• Title/Summary/Keyword: Dynamic Brain CT

Search Result 7, Processing Time 0.024 seconds

CT Scan Findings of Rabbit Brain Infection Model and Changes in Hounsfield Unit of Arterial Blood after Injecting Contrast Medium (토끼 뇌감염 모델의 CT 소견과 조영제 주입 후 동맥혈의 Hounsfield Unit의 변화)

  • Ha, Bon-Chul;Kwak, Byung-Kook;Jung, Ji-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.270-279
    • /
    • 2012
  • This paper explores CT findings of a rabbit brain infection model injected with Escherichia coli and investigates the changes in Hounsfield unit (HU) of arterial blood over time. The brain infection model was produced by injecting E. coli $1{\times}10^7$ CFU/ml, 0.1 ml through the burr hole in the calvarium; 2~3 mm in depth from the dura mater, and contrast-enhanced CT, dynamic CT and arterial blood CT images were gained. It was found that various brain infections such as brain abscess, ventriculitis and meningitis. The CT image of brain abscess showed a typical pattern which the peripheral area was strongly contrast-enhanced while the center was weakly contrast-enhanced. The CT image of ventriculitis showed a strong contrast-enhancement along the lateral ventricle wall, and the CT image of meningitis showed a strong contrast-enhancement in the area between the telencephalon and the diencephalon. In dynamic CT images, the HU value of the infection core before injecting contrast medium was $31.01{\pm}3.55$. By 10 minutes after the injection, the value increased gradually to $40.36{\pm}3.76$. The HU value in the areas of the marginal rim where was hyper-enhanced showed $47.23{\pm}3.12$ before contrast injection, and it increased to $63.59{\pm}3.31$ about 45 seconds after the injection. In addition, the HU value of the normal brain tissue opposite to the E. coli. injected brain was $39.01{\pm}3.24$ before the injection, but after the contrast injection, the value increased to $49.01{\pm}4.29$ in about 30 seconds, and then it showed a gradual decline. In the arterial blood CT, the HU value before the contrast injection was $87.78{\pm}6.88$, and it increased dramatically between 10 to 30 seconds until it reached a maximum value of $749.13{\pm}98.48$. Then it fell sharply to $467.85{\pm}62.98$ between 30 seconds to 45 seconds and reached a plateau by 60 seconds. Later, the value showed a steady decrease and indicated $188.28{\pm}25.03$ at 20 minutes. Through this experiment, it was demonstrated that the brain infection model can be produced by injecting E. coli., and the characteristic of the infection model can be well observed with contrast-enhanced CT scan. The dynamic CT scan showed that the center of the infection was gradually contrast-enhanced, whereases the peripheral area was rapidly contrast-enhanced and then slowly decreased. As for arterial blood, it increased significantly between 10 seconds to 30 seconds after the contrast medium injection and decreased gradually after reaching a plateau.

Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study (급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구)

  • Park, Ha-Young;Pyeon, Do-Yeong;Kim, Da-Hye;Jung, Young-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.543-547
    • /
    • 2016
  • Acute stroke is a one of common disease that require fast diagnosis and treatment to save patients life. however, the acute stroke may cause lifelong disability due to brain damage with no prompt surgical procedure. In order to diagnose the Stroke, brain perfusion CT examination and possible rapid implementation of 3D angiography has been widely used. However, a low-dose technique should be applied for the examination since a lot of radiation exposure to the patient may cause secondary damage for the patients. Therefore, the degradation of the measured CT images may interferes with a clinical check in that blood vessel shapes on the CT image are significantly affected by gaussian noise. In this study, we employed the spatio-temporal technique to analyze dynamic (brain perfusion) CT data to improve an image quality for successful clinical diagnosis. As a results, proposed technique could remove gaussian noise successfully, demonstrated a possibility of new image segmentation technique for CT angiography. Qualitative evaluation was conducted by skilled radiological technologists, indicated significant quality improvement of dynamic CT images. the proposed technique will be useful tools as a clinical application for brain perfusion CT examination.

Radiation dose and Lifetime Attributable Risk of Cancer Estimates in 64-slice Multidetector Computed Tomography (64-절편 다행검출 CT 검사에서의 환자선량과 암 발생의 Lifetime Attributable Risk(LAR) 평가)

  • Kang, Yeong-Han;Park, Jong-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.244-252
    • /
    • 2011
  • This study was to estimate the radiation dose associated with 64-slice multidetector CT(MDCT) in clinical practice and quantify the potential cancer risk associated with these examinations. Lifetime attributable risks(LAR) were estimated with models developed in the national Academies' Biological Effects of Ionizing Radiation VII report. Mean effective dose were 1.48mSv in Brain axial scan, 7.66mSv in chest routine contrast, 12.17mSv in coronary angiogram, 24.52mSv in Dynamic abdomen scan. LAR estimates for brain routine varied from 1 in 7463 for man to 1 in 4926 for women. In chest routine with contrast, LAR varied from 1 in 1449 for men to 1 in 952. LAR of Abdomen dynamic CT varied from 1 in 453 for men to 1 in 298 for women. So, 64-slice MDCT scan is associated with non-negligible LAR of cancer. Doses can be reduced by careful attention to scanning protocol.

The Evaluation of Dynamic Continuous Mode in Brain SPECT (Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가)

  • Park, Sun Myung;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.15-22
    • /
    • 2017
  • Purpose During Brain SPECT study, critical factor for proper study with $^{99m}Tc-ECD$ or $^{99m}Tc-HMPAO$ is one of the important causes to patent's movement. It causes both improper diagnosis and examination failure. In this study, we evaluated the effect of Dynamic Continuous Mode Acquisition compared to Step and Shoot Mode to raise efficacy and reject the data set with movement, as well as, be reconstructed in certain criteria. Materials and Methods Deluxe Jaszczak phantom and Hoffman 3D Brain phantom were used to find proper standard data set and exact time. Step and Shoot Mode and Dynamic Continuous Mode Acquisition were performed with SymbiaT16. Firstly, Deluxe Jaszczak phantom was filled with $Na^{99m}TcO_4$ 370 MBq and obtained in 60 minutes to check spatial resolution compared with Step and Shoot Mode and Dynamic Continuous Mode. The second, the Hoffman 3D Phantom filled with $Na^{99m}TcO_4$ 74 MBq was acquired for 15 Frame/minutes to evaluate visual assessment and quantification. Finally, in the Deluxe Jaszczak phantom, Spheres and Rods were measured by MI Apps program as well as, checking counts with the frontal lobe, temporal lobe, occipital lobe, cerebellum and hypothalamus parts was performed in the Hoffman 3D Brain Phantom. Results In Brain SPECT Study, using Dynamic Continuous Mode rather than current Step and Shoot Mode, we can do the reading using the 20 to 50 % of the acquired image, and during the test if the patient moves, we can remove unneeded image to reduce the rate of restudy and reinjection. Conclusion Dynamic Continuous Mode in Brain study condition enhances effects compared to Step and Shoot Mode. And also is powerful method to reduce reacquisition rate caused by patient movement. The findings further indicate that it suggest rejection limit to maintain clinical value with certain reconstruction factors compared with Tomo data set. Further examination to improve spatial resolution, SPECT/CT should be the answer for that.

  • PDF

A Study on the Optimum Amount of Contrast Media in Brain Angiography (뇌 혈관검사 시 적정 조영제량에 관한 연구)

  • Kim, Gyoo-Hyung;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.123-128
    • /
    • 2018
  • Recently, the use of contrast agents has been increasing as a broader range of tests and dynamic tests have become common due to the development of equipment and imaging techniques such as Multi-Detector CT. However, the side effects of using contrast agents have been reduced by the development of non-ionic contrast agents, but they are still occurring often. The purpose of this study was to propose a method to minimize the side effect of contrast agent by using the amount of contrast agent injected to the brain angiography test to suppress excessive use of contrast agent and analyze the amount of contrast agent. Patients who were prescribed Brain Angiography due to cerebrovascular disease, According to the results of the comparison of the results obtained by dividing into 4 groups of 10ml each according to the amount of contrast medium injected with contrast agent according to the BMI of the patient, BA and SNR were not different between groups, and even if the amount of contrast injection was reduced, there was no problem in the evaluation of CT angiography through 3D reconstruction. This result shows that even if the contrast medium is injected into the blood vessels of the patient first and then the contrast medium is used as the physiological saline solution, the contrast medium is reduced by 40% it can be expected to minimize.

Evaluation about Distribution of 18F-DOPA at Striatum by Using Dynamic Study (Dynamic study를 이용한 선조체에서의 18F-DOPA의 분포에 대한 평가)

  • Kim, Jae Il;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.67-71
    • /
    • 2015
  • Purpose At recently, we enter into the aging society and a age-related disease is increasing. Among that, prevalence of degenerative brain disease like Parkin's disease will be increased. So, many radiopharmaceuticals is developed to diagnosis early and to evaluate the performance of therapeutic drugs. Especially $^{18}F-DOPA$ which involved at dopamine synthesis and function of storage is widely used to the diagnosis of Parkinson's disease as well as brain tumors. in the study, we will evaluate the distribution pattern of $^{18}F-DOPA$ at the striatum by using dynamic study. Materials and Methods We used Biograph Truepoint(Siemens, Germany) as PET/CT scanner, injected a $^{18}F-DOPA$ ($600{\pm}30MBq$) to patient (4men, 6women. $67{\pm}11age$) who visited our hospital from June to September, started 95min dynamic study at same time. after finishing acquisition, we reconstructed PET data with 19 frame every 5 minutes, analysed a average counts at ROI's where set at both striatums, anterior putamen, posterior putamen Results Counts in the cerebellum as the background formed a plateau after 90 minutes from the highest out rapidly reduced to 15 minutes. Counts of anterior putamen and posterior gradually increased but formed a plateau after 60min. A count ratio of Striatum to cerebellum was continuously increased up to more than 95 minutes, A count ratios of an anterior putamen to posterior one formed a plateau after 85 minutes. Conclusion The dynamic acquisition can be possible to evaluate a distribution of the $^{18}F-DOPA$ in the striatum and the VOI analysis through a dynamic acquisition and a variety of patterns. Futhermore, to make a uniformed distribution and count ratio of striatum to cerebellum, a static acquisition will have to start 90minutes later after injection.

  • PDF

Dynamic Changes in the Bridging Collaterals of the Basal Ganglia Circuitry Control Stress-Related Behaviors in Mice

  • Lee, Young;Han, Na-Eun;Kim, Wonju;Kim, Jae Gon;Lee, In Bum;Choi, Su Jeong;Chun, Heejung;Seo, Misun;Lee, C. Justin;Koh, Hae-Young;Kim, Joung-Hun;Baik, Ja-Hyun;Bear, Mark F.;Choi, Se-Young;Yoon, Bong-June
    • Molecules and Cells
    • /
    • v.43 no.4
    • /
    • pp.360-372
    • /
    • 2020
  • The basal ganglia network has been implicated in the control of adaptive behavior, possibly by integrating motor learning and motivational processes. Both positive and negative reinforcement appear to shape our behavioral adaptation by modulating the function of the basal ganglia. Here, we examined a transgenic mouse line (G2CT) in which synaptic transmissions onto the medium spiny neurons (MSNs) of the basal ganglia are depressed. We found that the level of collaterals from direct pathway MSNs in the external segment of the globus pallidus (GPe) ('bridging collaterals') was decreased in these mice, and this was accompanied by behavioral inhibition under stress. Furthermore, additional manipulations that could further decrease or restore the level of the bridging collaterals resulted in an increase in behavioral inhibition or active behavior in the G2CT mice, respectively. Collectively, our data indicate that the striatum of the basal ganglia network integrates negative emotions and controls appropriate coping responses in which the bridging collateral connections in the GPe play a critical regulatory role.