• Title/Summary/Keyword: EM Field

Search Result 245, Processing Time 0.031 seconds

An online learning system for evaluating learner's activities and study level (수준별 학습과 학습 관심도를 고려한 학습평가시스템)

  • Kim, Hye-Em;Yu, Seok-Jong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.6
    • /
    • pp.69-76
    • /
    • 2008
  • The biggest strength of the Internet is to enable to access information without any limitation of time and space. As the Internet and IT technologies have been developed, various kinds of teaching ways in education field such as remote lectures, video lectures, and CAI(Computer Adapted Instruction) have emerged. In terms of education, evaluation can be a basic foundation to help teach students in the next learning stage according to each student's level. In addition, it is able to give the information of students'abilities and provides proper learning programs to teach students on a case-by-case basis. The purpose of the paper is to establish evaluation system on the WWW(World Wide Web) that can reflect learning activities part of students in their evaluation scores based on the two important learning theories, Behaviorism and constructivism, which are mainly used in evaluation procedures to judge learning ability of students. This system will give information about learners, and analyze the learning interest of learners. The proposed system enables teachers to evaluate learning ability of students through various kinds of information of learners, and to execute level-based education.

  • PDF

Precise System Models using Crystal Penetration Error Compensation for Iterative Image Reconstruction of Preclinical Quad-Head PET

  • Lee, Sooyoung;Bae, Seungbin;Lee, Hakjae;Kim, Kwangdon;Lee, Kisung;Kim, Kyeong-Min;Bae, Jaekeon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1764-1773
    • /
    • 2018
  • A-PET is a quad-head PET scanner developed for use in small-animal imaging. The dimensions of its volumetric field of view (FOV) are $46.1{\times}46.1{\times}46.1mm^3$ and the gap between the detector modules has been minimized in order to provide a highly sensitive system. However, such a small FOV together with the quad-head geometry causes image quality degradation. The main factor related to image degradation for the quad-head PET is the mispositioning of events caused by the penetration effect in the detector. In this paper, we propose a precise method for modelling the system at the high spatial resolution of the A-PET using a LOR (line of response) based ML-EM (maximum likelihood expectation maximization) that allows for penetration effects. The proposed system model provides the detection probability of every possible ray-path via crystal sampling methods. For the ray-path sampling, the sub-LORs are defined by connecting the sampling points of the crystal pair. We incorporate the detection probability of each sub-LOR into the model by calculating the penetration effect. For comparison, we used a standard LOR-based model and a Monte Carlo-based modeling approach, and evaluated the reconstructed images using both the National Electrical Manufacturers Association NU 4-2008 standards and the Geant4 Application for Tomographic Emission simulation toolkit (GATE). An average full width at half maximum (FWHM) at different locations of 1.77 mm and 1.79 mm are obtained using the proposed system model and standard LOR system model, which does not include penetration effects, respectively. The standard deviation of the uniform region in the NEMA image quality phantom is 2.14% for the proposed method and 14.3% for the LOR system model, indicating that the proposed model out-performs the standard LOR-based model.

An Empirical Study on the Analysis Model for Self Powered University Selection using University Information DB (대학 정보공시 데이터베이스(DB)를 활용한 자율개선대학선정 예측에 관한 실증연구)

  • Chae, Dong Woo;Jeon, Byung Hoon;Jung, Kun Oh
    • Journal of Information Technology Applications and Management
    • /
    • v.28 no.6
    • /
    • pp.97-116
    • /
    • 2021
  • Due to the decrease in the school-age population and government regulations, universities have made great efforts to secure their own competitiveness. In particular, the selection of universities with financial support based on the recent evaluation of the Ministry of Education has become a major concern enough to affect the existence of the university itself. This paper extracts three-year data from 124 major private universities nationwide, and quantitatively analyzes the variables of major universities selected as self-improvement universities, competency reinforcement universities, and universities with limited financial support. As a result of estimating the selection of self-powered universities using the ordered logit model by hierarchically inputting 12 variables, student competitiveness in the metropolitan area (1.318**), Educational Restitution Rate (4.078***), University operation expenditure index rate (1.088***) values were found. Significant positive coefficient values were found in the admission enrollment rate (45.98***) and the enrollment rate (13.25***). As a result of analyzing the marginal effects, the increase in the rate of reduction of education costs has always been positive in the selection of self-powered universities, but it was observed that the rate of increase decreases in areas of increase of 150% or more. On the contrary, the probability of becoming a Em-powered university was negative in all sectors, but on the contrary, it was analyzed that marginal effects increased at the same time point. On the other hand, the employment rate of graduates was not able to find direct significance with the result of the selection of Self powered universities. Through this paper, it is expected that each university will analyze the possibility and shortcomings of the selection of Self powered universities in policy making, and in particular, the risk of dropout of selection for the vulnerable field can be predicted using marginal effects. It can be used as major research data for both university evaluators, university officials and students.

The Effect Of EMS Combined Lower Limb Strengthening Training on the Quadriceps Femoris Muscle Activity of the Soccer Player (EMS를 결합한 다리 근력 강화훈련이 대학 축구선수의 넙다리네갈래근 근활성도에 미치는 영향)

  • Yo-han Uhm;Han-shin Jung;Yoon-hwan Kim
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.2
    • /
    • pp.49-57
    • /
    • 2023
  • Background: This study aims to investigate the effect of lower limb strengthening training combined with electro muscle stimulation on the quadriceps femoris muscle activity of soccer players. Methods: Thirty university soccer players were selected as study subjects and divided into a lower limb strengthening training group combined with EMS (Group I) and a general lower limb strengthening training group (Group II), and 15 subjects were randomly assigned. After receiving general soccer training, subjects in this study additionally mediated lower limb strengthening training combined with EMS and general lower limb strengthening training for 26 minutes, 3 times a week for 8 weeks. Quadriceps femoris muscle activity was analyzed before mediation. Vastus medialis, vastus lateralis, and rectus femoris were measured with maximum isometric contraction in the manual muscle test position in order to analyze leg muscle activity. The same items as above were re-measured and a between-group analysis was conducted after 8 weeks of mediation. Results: As a result of comparative analysis of lower extremity muscle activity between groups, the lower limb strengthening training group combined with EMS showed a statistically significant difference in lower extremity muscle activity compared to the general lower limb strengthening training group. Conclusion: As a result, it was found that lower limb strengthening training combined with EMS was more effective in improving quadriceps femoris muscle activity. Based on this study, we are going to provide basic data on the possibility of using EMS in the field of sports rehabilitation for soccer players.

  • PDF

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF

Time-lapse Geophysical Monitoring of $CO_2$ Sequestration (시간 경과에 따른 반복적 물리탐사 기법을 이용한 이산화탄소의 지중처리 모니터링)

  • Kim, Hee-Joon;Choi, Ji-Hyang;Han, Nu-Ree;Nam, Myung-Jin;Song, Yoon-Ho;Lee, Tae-Jong;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.4
    • /
    • pp.280-286
    • /
    • 2005
  • Geological sequestration of carbon dioxide ($CO_2$) is one of the most effective strategies far long-term removal of greenhouse gas from atmosphere. This paper reviews three projects for the $CO_2$ sequestration in geological formation. A unique $CO_2$ injection into a marine aquifer has been successfully monitored with repeated surface seismic measurements in the North Sea Sleipner West field. The seismic images reveal the extent and internal shape of the $CO_2$ bubble. Massive miscible $CO_2$ has been injected into a complex fractured carbonate reservoir at the Weyburn oil filed. High-resolution time-lapse P-wave data were successfully obtained to map the features of $CO_2$ movements within the two thin zones of different lithology. From the time-lapse crosswell EM imaging at the Lost Hills oil field in central California, U.S.A., the replacement of brine with $CO_2$ has been confirmed through a decrease of conductivity. The conductivity image was successfully compared with induction logs observed in the two wells.

Mutagenesis of Nodulation and Other Growth Characters with Ethyl Methanesulfonate in Soybean (EMS 처리에 관한 콩 근류착생 및 기타 형질의 돌연변이 출현 양상)

  • 이홍석;구자환;이석하;김석동
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.5
    • /
    • pp.442-448
    • /
    • 1993
  • The aims of the work were to examme the variability induced by EMS (ethyl methanesulfonate) mutagenesis of soybean plants, and to isolate mutants altered in nodulation and other growth characters. Seeds of two soybean cultivars, ‘Hwanggeumkong’ and ‘Baegunkong’ were treated with 30 and 50mM EMS(pH 7.0) for 6 hours and were planted directly in the field. Field emergency of$M_1 seed was averaged to be 61.0%, and frequency of plants with chlorophyll-deficient sectors of the first trifoliolate is about 0.7%. Regardless of varieties and does of EMS, $M_1 plant injury at harvest was present in plant height, pod and seed number per plant when compared to those of original-type soybean plants. The $M_2 variability of nodulation process induced by EMS treatment was found to be narrower than that of shoot dry weight. On the basis of the occurrence of chlorophyll-deficient plants, mutated cell frequency within $M_1 seed ranged from 5.3% to 84.2%, suggesting that mutation frequency on the $M_1 seed induced by EMS occurred partly and randomly regardless of varieties and doses of EMS. The putative mutant, which had more nodulation than original-type plant, was short in plant height. Sparse-nodulating soybean mutant was lower in leaf chlorophyll content and showed reduced growth.

  • PDF

The Effects of Metal Plate loaded on TLD chip in 6 MV Photon and 6 MeV Electron Beams (6 MV 광자선과 6 MeV 전자선 하에서 TLD 기판 위에 얹힌 금속 박막의 효과)

  • Kim, Sookil;Byungnim Min
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.41-46
    • /
    • 1999
  • There is necessity for making a smaller and more sensitive detector in small field sizes. This report assesses the suitability of metal-loaded thermoluminescent dosimeters for this purpose. Measurements were performed in the 6 MV photon and 6 MeV electron beams of a medical linear accelerator with LiF thermoluminescence dosimeters (TLD-100) embedded in solid water phantom. TLD-100 chips(surface area 3.2 $\times$ 3.2 $\textrm{mm}^2$) loaded with a metal plate(Tin or gold respectively) were used to enhance dose readings to TLD-100. Surface dose was measured for field size 10 $\times$ 10 $\textrm{cm}^2$ and 100 em SSD. Measurements have been made of the enhanced signal intensity and good linearity for absorbed dose with each metal. Using a 1 mm each metal on TLD-l00 in the beam increased the surface dose to 14% and 56% respectively for 6MV photon. In the case of 6 MeV electron, gold plate enhanced the TL response to 13%, but there is no difference for tin plate. The specific dose response of TLD-100 with thin metal plate increases with electron concentration of metal film, this is most likely due to increased electron scattered from the additional material with electron density higher than TLD-100. This emphasizes the role of TL dosimeters with metal as amplified dosimeters for therapeutic high energy x-ray beams. Due to the enhanced dose reading of TLD-100 with metal plate, it could be possible to develop smaller TL dosimeter with high sensitivity.

  • PDF

Performance of Direct Seeded Paddy Rice in Dry Soil at Different Seeding Depths (건답직파재배에서 부토심에 따른 벼 품종의 생육가 수량)

  • 이석순;백준호;김태주;홍승범
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.2
    • /
    • pp.174-182
    • /
    • 1993
  • Performance of 3 indica ${\times}$ japonica(Chilseungbyeo, Samgangbyeo, and Gayabyeo), 7 japonica(Yeongsanbyeo, Yeongdeugbyeo, Hwajinbyeo, Palgongbyeo, Seumjinbyeo, Tamjinbyeo, and Milyang 95), and 2 indica(Tebonnet and Lemont) rice varieties was tested at 1, 3, 5, and 7cm seeding depths in a growth chamber and field. In the growth chamber the number of days from seeding to seedling emergence increased as seeding depth increased, while percent germination and emergence and emergence / germination ratio decreased. However, in the field seedling emergence at 1em seeding depth delayed slightly compared to 3cm probably due to lack of soil moisture. The number of seedlings and maximum tillers at 1, 3, and 5cm seeding depths was similar, but it was higher compared to 7cm seeding depth. Yield and yield components were similar among the seeding depths when all the varieties averaged although 1,000-grain weight was slightly higher at 7cm deeding depth compared to others. At 1cm seeding depth the length of mesocotyl of all varieties was similar and ranged 0.1-0.2cm and that of coleptile ranged 0.8-1.1cm. As seeding depth increased up to 7cm Tebonnet which showed the highest percent emergence emerged by elongation of both mesocotyl and coleoptile, while the other varieties emerged largely by elongation of coleoptile.

  • PDF

Analysis of Radiation Characteristics on Offset Gregorian Antenna Using Jacobi-Bessel Series (Jacobi-Bessel 급수를 이용한 옵셋 그레고리안 안테나의 복사특성 해석)

  • Ryu, Hwang
    • The Journal of Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.5-14
    • /
    • 1997
  • The purpose of thesis is to analyze the radiation characteristics of an offset gregorian antenna in order to design the satellite-loaded antenna. In order to compute the radiation pattern of the sub-reflector, the reflected wave is obtained by GO(Geometric Optics) at an arbitrary shaped sub-reflector. Then the total radiation EM wave is obtained by summing the diffracted fields obtained by UTD(Uniform Geometrical Theory of Diffraction) and the GO fields. In order to calculate the far field radiation pattern of the main reflector, the radiation integral equation is derived from the induced current density on reflector surface using PO(Physical Optics). The kernel is expanded in terms of Jacobi-Bessel series for increasing the computational efficiency, then the modified radiation integral is represented as the double integral equation independent of observation points. When the incident fields are assumed to be x-or y-polarized field, the characteristics of radiation patterns in the gregorian antenna is analyzed in case of the main reflector having the focal length of 62.4$\lambda$, diameter of 100$\lambda$, and offset height of 75$\lambda$, and the sub-reflector having the eccentricity of 0.501, the inter focal length og 32.8$\lambda$, the horn axis angle of $9^{\circ}$ and the half aperture angle of $15.89^{\circ}$. The cross-polarized level and side lobe level in the offset geogorian reflector are reduced by 30dB and 10dB, respectively, in comparison with those of the offset parabolic antenna.

  • PDF