• Title/Summary/Keyword: E-J power

Search Result 823, Processing Time 0.033 seconds

Improvement of ITO etching uniformity in a large area plasma source (대면적 플라즈마 소스에서의 ITO 식각균일도 향상)

  • Kim, C.W.;Jo, S.B.;Kim, B.J.;Park, S.G.;O, B.H.;Lee, J.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.145-148
    • /
    • 2001
  • A large area plasma source using parallel $2{\times}2$ ICP antennas showed improved etching uniformity by the E-ICP operation. ITO etching process with $CH_4$ gas chemistry is optimized with the DOE (Design of Experiment) based on Taguchi method. Various methane ratios in methane and argon mixture are compared to confirm the effect of polymerization. The analysis shows that the effect of bias power is the largeset. We obtained higher ITO etching rate and better uniformity on $350{\times}300mm$ substrate at the 50Hz magnetization frequency of the E-ICP operation technique,

  • PDF

Development of Model $SF_6$ GCB for 800kV GIS (800kV GIS용 모델 가스 차단기의 개발)

  • Song, W.P.;Kim, J.B.;Lee, C.H.;Noh, C.W.;Shin, Y.J.;Park, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.55-56
    • /
    • 1994
  • KEPCO is now driving forward the raising of transmission-line-voltage from 345kV to 765kV for the stabilization of network and as the counter measure of the rapid-increasing of domestic electric power demands. 800kV GIS is one of the most important apparatuses in the 765kV substation and we are developing the Model $SF_6$ GCB for the GIS now. We'll explain the present condition of development of 800kV $SF_6$ GCB until now.

  • PDF

Non-conventional formulations for the finite element method

  • de Freitas, J.A. Teixeira;de Almeida, J.P. Moitinho;Peraira, E.M.B. Ribeiro
    • Structural Engineering and Mechanics
    • /
    • v.4 no.6
    • /
    • pp.655-678
    • /
    • 1996
  • The paper reports on alternative hybrid/mixed formulations being developed by the Structural Analysis Research Group of Institute Superior T$\acute{e}$cnico. These formulations open the scope and increase the power of the finite element method by allowing different fields to be independently approximated, within certain consistency criteria, and by enhancing the use of a wide range of approximation functions. They have been applied to the analysis of 2-D problems, laminar structures and solids, using different constitutive relations, both in quasi-static and dynamic regimes. The fundamental properties of the formulations are identified and assessed and their performance is illustrated using simple, linear applications.

The Study on the application of plasma co-polymerized (MMA-Styrene) thin film as E-beam resist (플라즈마중합법에 의한 (MMA+Styrene) 박막의 E-beam용 레지스트 특성에 대한 연구)

  • Jung, Y.;Park, J.K.;Park, S.K.;Park, J.Y.;Park, S.H.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1183-1185
    • /
    • 1993
  • The plasma polymerized thin film of MMA+Sty was prepared using a capacitively coupled gas-flow-type reactor. This thin films were also delincated by the electron-beam apparatus with an acceleration voltage 30KV, and the pattern in the resist was developed with the gas-flow-type reactor using an argon as an etchant. The effect of discharge power on groth rate and etching rate of the thin film were studied. The molacular structure of the resist was investigated by ESCA and FT-IR.

  • PDF

Measurement of HTS Stacked Tapes Properties under Over-Current Condition in External Magnetic Field (외부자계 인가시 적층 고온초전도선재의 과전류 통전특성 측정)

  • Lee, K.Y.;Lim, H.W.;Lee, H.J.;Cha, G.S.;Lee, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.909-911
    • /
    • 2002
  • Rises of current level at power applications, such as transformer, motor, power cable need for using stacked HTS tapes. In this paper, we measured rises of temperature and tap voltage in 4-stacked HTS tapes under over-current condition. We measured 4-stacked HTS tapes properties under over-current condition with a little temperature rise as well as a large temperature rise. Rises of temperature and tap voltage are measured by using E-type thermocouples and voltage taps, respectively. According to the results of measurement, rises of tap voltage under over-current condition with a large temperature rises depends on rises of temperature.

  • PDF

A Study on Mixed Mode I/II Interlaminar Fracture Toughness of Carbon Fiber Reinforced Plastic Composites (CFRP 복합재료의 혼합모드 I/II 층간파괴인성치에 관한 연구)

  • Kim, H.J.;Park, M.I.;Kim, J.D.;Koh, S.W.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.48-54
    • /
    • 2000
  • This paper describes the effect of molding pressure, specimen geometries for Mixed Mode I/II interlaminar fracture toughness of carbon fiber reinforced plastic composites by using asymmetrical double cantilever beam(ADCB) specimen. The value of $G_{I/IIC}$ as a function of various molding pressure is almost same at 307, 431, 585 kPa. However it shows the highest value under 307 kPa molding pressure. The effect of $G_{I/IIC}$ due to the change of initial crack length of ADCB specimen was almost negligible in this study. It turns out that the condition for mix mode quasi-static crack growth in ADCB specimen is the ratio of the crack length to that of the specimen, i.e., ${\alpha}/L<0.4$.

  • PDF

Optimum Design of Journal Bearings Using Simulated Annealing Method (모사 어닐링법을 이용한 저널 베어링의 최적 설계)

  • Goo, H.E.;Song, J.D.;Lee, S.J.;Yang, B.S.
    • Journal of Power System Engineering
    • /
    • v.8 no.2
    • /
    • pp.45-52
    • /
    • 2004
  • This paper describes the optimum design for journal bearings by using simulated annealing method. Simulated annealing algorithm is an optimization technique to calculate global and local optimum solutions. Dynamic characteristics of the journal bearing are calculated by using finite difference method (FDM), and these values are used for the procedure of journal bearing optimization. The objective is to minimize the resonance response (Q factor) of the simple rotor system supported by the journal bearings. Bearing clearance and length to diameter ratio are used as the design variables.

  • PDF

DC/DC Boost Converter using Coupling Inductor For High Power Fuel Cell Systems (고전력 연료전지 시스템을 위한 커플링 인덕터를 사용한 DC/DC 부스트 컨버터)

  • Kim Y. H.;Kim J. M.;Moon H. W.;Jung E. J.;Won C. Y.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.489-493
    • /
    • 2004
  • 연료전지는 차세대 대체 에너지원으로 부각되고 있다. 그러나 연료전지시스템 특성상 전류의 정격이 큼으로 전류의 리플성분을 감소시킬 필요가 있다. 본 논문에서는 부스트 컨버터 회로에서 인덕터에 흐르는 전류의 리플성분을 줄이기 위한 방법으로 3-channel 감${\cdot}$가극성 커플링 인덕터를 사용한 부스트 컨버터를 제안하였고 이를 일반적인 인덕터, 2-channel 감${\cdot}$가극성 커플링 인덕터를 사용한 컨버터 시스템과 비교 분석하고 시뮬레이션을 통해 시스템의 적합성을 검증하였다. 커플링 인덕터를 사용함으로써 전류 리플 성분이 감소될 뿐 아니라 시스템 효율, 무게, 가격 면에서의 효과도 기대 된다.

  • PDF

Islanding Detection Method of Embedded Generator connected to Power Distribution System (분산형전원이 도입된 배전계통에 대한 ISLANDING DETECTION METHOD)

  • Hwang, J.S.;Kim, J.E.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.522-524
    • /
    • 2000
  • The installation of small sized Embedded Generator(EG) in parallel with the utility supply was required several technical complications for protection of the system. One of the most important protection is to provide protection against islanding and out of synchronism reclosing with the utility source. This paper explains several current methods of detecting 'Loss Of Mains'(LOM). But they have not proved completely dependable, in particular when the islanded load's capacity matches that of the EG. A new loss of mains protection algorithm is presented in this paper which based on measurement of the reactive power and node voltage for detecting the islanding condition even though the EG operate in the capacity.

  • PDF

Analysis of the lightning characteristics by the Lightning DB in KOREA (낙뢰위치표정시스템의 낙뢰 DB를 이용한 한반도 뇌격 특이특성 분석)

  • Woo, J.W.;Kwak, J.S.;Shim, E.B.;Lee, G.W.;Kim, K.W.;Kim, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1658-1660
    • /
    • 2001
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF