• Title/Summary/Keyword: Dust collecting

Search Result 73, Processing Time 0.02 seconds

Suggestion and Verification of Architecture for Collecting Fine Dust using Drone (미세먼지 수집 드론의 구조 제안 및 검증)

  • Jo, Young-Jun;Jang, Min-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.125-132
    • /
    • 2020
  • Due to the rapidly increasing number of cars and power generation, environmental pollution caused by fine dust is becoming a serious social problem. Especially fine dust becomes an important issue nowadays. More than 50 countries are suffering from fine dust above the recommended level, and each affected country is studying the measures to reduce fine dust and minimize its occurrence. However, at present, it is difficult to collect fine dust data from the various points with fixed fine dust acquisition drones, and also to collect accurate data due to the influence of rotating blades even in the existing drone method. In this paper, we propose a method for collecting fine dust using drones and a sensing parts architecture and show its effectiveness.

Adsorption Characteristics of BTEX on Dust Collecting Electrode Coated with Activated Carbon (활성탄으로 코팅된 집진전극의 BTEX 흡착특성)

  • Nam, Sangchul;Kim, Hyun Jung;Kim, Kwang Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.773-779
    • /
    • 2013
  • This study was performed to provide the basic data for the function of BTEX removal for compact electrostatic precipitator which are applicable to indoor environment (or closed spaces). For this purpose, the adsorption equilibrium test was conducted for BTEX of activated carbon sheet (ACS) and activated carbon (AC), and the adsorption characteristics of AC and ACS were evaluated using the Langmuir constant which was obtained from the adsorption characteristics, adsorption capacity and regression calculation. The surface area and adsorption pore volume of ACS reduced by 70% and 86%, respectively, as compared to those of AC, and the adsorption capacities of BTEX also showed a similar level. Thus, it is considered that ACS applied electrostatic precipitator is able to remove dust and BTEX simultaneously.

Development of An Operation Monitoring System for Intelligent Dust Collector By Using Multivariate Gaussian Function (Multivariate Gaussian Function을 이용한 지능형 집진기 운전상황 모니터링 시스템 개발)

  • Han, Yun-Jong;Kim, Sung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.470-472
    • /
    • 2006
  • Sensor networks are the results of convergence of very important technologies such as wireless communication and micro electromechanical systems. In recent years, sensor networks found a wide applicability in various fields such as environment and health, industry scene system monitoring, etc. A very important step for these many applications is pattern classification and recognition of data collected by sensors installed or deployed in different ways. But, pattern classification and recognition are sometimes difficult to perform. Systematic approach to pattern classification based on modem learning techniques like Multivariate Gaussian mixture models, can greatly simplify the process of developing and implementing real-time classification models. This paper proposes a new recognition system which is hierarchically composed of many sensor nodes having the capability of simple processing and wireless communication. The proposed system is able to perform context classification of sensed data using the Multivariate Gaussian function. In order to verify the usefulness of the proposed system, it was applied to intelligent dust collecting system.

  • PDF

FEM simulation on dust-collecting performance of tonpilz transducer using finite element method (FEM 시뮬레이션을 이용한 tonpilz 트랜스듀서의 먼지 응집 거동)

  • Seo, Jin-Won;Choi, Kyoon;Lee, Ho-Yong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.6
    • /
    • pp.252-257
    • /
    • 2016
  • Dust-collecting behavior of tonpilz transducer was simulated with finite-element-method (FEM) software. In order to optimize the performance of tonpilz transducer, the shape factors including the thickness of head mass, the diameter of tail mass and the depth of bolt were analyzed as variables. As a vibrating energy source, the piezoelectric materials was also tested with PZT-4 and two kinds of piezoelectric single crystals. The output power of the transducer was maximized with the shape factors and then the behavior of the dust-collection was demonstrated with the multi-physics software, COMSOL.

Dust Collecting Efficiency Using Cyclone Deduster in Weanned Piglet Building (자돈사에서의 사이크론 먼지제거기의 집진효율 분석)

  • 최희철;이덕수;권두중;강희설;유용희;송준익;성환후;김형호;천상석
    • Journal of Animal Environmental Science
    • /
    • v.9 no.1
    • /
    • pp.19-26
    • /
    • 2003
  • This study was carried out to investigate the collecting efficiency of cyclone deduster installed in weaned piglet building in third weeks of age. There are two peaks of high level of dust concentration in piglet house at the time of 09:00~10:00(5,322$\mu g/m^3$) and 19:00~20:00(6,763$\mu g/m^3$), but the peaks of dust concentration in the building used cyclone deduster was decreased to 3,614.8 and 2,229.5$\mu g/m^3$, respectively. Collecting efficiency of total suspended particulate(TSP), particulate matter less than 10$\mu\textrm{m}$(PM 10) and particulate matter less than 2.5$\mu\textrm{m}$(PM 2.5) in weaned piglet building used in cyclone deduster was 38.3%, 32.5, 21.8, respectively. Aerial dust in weaned piglet building by number basis in the range of 0.745~1.08$\mu\textrm{m}$ was 53.5%. But dust distribution over 10$\mu\textrm{m}$ in volume basis was 82.8% and 86.2%. Crude protein of dust was 25.9~32.7%, and it was higher than feed crude protein(22.0%). Heavy metal concentration of dust was also high level compare to that of feed.

  • PDF

Development of Automatic Maintenance and Repair System for Dust Collecting Filter using Intelligent Control (지능제어를 이용한 집진장치용 필터 유지보수 자동화 시스템 개발)

  • Park, Jung-Hoon;Hong, Sung-Hoon;Seo, Kang-Myun;Kang, Moon-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.715-717
    • /
    • 1999
  • In this study, an intelligent solenoid valve controller has been developed for automatic maintaining of filters in a dust collecting system. This controller has automatic controllability of solenoid valves' ON/OFF time depending on the clogging status of filters, and then it can extend the filters' lifetimes, decrease the power consumption, and make effective operation of the system possible. This controllability has been executed by the fuzzy theory that utilizes the workers' experimental knowledges, the control expert's knowledges and the differential pressures between the inlets and outlets measured by the sensors.

  • PDF

Comparison of Tangential and Axial Flow Cyclones for Small Dust Collectors (소형 집진기용 접선식 및 축류식 사이클론 성능비교)

  • Lee, Sungwon;Lee, Chungmin;Yoon, Jong-Hwan
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.2
    • /
    • pp.45-52
    • /
    • 2018
  • The tangential and axial cyclones were fabricated using a 3D printer and the total collecting efficiency, cut-diameter, and pressure drop characteristics of the two types of cyclones with the same inlet area were investigated experimentally. The results show that the total collecting efficiency tends to increase as the inlet velocity increases. However, at a 20m/s condition of the tangential cyclone, the collected particles were re-entrained to the ascending vortex flow, resulting in a decrease of the total collecting efficiency. In the axial cyclone, the cross-sectional area is designed to increase at the inlet and the velocity is reduced, so that the re-entrainment effect does not appear in this study. The pressure loss of the tangential cyclone was larger than that of the axial cyclone. The cut-diameter tends to decrease with increasing the inlet velocity in two types of cyclones, except for the 20m/s condition of the tangential cyclone.

A Study on Feasibility and Applicability of Pneumatic Waste Collection System (쓰레기 수송관로 방식의 적용사례 및 실용에 관한 연구)

  • 민병균;이재영;최상일
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.109-117
    • /
    • 1997
  • The dust chute was a part of equipment in apartment which have been settled down as new residential style in this country since 1960s. However, the dust chute was destructed by results of social discussion, and it ended up old remains which cannot be found in new towns. Nowadays, chute was substituted a collecting system from extra collecting sites which were prepared near residential area. This phenomenon was caused by the poor separating collection. Since the early part of 1995, the whole vocal operating the volume-base charge system has been placed as the institution capable of recycling and separating collection of residential wastes in this country. People pursue the residential quality which is suitable to the Greenround period. Such a diverse effort corresponding to the social change can be also accomplished in the field of waste collecting transportation. In this paper, the local heating system and waste combustion site and hollow are already applied to the new residential area in the form of housing development. After investigating of the waste collecting transportation method in other countries related to such facilities, this paper represents the feasibility and applicability of pneumatic waste collection system which is used practically in the new housing complex and large facilities in other countries.

  • PDF

A Comparison of Cotton Dust Concentrations Measured by Three Dust Samplers (시료채취방법에 따른 면분진의 공기 중 농도 비교)

  • Phee, Young-Gyu;Kim, Hyun-Wook;Byeon, Sang-Hoon
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.5
    • /
    • pp.386-392
    • /
    • 2009
  • This study was undertaken to compare the performance of three dust samplers for collecting cotton dust fibers. For this study, three dust samplers including Vertical Elutriator (VE), Total Dust Method (TDM) using 37 mm cassette, and the Institute of Occupational Medicine (IOM) sampler were selected. A total of 6 cotton mills and 4 towel factories were investigated. When measured by VE, the GM for cotton dust was 0.19 $mg/m^3$ which was less than the current occupational exposure limit (OEL) 0.2 $mg/m^3$. But when measured by TDM and IOM at the same locations, the GMs were 0.37 and 0.63 $mg/m^3$, respectively. In Korea, most industrial hygienists have used the TDM for cotton dust measurements and the results were compared with either the TLV for cotton dust or the PNOC (particulates not otherwise classified) of 10 $mg/m^3$ for making decisions. The results of this study clearly showed that past cotton dust measurements and decisions made with such results were not correct. It needs to be noticed the related contents by using VE if it applies to the exposure limit, 0.2 $mg/m^3$, and needs to be revised the exposure limit by IOM. Also, if TDM is used, it requires to be studied and suggested to the new OEL.

Occurrence of Phthalates in Indoor Dust from Children's Facilities and Apartments in Seoul

  • Kim, Ho-Hyun;Lim, Young-Wook;Yang, Ji-Yeon;Shin, Dong-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.382-391
    • /
    • 2009
  • The aim of the study was to assess the levels in typical central borough of phthalate exposure by monitoring children's facilities (19 kindergartens and 21 elementary schools) and households (17 old apartments and 22 new apartments) via sampling indoor floor dust. A vacuum cleaner specifically prepared for sampling dust was attached to a filter of a vacuum cleaner dust collecting container. During the sample preparation process, containers made of glass were used and analysis was performed using GC-MSD. The mean concentration of DEHP was $412{\mu}g/g$, DnBP was $24{\mu}g/g$, and BBzP was $10{\mu}g/g$ dust. The indoor characteristics including floor, wall materials, years after construction, water leakage history for the past three years, and ventilation were also examined to categorize phthalate esters from the dust samples. From the flooring and wallpaper materials of kindergartens and elementary schools, DEHP in the dust sample appeared at a statistically significant level (p<0.05) when PVC materials were present. DEHP in the indoor dust also increased significantly (p<0.01) during the construction period. The daily intake of DEHP measured from indoor dust was 0.08~$19.7{\mu}g/kg/day$ for children and 0.02~$1.1{\mu}g/kg/day$ for adults (women). The results clearly revealed that phthalate exposure is greater in children than in adults (women) due to the indoor dust.