Dynamic Response of Reinforced Concrete Beams Following Instantaneous Removal of a Bearing Column

  • Tian, Ying;Su, Youpo
    • International Journal of Concrete Structures and Materials
    • /
    • v.5 no.1
    • /
    • pp.19-28
    • /
    • 2011
  • This paper documents an experimental study of dynamic response of reinforced concrete beams following instantaneous removal of a bearing column. Four half-scale specimens representing two-span beam bridging across the removed column were tested. The test boundary conditions simulated rotational and longitudinal restraints imposed on a frame beam by the neighboring structural components. The gravity loads were simulated by attaching mass blocks on the beams at three locations. Dynamic loading effects due to sudden removal of a column were simulated by quickly releasing the supporting force at the middle of the specimens. The experimental study investigated the load-carrying capacity of beams restrained longitudinally at the boundaries and dynamic impact on forces. The tests confirmed the extra flexural strength provided by compressive arch action under dynamic loading. The tests also indicated that the dynamic amplification effects on forces were much lower than that assumed in the current design guideline for progressive collapse.

Strategic width-wise arrangement of viscous dampers in steel buildings under strong earthquakes

  • Huang, Xiameng
    • Earthquakes and Structures
    • /
    • v.20 no.2
    • /
    • pp.225-238
    • /
    • 2021
  • Supplemental passive dampers are widely employed to improve the structural performance of buildings under seismic excitations. Nevertheless, the added damping could be counter-productive if the axial forces induced by the damper reaction forces are not routed properly in the columns. A few researchers engaged to optimize the width-wise damper arrangement to improve the delivered path of the axial column forces. However, most of these studies are limited under the design-based seismic level and few of them has evaluated the collapse performance of buildings under strong earthquakes. In this paper, the strategic width-wise placement method of viscous dampers is explored regarding the building performance under collapse state. Two realistic steel buildings with different storeys are modelled and compared to explore higher mode effects. Each building is designed with four different damper arrangement scenarios based on a classic damper distribution method. Both a far-fault and a near-fault seismic environment are considered for the buildings. Incremental Dynamic Analysis (IDA) is performed to evaluate the probability of collapse and the plastic mechanism of the retrofitted steel buildings.

Dynamic Crush Energy Absorption Characteristics of the Laminated Composite Box Tubes (섬유강화 복합재료 Box Tube의 동적 충격에너지 흡수거동)

  • Kang, S.C.;Jun, W.J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.3
    • /
    • pp.118-126
    • /
    • 1993
  • Static and dynamic crushing behaviors of composite box tube show the difference with those of metal tube. This paper investigates the characteristics of static and dynamic crushing test which were conducted to characterize the energy absorption and collapse mode of composite box tubes. Sixteen kinds of tube specimens were fabricated from[0/90] woven Glass/Epoxy fabric and autoclave cured. Axial crushing tests were performed using Instron and Dynatup Impact Tester. It is shown that collapse mode and energy absorption capacity can vary according to the aspect ratio, length, loading rate, lay-up direction of fabric, and trigger geometry of the composite box tube.

  • PDF

Seismic Fragility Assessment of Ordinary RC Shear Walls Designed with a Nonlinear Dynamic Analysis (비선형 동적해석에 의해 내진설계된 철근콘크리트 보통 전단벽의 지진취약도 분석)

  • Jeon, Seong-Ha;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.169-181
    • /
    • 2019
  • Seismic performance of ordinary reinforced concrete shear wall systems commonly used in high-rise residential buildings is evaluated. Three types of shear walls exceeding 60m in height are designed by performance-based seismic design. Then, incremental dynamic analysis is performed collapse probability is assessed in accordance with the procedure of FEMA P695. As a result, story drift, plastic rotation, and compressive strain are observed to be major failure modes, but shear failure occur little. Collapse probability and collapse margin ratio of performance groups do not meet requirement of FEMA P695. It is observed that critical wall elements fail due to excessive compressive strain. Therefore, the compressive strain of concrete at the boundary area of the shear wall needs to be evaluated with more conservative acceptance criteria.

Structural identification and seismic performance of brick chimneys, Tokoname, Japan

  • Aoki, T.;Sabia, D.
    • Structural Engineering and Mechanics
    • /
    • v.21 no.5
    • /
    • pp.553-570
    • /
    • 2005
  • Dynamic and static analyses of existing structures are very important to obtain reliable information relating to actual structural properties. For this purpose a series of material test, dynamic test and static collapse test of the existing two brick chimneys, in Tokoname, are carried out. From the material tests, Young's modulus and compressive strength of the brick used for these chimneys are estimated to be 3200 MPa and 7.5 MPa, respectively. The results of static collapse test of the existing two brick chimneys are discussed in this paper and composed with the results from FEA (Finite Element analysis). From the results of dynamic tests, the fundamental frequencies of Howa and Iwata brick chimneys are estimated to be about 2.69 Hz and 2.93 Hz, respectively. Their natural modes are identified by ARMAV (Autoregressive Moving Average Vectors) model. On the basis of the static and dynamic experimental tests, a numerical model has been prepared. According to the European code (Eurocode n. 8: "Design of structures for earthquake resistance") non-linear static (Pushover) analysis of the two chimneys is carried out and they seem to be vulnerable to earthquakes with 0.25 to 0.35 g.

Dynamic Increase factor based on residual strength to assess progressive collapse

  • Mashhadi, Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • v.25 no.5
    • /
    • pp.617-624
    • /
    • 2017
  • In this study, a new empirical method is presented to obtain Dynamic Increase Factor (DIF) in nonlinear static analysis of structures against sudden removal of a gravity load-bearing element. In this method, DIF is defined as a function of minimum ratio of difference between maximum moment capacity ($M_u$) and moment demand ($M_d$) to plastic moment capacity ($M_p$) under unamplified gravity loads of elements. This function determines the residual strength of a damaged building before amplified gravity loads. For each column removal location, a nonlinear dynamic analysis and a step-by-step nonlinear static analysis are carried out and the modified empirical DIF formulas are derived, which correspond to the ratio min $[(M_u-M_d)/M_p]$ of beams in the bays immediately adjacent to the removed column, and at all floors above it. Therefore, the new DIF can be used with nonlinear static analysis instead of nonlinear dynamic analysis to assess the progressive collapse potential of a moment frame structure. The proposed DIF formulas can estimate the real residual strength of a structure based on critical member.

New Equivalent Static Analysis Method of Dynamic Behavior during Progressive Collapse (연쇄붕괴의 동적거동을 고려한 새로운 등가정적해석 기법)

  • Kim, Chee-Kyeong;Lee, Jae-Cheol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.3
    • /
    • pp.239-246
    • /
    • 2007
  • In this paper a new equivalent static analysis method of dynamic behavior during progressive collapse is presented. The proposed analysis method uses the equivalent nodal load for the element stiffness which represents the dynamic behavior influence caused by the deletion of elements during progressive collapse analysis. The proposed analysis method improves the efficiency of progressive collapse analysis haying the iterative characteristic because the inverse of the structural stiffness matrix is roused in the reanalysis. By comparing the results obtained by this analysis method with those of GSA code analysis and time history analysis, it is shown that the results obtained by this analysis method more closely approach to those of time history analysis than by GSA code analysis.

Dynamic Instability Behavior of Diagonally Braced Steel Frames under Seismic Excitation (지진하중을 받는 대각선 철골 중심가새골조의 동적 불안정 거동)

  • Lee, Cheol-Ho;Kim, Jung-Jae
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.129-136
    • /
    • 2005
  • Concentrically braced steel frames are considered as being quite prone to soft-story response due to the degradation in brace compressive resistance after buckling under severe ground motions. When combined with the system P-Delta effects, collapse of the concentrically braced frames by dynamic instability becomes a highly probable. In this study, a new, relatively simple dynamic instability coefficient was proposed for diagonally braced steel frames by considering the strength degradation of the brace after buckling. Nonlinear dynamic analysis was conducted to check the robustness of the proposed index based on simulated ground motions. The analysis results showed that the dynamic instability index proposed predicts the collapse potential more consistently than the conventional one. Dynamic instability was triggered when the index value was close to 0.7.

  • PDF

Collapse assessment and seismic performance factors in tall tube-in-tube diagrid buildings

  • Khatami, Alireza;Heshmati, Mahdi;Aghakouchak, Ali Akbar
    • Earthquakes and Structures
    • /
    • v.19 no.3
    • /
    • pp.197-214
    • /
    • 2020
  • Diagrid structures have been introduced as a fairly modern lateral load-resisting system in the design of high-rise buildings. In this paper, a novel diagrid system called tube-in-tube diagrid building is introduced and assessed through pushover and incremental dynamic analyses. The main objectives of this paper are to find the optimum angle of interior and exterior diagrid tube and evaluate the efficiency of diagrid core on the probability of collapse comparing to the conventional diagrid system. Finally, the seismic performance factors of the proposed system are validated according to the FEMA P695 methodology. To achieve these, 36-story diagrid buildings with various external and internal diagonal angles are designed and then 3-D nonlinear models of these structures developed in PERFORM-3D. The results show that weight of steel material highly depends on diagonal angle of exterior tube. Adding diagrid core generally increases the over-strength factor and collapse margin ratio of tall diagrid buildings confirming high seismic safety margin for tube-in-tube diagrid buildings under severe excitations. Collapse probabilities of both structural systems under MCE records are less than 10%. Finally, response modification factor of 3.0 and over-strength factor of 2.0 and 2.5 are proposed for design of typical diagrid and tube-in-tube diagrid buildings, respectively.

Collapse-Resisting Capacity of Steel Moment Frames Using the Linear Elastic Analysis (선형해석방법을 이용한 철골 모멘트골조의 붕괴저항성능)

  • Kim, Jin-Koo;Yang, Jeong-Ho;Kim, Tae-Wan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.4
    • /
    • pp.435-442
    • /
    • 2007
  • Since the Ronan Point apartment collapsed in 1968, researches on the progressive collapse have been intermittently conducted, and the collapse of the World Trade Center twin towers made the researches active again. In the United States guidelines such as GSA (2003) and DoD (2005) were provided for design and analysis of building structures against the progressive collapse. In this study the progressive collapse-resisting capacity of steel moment resisting frames designed by KBC-2005 was investigated using linear elastic static analysis and linear dynamic analysis procedures suggested in the guidelines. The results showed that in accordance with the GSA guideline the moment frame designed only for gravity load turned out to be vulnerable to the progressive collapse, whereas the lateral load resisting frame designed for earthquake load satisfied the criteria for progressive collapse. However both systems sailed to satisfy the criteria of the DoD-2005 guideline.