In this paper, we estimated the effects of different color stimulation on the cognitive function of human quantitatively. For the stimulations we used color lights with 6 color filters such as red, yellow, green, blue, violet and white. The experiment was performed in a soundproof chamber. 50 young male and female subjects were participated in the experiment. To find the appropriate color cognitive function, the endogenous visuospatial attention task(EVAT) and one back working memory task(OWMT) were performed. The reaction time and accuracy degree were measured. The results showed that the reaction time of EVAT was the fastest and the accuracy degree of attention task was the highest in green environment. The reaction time of OWMT was the fastest in yellow and the accuracy degree of memory task was the highest in blue. For physiological parameters, we measured electrocardiogram(ECG) and HRV spectrum analysis, HF/LF color environment. These results can be used as an indicator in the design of color environment and clinical applications.
Purpose: The purpose of this study was to provide basic information to develop appropriate nursing guidelines for cardiac telemetry. Methods: This retrospective research was conducted to identify the current usage of cardiac telemetry and considered 1,000 patients hospitalized for telemetry. The collected data were analyzed using IBM (SPSS Statistics for Windows 21.0). Results: Four-hundred and ninety-two patients (49.2%) were diagnosed with arrhythmia and 209 (20.9%) with heart failure. Electrocardiogram (ECG) rhythm changes were detected via telemetry in 464 cases. Major arrhythmias were ventricular tachycardia (183, 39.4%) and bradycardia (99, 21.3%). Interventions after detecting arrhythmia were cardioversion (16, 3.4%), defibrillation (1, 0.2%), and cardiopulmonary cerebral resuscitation (5, 1.1%); other patients were treated conservatively with close observation (381, 82.1%). Conclusion: There was appropriate intervention in 46.4% of the considered cases with the detection of ECG changes before patient notification, which implied that cardiac telemetry could be considered for application to patients with hemodynamic instability. Clear standards and guidelines are required to determine who requires telemetry and when to end the telemetry monitoring.
심전도 신호는 기본적으로 심장의 전기적 활동에 포함되며 이를 통해 심박수 측정, 심장 박동의 리듬 검사, 심장 이상 진단, 정서 인식 및 생체 인식과 같은 다양한 목적으로 분석 및 활용된다. 본 논문의 목적은 다차원 데이터 배열인 텐서 특성을 가진 다선형 판별분석(MLDA: Multilinear Linear Discriminant Analysis) 기법을 이용하여 개인식별을 수행하고자 한다. MLDA는 상위 차원의 텐서를 포함하는 분류 문제에 대해서 차원 문제를 해결 할 수 있으며, 상호 연관된 부분 공간은 서로 다른 클래스를 구별하기 위해 사용될 수 있다. 제시된 방법의 성능을 검증하기 위해 Physionet의 MIT-BIH데이터베이스를 적용하였다. 이 데이터베이스에 대해 실험한 결과, MLDA는 기존 PCA와 LDA와 비교하여 개인식별 성능이 우수함을 확인하였다.
심전도와 맥파를 측정함으로써 구해질 수 있는 맥파전달시간은 심혈관계의 상태를 진단하기 위한 의미 있는 지표가 된다. 그러나 맥파를 측정하는 동안 움직이거나, 측정 시에 가해지는 압력이 부정확할 경우, 잘못된 측정 결과를 얻을 수 있다. 이를 해결하기 위하여 본 논문에서는 심전도, 압력맥파 및 광전용적맥파를 동시에 측정할 수 있는 일체형 센서 시스템과 심전도를 지속적으로 측정할 수 있는 금속 전극을 개발하였으며, 실험을 통해 일체형 센서시스템 및 금속 전극의 유용성을 입증하였다.
JSTS:Journal of Semiconductor Technology and Science
/
제16권5호
/
pp.702-712
/
2016
A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.
The purpose of this study is to examine the effects of Sasang constitutional herbal extracts, Cheongsimyeonjatang(CYT) on ECG(electrocardiogram). For this purpose, Ten hospitalized Taeumin patients were selected and changes of the ECG was investigated. The researcher also measured and observed ECG changes before and after CYT medication. The following is the summarized results of study. 1. The RV5+SV1 voltage was decreased in LVH patients. 2. The S-T voltage was decrease in the previous S-T elevated patients. 3. The heart rate was increased in the patients of lower heart rate than normal. 4. There was no remarkable change after medication on T-inversion and bundle branch block. From the above results, it is concluded that Cheongsimyeonjatang(CYT) have influenced on ECG.
Mathias, Dakurah Naangmenkpeong;Kim, Sung-Il;Park, Jae-Soon;Joung, Yeun-Ho;Choi, Won Seok
Transactions on Electrical and Electronic Materials
/
제16권1호
/
pp.42-45
/
2015
The ability to take electrocardiographic measurements while performing our daily activities has become the people-choice for modern age vital sign sensing. Currently, wet and dry ECG electrodes are known to pose threats like inflammations, allergic reactions, and metal poisoning due to their direct skin interaction. Therefore, the main goal in this work is to implement a very small ECG sensor system with a capacitive coupling, which is able to detect electrical signals of heart at a distance without the conductive gel. The aim of this paper is to design, implement, and characterize the contactless ECG electrodes. Under a careful consideration of factors that affect a capacitive electrode functional integrity, several different sizes of ECG electrodes were designed and tested with a pilot ECG device. A very small cotton-insulated copper tape electrode ($2.324cm^2$) was finally attained that could detect and measure bioelectric signal at about 500 um of distance from the subject's chest.
We compared a novel encoding Lempel-Ziv complexity (ELZC) with three common complexity algorithms i.e., approximate entropy (ApEn), sample entropy (SampEn), and classic Lempel-Ziv complexity (CLZC) so as to determine a satisfied complexity and its corresponding quality indices for assessing quality of multi-lead electrocardiogram (ECG). First, we calculated the aforementioned algorithms on six artificial time series in order to compare their performance in terms of discerning randomness and the inherent irregularity within time series. Then, for analyzing sensitivity of the algorithms to content level of different noises within the ECG, we investigated their change trend in five artificial synthetic noisy ECGs containing different noises at several signal noise ratios. Finally, three quality indices based on the ELZC of the multi-lead ECG were proposed to assess the quality of 862 real 12-lead ECGs from the MIT databases. The results showed the ELZC could discern randomness and the inherent irregularity within six artificial time series, and also reflect content level of different noises within five artificial synthetic ECGs. The results indicated the AUCs of three quality indices of the ELZC had statistical significance (>0.500). The ELZC and its corresponding three indices were more suitable for multi-lead ECG quality assessment than the other three algorithms.
In this study, brassiere prototype was developed for attaching the measuring module of ECG measurement and body movement while sleeping. For ECG measurement, textile electrodes was made of stretch fabric containing polyurethane in consideration of elasticity of brassiere band. It was used as a conductive yarn by silver coating on the warp. The textile electrodes was woven with twisted twill to increase the density of conductive yarns. The pressure of the brassiere band was enough to sensing stably the ECG, and the elastic band of the brassiere was designed to be wider than 3cm to install the textile electrodes inside, so that textile electrodes was close fitting to the skin at a constant pressure without lifting. The textile electrodes coated with silicon on rear was attached to brassiere elastic band, and the module was installed with a snap connector to textile electrodes of brassiere band. The module was suitable to monitering ECG measurement of a typical R peak, pulse rate and body movement while sleeping without interfering.
심전도의 압축은 시스템의 처리 속도를 높일 뿐만 아니라 신호의 전송량, 장기적인 기록 데이터 저장량을 줄일 수 있다. 본 논문에서는 기존의 심전도 데이터의 손실 혹은 무 손실 압축 알고리즘에 대한 성능 평가가 엔지니어의 관점에서 PRD(Percent RMS Difference)와 CR(Compression Ratio)을 측정하였다면 심전도를 진단하는 진단자의 관점에서 압축의 성능 평가에 대한 연구를 하였다. 일반적으로 심전도 데이터의 압축이 진단에 영향을 미치지 않게 하기위해서는 압축 후 복원된 PQRST파의 위치, 길이, 진폭, 파의 형태 등 진단에 필요한 것들이 손상되어선 안 된다. 대표적인 심전도 압축 알고리즘 AZTEC은 기존의 성능평가에 그 효율성이 검증되었지만 진단자의 관점에서 새로운 성능평가를 제시한다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.