Comparative Study of Exposure Assessment of Dust in Building Materials Enterprises Using ART and Monte Carlo

  • Wei Jiang;Zonghao Wu;Mengqi Zhang;Haoguang Zhang
    • Safety and Health at Work
    • /
    • 제15권1호
    • /
    • pp.33-41
    • /
    • 2024
  • Background: Dust generated during the processing of building materials enterprises can pose a serious health risk. The study aimed to compare and analyze the results of ART and the Monte Carlo model for the dust exposure assessment in building materials enterprises, to derive the application scope of the two models. Methods: First, ART and the Monte Carlo model were used to assess the exposure to dust in each of the 15 building materials enterprises. Then, a comparative analysis of the exposure assessment results was conducted. Finally, the model factors were analyzed using correlation analysis and the scope of application of the models was determined. Results: The results show that ART is mainly influenced by four factors, namely, localized controls, segregation, dispersion, surface contamination, and fugitive emissions, and applies to scenarios where the workplace information of the building materials enterprises is specific and the average dust concentration is greater than or equal to 1.5 mg/m3. The Monte Carlo model is mainly influenced by the dust concentration in the workplace of building materials enterprises and is suitable for scenarios where the dust concentration in the workplace of the building materials enterprises is relatively uniform and the average dust concentration is less than or equal to 6mg/m3. Conclusion: ART is most accurate when workplace information is specific and average dust concentration is > 1.5 mg/m3; whereas, The Monte Carlo model is the best when dust concentration is homogeneous and average dust concentration is < 6 mg/m3.

CKD 혼합에 따른 Recycled Material의 회복탄성계수와 일축압축강도 특성 (Characteristic of Resilient Modulus and Unconfined Compressive Strength for Recycled Materials blend with Cement Kiln Dust)

  • 손영환
    • 한국농공학회논문집
    • /
    • 제52권2호
    • /
    • pp.19-25
    • /
    • 2010
  • This study was conducted to determine the resilient modulus (Mr) and the unconfined compressive strength (UCS) of two recycled roadway materials such as recycled pavement material (RPM) and road surface gravel (RSG) with or without cement kiln dust (CKD). The recycled materials were blended with two CKD contents (5, 10 %) and 28 day curing time. Mr and UCS tests were also conducted after 10cycles of freezing and thawing to asses the impact of freeze-thaw cycling. Mr was determined conducting by the laboratory test method described by NCHRP 1-28A. Stabilized RPM and RSG had a modulus and a strength higher than unstabilized RPM and RSG. Mr and UCS of RPM and RSG mixed with CKD increased with increasing CKD content. The results indicated that the addition of CKD could be improved the strength and the stiffness of RPM and RSG. Therefore, RPM, RSG and CKD could be used as an effective materials in the reconstruction of roads.

태풍 우사기와 나리 통과 후 부산지역 미세먼지 농도의 급상승에 관한 연구 (Sudden rise of fine particle concentration after Typhoon USAGI and NARI passage in Busan)

  • 전병일
    • 환경영향평가
    • /
    • 제20권4호
    • /
    • pp.557-564
    • /
    • 2011
  • This study was conducted to investigate the sudden rise of fine particle concentration after the passage of typhoon USAGI and NARI in Busan. Nocturnal inversion layer was formed at atmospheric boundary layer and wind direction changed from southerly wind to northeasterly wind after USAGI passed through Busan. Fine particle concentration in Busan rapidly increased by subsidence of air pollutants released from sources and dust transported from in the vicinity of industrial regions. Wind direction changed from northeasterly wind to southeasterly wind, wind velocity increased and lower atmosphere became extremely unstable after NARI passed through Busan. $PM_{10}$ concentration of Busan increased sharply because of surface dust dispersed by strong wind. Fine particle concentration generally decreases by precipitation and wind after typhoon passes through. However, the concentration can also go up not only by subsidence and transportation in nocturnal inversion layer but also by surface dust which temporarily occurs by strong wind.

황산알루미늄수화물에 의한 비산방지 효과 평가 (Assessment of Anti-Scattering Effect by Aluminium Sulfate)

  • 이병대
    • 한국응용과학기술학회지
    • /
    • 제27권4호
    • /
    • pp.470-474
    • /
    • 2010
  • Various anti-scattering agents for suppression of dust scattering at waste depository were compared in this study. Based on the price, easy of usage, and no toxicity, 1% of $Al_2(SO_4)_3$ was selected as surface hardening agents. Only lower than 2% of total weight were flied when wind speed was monthly maximum velocity during 1 hr. These results were quite good with comparison of S anti-scattering agents which was made by C company in Korea. When $Al_2(SO_4)_3$ was spread, the surface waste became hard therefore the effect of suppression of scattering dust was long lasting. It was recommend that 2% of $Al_2(SO_4)_3$ was spread to keep suppression of scattering dust when sudden gust of wind such as natural disaster was occurred.

외부 오염 환경하에서 고분자 절연재료의 표면 누설전류 측정 및 열화 패턴 분석 (Deterioration Pattern Analysis and Surface Leakage Current of Electrical Insulation in External Pollution)

  • 김영석;송길목;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2080-2081
    • /
    • 2007
  • In this paper, the polymer insulators which had been used for electrical insulation were investigated surface leakage current and deterioration pattern. Because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. The leakage current brings out electrical fault after all. Also, it is need to variation of material and shape to repress a leakage current on electrical material. In this paper, we measured a leakage current on electrical material of facilities by dust, and in experiments the prevention to electrical fault was studied.

  • PDF

Near-infrared polarimetric study of near-Earth object 252P/LINEAR: An implication of scattered light from the evolved dust particles

  • Kwon, Yuna G.;Ishiguro, Masateru;Kwon, Jungmi;Kuroda, Daisuke;Im, Myungshin;Choi, Changsu;Tamura, Motohide;Nagayama, Takahiro;Kawai, Nobuyuki;Watanabe, Jun-Ichi
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.44.2-44.2
    • /
    • 2019
  • Comets, one of the least-altered leftovers from the nascent solar system, have probably preserved the primitive structure inside, whereas their surfaces become modified from the initial states after repetitive orbital revolutions around the Sun. Resurfacing makes the surface drier and more consolidated than the bulk nuclei, creating inert refractory dust layer ("dust mantle"). Near-infrared (NIR; 1.25-2.25 m) polarimetry is theoretically expected to maximize contrast of the porosity between inner fresh and evolved dust particles, by harboring more dust constituents in the single wavelength than the optical; thus, intensifies electromagnetic interaction in dust aggregates. Despite such an advantage, only a few studies have been made in this approach mainly due to the limited accessibility of available facilities. Herein, we present our new multi-band NIR polarimetric study of near-Earth object 252P/LINEAR over 12 days near perihelion, together with the results of optical (0.48-0.80m) imaging observations and backward dynamical simulation of the comet. Based on the results, we will characterize the dust properties of the comet and discuss the possible environmental (temperature and UV radiation) effects that could produce the observed phenomena.

  • PDF

Distribution Characteristics of Dust and Heavy Metals in the Atmosphere Around the Steel Industrial Complex

  • Hye-jin Jo;Jong-Ho Kim;Byung-Hyun Shon
    • International Journal of Advanced Culture Technology
    • /
    • 제12권2호
    • /
    • pp.334-344
    • /
    • 2024
  • In Dangjin, Chungcheongnam-do, there are not only power plants and large steel complexes, but also small and medium-sized air pollutant emission facilities. The dust generated by these facilities has a very small particle size and a large surface area due to condensation and physical and chemical reactions, and is discharged containing various harmful substances. Therefore, this study analyzed the distribution of particulate matter and heavy metal concentrations by particle size in the vicinity of the steel complex, residential area, and reference point using an eight-stage Cascade Impactor. Overall, the direct impact sites with a short distance from the steel complex had the highest concentration, followed by the indirect impact sites, and the non-impact sites had the lowest concentration, indicating that they are directly affected by the steel complex. The atmospheric dust concentration distribution showed a bimodal distribution with a minimum value around the 1.1 to 2.1 ㎛ particle diameter. However, during the yellow dust event, the maximum concentration was biased toward coarse particles. The proportion of PM2.5 in the dust tended to be higher in winter, while the ratio between PM2.5 and PM10 was relatively higher in spring. Regardless of the location of the impact point, heavy metals in the dust were dominated by iron and aluminum, followed by zinc, lead, and manganese.

Health Risks Assessment in Children for Phthalate Exposure Associated with Childcare Facilities and Indoor Playgrounds

  • Kim, Ho-Hyun;Yang, Ji-Yeon;Kim, Sun-Duk;Yang, Su-Hee;Lee, Chung-Soo;Shin, Dong-Chun;Lim, Young-Wook
    • Environmental Analysis Health and Toxicology
    • /
    • 제26권
    • /
    • pp.8.1-8.9
    • /
    • 2011
  • Objectives: This study assessed the health risks for children exposed to phthalate through several pathways including house dust, surface wipes and hand wipes in child facilities and indoor playgrounds. Methods: The indoor samples were collected from various children's facilities (40 playrooms, 42 daycare centers, 44 kindergartens, and 42 indoor-playgrounds) in both summer (Jul-Sep, 2007) and winter (Jan-Feb, 2008). Hazard index (HI) was estimated for the non-carcinogens and the examined phthalates were diethylhexyl phthalate (DEHP), diethyl phthalate (DEP), dibutyl-n-butyl phthalate (DnBP), and butylbenzyl phthalate (BBzP). The present study examined these four kinds of samples, i.e., indoor dust, surface wipes of product and hand wipes. Results: Among the phthalates, the detection rates of DEHP were 98% in dust samples, 100% in surface wipe samples, and 95% in hand wipe samples. In this study, phthalate levels obtained from floor dust, product surface and children's hand wipe samples were similar to or slightly less compared to previous studies. The $50^{th}$ and $95^{th}$ percentile value of child-sensitive materials did not exceed 1 (HI) for all subjects in all facilities. Conclusions: For DEHP, DnBP and BBzP their detection rates through multi-routes were high and their risk based on health risk assessment was also observed to be acceptable. This study suggested that ingestion and dermal exposure could be the most important pathway of phthalates besides digestion through food.

The Improvement of Infrared Brightness Temperature Difference Method for Detecting Yellow Sand Dust

  • Ha, Jong-Sung;Kim, Jae-Hwan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.149-152
    • /
    • 2007
  • The detection of yellow sand dust using satellite has been utilized from various bands from ultraviolet to infrared channels. Among them, Infrared channels have an advantage of detecting aerosols over high reflecting surface as well as during nighttime. Especially, brightness temperature difference between 11 and 12{\mu}m(BTD) was often used to distinguish between water cloud and yellow sand, because Ice and liquid water particles preferentially absorb longer wavelengths while aerosol particles preferentially absorb shorter wavelengths. We have found that the BTD significantly depends on surface temperature, emissivity, and zenith angle and thereby the threshold of BTD. In order to overcome these problems, we have constructed the background brightness temperature threshold of BTD and then subtracted it from BTD. Along with this, we utilized high temporal coverage of geostationary satellite, MTSAT-1R, to verify the reliability of the retrieved signal in conjunction with forecasted wind information. The statistical score test illustrated that this newly developed algorithm showed a promising result for detecting mineral dust by reducing the errors in the current BTD method.

  • PDF

암분 매립 농경지 토양의 표면 침투 및 삼투 특성 (Infiltration and Percolation Characteristics of Water in Agricultural Land Filled with Rock-Dust)

  • Hur, S.O.;Jeon, S.H.;Lee, Y.J.;Han, K.H.;Jo, H.R.;Kang, S.S.;Kim, M.S.;Ha, S.G.;Kim, J.G.
    • 한국토양비료학회지
    • /
    • 제42권Spc호
    • /
    • pp.40-44
    • /
    • 2009
  • 이 연구는 Rock-dust로 채워진 농업 용지(Technosol)의 환경에서 물이 보이는 침투성과 삼투성의 특정을 파악하고자 수행되었다. 이 실험은 A와 B 두 장소에서 이루어졌으며 피실험지의 토양층은 각각 4가지 층으로 분류되었다. 모든 토양층의 토성은 미사질 양토로 분석되었으며 장소 A의 가장 낮은 층에서만은 양질사토였다. 두 토양에서, 각 토양층에 대한 용적밀도는 $1.49g{\cdot}cm^{-3}$을 대체로 상회하였으며, 이는 통상적인 medium textured mineral soil의 $1.25g{\cdot}cm^{-3}$을 크게 웃도는 값이다. 경운 직후 측정된 장소 A의 표토는 이보다 낮았다. 두 토양 표면에서의 $P_2O_5$의 집적은 각각 1962 (A), 1613 (B)$mg{\cdot}kg^{-1}$이었다. 이러한 집적은 3.2~6.5번에 걸쳐서 $300{\sim}500mg{\cdot}kg^{-1}$만큼 작물 생장에 알맞은 규모로 이루어졌다. 두 토양 표변에서의 Infiltration rate는 3.54 (A), 2.85 (B)$cm{\cdot}hr^{-1}$이었으나 각 토양층에 대한 percolation rate는 0.3 이하 (A), 0.003 이하 (B)$cm{\cdot}hr^{-1}$였다. 이러한 결과들은 표토가 동의 작용을 받은 반면 심토는 암분의 농업용지 형성 과정에서 생겨난 구조적인 문제인 바위 부스러기의 응집과 농업기계에 대한 다짐현상으로 인한 것임을 의미한다고 여겨진다.