• Title/Summary/Keyword: ELISA.

Search Result 2,992, Processing Time 0.026 seconds

Production and Characterization of a Monoclonal Antibody Against Enrofloxacin

  • Chusri, Manaspong;Wongphanit, Pitikarn;Palaga, Tanapat;Puthong, Songchan;Sooksai, Sarintip;Komolpis, Kittinan
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.1
    • /
    • pp.69-75
    • /
    • 2013
  • Enrofloxacin is a fluoroquinolone antibiotic approved for the treatment of infections in animals. Because of the side effects to consumers of animal products, the maximum residue limits (MRLs) of enrofloxacin in animal tissues for consumption are regulated. In this study, a monoclonal antibody (mAb) against enrofloxacin was prepared and characterized for the development of a direct competitive enzyme-linked immunosorbent assay (ELISA). The obtained mAb, Enro44, was highly specific for enrofloxacin and had a 50% inhibition concentration ($IC_{50}$) of 1.99 ng/ml in a competitive ELISA, and the limit of detection (LOD) was 0.50 ng/ml. The cross-reactivity of the mAb with other quinolones and fluoroquinolones was lower than 0.01%. The subclass of the mAb Enro44 was identified as IgG1. The antigen (Ag)-captured direct competitive ELISA using the mAb Enro44 was tested on different spiked samples, including chicken muscle, cattle milk, and cattle urine, and the assay demonstrated recoveries of 82-112%, 80-125%, and 78-124%, respectively. Furthermore, the quantitation of enrofloxacin obtained from the ELISA and from high-performance liquid chromatography (HPLC) was in good agreement, with the linear regression coefficient between 0.933 and 1.056. The cDNAs encoding a heavy-chain Fd fragment (VH and CH1) and a light chain of the mAb Enro44 were cloned and sequenced. Taken together, the results obtained reveal a potential use of this mAb in an ELISA for the detection of enrofloxacin in food samples. The information of amino acid sequence of this mAb will be useful for further modification and production of the mAb in a bioreactor.

Optimalization of ELISA using Recombinant p27 Protein of SIV for Detection of Anti-SIV (SIV의 p27 재조합 단백질을 이용한 SIV 항체 검출을 위한 ELISA의 최적 조건)

  • Kim, Eun-ok;Kim, Eun;Oh, Yoon-i;Shin, Kwang-soon;Kim, Hyun-soo;Kim, Chul-joong
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.1
    • /
    • pp.101-108
    • /
    • 2002
  • The p27 coding region of the SIVmac239 isolate was amplified by PCR and cloned into an expression vector, pMAL-cri, which expressed high levels of the p27 protein from Escherichia coli. The purified p27 protein was used for detection of anti-SIV antibodies with the sera from 11 macaques and 21 marmosets by immunoblot assay of which one macaque was suspicious for the SIV infection. The optimum conditions of ELISA was studied by the check board system with the recombinant purified p27 protein. For the plate coating, 200ng/well of the purified p27 was satisfactory. The conjugate was diluted 1:1000. The sera from the 32 monkeys were negative for the anti-SIV by ELISA.

Diagnostic performance of enzyme-linked immnosorbent assays for diagnosing paratuberculosis in cattle: a meta-analysis

  • Pak, Son-Il
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.4
    • /
    • pp.669-676
    • /
    • 2004
  • To evaluate the diagnostic accuracy of two commercial ELISA tests (Allied- and CSL-ELISA) for the diagnosis of Mycobacterium paratuberculosis in cattle, Meta-analysis using English language papers published during 1990-2001 was performed. Diagnostic odds ratios (DOR) were analyzed using regression analysis together with summary receiver operating characteristic (ROC) curves. The difference in diagnostic performance between the two ELISA systems was evaluated by using linear regression. Publication bias was assessed by funnel plot and linear regression. The pooled sensitivity and specificity were 44% (95% CI, 38 to 51) and 98% (95% CI, 96 to 99) for the random-effect model. The DOR between studies was heterogeneous. The area under the fitted ROC curve (AUC) was 0.72 for the unweighted and 0.77 for the weighted model. Maximum joint sensitivity and specificity for the unweighted and weighted model from their summary ROC curve were 70% and 75%, respectively. Based on the fitted model, at a specificity of 95%, sensitivity was estimated to be 52% for the unweighted and 57% for the weighted model. From the final multivariable model study characteristic, the country was the only significant variable with an explained component variance of 13.3%. There were no significant differences in discriminatory power, sensitivity, and specificity between the two ELISA tests. The overall diagnostic accuracy of two commercial ELISA tests was moderate, as judged by the AUC, maximum joint sensitivity and specificity, and estimates from the fitted model and clinical usefulness of the tests for screening program is limited because of low sensitivity and heterogeneous of DOR. It is, therefore, recommended to use ELISA tests as a parallel testing with other diagnostic tests together to increase test sensitivity in the screening program.

Monoclonal Antibody-Based Dipstick Assay: A Reliable Field Applicable Technique for Diagnosis of Schistosoma mansoni Infection Using Human Serum and Urine Samples

  • Demerdash, Zeinab;Mohamed, Salwa;Hendawy, Mohamed;Rabia, Ibrahim;Attia, Mohy;Shaker, Zeinab;Diab, Tarek M.
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.1
    • /
    • pp.93-98
    • /
    • 2013
  • A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

Development of Sandwich ELISA for the Detection of Shrimp in Processed Foods (가공식품 중 새우의 검출을 위한 샌드위치 ELISA의 개발)

  • Do, Jeong-Ryong;Back, Su-Yeon;Shon, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.538-543
    • /
    • 2014
  • A sandwich enzyme-linked immunosorbent assay method (sELISA) for detecting the presence of shrimp in processed foods was developed using rabbit polyclonal antibodies against tropomyosin produced by black tiger prawns (shrimp). Based on the standard curve derived using this method, the detection range of shrimp was determined to be $1-100{\mu}g/mL$. The cross-reactivity of these antibodies toward black tiger prawns, fleshy prawns, cocktail prawns, lobster, and blue crab was 100, 73, 155, 18, and 0%, respectively. When shrimp was heated for 10 min, the mean assay recovery of tropomyosin was 121-221% at $70-100^{\circ}C$ and 7.8% at $121^{\circ}C$. When shrimp was added to cream soup, weaning food, sausage, fish paste, and sauce, the mean assay recovery was 397, 639, 168, 234, and 0%, respectively. In sample tests involving 14 commercial items, the coincidence ratio of assay results and reference was 79%.

Property Comparison of Polyclonal Anti-Soy Protein Antibodies Produced for ELISA (효소면역측정법을 위한 다클론 항대두단백 항체의 생산 및 특성비교)

  • Shon, Dong-Hwa;Kim, Hyun-Jung;Yun, Sung-Seob
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.1221-1226
    • /
    • 2000
  • Specific antibodies were produced to develope the enzyme-linked immunosorbent assay for analysis of soy proteins and the properties of the antibodies were compared. Isolate soy protein(ISP), and ISP heated with SDS and urea (ISP(SU)), acidic subunits(AS) of 11S globulin were immunized to produce polyclonal antibodies. By using competitive indirect ELISA(ciELISA), the reactivities of the antibodies toward soy proteins treated with different methods were investigated and shown as $IC_{50}$. $IC_{50}'s$ of anti-ISP antibodies to ISP, ISP(SU), ISP treated with 2-ME(ISP(ME)), and crude 11S were 20, 30, 36, and $1000\;{\mu}g/mL$, respectively. And the values of anti-ISP(SU) antibodies to the same antigens were 100, 5, 4, and $220\;{\mu}g/mL$ and those of anti-AS antibodies were 20, 2, 2.5, and $200\;{\mu}g/mL$, respectively. Therefore, anti-AS antibodies showed the highest reactivities toward soy proteins among the produced antibodies as determined by ciELISA.

  • PDF

Detection of a Thermal Stable-Soluble Protein (TSSP) as a Marker of Peanut Adulteration Using a Highly Sensitive Indirect Enzyme-Linked Immunosorbent Assay based on Monoclonal Antibodies

  • Sol-A Kim;Sazzad Hossen Toushik;Jeong-Eun Lee;Won-Bo Shim
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.9
    • /
    • pp.1170-1178
    • /
    • 2023
  • Food allergy represents a severe problem for many societies, including sensitive populations, academies, health authorities, and the food industry. Peanut allergy occupies a special place in the food allergy spectrum. To prevent consumption by consumers suffering from a peanut allergy, a rapid and sensitive detection method is essential to identify unintended peanut adulteration in processed foods. In this study, we produced four monoclonal antibodies (MAbs; RO 3A1-12, PB 4C12-10, PB 5F9-23, and PB 6G4-30) specific to thermo-stable and soluble proteins (TSSPs) of peanut and developed an enzyme-linked immunosorbent assay (ELISA) based on the MAbs. Among them, PB 5F9-23 MAb was firmly bound to Ara h 1, and other MAbs strongly reacted to Ara h 3 in the Western blot analysis. An antibody cocktail solution of the MAbs was used to enhance the sensitivity of an indirect ELISA, and the limit of detection of the indirect ELISA based on the antibody cocktail solution was 1 ng/ml and improved compared to the indirect ELISA based on the single MAb (11 ng/ml). The cross-reaction analysis revealed the high specificity of developed MAbs to peanut TSSPs without cross-reaction to other food allergens, including nuts. Subsequently, analyzing processed foods by indirect ELISA, all foods labeled as containing peanuts in the product description were confirmed to be positive. The results indicate that the developed antibodies exhibit high specificity and sensitivity to peanuts and can be used as bio-receptors in immunoassays or biosensors to detect intentional or unintentional adulteration of peanuts in processed foods, particularly heat-processed foods.

Prevalence of antibody and toxin against edema disease from pig farms in Jeonbuk province (전북지역 양돈장에서의 돼지 부종병 항체 및 톡신 양성률 조사)

  • Sun-Young Cho;Jeong Hee Yu;Yeong Ju Yu;Han-Jun Lee;Jin Hur
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.4
    • /
    • pp.325-334
    • /
    • 2023
  • Edema disease (ED) in pigs is enterotoxemia caused by Shiga toxin type 2e (Stx2e)-producing Escherichia coli (STEC) and frequently occurs in young piglets. Therefore, ED causes enormous economic losses in pig farms. In this study, a modified Stx2e (mStx2e) antigen was expressed and purified using commercial E. coli expression system. Monoclonal antibody was serviced by Ynto Ab Inc., using Phage Display Technique. Anti-Stx2e antibodies in piglets were measured by indirect ELISA using mStx2e antigens. Naive Stx2e in piglets were detected by Sandwich ELISA using Stx2e-monoclonal antibodies and commercial Stx2e-polyclonal antibodies. Among 3,480 piglets, anti-Stx2e antibodies were observed in 2,573 piglets. The 49.4% among 830 piglet serum samples possessed 0.625 ㎍/mL or more of Stx2e proteins. The 18.3% of 830 sera had 0.313 ㎍/mL of Stx2e proteins. The 32.3% of 830 samples held 0.156 ㎍/mL or less of Stx2e proteins. These results show that indirect ELISA using mStx2e antigen and Sandwich ELISA using Stx2e-monoclonal and polyclonal antibodies can be useful to detect ED in piglets.

Occurrence of Pome Fruit Viruses on Pear Trees (Pyrus pyrifolia) in Korea (국내에서 발생하는 배나무 바이러스병)

  • Cho, In-Sook;Kim, Dae-Huyn;Kim, Hyun-Ran;Chung, Bong-Nam;Cho, Jeom-Doeg;Choi, Gug-Seoun
    • Research in Plant Disease
    • /
    • v.16 no.3
    • /
    • pp.326-330
    • /
    • 2010
  • Three pome fruit viruses, Apple chlorotic leaf spot virus (ACLSV), Apple stem grooving virus (ASPV) and Apple stem pitting virus (ASGV) were detected in pear trees (Pyrus pyrifolia) using double antibody sandwich enzyme-linked immunosorbent assay (DAS-ELISA) in Ansung, Naju and Ulsan provinces of Korea. Infection rate of three viruses was 35.2% from 452 leaf samples of the three cultivars of pear trees. Also, each of three viruses was detected by reverse transcription polymerase chain reaction (RT-PCR) for a limited number of samples. Infection rate of three viruses was 86.3% from 233 leaf samples of the three pear cultivars. The virus infection rates by RT-PCR were much higher than ELISA. ASGV was prevailing on pear with 74.2%, whereas ASPV and ACLSV were found in 34.8% and 0.4% of tested samples, respectively. Symptoms caused by ASGV showed black spots of infected Niitaka cultivar leaves. The ACLSV, ASPV and ASGV isolates showed 83~94% sequence identity at a nucleotide level to other pome fruit virus isolates when analyzed by NCBI BLAST. Pome fruit viruses occurring in pear were ACLSV, ASPV and ASGV. This is the first report of pear trees infected ASPV in Korea.

Application of Oral Fluid Sample to Monitor Porcine circovirus-2 Infection in Pig Farms (구강액을 이용한 양돈장의 Porcine circovirus-2 감염에 대한 모니터링)

  • Kim, Won-Il
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.704-712
    • /
    • 2010
  • Porcine circovirus-2 (PCV2) has been implicated in many clinical diseases/syndromes that are now referred to as PCV-associated diseases (PCVAD). Due to significant economic losses caused by PCVAD, many swine operations have launched extensive monitoring programs for PCV2. Traditional serum sampling is, however, rather expensive and laborious, hampering effective large scale pathogen surveillance. A field-based longitudinal study was conducted to assess the utility of pen-based oral fluid sample as an alternative to serum for herd PCV2 testing. Six pens (25 pigs/pen) at each of 3 different sites were used in the study. One oral fluid and 5 random serum samples per pen were collected at 3, 5, 8, 12, and 16 weeks of age, and the sera were pooled by pen for testing. All samples were tested for PCV2 by real-time PCR and for antibodies by indirect fluorescent antibody test (for both anti-PCV2 IgG and IgA) and 3 ELISA assays (blocking ELISA, indirect ELISA, and IgG/IgM sandwich ELISA). PCV2 DNA was detected in oral fluid samples sporadically until 8 weeks and in all pens at 16 weeks. PCV2-specific IgG was detected in oral fluid samples at 3 weeks and persisted until 5 to 8 weeks in all sites. Anti-PCV2 IgG and IgA were detectable in oral fluid samples collected at 16 weeks from all of the pens at 1 site. The detection of PCV2 and anti-PCV2 antibody in oral fluid samples correlated positively with results on pooled sera, suggesting that oral fluids can be a cost-effective alternative to serum for herd monitoring of PCV2 infection.