Measurement of Imaging Property of Flat-Panel Detector

  • Matsumoto, Masao;Suekane, Kouji;Maeda, Kouji;Ogata, Yuji;Inamura, Kiyonari;Kanai, Kouzo;Kanamori, Hitoshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.385-388
    • /
    • 2002
  • We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curves, Modulation Transfer Function (MTF), Wiener spectra (WS), Noise Equivalent Quanta (NEQ) and Detective Quantum Efficiency (DQE)) for the direct type and indirect type of Flat-Panel Detector (FPD). First, the digital and overall characteristic curves of the both types of FPD had more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of the direct-type FPD were superior to those of the indirect-type FPD. Third, for identical exposures, the digital and overall WS of the direct-type FPD were similar or worse than those of the indirect-type FPD, and for larger exposure, the digital WS of the both types of FPD were smaller, but overall WS of the both types of FPD were larger. Fourth, the digital and overall NEQ and DQE of the direct-type FPD were worse than both NEQ and DQE of the indirect-type FPD at lower spatial frequencies, but were better at higher spatial frequencies.

  • PDF

An Experimental Study on the Cause of Signal Inhomogeneity for Magnetic Resonance Angiography Using Phantom Model of Anterior Communicating(A-com) Artery (전교통동맥 모형을 이용한 자기공명혈관촬영술의 신호 불균일에 관한 실험적 연구)

  • Yoo, Beong-Gyu;Chung, Tae-Sub
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • Aneurysm-mimicking findings were frequently visualized due to hemodynamical causes of dephasing effects around area of A-com artery during magnetic resonance angiography(MRA) and these kind of phenomena have not been clearly known yet. We investigated the hemodynamical patterns of dephasing effect around area of the A-com artery that might be a cause of false intracranial aneurysms on MRA. For experimental study, We used hand-made silicon phantoms of the asymmetric A-com artery as like a bifurcation configuration. In a closed circulatory system with UHDC computer driven cardiac pump system. MRA and fast digital subfraction angiography(DSA) involved the use of these phantoms. Flow patterns were evaluated with axial and coronal imaging of MRA(2D-TOF, 3D-TOF) and DSA of Phantoms constructed from an automated closed-type circulatory system filled with glycerol solution [circulation fluid(glycerol:water = 1:1.4)]. These findings were then compared with those obtained from computational fluid dynamic(CFD) for inter-experimental correlation study. Imaging findings of MRA, DSA and CFD on inflow zone according to the following: a) MRA demonstrated high signal intensity zone as inflow zone on silicon phantom; b) Patterns of DSA were well matched with MRA on trajectory of inflow zone; and c) CFD were well matched with MRA on the pattern of main flow. Imaging findings of MRA. DSA and CFD on turbulent flow zone according to the following: a) MRA demonstrated hyposignal intensity zone at shoulder and axillar zone of main inflow; b) DSA delineated prominent vortex flow at the same area. The hemodynamical causes of signal defect, which could Induce the false aneurysm on MRA, turned out to be dephasing effects at axilla area of bifurcation from turbulent flow as the results of MRA, DSA and CFD.

  • PDF

The Difference of the Changes of Images on Ultrasound Scanner Setting Parameters

  • Kang, Hae-Kyung;Kim, Youn-Min;Kim, Hyun-Soo;Lee, Sung-Hee;Cho, Se-Youn;Lyu, Young-Eun;Jung, In-A
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.81-87
    • /
    • 2010
  • The setting parameters of ultrasound scanner give influences to change of image. Sonographers have used a Matlab program to make Low Contrast Sensitivity(LCS) value and compared original images in order to evaluate the use of the supersonic diagnosis machinery. We confirmed the change of image in Grayscale values using Photoshop program. Experiment equipment of our research used A Medison Accuvix V10, A Multi-Tissue Ultrasound Phantom(040 GSE) of CHRIS Company, A Adobe Photoshop CS4 Program, A Convex Probe, A USB memory stick, A Probe Fixation Equipment. The method used Gain, Dynamic Range(DR) of the setting parameters of ultrasound scanner and researched Gain and DR was set to 10 dB. We changed the different settings to see the changes of images using Grayscale values of a Photoshop program about tissue images of a phantom. This study evaluated DR and Gain whether it is an image controller to get the optimum contrast to produce an image to see the how effect on the images. We did not use Gateway in supersonic diagnosis machinery. We can easily open to open the files through Photoshop program before we get Digital Imaging and Communications in Medicine(DICOM) files use USB memory stick in supersonic diagnosis machinery. When we diagnosed the lesion of the patient with ultrasound, the contrast and the Gray scale value of image are very important. In this research, we determined the optimum setting parameters that provided useful information to diagnose disease and evaluated the change of improved images.

  • PDF

Simple Camera-based Evaluation System for Lower Limb Alignment during Pedalling (자전거 페달링 시 하지 정렬 평가를 위한 영상 시스템 개발)

  • Oh, Ho-Sang;Choi, Jin-Seung;Kang, Dong-Won;Seo, Jeong-Woo;Bae, Jae-Hyuk;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.123-129
    • /
    • 2012
  • Simple camera-based system for evaluation of lower limb alignment as a part of an automated cycling fitting system was developed and verified in this study. Developed imaging system can evaluate lower limb alignment quantitatively during pedaling using a general camcorder and single marker attached on the knee. Threshold-based marker detection algorithm was proposed in this study. Experiment was carried out to compare the trajectory data from marker detection algorithm of the developed imaging system with the trajectory data from 3-D motion capture system. Results showed that average error between trajectories was 2.33 mm (0.92 %) in the vertical direction and 0.62 mm (1.86 %) in the medio-lateral direction. There existed significant correlation between two measured values (r=0.9996 in the vertical direction and r=0.9975 in the medio-lateral direction). It can be concluded that developed imaging system be applied to evaluate lower limb alignment which is an important factor for dynamic bicycle fitting.

Coherent X-ray Diffraction Imaging with Single-pulse Table-top Soft X-ray Laser

  • Kang, Hyon-Chol;Kim, H.T.;Lee, S.K.;Kim, C.M.;Choi, I.W.;Yu, T.J.;Sung, J.H.;Hafz, N.;Jeong, T.M.;Kang, S.W.;Jin, Y.Y.;Noh, Y.C.;Ko, D.K.;Kim, S.S.;Marathe, S.;Kim, S.N.;Kim, C.;Noh, D.Y.;Lee, J.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.02a
    • /
    • pp.429-430
    • /
    • 2008
  • We demonstrate coherent x-ray diffraction imaging using table-top x-ray laser at a wavelength of 13.9nm driven by 10-Hz ti:Sapphire laser system at the Advanced Photonics Research Institute in Korea. Since the flux of x-ray photons reaches as high as $10^9$ photons/pulse in a $20{\times}20{\mu}m^2$ field of view, we measured a ingle-pulse diffraction pattern of a micrometer-scale object with high dynamic range of diffraction intensities and successfully reconstructed to the image using phase retrieval algorithm with an oversampling ratio of 1:6. the imaging resolution is $^{\sim}150$ nm, while that is much improved by stacking the many diffraction patterns. This demonstration can be extended to the biological sample with the diffraction limited resolution.

  • PDF

Development of Hand-held OCT probe for Ophthalmic Imaging (안구 영상을 위한 OCT용 손잡이 형 프로브의 개발)

  • Cho, Nam-Hyun;Jung, Woong-Gyu;Jung, Un-Sang;Sephen, A.Boppart;Shim, Jae-Hoon;Kim, Jee-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.1
    • /
    • pp.24-30
    • /
    • 2011
  • We have developed a hand-held probe for an ophthalmic OCT system. The hand-held probe for imaging was designed to be compact and portable. The cornea and retinal images were acquired by replacing the objective lens at the front of the probe. To verify the performance of the hand-held OCT probe, we acquired two dimensional OCT image of the rat eye in vivo and reconstructed three dimensional rat eye rendering images. In vivo 3D OCT images were showed distinct structural information in the posterior and anterior chamber with minimal motion artifacts. Thereby, OCT imaging speed is suitable for an dynamic in vivo experiment.

Physical principles of digital radiographic imaging system (디지털 방사선영상 시스템의 기본적 원리)

  • Choi, Jin-Woo;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

Comparison of Positron Emission Tomography(PET) imaging-based initial in vivo pharmacokinetics by administration routes of [18F]FDG

  • Yiseul Choi;Jang Woo Park;Eun Sang Lee;Ok-Sun Kim;Hye Kyung Chung
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.99-103
    • /
    • 2021
  • In this study, the initial in vivo pharmacokinetic changes according to the routes of drug administration were investigated using bioimaging techniques. The purpose of this study was to quantify the degree of distribution of each major organ in normal mice over time by acquiring Positron Emission Tomography/Computed Tomography images while administering routes F-18 fluorodeoxyglucose such as intravenous, intraperitoneal and per oral, a representative diagnostic radiopharmaceutical. Dynamic Positron Emission Tomography images were acquired for 90 minutes after drug administration. Radioactivity uptake was calculated for major organs using the PMOD program. In the case of intravenous administration, it was confirmed that it spread quickly and evenly to major organs. Compared to intravenous administration, intraperitoneal administration was about three times more absorbed and distributed in the liver and intestine, and it was showed that the amount excreted through the bladder was more than twice. In the case of oral administration, most stayed in the stomach, and it was showed that it spread slowly throughout the body. In comparison with intravenous administration, it was presented that the distribution of kidneys was more than 9 times and the distribution of bladder was 66% lower. Since there is a difference in the initial in vivo distribution and excretion of each administration method, we confirmed that the determination of the administration route is important for in vivo imaging evaluation of new drug candidates.

Left Atrial Velocity Vector Imaging Can Assess Early Diastolic Dysfunction in Left Ventricular Hypertrophy and Hypertrophic Cardiomyopathy

  • Se-Jung Yoon;Sungha Park;Eui-Young Choi;Hye-Sun Seo;Chi Young Shim;Chul Min Ahn;Sung-Ai Kim;Jong-Won Ha
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.1
    • /
    • pp.41-48
    • /
    • 2023
  • BACKGROUND: The function of left atrium (LA) is difficult to assess because of its ventricle-dependent, dynamic movement. The aim of this study was to assess LA function using velocity vector imaging (VVI) and compare LA function in patients with hypertrophic cardiomyopathy (HCMP) and left ventricular hypertrophy (LVH) with normal controls. METHODS: Fourteen patients with HCMP (72% male, mean age of 52.6 ± 9.8), 15 hypertensive patients with LVH (88% male, mean age of 54.0 ± 15.3), and 10 age-matched controls (83% male, mean age of 50.0 ± 4.6) were prospectively studied. Echocardiographic images of the LA were analyzed with VVI, and strain rate (SR) was compared among the 3 groups. RESULTS: The e' velocity (7.7 ± 1.1; 5.1 ± 0.8; 4.5 ± 1.3 cm/sec, p = 0.013), E/e' (6.8 ± 1.6; 12.4 ± 3.3; 14.7 ± 4.2, p = 0.035), and late diastolic SR at mid LA (-1.65 ± 0.51; -0.97 ± 0.55; -0.82 ± 0.32, p = 0.002) were significantly different among the groups (normal; LVH; HCMP, respectively). The e' velocity, E/e', and late diastolic SR at mid LA were significantly different between normal and LVH (p = 0.001; 0.022; 0.018), whereas LA size was similar between normal and LVH (p = 0.592). The mean late diastolic peak SR of mid LA was significantly correlated with indices of diastolic function (E/e', e', and LA size). CONCLUSIONS: The SR is a useful tool for detailed evaluation of LA function, especially early dysfunction of LA in groups with normal LA size.

Characteristics of Vibration Response Imaging in Healthy Koreans

  • Choi, Kyu-Hee;Kim, Kwan-Il;Bang, Ji-Hyun;Kim, Jae-Hwan;Choi, Jun-Yong;Jung, Sung-Ki;Jung, Hee-Jae
    • The Journal of Korean Medicine
    • /
    • v.32 no.6
    • /
    • pp.10-17
    • /
    • 2011
  • Background: Vibration response imaging (VRI) is a new technology that records energy generated by airflow during the respiration cycle. Analysis of lung sound using VRI may overcome the limitations of auscultation. Objectives: To set a VRI standard for healthy Koreans, we conducted a clinical assessment to evaluate breath sound images and quantification in healthy subjects and compared the findings with reported breath sound characteristics. Methods: Recordings were performed using the VRIxp. Eighty subjects took a deep breath four times during a 12-second interval while sitting upright. The quantitative aspect was analyzed using the VRI quantitative lung data (QLD) for total left lung, total right lung and for six lung regions: left upper lung (LUL), left middle lung (LML), left lower lung (LLL), right upper lung (RUL), right middle lung (RML), right lower lung (RLL). The qualitative aspect was provided through image assessments by three reviewers. Results: In all regions the left lung had significantly higher QLD than the right lung (P<0.005, paired t-test). The inter-rater agreement was 0.78. 84% of the images were found normal by the final assessment. Among the 16% (n=13) of images with abnormal final assessment, the most common flawed features were dynamic image (77%, n=10) and maximum energy frame (MEF) shape (77%, n=10). No significant differences were found between males and females for QLD but there were significant differences in qualitative aspects including dynamic images, MEF shape, and missing LLL. Conclusion: The characteristics of healthy Koreans are similar to those of Western subjects reported previously. VRI is easy to use and objective, and so is helpful to diagnose patients with respiratory diseases and to monitor the progress of diseases after medical treatments.