• Title/Summary/Keyword: Dust monitor

Search Result 65, Processing Time 0.031 seconds

Elemental Analysis of herbal medicine, Foundry Air and Hair for the Study of Human Surroundings (인체 환경 연구를 위한 한약재, 작업장 공기 및 모발의 원소분석)

  • 강상훈;이상순;조승연;정용삼
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.3
    • /
    • pp.64-71
    • /
    • 2002
  • Hair provides important information about the body's mineral status. Therefore, we have studied the trace elemental distribution in human hair under different inhalation and ingestion environment using neutron activation analysis (NAA). NAA is a powerful analytical method which can be used successfully to determine trace elements in environmental and biological materials. Total diet and six different herbal medicine were analysed to study ingestion environment. Airborne dust in foundry was analysed and compared with outdoor dust to study inhalation environment. Human hairs of common person, herbal medicine taker and foundry worker were analysed to estimate the trace elemental distribution of people under different inhalation and ingestion environment. Analytical results show that herbal medicines contain higher micronutrients such as Ca, Mg, Mn and Cu that total diet and airborne dust in foundry has high Cr. The concentration of Ca, Mg and Mn in hair of herbal medicine taker is two times higher than in hair of common person and Cr con-centration in hair of foundry worker is about three times higher than in hair of common person. These results show that NAA can be used importantly to monitor human health through biological and environmental samples.

Development of Wearable Device for Monitoring Working Environment in Pig House (양돈장 작업환경 모니터링을 위한 웨어러블 장비개발)

  • Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.71-81
    • /
    • 2020
  • Enclosed pig house are creating an environment with high concentrations of gas and dust. Poor conditions in pig farms reduce pig weight and increase disease and accidents for livestock workers. In the pig house, the high concentration of harmful gas may cause asphyxiation accidents to workers and chronic respiratory disease by long-term exposure. As pig farm workers have been aging and feminized, the damage to the health of the harsh environment is getting serious, and real-time monitoring is needed to prevent the damage. However, most of the measuring devices related to humidity, harmful gas, and fine dust except temperature sensors are exposed to high concentrations of gas and dust inside pig house and are difficult to withstand for a long time. The purpose of this study is to develop an wearable based device to monitor the hazardous environment exposed to workers working in pig farms. Based on the field monitoring and previous researches, the measurement range and basic specifications of the equipment were selected, and wearable based device was designed in terms of utilization, economic efficiency, size and communication performance. Selected H2S and NH3 sensors showed the average error of 5.3% comparing to standard gas concentrations. The measured data can be used to manage the working environment according to the worker's location and to obtain basic data for work safety warning.

Characterization of Annual PM2.5 and PM10 Concentrations by Real-time Measurements in Cheonan, Chungnam (실시간 측정을 통한 천안시 대기 중 연간 PM2.5, PM10 농도 특성 조사)

  • Heo, Jung-Hyuk;Oh, Se-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.445-450
    • /
    • 2012
  • From 2015, PM2.5 standards will be added to Korean national ambient air quality standards. To characterize PM2.5 levels in Cheonan, annual PM2.5 concentrations along with PM10 concentrations were investigated between February 2010 and January 2011 using a dust monitor. The annual PM2.5 concentration was $40.45{\mu}g/m^3$ and over the standards($25{\mu}g/m^3$). The daily average PM2.5 concentrations ranged from 2.43 to $178.84{\mu}g/m^3$, and 26% days exceeded the daily PM2.5 standard($50{\mu}g/m^3$). During the same periods, only 11% days exceeded the daily PM10 standard, showing that PM2.5 were more concerning levels than PM10. Seasonal variations showed the highest concentrations in spring and winter, and lowest concentration in summer due to heavy rain fall. Changes in PM2.5 concentrations during the day were remarkable and showed the highest concentrations in commuting periods. The results indicated that the concentrations of PM2.5 in Cheonan were at the concerning level, and mainly from the mobile sources.

Correction Factors for Outdoor Concentrations of PM2.5 Measured with Portable Real-time Monitors Compared with Gravimetric Methods: Results from South Korea

  • Yun, Dong-Min;Kim, Myeong-Bok;Lee, Jun-Bok;Kim, Bo-Kyeong;Lee, Dong-Jae;Lee, Seon-Yeub;Yu, Sol;Kim, Sung-Roul
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1559-1567
    • /
    • 2015
  • This study investigated the association between $PM_{2.5}$ concentrations obtained with portable real-time monitors and those obtained with gravimetric methods in national urban air-quality monitoring sites in Seoul, South Korea. We used the SidePak AM510 Personal Aerosol Monitor (TSI Inc., 500 Cardigan Road Shoreview, MN) and DustTrak DRX 8533 (TSI Inc., 500 Cardigan Road Shoreview, MN) as portable real-time monitors for measuring $PM_{2.5}$ concentrations and compared these values with those measured with the PMS-103 or SEQ 47/50 models operated by Federal Reference Method (FRM) or the European Committee for Standardization(ECS), respectively, in national urban air-quality monitoring sites in Seoul. Measurements were conducted every other day in the winter and spring seasons of 2014. The estimated daily mean concentrations of $PM_{2.5}$ ranged between 13.4 and $161.9{\mu}g/m^3$ using AM 510 and between 22.0 and $156.0{\mu}g/m^3$ using DustTrak. The Spearman correlation coefficient for $PM_{2.5}$ concentrations between AM 510 and gravimetric results was 0.99, and the correlation between DustTrak and gravimetric results was 0.87. The correction factor suggested was 0.42 and 0.29 for AM 510 and DustTrak, respectively. We found that $PM_{2.5}$ concentrations measured with real-time monitors could overestimate true $PM_{2.5}$ concentrations and therefore the application of a correction factor (0.43) is strongly suggested for quantification when Real-time monitors were operated of $PM_{2.5}$ levels at urban atmospheric environment of South Korea.

Development and Assessment of Real-Time Quality Control Algorithm for PM10 Data Observed by Continuous Ambient Particulate Monitor (부유분진측정기(PM10) 관측 자료 실시간 품질관리 알고리즘 개발 및 평가)

  • Kim, Sunyoung;Lee, Hee Choon;Ryoo, Sang-Boom
    • Atmosphere
    • /
    • v.26 no.4
    • /
    • pp.541-551
    • /
    • 2016
  • A real-time quality control algorithm for $PM_{10}$ concentration measured by Continuous Ambient Particulate Monitor (FH62C14, Thermo Fisher Scientific Inc.) has been developed. The quality control algorithm for $PM_{10}$ data consists of five main procedures. The first step is valid value check. The values should be within the acceptable range limit. Upper ($5,000{\mu}g\;m^{-3}$) and lower ($0{\mu}g\;m^{-3}$) values of instrument detectable limit have to be eliminated as being unrealistic. The second step is valid error check. Whenever unusual condition occurs, the instrument will save error code. Value having an error code is eliminated. The third step is persistence check. This step checks on a minimum required variability of data during a certain period. If the $PM_{10}$ data do not vary over the past 60 minutes by more than the specific limit ($0{\mu}g\;m^{-3}$) then the current 5-minute value fails the check. The fourth step is time continuity check, which is checked to eliminate gross outlier. The last step is spike check. The spikes in the time series are checked. The outlier detection is based on the double-difference time series, using the median. Flags indicating normal and abnormal are added to the raw data after quality control procedure. The quality control algorithm is applied to $PM_{10}$ data for Asian dust and non-Asian dust case at Seoul site and dataset for the period 2013~2014 at 26 sites in Korea.

Improvement and Evaluation of Automatic Quality Check Algorithm for Particulate Matter (PM10) by Analysis of Instrument Status Code (부유분진(PM10) 측정기 상태 코드 분석을 통한 자동 품질검사 알고리즘 개선 및 평가)

  • Kim, Mi-Gyeong;Park, Young-San;Ryoo, Sang-Boom;Cho, Jeong Hoon
    • Atmosphere
    • /
    • v.29 no.4
    • /
    • pp.501-509
    • /
    • 2019
  • Asian Dust is a meteorological phenomenon that sand particles are raised from the arid and semi-arid regions-Taklamakan Desert, Gobi Desert and Inner Mongolia in China-and transported by westerlies and deposited on the surface. Asian dust results in a negative effect on human health as well as environmental, social and economic aspects. For monitoring of Asian Dust, Korea Meteorological Administration operates 29 stations using a continuous ambient particulate monitor. Kim et al. (2016) developed an automatic quality check (AQC) algorithm for objective and systematic quality check of observed PM10 concentration and evaluated AQC with results of a manual quality check (MQC). The results showed the AQC algorithm could detect abnormal observations efficiently but it also presented a large number of false alarms which result from valid error check. To complement the deficiency of AQC and to develop an AQC system which can be applied in real-time, AQC has been modulated. Based on the analysis of instrument status codes, valid error check process was revised and 6 status codes were further considered as normal. Also, time continuity check and spike check were modified so that posterior data was not referred at inspection time. Two-year observed PM10 concentration data and corresponding MQC results were used to evaluate the modulated AQC compared to the original AQC algorithm. The results showed a false alarm ratio decreased from 0.44 to 0.09 and the accuracy and the probability of detection were conserved well in spite of the exclusion of posterior data at inspection time.

Visible Light Communication Based Wide Range Indoor Fine Particulate Matter Monitoring System (가시광통신 기반 광역 실내 초미세먼지 모니터링 시스템)

  • Shakil, Sejan Mohammad Abrar;An, Jinyoung;Han, Daehyun;Chung, Wan-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.1
    • /
    • pp.16-23
    • /
    • 2019
  • Fine particulate matter known as PM 2.5 refers to the atmospheric particulate matter that has a diameter less than 2.5 micrometer identified as dangerous element for human health and its concentration can provide us a clear picture about air dust concentration. Humans stay indoor almost 90% of their life time and also there is no official indoor dust concentration data, so our study is focused on measuring the indoor air quality. Indoor dust data monitoring is very important in hospital environments beside that other places can also be considered for monitoring like classrooms, cements factories, computer server rooms, petrochemical storage etc. In this paper, visible light communication system is proposed by Manchester encoding technique for electromagnetic interference (EMI)-free indoor dust monitoring. Important indoor environment information like dust concentration is transferred by visible light channel in wide range. An average voltage-tracking technique is utilized for robust light detection to eliminate ambient light and low-frequency noise. The incoming light is recognized by a photo diode and are simultaneously processed by a receiver micro-controller. We can monitor indoor air quality in real-time and can take necessary action according to the result.

A Comparison Study of Aerosol Samplers for PM10 Mass Concentration Measurement (PM10 질량농도 측정을 위한 시료채취기의 비교 연구)

  • Park, Ju-Myon;Koo, Ja-Kon;Jeong, Tae-Young;Kwon, Dong-Myung;Yoo, Jong-Ik;Seo, Yong-Chil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • A PM10 (aerodynamic diameter${\leq}$10 ${\mu}m$) sampler is used to quantify the potential human exposure to suspended particulate matter (PM) and to comply with the governmental regulation. This study was conducted to compare and evaluate the same PM10 cutpoint and different slopes between United States Environmental Protection Agency (USEPA) PM10 sampling criterion and American Conference of Governmental Industrial Hygienists/$Comit\acute{e}$ $Europ\acute{e}en$ de Normalization/International Organization for Standardization thoracic PM10 sampling criterion through theory and experiment. Four PM10 samplers according to the USEPA criterion and one RespiCon sampler in accordance with the thoracic PM10 criterion were used in the present study. In addition, one DustTrak monitor was used to measure real time PM10 mass concentrations. All six aerosol samplers were tested in a PM generation chamber using polydisperse fly ash. Theoretical mass concentrations were calculated by applying the measured particle size distribution characteristics (geometric mean = 6.6 ${\mu}m$, geometric standard deviation = 1.9) of fly ash to each sampling criterion. The measured mass concentrations through a chamber experiment were consistent with theoretical mass concentrations in that a RespiCon sampler with the thoracic PM10 criterion collected less PM than a PM10 sampler with the USEPA criterion. The overall chamber experiment results indicated, when a PM10 sampler was used as a reference sampler, that (1) a RespiCon sampler had a normalizing factor of 1.6, meaning that this sampler underestimated an average 60% of PM10 mass sampled from a PM10 sampler, and (2) a DustTrak real-time monitor using a PM10 inlet had a calibration factor of 2.1.

Dust Spatial Distribution and Emission of Tunnel Ventilated Windowless Broiler Building (터널환기 무창육계사의 분진크기별 분포와 배출농도에 관한 연구)

  • Choi, H.C.;Yeon, G.Y.;Spmg, J.I.;Kang, H.S.;Kwon, D.J.;Yoo, Y.H.;Yang, C.B.;Chun, S.S.;Kim, Y.K.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.115-122
    • /
    • 2006
  • This study investigated the spatial distribution of dust originating from tunnel-ventilated windowless broiler building measuring 12 m wide, 61 m long, with a side wall height of 3 m and a capacity of 16,982 birds. Dust concentrations in terms of total suspended particles (TSP), and particulate matter of sizes $10\;{\mu}m$(PM10), $2.5\;{\mu}m$(PM2.5), and $1\;{\mu}m(PM1)$ were measured at 30 minutes interval by using GRIMM Aerosol Monitor (GRIMM AEROSOL). The spatial distribution of dust showed the lower dust concentration in the inlet than in the outlet of the tunnel ventilation, and dust concentration decreasing as the dust size decreased, as follows: $317.9\;{\mu}g/m^3$ TSP; $74.7{\mu}m/m^3$ PM10; $9.7\;{\mu}g/m^3$ PM2.5; and $6.2\;{\mu}g/m^3$ PM1 in the inlet; and $2,678.5\;{\mu}g/m^3$ TSP; $555.5\;{\mu}g/m^3$ PM10; $33.3\;{\mu}g/m^3$ PM2.5; and $10.2\;{\mu}g/m^3$ PM1 in the outlet. The dust concentration emitted from the tunnel ventilated fan was $446.6\;{\mu}g/m^3$ TSP; $129.1\;{\mu}g/m^3$ PM10; $15.8\;{\mu}g/m^3$ PM2.5; and $6.1\;{\mu}g/m^3$ PM1 in the 3 meters from the fan and $25.1\;{\mu}g/m^3$ TSP; $8.8\;{\mu}g/m^3$ PM10; $5.6\;{\mu}g/m^3$ PM2.5; and $4.9\;{\mu}g/m^3$ PM1 in the 50 meters from the fan.

  • PDF

Development of Monitoring System for Polishing Robot Based on Web

  • Hong, Chang-Woo;Go, Seok-Jo;Lee, Min-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.57.4-57
    • /
    • 2001
  • Polishing a die that has free-form surfaces is a time-consuming and tedious job, and requires a considerable amount of high-precision skill. Some workers tend to gradually avoid the polishing work because of the poor working conditions caused by dust and noise. In the our previous study, an automatic polishing system was developed to reduce the polishing time and cope with the shortage of skilled workers. And, to operate the polishing robot system from remote sites, communication network was constructed and monitoring programs (a server program and a client program)) were developed. However, to monitor polishing process in remote sites, users have to install monitoring programs in a client PC. Thus, user can only operate the polishibg system ...

  • PDF