• Title/Summary/Keyword: EMC Test

Search Result 130, Processing Time 0.022 seconds

Synthesis and Electrochemical Characteristics of Mesoporous Silicon/Carbon/CNF Composite Anode (메조기공 Silicon/Carbon/CNF 음극소재 제조 및 전기화학적 특성)

  • Park, Ji Yong;Jung, Min Zy;Lee, Jong Dae
    • Applied Chemistry for Engineering
    • /
    • v.26 no.5
    • /
    • pp.543-548
    • /
    • 2015
  • Si/C/CNF composites as anode materials for lithium-ion batteries were examined to improve the capacity and cycle performance. Si/C/CNF composites were prepared by the fabrication process including the synthesis and magnesiothermic reduction of SBA-15 to obtain Si/MgO by ball milling and the carbonization of phenol resin with CNF and HCl etching. Prepared Si/C/CNF composites were then analysed by BET, XRD, FE-SEM and TGA. Among SBA-15 samples synthesized at reaction temperatures between 50 and $70^{\circ}C$, the SBA-15 at $60^{\circ}C$ showed the largest specific surface area. Also the electrochemical performances of Si/C/CNF composites as an anode electrode were investigated by constant current charge/discharge test, cyclic voltammetry and impedance tests in the electrolyte of LiPF6 dissolved in mixed organic solvents (EC : DMC : EMC = 1 : 1 : 1 vol%). The coin cell using Si/C/CNF composites (Si : CNF = 97 : 3 in weight) showed better capacity (1,947 mAh/g) than that of other composition coin cells. The capacity retention ratio decreased from 84% (Si : CNF = 97 : 3 in weight) to 77% (Si : CNF = 89 : 11 in weight). It was found that the Si/C/CNF composite electrode shows an improved cycling performance and electric conductivity.

Surface Checking Reduction Effect of Preservative-treated Korean Larch Round-woods with Various Physical Treatments (물리적 처리에 따른 낙엽송 방부원주목의 표면할렬 방지효과)

  • Pang, Sung-Jun;Oh, Jung-Kwon;Lee, Sang-Joon;Park, Jun-Ho;Jang, Sung-Il;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.107-115
    • /
    • 2017
  • In this study, the surface check reduction effect of preservative-treated Korean larch round-wood was investigated by applying three physical treatments, such as incising, kerfing, and kiln-drying. Moreover, the possibility of long-term service life was also checked by comparing the depth of surface check and the penetration depth of preservative. A rapid gradient of wood moisture content between surface and center causes a surface check. Thus, the effect of reducing surface check was carried out at the lowest equilibrium moisture content (EMC) condition, temperature ($2^{\circ}C$), humidity (44.6%), in outdoor locations in Korea until the test specimens reach to the 8.6% EMC. As a result, the preservative-treated specimens without incising, kerfing, kiln-drying (Type C) could not ensure the long-term service life due to a large surface check. Because the surface check depth of all specimens was deeper than the penetration depth of preservative. In case of the incising treated specimens (Type I), 80% of them, the depth of surface check was not deeper than the penetration depth of preservative. However, when a kerfing was additionally treated (Type B), a possibility of happening deeper surface check than penetration depth of preservative was increased rather than Type I.

Effect of Vinyl Ethylene Carbonate on Electrochemical Characteristics for Activated Carbon/Li4Ti5O12 Capacitors (활성탄/리튬티탄산화물 커패시터의 전기화학적 특성에 미치는 비닐에틸렌카보네이트의 영향)

  • Kwon, Yong-Kab;Choi, Ho-Suk;Lee, Joong-Kee
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.190-197
    • /
    • 2012
  • We employed the vinyl ethylene carbonate (VEC) as an electrolyte additive and investigated the effect of the electrolyte additive on the electrochemical performance in hybrid capacitor. The activated carbon was adopted as cathode material, and the $Li_4Ti_5O_{12}$ oxide was used as anode material. The electrolyte was prepared with the $LiPF_6$ salt in the mixed solvent of ethylene carbonate (EC), dimethyl carbonate (DMC), and ethyl methyl carbonate(EMC). We evaluated the electrochemical performance of the hybrid capacitor with increasing the amount of the VEC electrolyte additive, which is known as the remover of oxygen functional group and the stabilizer of the electrode by reducing the surface of electrode, and obtained the superior performance data especially at the addition of the VEC electrolyte additive of around 0.7 vol%. On the contrary, the addition of the VEC more than 0.7 vol% in the electrolyte leads to the degradation in electrochemical performance of hybrid capacitor, suggesting the increase of the side reaction from the excessive VEC additive. X-ray photoelectron spectroscopy (XPS) revealed that the addition of the VEC suppressed the formation of LiF component, which is known as the insulator, on the surface of electrode. The optimized addition of VEC exhibited the improved capacity retention around 82.7% whereas the bare capacitors without VEC additive showed the 43.2% of capacity retention after 2500 cycling test.

Drying Characteristics and Drying Model of Red Pepper (고추의 건조특성(乾燥特性)과 건조모델에 관(關)한 연구(硏究))

  • Cho, Y.J.;Koh, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.11 no.1
    • /
    • pp.52-63
    • /
    • 1986
  • This study was performed to find out drying characteristics and develop drying model for the design of an efficient dryer or drying system of red peper. The basic model which describes drying phenomenon of red pepper was firstly established, and drying tests were conducted at 14-different drying conditions. In this test, the effects of drying air temperature and relative humidity on the rate of drying were undertaken. Finally, a new drying model based on these experimental results was developed to describe the drying characteristics of red pepper. The results from this study may be summarized as follows. 1. Drying constant of the basic model established from Lewis' experimental model and diffusion equation was theoretically deduced as a function of moisture content and inner-temperature of red pepper. 2. From the results of drying tests, drying air temperature was found to have the greatest effect on the rate of drying. However, the effect of temperature was small for the condition of high relative humidity, and for low temperature, the effect of relative humidity was found to be large even though the range of relative humidity was low. 3. Modified Henderson equation was found to be better than Chung equation as the EMC model for the estimation of the equilibrium moisture content of red Pepper. 4. Constant-rate drying period did not exist in the red pepper drying test. And falling-rate drying period was divided into three distinct phases. Drying rate was dependent on the moisture content, the inner-temperature of red pepper and the change of physical property due to drying. 5. Drying constant increased with decrease of free moisture content, but it decreased at the end of the drying period. Also, drying constant was dependent on the drying air temperature and relative humidity. 6. The new drying model developed in this study was found to be most suitable in describing the drying characteristics of red pepper. Therefore, it may be concluded that drying time could be accurately estimated by the new drying model.

  • PDF

A Study on the Effects of I&C Systems by EMI Generating from Corona Discharge at Transformer Area (변압기 지역 코로나 전자파 간섭에 의한 계측제어설비 영향에 관한 연구)

  • Min, Moon-Gi;Lee, Jae-Ki;Park, Jin-Yeub;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.266-271
    • /
    • 2014
  • The Electromagnetic Interference(EMI) generating from corona discharge of transformer area can interference the digital Instrument and Control(I&C) systems located nearby transformers. When the potential gradient of the electric field around the conductor is high enough to form a conductive region but not high enough to cause electrical breakdown to nearby objects, the EMI of corona discharge emits with the conducted and radiated noise and it interferences the signals of the I&C systems. Since digital I&C systems have an efficiency and competitive price, the analog I&C systems have been upgraded and displaced with the digital I&C systems but which have less EMI Immunity. There was no assessment to I&C systems by EMI generating corona discharge nearby transformers. When the safety-related I&C systems are installed in plants, the verification of equipment EMI should be done not in site-specific test but in test facilities. There are the need to do the site-specific EMI evaluation of corona discharge nearby transformers. This paper assesses the margin between plant emission limits and the highest composite plant emission of corona. When the non safety-related I&C systems are placed in transformer area, it suggests the appropriate radiated susceptibility level to EMI of corona discharge.

Grid Based Nonpoint Source Pollution Load Modelling

  • Niaraki, Abolghasem Sadeghi;Park, Jae-Min;Kim, Kye-Hyun;Lee, Chul-Yong
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.246-251
    • /
    • 2007
  • The purpose of this study is to develop a grid based model for calculating the critical nonpoint source (NPS) pollution load (BOD, TN, TP) in Nak-dong area in South Korea. In the last two decades, NPS pollution has become a topic for research that resulted in the development of numerous modeling techniques. Watershed researchers need to be able to emphasis on the characterization of water quality, including NPS pollution loads estimates. Geographic Information System (GIS) has been designed for the assessment of NPS pollution in a watershed. It uses different data such as DEM, precipitation, stream network, discharge, and land use data sets and utilizes a grid representation of a watershed for the approximation of average annual pollution loads and concentrations. The difficulty in traditional NPS modeling is the problem of identifying sources and quantifying the loads. This research is intended to investigate the correlation of NPS pollution concentrations with land uses in a watershed by calculating Expected Mean Concentrations (EMC). This work was accomplished using a grid based modelling technique that encompasses three stages. The first step includes estimating runoff grid by means of the precipitation grid and runoff coefficient. The second step is deriving the gird based model for calculating NPS pollution loads. The last step is validating the gird based model with traditional pollution loads calculation by applying statistical t-test method. The results on real data, illustrate the merits of the grid based modelling approach. Therefore, this model investigates a method of estimating and simulating point loads along with the spatially distributed NPS pollution loads. The pollutant concentration from local runoff is supposed to be directly related to land use in the region and is not considered to vary from event to event or within areas of similar land uses. By consideration of this point, it is anticipated that a single mean estimated pollutant concentration is assigned to all land uses rather than taking into account unique concentrations for different soil types, crops, and so on.

  • PDF

Design and Development of Signal Transmitting POD for Aircraft Application (항공기용 신호 송출 POD의 설계 및 개발)

  • Kim, Jee-heung;Kwak, Young-kil;Kim, Kichul;Park, Joo-rae
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • In this research, we develop an airborne equipment radiating S/C-band signal to a target located at a long distance. RF interface of the equipment comprises band-specific transmitters and an broadband antenna to satisfy EIRP(effective isotropic radiated power) requirements. The equipment is in a shape of a POD like an aircraft fuel tank. The measured weight of the equipment is 119.8 kg, the CG(center of gravity) is 1391.35 mm and the MOI(moment of inertia) are 46.07 ± 0.05(Iyy) kg·㎡, 45.36 ± 0.09(Izz) kg·㎡. All results are found to meet the requirements for aircraft installation. To verify flight safety, EMI(electromagnetic interference) tests (RE102, CE102), environmental tests (high/low temperature operation, altitude), intra-system EMC(electromagnetic compatibility) and HERP(hazards electromagnetic radiation personnel) tests have been conducted and all the test results met the requirements. It is confirmed that the equipment could be mounted on the aircraft by meeting all electrical and mechanical requirements.

An Investigation of EMI Reduction Technique using the Spread Spectrum for an Automotive Power Converter (EMI 개선을 위해 자동차용 전력변환기에 적용된 주파수 확산 기법 분석)

  • Chae, Gyoo-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.2
    • /
    • pp.1-6
    • /
    • 2018
  • In this study, the investigation results of conducted and radiated emission for DC/DC converter circuit applied in electric vehicles are presented. A frequency spreading circuit was used to improve the EMI characteristics of a power converter designed by using MPQ4433 chip. The frequency spreading circuit using a TLV3201 chip was designed and applied to the power converter. A PCB was fabricated based on the EMI minimization procedures and simulated and measured results were presented for the far-field and near-field conducted and radiated emissions using the fabricated circuit. The measurement were done as CISPR 25 standardized test procedures. It is clearly showed that the EMI characteristics were improved 20% in case frequency spreading was applied. The EMI reduction technique using the frequency spreading proposed in this study was first applied to the design of power converter module for automobile. It is expected that the method presented here can be effectively used for EMI improvement in the future.

Thymectomy in Patients with Myasthenia Gravis (흉선절제로 치료한 중증 근무력증)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.872-880
    • /
    • 1985
  • Myasthenia gravis is a neuromuscular transmission disorder characterized by fatigue and weakness of voluntary muscles. Although the pathogenesis is known as reduction of available acetylcholine receptors at neuromuscular junctions by autoimmune attack, the thymic role in myasthenia gravis is still unclear and under investigation. But thymectomy in the management of myasthenia gravis has become increasingly important since the first successful operation with remission of symptoms in 1939 by Blalock. From January 1983 to June 1985, authors performed 17 thymectomies for patients with myasthenia gravis. Among them, 12 patients were free from thymoma [Croup A] and 5 were coupled with thymoma [Group B]. The results were as follows: 1] Sex distribution was 11 females and 6 males. Mean age of the patients was 32.2 year old. Sex and age distribution by the Group A and B are shown Table 1. 2] Clinical manifestations of ocular symptoms were seen in 5 patients [88.2%], extremity weakness in 13 patients, bulbar weakness in 12 patients and dyspnea in 6 patients. According to the Osserman`s classification, 5 patients were in group IIA, 6 in IIB and 6 in IIC. 3] Pre-operatively, all patients were positive response to the anti-cholinesterase test and 12 patients [92.3%] revealed positive findings in electromyography [EMC] which was done in 13 patients. 4] The postoperative complications were respiratory distress in 3 patients, myasthenic crisis in 2 patients and wound disruption in one patients. 5] Pathologic examination of the thymus showed hyperplasia in 10 patients [90%] and thymoma in 5 patients, of which 4 were mixed type with invasion to the adjacent tissues and one lymphocytic type without invasion. Normal thymus was noticed in only 2 patients. 6] In postoperative evaluations, among the 12 patients c free from thymoma [Group A], complete remission of symptoms was noticed in 3 patients and improvement in 7 patients. But among the 5 patients coupled with thymoma [Group B], only one patients showed improvement [Table 8]. Therefore, remission and clinical improvement were noticed in 11 patients [64.7%] of the all and complete remission was noticed in 3 patients [17.6%].

  • PDF

Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply (레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석)

  • Ryu, Ji-Ho;Cho, Chong-Hyeon;Chong, Min-Kil;Park, Sung-Jin;Kang, Kwang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.60-71
    • /
    • 2019
  • Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.