• Title/Summary/Keyword: Dynamic grid

Search Result 585, Processing Time 0.023 seconds

Simulations of the Dynamic Load in a Francis Runner based on measurements of Grid Frequency Variations

  • Ellingsen, Rakel;Storli, Pal-Tore
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.2
    • /
    • pp.102-112
    • /
    • 2015
  • In the Nordic grid, a trend observed the recent years is the increase in grid frequency variations, which means the frequency is outside the normal range (49.9-50.1 Hz) more often. Variations in the grid frequency leads to changes in the speed of rotation of all the turbines connected to the grid, since the speed of rotation is closely related to the grid frequency for synchronous generators. When the speed of rotation changes, this implies that the net torque acting on the rotating masses are changed, and the material of the turbine runners must withstand these changes in torque. Frequency variations thus leads to torque oscillations in the turbine, which become dynamical loads that the runner must be able to withstand. Several new Francis runners have recently experienced cracks in the runner blades due to fatigue, obviously due to the runner design not taking into account the actual loads on the runner. In this paper, the torque oscillations and dynamic loads due to the variations in grid frequency are simulated in a 1D MATLAB program, and measured grid frequency is used as input to the simulation program. The maximum increase and decrease in the grid frequency over a 440 seconds interval have been investigated, in addition to an extreme event where the frequency decreased far below the normal range within a few seconds. The dynamic loading originating from grid frequency variations is qualitatively found by a constructed variable $T_{stress}$, and for the simulations presented here the variations in $T_{stress}$ are found to be around 3 % of the mean value, which is a relatively small dynamic load. The important thing to remember is that these dynamic loads come in addition to all other dynamic loads, like rotor-stator interaction and draft tube surges, and should be included in the design process, if not found to be negligible.

Dynamic reliability of structures: the example of multi-grid composite walls

  • Liu, Pei;Yaoa, Qian-Feng
    • Structural Engineering and Mechanics
    • /
    • v.36 no.4
    • /
    • pp.463-479
    • /
    • 2010
  • Based on damage accumulation of multi-grid composite walls, a method of dynamic reliability estimations is proposed. The multi-grid composite wall is composed of edge frame beam, edge frame columns, grid beams, grid columns and filling blocks. The equations including stiffness, shear forces at filling blocks cracking and multi-grid composite walls yielding, ultimate displacement, and damage index are obtained through tests of 13 multi-grid composite wall specimens. Employing these equations in reliability calculations, procedures of dynamic reliability estimations based on damage accumulation of multi-grid composite walls subjected to random earthquake excitations are proposed. Finally the proposed method is applied to the typical composite wall specimen subjected to random earthquake excitations which can be specified by a finite number of input random variables. The dynamic reliability estimates, when filling blocks crack under earthquakes corresponding to 63% exceedance in 50 years and when the composite wall reach limit state under earthquakes corresponding to 2-3% exceedance in 50 years, are obtained using the proposed method by taking damage indexes as thresholds. The results from the proposed method which show good agreement with those from Monte-Carlo simulations demonstrate the proposed method is effective.

An Efficient Job Scheduling Strategy for Computational Grid (계산 그리드를 위한 효율적인 작업 스케줄링 정책)

  • Jo, Ji-Hun;Lee, Won-Joo;Jeon, Chang-Ho
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.8
    • /
    • pp.753-757
    • /
    • 2008
  • In this paper, we propose a new scheduling strategy for dynamic programming in Grid environment. The key idea of this scheme is to reduce the execution time of a job by dividing the dynamic table based on the locality of table and allocating jobs to nodes which minimize network latency. This scheme obtains optimal concurrency by constructing the dynamic table using a distributed top down method. Through simulation, we show that the proposed Grid strategy improves the performance of Grid environment compared to previous branch-bound strategies.

Dynamic Distributed Grid Scheme to Manage the Location-Information of Moving Objects in Spatial Networks (공간 네트워크에서 이동객체의 위치정보 관리를 위한 동적 분산 그리드 기법)

  • Kim, Young-Chang;Hong, Seung-Tae;Jo, Kyung-Jin;Chang, Jae-Woo
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.12
    • /
    • pp.948-952
    • /
    • 2009
  • Recently, a new distributed grid scheme, called DS-GRID(distributed S-GRID), has been proposed to manage the location information of moving objects in a spatial network[1]. However, because DS-GRID uses uniform grid cells, it cannot handle skewed data which frequently occur in the real application. To solve this problem, we propose a dynamic distributed grid scheme which splits a grid cell dynamically based on the density of moving objects. In addition, we propose a k-nearest neighbor processing algorithm for the proposed scheme. Finally, it is shown from the performance analysis that our scheme achieves better retrieval and update performance than the DS-GRID when the moving objects are skewed.

A Study on the Stability of Micro-Grid System Considering Operating Range of Micro-Sources (Micro-Source의 운전 범위에 따른 Micro-Grid 시스템 의 안정도에 관한 연구)

  • Son, Kwang M.;Lee, Kye B.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.841-847
    • /
    • 2007
  • This paper deals with the micro-grid consisting of micro-sources which adopt voltage sourced inverters with independent real and reactive power control capability for providing premium power quality. This paper presents dynamic modeling and the stable operating range of the micro-grid system varying the parameters of the micro-sources. The fundamental frequency model of the micro-source inverters are considered to form a dynamic model of the micro-grid system. Stability analysis is performed based on the linearized dynamic model of the micro-grid system. Case study results show the parameters affecting the stability of the micro-grid and the stable operating range of the micro-sources.

A Source Code Cross-site Scripting Vulnerability Detection Method

  • Mu Chen;Lu Chen;Zhipeng Shao;Zaojian Dai;Nige Li;Xingjie Huang;Qian Dang;Xinjian Zhao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.6
    • /
    • pp.1689-1705
    • /
    • 2023
  • To deal with the potential XSS vulnerabilities in the source code of the power communication network, an XSS vulnerability detection method combining the static analysis method with the dynamic testing method is proposed. The static analysis method aims to analyze the structure and content of the source code. We construct a set of feature expressions to match malignant content and set a "variable conversion" method to analyze the data flow of the code that implements interactive functions. The static analysis method explores the vulnerabilities existing in the source code structure and code content. Dynamic testing aims to simulate network attacks to reflect whether there are vulnerabilities in web pages. We construct many attack vectors and implemented the test in the Selenium tool. Due to the combination of the two analysis methods, XSS vulnerability discovery research could be conducted from two aspects: "white-box testing" and "black-box testing". Tests show that this method can effectively detect XSS vulnerabilities in the source code of the power communication network.

A Study on the Stability of Micro-Grid System (마이크로그리드 시스템의 안정도에 관한 기초 연구)

  • Son, Kwong-Myoung;Lee, Kye-Byung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.46-53
    • /
    • 2007
  • Micro-grid consists of micro-sources which adopt environmentally friendly and reliable power sources such as Fuel-Cell and Micro-Turbines with independent real and reactive power control capability for providing premium power quality. This paper deals with the basic aspect of dynamic modeling and the stability analysis of the micro-grid system. The fundamental frequency model of the micro-source inverters are considered to form a dynamic model of the micro-grid system Stability analysis is performed based on the linearized dynamic model of the micro-grid system Case study results show the parameters affecting the stability of the micro-grid.

Evaluation of Turbulent Flame Speed Model for Turbulent Premixed Combustion Flow around Bluff Body (보염기 주위의 난류 예혼합 연소에 관한 난류화염 속도 모델의 평가)

  • Park, Nam-Seob;Ko, Sang-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.82-88
    • /
    • 2011
  • The objective of this study is to investigate the validity of the dynamic sub-grid G-equation model to a complex turbulent premixed combustion such as bluff body stabilized turbulent premixed flames for the considering of the realistic engineering application. In this study, a new turbulent flame speed model, introduced by the sub-grid turbulent diffusivity and the flame thickness, is also proposed and is compared with an usual model using sub-grid turbulent intensity and with the experimental data. The calculated results can predict the velocity and temperature of the combustion flow in good agreement with the experiment data.

Event Detection on Motion Activities Using a Dynamic Grid

  • Preechasuk, Jitdumrong;Piamsa-nga, Punpiti
    • Journal of Information Processing Systems
    • /
    • v.11 no.4
    • /
    • pp.538-555
    • /
    • 2015
  • Event detection based on using features from a static grid can give poor results from the viewpoint of two main aspects: the position of the camera and the position of the event that is occurring in the scene. The former causes problems when training and test events are at different distances from the camera to the actual position of the event. The latter can be a source of problems when training events take place in any position in the scene, and the test events take place in a position different from the training events. Both issues degrade the accuracy of the static grid method. Therefore, this work proposes a method called a dynamic grid for event detection, which can tackle both aspects of the problem. In our experiment, we used the dynamic grid method to detect four types of event patterns: implosion, explosion, two-way, and one-way using a Multimedia Analysis and Discovery (MAD) pedestrian dataset. The experimental results show that the proposed method can detect the four types of event patterns with high accuracy. Additionally, the performance of the proposed method is better than the static grid method and the proposed method achieves higher accuracy than the previous method regarding the aforementioned aspects.

Large Eddy Simulation of Turbulent Premixed Combustion Flow around Bluff Body based on the G-equation with Dynamic sub-grid model (Dynamic Sub-grid 모델을 이용한 G 방정식에 의한 보염기 주위의 난류 예혼합 연소에 관한 대 와동 모사)

  • Park, Nam-Seob;Ko, Sang-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.8
    • /
    • pp.1084-1093
    • /
    • 2010
  • Large eddy simulation of turbulent premixed flame stabilized by the bluff body is performed by using sub-grid scale combustion model based on the G-equation describing the flame front propagation. The basic idea of LES modeling is to evaluate the filtered-front speed, which should be enhanced in the grid scale by the scale fluctuations. The dynamic subgrid scale models newly introduced into the G-equation are validated by the premixed combustion flow behind the triangle flame holder. The calculated results can predict the velocity and temperature of the combustion flow in good agreement with the experiment data.