an isolation or screening from the group that prevent the pandemics of avian influenza. This catheter shall be useful to analysis an avian autonomic system, to perform a screening, and to make a positive policy against the massive infected avian influenza.

HandButton: Gesture Recognition of Transceiver-free Object by Using Wireless Networks

  • Zhang, Dian;Zheng, Weiling
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권2호
    • /
    • pp.787-806
    • /
    • 2016
  • Traditional radio-based gesture recognition approaches usually require the target to carry a device (e.g., an EMG sensor or an accelerometer sensor). However, such requirement cannot be satisfied in many applications. For example, in smart home, users want to control the light on/off by some specific hand gesture, without finding and pressing the button especially in dark area. They will not carry any device in this scenario. To overcome this drawback, in this paper, we propose three algorithms able to recognize the target gesture (mainly the human hand gesture) without carrying any device, based on just Radio Signal Strength Indicator (RSSI). Our platform utilizes only 6 telosB sensor nodes with a very easy deployment. Experiment results show that the successful recognition radio can reach around 80% in our system.

Change in Pelvic Motion Caused by Visual Biofeedback Influences Trunk and Hip Muscle Activities During Side-Lying Hip Abduction in Asymptomatic Individuals

  • Yu, Ilyoung;Kang, Minhyeok
    • 국제물리치료학회지
    • /
    • 제10권3호
    • /
    • pp.1818-1822
    • /
    • 2019
  • Background: Ipsilateral pelvic elevation has been reported as a common compensatory movement during side-lying hip abduction. It has been reported that pelvic elevation inhibits sufficient contraction of gluteus medius. However, few studies have identified the effects of controlled pelvic elevation on the trunk and hip muscles. Objective: To examine the effects of controlled pelvic elevation using visual biofeedback on the muscle activity of the trunk and hip muscles. Design: Crossover study. Methods: Twelve healthy males performed side-lying hip abduction exercises with and without visual biofeedback for pelvic elevation. Electromyography (EMG) activities of the gluteus medius, quadratus lumborum, and multifidus were analyzed using a wireless EMG system while the ipsilateral pelvic elevation angle was measured using a motion sensor during side-lying hip abduction exercises. Results: EMG activities of the gluteus medius (p = .002), quadratus lumborum (p = .022), and multifidus (p = .020) were significantly increased and ipsilateral pelvic elevation was significantly decreased (p = .001) during side-lying hip abduction with visual biofeedback compared to without visual biofeedback. Conclusions: The results of this study suggest that the application of biofeedback for pelvic motion could improve the trunk and hip muscle activation pattern and decrease compensatory pelvic motion during side-lying hip abduction exercise.

Hand Gesture Recognition Suitable for Wearable Devices using Flexible Epidermal Tactile Sensor Array

  • Byun, Sung-Woo;Lee, Seok-Pil
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1732-1739
    • /
    • 2018
  • With the explosion of digital devices, interaction technologies between human and devices are required more than ever. Especially, hand gesture recognition is advantageous in that it can be easily used. It is divided into the two groups: the contact sensor and the non-contact sensor. Compared with non-contact gesture recognition, the advantage of contact gesture recognition is that it is able to classify gestures that disappear from the sensor's sight. Also, since there is direct contacted with the user, relatively accurate information can be acquired. Electromyography (EMG) and force-sensitive resistors (FSRs) are the typical methods used for contact gesture recognition based on muscle activities. The sensors, however, are generally too sensitive to environmental disturbances such as electrical noises, electromagnetic signals and so on. In this paper, we propose a novel contact gesture recognition method based on Flexible Epidermal Tactile Sensor Array (FETSA) that is used to measure electrical signals according to movements of the wrist. To recognize gestures using FETSA, we extracted feature sets, and the gestures were subsequently classified using the support vector machine. The performance of the proposed gesture recognition method is very promising in comparison with two previous non-contact and contact gesture recognition studies.