• Title/Summary/Keyword: Dynamic operation logic

Search Result 61, Processing Time 0.025 seconds

A Development on the ATC Operation Strategy of the Automated Container Terminal (자동화터미널의 ATC 운영전략 개발)

  • Kim Woo-Sun;Nam Ki-Chan
    • Journal of Navigation and Port Research
    • /
    • v.30 no.3 s.109
    • /
    • pp.235-240
    • /
    • 2006
  • This study analyzed equipment operation strategy of ATC(Automated Transfer Crane) in order to development efficiency ATC operation logic for apply to domestic ACT(Automated Container Terminal). Improving productivity of ACT developed dynamic operation logic and established dispatching rule. As a result of simulation experiment reduced waiting time and interference time of ATC. Thus, we can improve productivity of ACT using dynamic operation logic and interference avoidance strategy.

A Study on Dynamic Characteristics of Directional Control Logic Valve (방향제어 조직밸브의 동특성에 관한 연구)

  • Lee, Il-Yeong;Oh, Se-Kyung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.4
    • /
    • pp.172-179
    • /
    • 1988
  • A cartridge type hydraulic logic valve consists of simple two port valve whose poppet is closed or opened by means of pressure signal of a pilot line. Accordingly, the logic valve can be used not only for direction, flow and pressure control purpose but also for versatile function valve which enables all above mentioned functions. In addition, the valve has little internal leakage and pressure loss, superior response characteristics and easiness in making small block type valve. The above mentioned good performances being recognized recently, the logic valve has been used widely in the large scale hydraulic system such as a hydraulic press system, for the performance requirements of high speed operation and precise control characteristics. However, there are scarce reports until now, except for a few ones from Aachen Institute of Technology in West Germany, so it is necessary to be studied on development and investigation for practical application. This paper showed that the static and dynamic characteristics of a logic valve when the logic valve is used for directional control, to investigate the relations between the valve operating characteristics and the valve design conditions. From the above mentioned procedure, it was ascertained that the valve operation characteristics obtained by numerical analysis showed good agreements with experimental results. The representative results obtained are as follows; 1. During the valve is closing, the poppet velocity is almost constant in the logic valve. 2. The pilot pressure P sub(3) and the resistance R in the pilot line have much influences on the valve operation time. 3. Spring strength have not such a severe influence on the valve operating time. 4. The operation characteristics of the logic valve can be estimated with good accuracy comparatively by numerical analysis with the equations describing poppet motion.

  • PDF

A Study of Single Electron Transistor Logic Characterization Using a SPICE Macro-Modeling (단전자 트랜지스터로 구성된 논리 게이트 특성에 관한 연구)

  • 김경록;김대환;이종덕;박병국
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.111-114
    • /
    • 2000
  • Single Electron Transistor Logic (SETL) can be characterized by HSPICE simulation using a SPICE macro model. First, One unit SET is characterized by Monte-carlo simulation and then we fit SPICE macro-modeling equations to its characteristics. Second, using this unit SET, we simulate the transient characteristics of two-input NAND gate in both the static and dynamic logic schemes. The dynamic logic scheme shows more stable operation in terms of logic-swing and on/off current ratio. Also, there is a merit that we can use the SET only as current on-off switch without considering the voltage gain.

  • PDF

Sub-One volt DC Power Supply Expandable 4-bit Adder/Subtracter System using Adiabatic Dynamic CMOS Logic Circuit Technology

  • Takahashi, Kazukiyo;Yokoyama, Michio;Shouno, Kazuhiro;Mizunuma, Mitsuru
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1543-1546
    • /
    • 2002
  • The expandable 4 bit adder/subtracter IC was designed using the adiabatic and dynamic CMOS logic (ADCL) circuit as the ultra-low power consumption basic logic circuit and the IC was fabricated using a standard 1.2 ${\mu}$ CMOS process. As the result the steady operation of 4 bit addition and subtraction has been confirmed even if the frequency of the sinusoidal supply voltage is higher than 10MHz. Additionally, by the simulation, at the frequency of 10MHz, energy consumption per operation is obtained as 93.67pJ (ar addition and as 118.67pJ for subtraction, respectively. Each energy is about 1110 in comparison with the case in which the conventional CMOS logic circuit is used. A simple and low power oscillation circuit is also proposed as the power supply circuit f3r the ADCL circuit. The oscillator operates with a less one volt of DC supply voltage and around one milli-watts power dissipation.

  • PDF

Design of High-Speed Dynamic CMOS PLA (고속 다이나믹 CMOS PLA의 설계)

  • 김윤홍;임인칠
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.11
    • /
    • pp.859-865
    • /
    • 1991
  • The paper proposes a design of high-speed dynamic CMOS PLA (Programmable Logic Array) which performs stable circuit operation. The race problem which nay occur in a NOR-NOR implementation of PLA is free in the proposed dynamic CMOS PLA by delaying time between the clocks to the AND- and to the OR-planes. The delay element has the same structure as the product line of the longest delay in the AND p`ane. Therefore it is unnecessary to design the delay element or to calculate correct delay time. The correct delay generated by the delay element makes the dynamic CMOS PLA to perform correct and stable circuit operation. Theproposed dynamic CMOS PLA has few variation of switching delay with the increasing number of inputs or outputs in PLA. It is verified by SPICE circuit simulation that the proposed dynamic CMOS PLA has the better performance over existing dynamic CMOS PLA's.

  • PDF

FPSO Cargo Pumping 시스템 가상운전 시스템 개발

  • Nam, Ki-Il;Han, Ki-Hun;Chang, Kwang-Pil;Oh, Tae-Young;Chang, Dae-Jun;Song, Seok-Ryong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.251-252
    • /
    • 2006
  • This study developed the virtual operation system for the hydraulic pump system for marine usage. The scope of this study is to develop a process dynamic simulation model for the hydraulic pump system for marine usage, to investigate the process dynamic characteristics using the models, to accomplish the logic diagram for the PLC control and to achieve a human-machine interface (HMI) for the convenience of operators to monitor and control the process. The virtual operation system provides a virtual operation environment for the pumping system, enabling the operators to simulate the change of process variables. The system will assist in developing advanced control logics and then optimal design of the system.

  • PDF

Fuzzy Expert PID Control of Magnetic Bearing System (자기베어링 시스템의 퍼지 전문가 PID 제어)

  • Gyeong, Jin-Ho;Kim, Yu-Il;Kim, Jong-Seon;Lee, Hae
    • 연구논문집
    • /
    • s.23
    • /
    • pp.73-80
    • /
    • 1993
  • This study presents an intelligent PID control method based on the fuzzy logic and this method is applied to the active magnetic bearing system. By using an appropriate fuzzy matrix, some changes of values of the three coefficients of the controller are determined during system operation and these lead to the improvement of the transient and steady state behavior of the closed loop system. The presented method is actually a combination of the principles of PID control and fuzzy logic. Since the fuzzy logic using linguistic variables in place of numeric variables has many points of likeness to the human logic, the improvement in performance is notable especially in case of large nonlinearity and uncertainty such as the controller start and the excessive mass unbalance. A set of simulation and experimental results illustrate and considerable improvement in the control performance including small overshoot and small transient currents in magnet coils, while maintaining the overal static and dynamic characteristics near the equilibrium position.

  • PDF

Boiler Supply Water Temperature Setting by Outside Air Temperature and Return Water Temperature (외기온도와 환수온도를 이용한 보일러의 공급수온도설정)

  • Han, Do-Young;Yoo, Byeong-Kang
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.161-166
    • /
    • 2009
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a boiler unit, the effective operation is necessary. In this study, the supply water temperature algorithm of a condensing gas boiler was developed. This includes the setpoint algorithm and the control algorithm of the supply water temperature. The setpoint algorithm was developed by the fuzzy logic and the control algorithm was developed by the proportional integral algorithm. In order to analyse the performance of the supply water temperature algorithm, the dynamic model of a condensing gas boiler system was used. Simulation results showed that the supply water temperature algorithm developed for this study may be practically applied for the control of the condensing gas boiler.

  • PDF

Multi-bit Sigma-Delta Modulator for Low Distortion and High-Speed Operation

  • Kim, Yi-Gyeong;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • v.29 no.6
    • /
    • pp.835-837
    • /
    • 2007
  • A multi-bit sigma-delta modulator architecture is described for low-distortion performance and a high-speed operation. The proposed architecture uses both a delayed code and a delayed differential code of analog-to-digital converter in the feedback path, thereby suppressing signal components in the integrators and relaxing the timing requirement of the analog-to-digital converter and the scrambler logic. Implemented by a 0.13 ${\mu}m$ CMOS process, the sigma-delta modulator achieves high linearity. The measured spurious-free dynamic range is 89.1 dB for -6 dBFS input signal.

  • PDF

Energy management strategies of a fuel cell/battery hybrid system using fuzzy logics (퍼지 논리를 이용한 연료전지/축전지 하이브리드 시스템의 운전제어)

  • Jeong, Kwi-Seong;Lee, Won-Yong;Kim, Chang-Soo
    • Journal of Hydrogen and New Energy
    • /
    • v.15 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Hybrid power systems with fuel cells and batteries have the potential to improve the operation efficiency and dynamic response. A proper load management strategy is important to better system efficiency and endurance in hybrid systems. In this paper, a fuzzy logic algorithm has been used to determine the fuel cell output power depending on the external required power and the battery state of charge(SoC). If the required power of the hybrid system is small and the SoC is small, then the greater part of the fuel cell power is used to charge the battery pack. If the required power is relatively big and the SoC is big, then fuel cell and battery are concurrently used to supply the required power. These IF-THEN operation rules are implemented by fuzzy logic for the energy management system of hybrid system. The strategy is evaluated by simulation. The results show that fuzzy logic can be effectively used to optimize the operational efficiency of hybrid system and to maintain the battery SoC properly.