• Title/Summary/Keyword: Duty Factor

Search Result 363, Processing Time 0.031 seconds

A Study on the Output Voltage and Efficiency of the Single-Phase Z-Source Inverters According to Duty Ratio (듀티 비에 따른 단상 Z-소스 인버터의 효율과 출력 전압에 관한 연구)

  • Hong, Seung-Pyo;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.8-19
    • /
    • 2011
  • This paper was compared for the output voltage and efficiency of the single-phase Z-source inverter(ZSI) according to shoot through duty ratio D. The eight single-phase ZSI in this study are typical ZSI, Embedded ZSI(EZSI), Improved ZSI(IZSI), Quasi ZSI(QZSI), Series ZSI, Trans ZSI(TSI), Switched inductor ZSI(SL-ZSI) and Extended boost ZSI (exZSI). The eight ZSI are divided into two Groups. ; Group-1 which is ZSI with the ordinary voltage boost factor B, and Group-2 which is ZSI with the maximum voltage boost factor B. For the execution of the proposed study, the PSIM simulation was achieved under the condition of input DC voltage=150[V] of ZSI, load =30[${\Omega}$] and 60[Hz] output filter. The output voltage and efficiency of each ZSI were calculated within the limits of D=0.1~0.4. As a result, the output peak voltage of Group-2 was suddenly increased in a specified duty ratio D, and its efficiency was rapidly decreased. On the contrary, Group-1 shown the output and efficiency characteristics without sudden change compared to Group-2 despite the duty ratio increase. The efficiency of the Group-2 was sharply declined at duty ratio D of the most output voltage, but, in case of Group-1, the efficiency was slightly declined. Finally, the input DC current of ZSI with DCM and CCM was discussed.

EXPERIMENTAL STUDY ON THE HEAVY-DUTY GAS TURBINE COMBUSTOR (산업용 가스터빈 연소기에 대한 실험적 연구)

  • Antonovsky, V.;Ahn, Kook-Young
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.142-149
    • /
    • 2000
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed in the scale 1:1. The model experiments were executed at a pressure smaller than in the real gas turbine. The combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure, and NOx emission were measured at partial and full load for both model and on-site testing. The comparison of these items of information, received on similar modes in the stand and field tests, has allowed the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

Model and Field Testing of a Heavy-Duty Gas Turbine Combustor

  • Ahn, Kook-Young;Kim, Han-Seok;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.9
    • /
    • pp.1319-1327
    • /
    • 2001
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed 1:1 scale. The model experiments were executed at a lower pressure than that in a real gas turbine. Combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure and NOx emission were measured at partial and full loads for both model and on-site testing. The comparison of these items in the stand and field test results led to has the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

Boosting Inductor Distribution Type PWM Rectifier (승압인덕턴스 분산형 PWM 정류기)

  • Lee, Moo-Young;Kim, Woo-Hyun;Ma, Jin-Suck;Im, Sung-Un;Kwon, Woo-Hyen
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1940-1943
    • /
    • 1998
  • A new PWM rectifier which offers a unity power factor is proposed. The circuit has same inductance as the conventional boosting type PWM rectifier in powering mode, but the inductance is splitted to 2 part in freewheeling mode. So the period of freewheeling mode is shorter than that of conventional boosting type PWM rectifier, and discontinuous input current is obtained in wide duty range. Therefore the proposed PWM rectifier accomplishs a unity power factor in wide range of duty ratio and boosting factor. And the conventional boosting type PWM rectifier has poor power factor near the unity boosting ratio, the proposed PWM rectifier improves this problem. The mathmatical analysis are presented and experimental results are given.

  • PDF

A Novel PCCM Voltage-Fed Single-Stage Power Factor Correction Full-Bridge Battery Charger

  • Zhang, Taizhi;Lu, Zhipeng;Qian, Qinsong;Sun, Weifeng;Lu, Shengli
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.872-882
    • /
    • 2016
  • A novel pseudo-continuous conduction mode (PCCM) voltage-fed single-stage power factor correction (PFC) full-bridge battery charger is proposed in this paper. By connecting a freewheeling transistor in parallel with an input inductor, the PFC cell can operate in the PCCM with a constant duty ratio. Thus, the dc/dc stage can be designed using this constant duty ratio and the restriction on the duty ratio of the PFC cell is eliminated. As a result, the input current distortion is less and the dc bus voltage becomes controllable over the wide output power range of the battery charger. Moreover, the operation principle of the dc/dc stage is designed to be similar to that of a conventional phase-shifted full-bridge converter. Therefore, it is easy to implement. In this paper, the operation of the new converter is explained, and the design considerations of the controller and key parameters are presented. Simulation and experimental results obtained from a 1 kW prototype are given to confirm the operation of the proposed converter.

LED Dimming Control Using Manchester-Code Duty Factor And Spike Detection in Visible Light Communication (가시광통신에서 맨체스터코드 듀티율과 스파이크 검출을 이용한 LED 조명제어)

  • Lee, Seong-Ho
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.571-579
    • /
    • 2019
  • Visible light communication (VLC) performs illumination and communication simultaneously, thus it is important to prevent the flicker due to the optical power variation during data transmission and at the same time to have dimming control capability. In this paper, we used Manchester code for flicker-prevention and dimming control. In the transmitter, the duty factor of the Manchester code was used for controlling the LED illumination. In the receiver, the edge-spike signals of an RC-high pass filter were used for recovering the Manchester code while preventing the adjacent noise light. In experiments, the LED light was kept flicker-free and the average optical power was controlled in the range of 8~68 % of the continuous wave (CW) LED light by changing the duty factor of the Manchester code.

Antecedents of Duty Free Shop Willingness to Pay

  • Song, Myungkeun;Moon, Joonho;Tang, Ruo-Han
    • Asia-Pacific Journal of Business
    • /
    • v.12 no.1
    • /
    • pp.87-100
    • /
    • 2021
  • Purpose - This study aims to examine the antecedents of willingness to pay in the domain of duty free shop. Design/methodology/approach - This study chooses willingness to pay as explained variable. The candidates of explanatory variables are price fairness, brand awareness, employee service, product diversity, and crowding. This study uses survey to explore the linear relation between variables. This research collected data using online panel data collection service. The number of valid observation is 265. The research targe is Lotte duty free store. Statistical analysis was for statistical inference. To attain the information of survey respondents, frequency analysis is employed. Next, this study implemented exploratory factor analysis and reliability to ensure both validity and reliability of measurement items. This study executed multiple regression analysis to test research hypotheses Findings - Regrading results, brand awareness, employee service, and product diversity are positively associated with willingness to pay of duty free shop product. Moreover, the results of regression analysis suggest the inverted-U shape association between crowding and willingness to pay. However, price fairness appeared as non-significant variable to account for willingness to pay in the multiple regression analysis. Originality - This study contributes to the literature by examining duty free shop customers more.

A Study on the job satisfaction of diner out company employee (외식산업 종사원의 직무 만족도에 관한 연구(서울시내 패밀리 레스토랑을 중심으로 연구))

  • 이재진
    • Culinary science and hospitality research
    • /
    • v.6 no.2
    • /
    • pp.79-95
    • /
    • 2000
  • In the modern industrial society, the management of human resources is regarded as an area as much important as the management itself. The development of human capacity is required to accomplish upgrading human resources quality. The objective of this study aims to seek the way to solve the problem of the job satisfaction of diner out company employee. The collecting data is analyzed by sass which is one of the computer. programs. This empirical research result shows some facts as follows : First, Significant differences between male and female in regard to job satisfaction were found. Second, No significant differences between unmarried and married in regard to job satisfaction were found. Third, Significant differences were found in the accomplishment and communication factor of job satisfaction according to the age, Fourth, Significant differences were found in the hard work environment and accomplishment factor of job satisfaction according to the education Fifth, Significant differences were found in the hard work environment factor of job satisfaction according to the major. Sixth, Significant differences were found in the wages, accomplishment , communication factor of job satisfaction according to the position. Seventh, Significant differences were found in the accomplishment and affinity factor of job satisfaction according to the period of the job. Eighth, Significant differences were found in the duty trait factor of jobs satisfaction according to the level of the pay. Ninth, Significant differences were found in the duty trait factor of job satisfaction according to the kind of the job. Tenth, Significant differences were found in job satisfaction according to the kind of diner out company.

  • PDF

Novel Direct Duty-Ratio Modulation Method for Matrix Converter

  • Li, Yulong;Choi, Nam-Sup;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.16-18
    • /
    • 2008
  • A novel general direct duty ratio pulse width modulation strategy is proposed to modulate matrix converters. By using average concept over one switching period, the modulation algorithm and the required equations are derived to synthesize the desired output voltage and to achieve the controlled input power factor. The proposed method use continuous carrier and the predetermined duty ratio signal for directly generating gating signals an thus is named "direct duty ratio PWM(DDPWM)". The feasibility and validity of the proposed strategy are verified by experimental results.

  • PDF

A Simple Grid-Voltage-Sensorless Control Scheme for PFC Boost Converters

  • Nguyen, Cong-Long;Lee, Hong-Hee;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.712-721
    • /
    • 2014
  • This paper introduces a simple grid-voltage-sensorless control scheme for single-phase power factor correction (PFC) boost converters. The grid voltage waveform is obtained based on the dc output voltage, the switching duty ratio, and a phase-lead compensator. In addition, the duty ratio feedback is utilized to obtain the unity input power factor and the zero harmonic current. The proposed control scheme is designed and mathematically analyzed based on a small-signal model of PFC boost converters. To verify the effectiveness of the proposed control scheme, several simulations and experiments are carried out in two applications: an industrial power system with a 60 Hz grid frequency and a commercial aircraft application with a 400 Hz grid frequency.