International Journal of Fluid Machinery and Systems
/
v.7
no.4
/
pp.142-150
/
2014
In the cardiopulmonary support system with an ECMO (extracorporeal membrane oxygenation), a higher pump head is demanded for a blood pump. In order to realize a blood pump with higher pump head, higher anti-hemolysis and thrombosis performances, a study on the development of unprecedented multistage blood pump was conducted. In consideration of the application of the blood pump for pediatric patients, a miniature two-stage centrifugal blood pump with the impeller's diameter of 40mm was designed and the performance was examined in experiments and computations. Some useful knowledge for a design of the blood pump with higher anti-hemolysis and thrombosis performances was obtained.
Bronchogenic carcinoma involving the carina has remained a challenging problem for thoracic surgeons. Carinal resection and reconstruction is limitedly indicated because this aggressive surgical approach has been reported to be associated with significant morbidity and mortality while long-term outcome has not been determined. Wesuccessfully performed carinal reconstruction and sleeve right upper lobectomy assisted with ECMO for a 60-year-old male with squamous cell carcinoma in the right upper lobe extending to the carina.
Park, Sang Yoong;Rim, Jong Cheol;Cho, Hyun Chul;Lee, Yoon Chan;Kim, Jung A;Choi, So Ron
Kosin Medical Journal
/
v.33
no.2
/
pp.215-222
/
2018
An incidentaloma is a tumor found incidentally without clinical symptoms or suspicion; the lesion may be adrenal, pituitary, or thyroidal. We report the case of an asymptomatic individual with preoperatively undiagnosed pheochromocytoma (size: 4.86 cm) that was revealed using elective nonadrenal surgical procedures. The patient demonstrated peri- and post-operative hypertensive crisis and tachycardia. Three days after the dramatic onset of symptoms, the patient expired due to pulmonary edema, multiple organ failure, and terminal sepsis, despite administration of extracorporeal membrane oxygenation-assisted cardiopulmonary resuscitation. A left medial kidney mass obtained at autopsy confirmed pheochromocytoma.
Yu, Min Sang;Jang, Yeonsook;Kim, Muhwan;Cho, Sungbo
Journal of Biomedical Engineering Research
/
v.42
no.4
/
pp.193-200
/
2021
Flowmeter and oxygen sensors are listed in COVID-19 essential medical devices. This article reports a Teensy microcontroller-based Oxygen mass flow controller (MFC), core part of the oxygen respirator or extracorporeal membrane oxygenation (ECMO). The developed MFC consisting of the microcontroller, MEMS flow sensor, and solenoid valve was able to accurately control 0 to 100 sccm of oxygen flow rate. The pressure of vacuum chamber increased proportionally to the flow rate (0.998 of Pearson correlation coefficient). The experimental results proved that the developed MFC exhibits comparable performance to a commercial MFC in accuracy, settling time, linearity with pressure, and repeatability of oxygen mass flow control. It is expected that this simple and cheap MFC is utilized for oxygen therapy against the severe acute respiratory syndrome coronavirus 2.
The use of the lung assist device (LAD) would be well suited for acute respiratory failure (ARF) patients, combining the simplicity of mechanical ventilation with the ability of extracoporeal membrane oxygenators (ECMO) to provide temporary relief for the natural lungs. This study's specific attention was focused on the effect of membrane vibration in the LAD. Quantitative experimental measurements were performed to evaluate the performance of the device, and to identify membrane vibration dependence on blood hemolysis. We tried to decide upon excited frequency band of limit hemolysis when blood hemolysis came to through a membrane vibration action. The excited frequency of the module type 5, consisted of 675 hollow fiber membranes, showed the maximum gas transfer rate. We concluded that the maximum oxygen transfer rate seemed to be caused by the occurrence of maximum amplitude and the transfer of vibration to hollow fiber membranes. It was excited up to $25{\pm}5$ Hz at each blood flow rate of module type 5. We found that this frequency became the 2nd mode resonance riequency of the flexible in blood flow. Blood hemolysis was low at the excited frequency of $25{\pm}5$ Hz. Therefore, we decided that limit hemolysis frequency of this LAD was $25{\pm}5$ Hz.
Yoo, Jung-Wan;Ju, Sunmi;Lee, Seung Jun;Cho, Min-Chul;Cho, Yu Ji;Jeong, Yi Yeong;Lee, Jong Deog;Kim, Ho Choel
Tuberculosis and Respiratory Diseases
/
v.82
no.4
/
pp.328-334
/
2019
Background: Although the frequency of respiratory viral infection in patients with pulmonary acute respiratory distress syndrome (ARDS) is not uncommon, clinical significance of the condition remains to be further elucidated. The purpose of this study was to compare characteristics and outcomes of patients with pulmonary ARDS infected with influenza and other respiratory viruses. Methods: Clinical data of patients with pulmonary ARDS infected with respiratory viruses January 2014-June 2018 were reviewed. Respiratory viral infection was identified by multiplex reverse transcription-polymerase chain reaction (RT-PCR). Results: Among 126 patients who underwent multiplex RT-PCR, respiratory viral infection was identified in 46% (58/126): 28 patients with influenza and 30 patients with other respiratory viruses. There was no significant difference in baseline and clinical characteristics between patients with influenza and those with other respiratory viruses. The use of extracorporeal membrane oxygenation (ECMO) was more frequent in patients with influenza than in those with other respiratory viruses (32.1% vs 3.3%, p=0.006). Co-bacterial pathogens were more frequently isolated from respiratory samples of patients with pulmonary ARDS infected with influenza virus than those with other respiratory viruses. (53.6% vs 26.7%, p=0.036). There were no significant differences regarding clinical outcomes. In multivariate analysis, acute physiology and chronic health evaluation II was associated with 30-mortality (odds ratio, 1.158; 95% confidence interval, 1.022-1.312; p=0.022). Conclusion: Respiratory viral infection was not uncommon in patients with pulmonary ARDS. Influenza virus was most commonly identified and was associated with more co-bacterial infection and ECMO therapy.
Purpose: The purpose of this study was to investigate in-service education needs in order to develop clinical competence of critical care nurses', and to identify contents which have to include in-service education according to nurses' characteristics. Methods: Data was collected using Critical Care Nurse Job Analysis Tool that was modified by professional team. Collected data was analyzed using the SPSS program. Results: Total 148 critical care nurses, who had worked at adult intensive care unit of one tertiary hospital in Seoul, filled out questionnaire. The results showed the participants highly needed education about cardiological nursing practices such as ECMO, pacemaker, cardiac tamponade. And there were significant correlations among in-service educational needs and ICU careers, preceptors experience, and charge nurse experience. Conclusion: It will be necessary for better nursing to develop in-service education is based on critical care nurse's need and their characteristics. Especially, it is important to develop and provide in-service education programs, which consider ICU nurse's differences for their career ladder and nursing preceptors.
International Journal of Fluid Machinery and Systems
/
v.8
no.1
/
pp.1-12
/
2015
In cardiopulmonary support systems with a membrane oxygenation such as a percutaneous cardiopulmonary support (PCPS) or an extracorporeal membrane oxygenation (ECMO), blood pumps need to generate the pressure rise of approximately 200mmHg or higher, due to the high hydraulic resistances of the membrane oxygenation and of the cannula tubing. In order to realize the blood pump with higher pressure rise, higher anti-hemolysis and thrombosis performances, the development of novel centrifugal blood pump composed of two-stage has been conducted by the authors. In the present paper, effective attempts to decrease the wall shear stress and to suppress the stagnation are introduced for the prevention of hemolysis and thrombosis in blood pumps. The hemolysis test was also carried out and it was clarified that the decrease of wall shear stress is effective as a guideline of design of blood pumps for improving the anti-hemolysis performance.
A blood pump is an important part of a cardiac assist device. Since the shear rate in blood is known to be a primary factor on hemolysis generation, it has been very important to evaluate hemolysis inside blood pumps for understanding performance and reliability of cardiac assist devices. In this study, hemolysis generation inside blood pumps is analyzed using CFD with power-law based models for the blood damage index(BDI), in order to overcome difficulties in measuring hemolysis by experiment. The BDI values in blood pumps can be evaluated using Lagrangian or Eulerian approaches. In this study, several Lagrangian and Eulerian approaches are compared to estimate the efficiency of the numerical methods in a practice sense. It is found that the Eulerian approaches are advantageous in terms of the efficiency and robustness. Two different Eulerian approaches are used to evaluate the BDI values of a few commercial blood pumps. For the conditions of extracorporeal membrane oxygenator(ECMO) and ventricular assist device(VAD), local generation of hemolysis is analyzed using divided regions of blood pumps, in order to investigate the effects of the pump geometry.
Over the past four decades after World War II a great deal of data and clinical experiences have been accumulated relating to the diagnosis and surgical treatment of cardiovascular diseases in Korea. Clinical data after the first open heart surgery by Professor Yung Kyoon Lee on August 7, 1959 up to 1984 revealed the total number of cardiovascular surgery in Korea as 13,100 cases performed in 22 institutes with overall hospital mortality of 7.7%[Cardiovascular Surgery in Korea 1985], Publishing committee of the Korean Thoracic and Cardiovascular Surgical Society collected the data of cardiovascular surgical cases in Korea again in between 1985 and 1990 from 38 institutes out of total 42 institutes of open heart centers in Korea. The results are: 1. The survey reply ratio was 90.5%[38 out of 42 institutes]. 2. Of the total 30,061 cases of cardiovascular surgery reported from 38 institutes 1,402 cases were failed as hospital mortality of 4.7%[4.5% of the 21,761 operations for congenital, and 5.2% of the 8,300 operations for acquired heart diseases]. Out of the total congenital cases, 17,303 cases were acyanotic group with a operative mortality as 2.0%, and 4,458 cases were cyanotic group with a hospital mortality as 14.le The incidence of corrective operations for complex congenital cardiac anomalies were increasing recently with decreasing age group. 3. During the year in 1990, 38 institutes performed 5,427 cardiovascular surgery with a hospital mortality of 3.4%. 4. Of the total cumulative 6,458 cases for cardiac valve surgery more than 90% cases were put to prosthetic valve replacement with hospital mortality as 4.8%. And the incidence of re-Do valve surgery was increasing recently as 13.1% in 1990. 5. Coronary artery bypass graft was increasing recently with 7.9% of hospital mortality in total 440 cases. Intracardiac operation for intractable arrhythmia was started since 1987 as 49 cases in total. Experiences on VAD and ECMO were also reported sporadically in recent year. 6. Home made oxygenator[OXYREX] is now in clinical use, and under animal experiment for clinical trial in near future.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.