색채 조명 자극이 인지기능에 미치는 영향에 관한 연구 (Study on the Effect of Cognitive Function by Color Light Stimulation)

  • 정우석;유미;권대규;김남균
    • 한국정밀공학회지
    • /
    • 제24권10호
    • /
    • pp.131-136
    • /
    • 2007
  • In this paper, we estimated the effects of different color stimulation on the cognitive function of human quantitatively. For the stimulations we used color lights with 6 color filters such as red, yellow, green, blue, violet and white. The experiment was performed in a soundproof chamber. 50 young male and female subjects were participated in the experiment. To find the appropriate color cognitive function, the endogenous visuospatial attention task(EVAT) and one back working memory task(OWMT) were performed. The reaction time and accuracy degree were measured. The results showed that the reaction time of EVAT was the fastest and the accuracy degree of attention task was the highest in green environment. The reaction time of OWMT was the fastest in yellow and the accuracy degree of memory task was the highest in blue. For physiological parameters, we measured electrocardiogram(ECG) and HRV spectrum analysis, HF/LF color environment. These results can be used as an indicator in the design of color environment and clinical applications.

심장내과 병동의 텔레메트리 적용 환자 특성 (Characteristics of Patients Undergoing Telemetry in the Cardiology Ward)

  • 김윤선;최혜란
    • 중환자간호학회지
    • /
    • 제7권2호
    • /
    • pp.14-23
    • /
    • 2014
  • Purpose: The purpose of this study was to provide basic information to develop appropriate nursing guidelines for cardiac telemetry. Methods: This retrospective research was conducted to identify the current usage of cardiac telemetry and considered 1,000 patients hospitalized for telemetry. The collected data were analyzed using IBM (SPSS Statistics for Windows 21.0). Results: Four-hundred and ninety-two patients (49.2%) were diagnosed with arrhythmia and 209 (20.9%) with heart failure. Electrocardiogram (ECG) rhythm changes were detected via telemetry in 464 cases. Major arrhythmias were ventricular tachycardia (183, 39.4%) and bradycardia (99, 21.3%). Interventions after detecting arrhythmia were cardioversion (16, 3.4%), defibrillation (1, 0.2%), and cardiopulmonary cerebral resuscitation (5, 1.1%); other patients were treated conservatively with close observation (381, 82.1%). Conclusion: There was appropriate intervention in 46.4% of the considered cases with the detection of ECG changes before patient notification, which implied that cardiac telemetry could be considered for application to patients with hemodynamic instability. Clear standards and guidelines are required to determine who requires telemetry and when to end the telemetry monitoring.

  • PDF

심전도 신호기반 개인식별을 위한 텐서표현의 다선형 판별분석기법 (A Multilinear LDA Method of Tensor Representation for ECG Signal Based Individual Identification)

  • 임원철;곽근창
    • 스마트미디어저널
    • /
    • 제7권4호
    • /
    • pp.90-98
    • /
    • 2018
  • 심전도 신호는 기본적으로 심장의 전기적 활동에 포함되며 이를 통해 심박수 측정, 심장 박동의 리듬 검사, 심장 이상 진단, 정서 인식 및 생체 인식과 같은 다양한 목적으로 분석 및 활용된다. 본 논문의 목적은 다차원 데이터 배열인 텐서 특성을 가진 다선형 판별분석(MLDA: Multilinear Linear Discriminant Analysis) 기법을 이용하여 개인식별을 수행하고자 한다. MLDA는 상위 차원의 텐서를 포함하는 분류 문제에 대해서 차원 문제를 해결 할 수 있으며, 상호 연관된 부분 공간은 서로 다른 클래스를 구별하기 위해 사용될 수 있다. 제시된 방법의 성능을 검증하기 위해 Physionet의 MIT-BIH데이터베이스를 적용하였다. 이 데이터베이스에 대해 실험한 결과, MLDA는 기존 PCA와 LDA와 비교하여 개인식별 성능이 우수함을 확인하였다.

심전도와 맥파 신호 검출을 위한 일체형 센서 시스템의 구현 (The Development of Integrated Sensor System for Measuring Simultaneously ECG, PPG and PPW)

  • 전계록;정동근;김기련;신범주
    • 한국산학기술학회논문지
    • /
    • 제10권5호
    • /
    • pp.992-999
    • /
    • 2009
  • 심전도와 맥파를 측정함으로써 구해질 수 있는 맥파전달시간은 심혈관계의 상태를 진단하기 위한 의미 있는 지표가 된다. 그러나 맥파를 측정하는 동안 움직이거나, 측정 시에 가해지는 압력이 부정확할 경우, 잘못된 측정 결과를 얻을 수 있다. 이를 해결하기 위하여 본 논문에서는 심전도, 압력맥파 및 광전용적맥파를 동시에 측정할 수 있는 일체형 센서 시스템과 심전도를 지속적으로 측정할 수 있는 금속 전극을 개발하였으며, 실험을 통해 일체형 센서시스템 및 금속 전극의 유용성을 입증하였다.

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

청심연자탕(淸心蓮子湯)이 심전도(心電圖) 변화(變化)에 미치는 영향(影響)에 관한 연구(硏究) (A study of the effects of Cheongsimyeonjatang (CYT) on ECG in comparing before and after CYT medication: Case study of hospitalized Taeumin patients)

  • 배영춘;이상민;김경요;김형순
    • 사상체질의학회지
    • /
    • 제15권3호
    • /
    • pp.147-157
    • /
    • 2003
  • The purpose of this study is to examine the effects of Sasang constitutional herbal extracts, Cheongsimyeonjatang(CYT) on ECG(electrocardiogram). For this purpose, Ten hospitalized Taeumin patients were selected and changes of the ECG was investigated. The researcher also measured and observed ECG changes before and after CYT medication. The following is the summarized results of study. 1. The RV5+SV1 voltage was decreased in LVH patients. 2. The S-T voltage was decrease in the previous S-T elevated patients. 3. The heart rate was increased in the patients of lower heart rate than normal. 4. There was no remarkable change after medication on T-inversion and bundle branch block. From the above results, it is concluded that Cheongsimyeonjatang(CYT) have influenced on ECG.

  • PDF

Electrode Characteristics of Non-contact Electrocardiographic Measurement

  • Mathias, Dakurah Naangmenkpeong;Kim, Sung-Il;Park, Jae-Soon;Joung, Yeun-Ho;Choi, Won Seok
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권1호
    • /
    • pp.42-45
    • /
    • 2015
  • The ability to take electrocardiographic measurements while performing our daily activities has become the people-choice for modern age vital sign sensing. Currently, wet and dry ECG electrodes are known to pose threats like inflammations, allergic reactions, and metal poisoning due to their direct skin interaction. Therefore, the main goal in this work is to implement a very small ECG sensor system with a capacitive coupling, which is able to detect electrical signals of heart at a distance without the conductive gel. The aim of this paper is to design, implement, and characterize the contactless ECG electrodes. Under a careful consideration of factors that affect a capacitive electrode functional integrity, several different sizes of ECG electrodes were designed and tested with a pilot ECG device. A very small cotton-insulated copper tape electrode ($2.324cm^2$) was finally attained that could detect and measure bioelectric signal at about 500 um of distance from the subject's chest.

Nonlinear Quality Indices Based on a Novel Lempel-Ziv Complexity for Assessing Quality of Multi-Lead ECGs Collected in Real Time

  • Zhang, Yatao;Ma, Zhenguo;Dong, Wentao
    • Journal of Information Processing Systems
    • /
    • 제16권2호
    • /
    • pp.508-521
    • /
    • 2020
  • We compared a novel encoding Lempel-Ziv complexity (ELZC) with three common complexity algorithms i.e., approximate entropy (ApEn), sample entropy (SampEn), and classic Lempel-Ziv complexity (CLZC) so as to determine a satisfied complexity and its corresponding quality indices for assessing quality of multi-lead electrocardiogram (ECG). First, we calculated the aforementioned algorithms on six artificial time series in order to compare their performance in terms of discerning randomness and the inherent irregularity within time series. Then, for analyzing sensitivity of the algorithms to content level of different noises within the ECG, we investigated their change trend in five artificial synthetic noisy ECGs containing different noises at several signal noise ratios. Finally, three quality indices based on the ELZC of the multi-lead ECG were proposed to assess the quality of 862 real 12-lead ECGs from the MIT databases. The results showed the ELZC could discern randomness and the inherent irregularity within six artificial time series, and also reflect content level of different noises within five artificial synthetic ECGs. The results indicated the AUCs of three quality indices of the ELZC had statistical significance (>0.500). The ELZC and its corresponding three indices were more suitable for multi-lead ECG quality assessment than the other three algorithms.

심전도 및 수면시 체동 측정 모듈 장착을 위한 브래지어 프로토타입 개발 (A Development of Brassiere Prototype for Attaching the Measuring Module of ECG and Body Movement while Sleeping)

  • 권수애;손부현
    • 패션비즈니스
    • /
    • 제21권2호
    • /
    • pp.78-90
    • /
    • 2017
  • In this study, brassiere prototype was developed for attaching the measuring module of ECG measurement and body movement while sleeping. For ECG measurement, textile electrodes was made of stretch fabric containing polyurethane in consideration of elasticity of brassiere band. It was used as a conductive yarn by silver coating on the warp. The textile electrodes was woven with twisted twill to increase the density of conductive yarns. The pressure of the brassiere band was enough to sensing stably the ECG, and the elastic band of the brassiere was designed to be wider than 3cm to install the textile electrodes inside, so that textile electrodes was close fitting to the skin at a constant pressure without lifting. The textile electrodes coated with silicon on rear was attached to brassiere elastic band, and the module was installed with a snap connector to textile electrodes of brassiere band. The module was suitable to monitering ECG measurement of a typical R peak, pulse rate and body movement while sleeping without interfering.

PQRST파 특징 기반 신호의 분류를 이용한 심전도 압축 알고리즘 성능 평가 (Performance Evaluation of ECG Compression Algorithms using Classification of Signals based PQSRT Wave Features)

  • 구정주;최광석
    • 한국통신학회논문지
    • /
    • 제37권4C호
    • /
    • pp.313-320
    • /
    • 2012
  • 심전도의 압축은 시스템의 처리 속도를 높일 뿐만 아니라 신호의 전송량, 장기적인 기록 데이터 저장량을 줄일 수 있다. 본 논문에서는 기존의 심전도 데이터의 손실 혹은 무 손실 압축 알고리즘에 대한 성능 평가가 엔지니어의 관점에서 PRD(Percent RMS Difference)와 CR(Compression Ratio)을 측정하였다면 심전도를 진단하는 진단자의 관점에서 압축의 성능 평가에 대한 연구를 하였다. 일반적으로 심전도 데이터의 압축이 진단에 영향을 미치지 않게 하기위해서는 압축 후 복원된 PQRST파의 위치, 길이, 진폭, 파의 형태 등 진단에 필요한 것들이 손상되어선 안 된다. 대표적인 심전도 압축 알고리즘 AZTEC은 기존의 성능평가에 그 효율성이 검증되었지만 진단자의 관점에서 새로운 성능평가를 제시한다.