• Title/Summary/Keyword: Durability factor

Search Result 444, Processing Time 0.023 seconds

An Experimental Study on the Packing Ability of Hardened Cement Paste According to Penetrate by Alkalization Agent (알칼리부여제의 회복에 따른 시멘트 경화체의 충진성에 관한 실험적 연구)

  • 김광기;공민호;박선길;김우재;송병창;정강진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.823-828
    • /
    • 2002
  • Concrete used up to date semipermanent architecture material but now day concrete early deterioration emboss social issue because of construction structure and environmental factor. so, many study of deterioration concrete construction improve durability used impregnation alkalization agent. Impregnation alkalization agent deterioration concrete construction spray infiltration or diffusion improve alkali and filler inter minuteness void elaborateness constitution concrete. but many study of harding concrete change inter minuteness void that Is insufficiency also, To study of method recover shape impregnation alkalization agent apply deterioration concrete construction. impregnation alkalization agent infiltration according to test of porosity, premeameter, absorption.

  • PDF

The Quality Status of Aggregate for Domestic Ready-mixed Concrete and the Effect of Aggregate Quality in Concrete

  • Kim, Yong-Ro;Lee, Jae-Hyun;Min, Choong-Siek;Park, Jong-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.1
    • /
    • pp.11-20
    • /
    • 2014
  • This research examined the effect of the quality of aggregate on concrete workability and compressive strength through an investigation into regional aggregate used in domestic ready mixed concrete plants. Through the research, it was found that aggregate for ready mixed concrete shows poor quality overall. The main factor of deterioration in the quality of the concrete is the particle size of fine aggregate and fine particle content in coarse aggregate. The quality of aggregate significantly influences concrete's workability, which is defined based on 0.08mm passage related with powder and absorption. In addition, poor aggregate quality leads to increased water content in concrete to secure workability, which is related with a decline in the compressive strength and durability of concrete.

A study on Analysis of Contact erosion at a Magnetic Contactor with the Use of Regression Analysis (회귀분석을 이용한 전자접촉기의 접점소모 분석에 대한 고찰)

  • Klm, Myoung-Seok;Ryu, Haeng-Su;Han, Gyu-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.116-118
    • /
    • 2003
  • This paper describes a Accelerated Life Test (ALT) with the electrical contact erosion suitable to the evaluations of high-reliability and durability devices such as magnetic contactor. Recently, an electrical devices company was interested in accelerated life test (ALT), the product liability (PL) and the short-term testing model of electrical life test (ELT). In order to estimate a model for testing fee and period, need to the statistical analysis method with the acceleration factor(AF). Usually customer/manufacturer regard their device failure to the over-current or heavy duty condition, while devices view shape of contact erosion owing to operational duty problem. In this paper, additional method of evaluation estimated the operated cycles by weight of contact erosion with a used of regression analysis by MINITAB.

  • PDF

The Study on Desired Image and Fabric Preference of Woman College Student for Apparel (여자 대학생의 의복 추구 이미지와 소재 선호에 대한 연구)

  • 정인희
    • The Research Journal of the Costume Culture
    • /
    • v.9 no.4
    • /
    • pp.629-638
    • /
    • 2001
  • This study was intended to identify the desired image and fabric preference of woman college student for apparel and the relationship between these variables. Data were collected by questionnaire distributed to 260 woman college students through August to September of 2000. After eliminating incomplete questionnaires, 236 were analyzed. The most desired image was neat, and the most preferred fabric was natural fiber textile in fiber contents and light and soft in fabric sensation. The avoided image was masculine, and the negative sensation was heaviness. As a result of factor analysis, 7 factors -cute, intellectual, animate, neat, mature, sporty, sexy- were determined in image. And 8 factors -soft, durable, flat, rigid, light, bulky, heavy, pliable- were determined in fabric sensation. These factors explained large percentage of variance respectively. Multidimensional scaling was employed to analyze the relationship between desired image and fabric preference. Two dimensions were accepted to interpret the relationship. One of the results showed the closeness among the natural fiber textile, lightness, durability and natural image. And the short distance among the blended textile, elasticity, warmness and sporty image was presented.

  • PDF

To Experimental Study of Alkalinity Recovery Agent application in field (알칼리회복제의 현장 적용성에 관한 실험적 연구)

  • 김광기;박선길;김우재;이영도;송병창;정상진
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.7-10
    • /
    • 2002
  • Concrete used up to date semipermanent architecture material but now day concrete early deterioration emboss social issue because of construction structure and environmental factor. so, many study of deterioration concrete construction improve durability used impregnation alkalization agent. In These to Study of derelop reoairmeat material in reduce carbonation. xoncrete Building use Alkalinity Recovery Agent which is Realkalinity and strength surface. Alkalinity Recovery Agent undisposed application volume and cure the concrete period. To study Alkalinity Recovery Ahent spray and cure the concrete propriery in field.

  • PDF

An Experimental Study on Freezing and Thawing Resistance of Rice Straw Ash Concrete (볏짚재 콘크리트의 동결융해 저항성에 관한 실험적 연구)

  • 김영익;성찬용;김경태;서대석;남기성
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.161-166
    • /
    • 1998
  • This experiment was on purpose to estimate freezing and thawing resistance concering with developing rice straw ash concrete which were mixed rice straw ash to cement as ratio of cement weight. Freezing and thawing test was done by Method A of KS F 2456. It could estimate change of original mass, pulse velocity and dynamic modulus of elasticity during test. Test results showed that 5% filled rice straw ash concrete had the highest durability factor(DF) as 86 and from 5% to 7.5% filled rice straw ash concrete showed higher DF than normal cement concrete.

  • PDF

The Grading of Fine Aggregate Affecting on Compressive Strength of Concrete - Based Product Having Low W/C (낮은 물시멘트비를 갖는 콘크리트 제품의 압축강도에 미치는 잔골재의 입도분포)

  • 곽은구;주지현;조성현;김진만
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.89-92
    • /
    • 2001
  • Because the grading of aggregate is major factor affecting on compressive strength and durability of concrete, the standard specification of concrete has proposed that the standard grading should be used to make ordinary concrete having good quality. But, it is not suitable for making product having low W/C because of difference between them in manufacturing processes and demanded efficiencies. This study investigated if the grading of the fine aggregate affects on tamping efficiency and compressive strength of concrete-based product. The results of this study showed that the suitable grading for making concrete-based product ranged from C type(FM:2.77) to D type(FM:3.38).

  • PDF

An experimental study on surface performance improvement of concrete influencing on resistance to chloride (콘크리트의 표면성능개선이 염소이온투과저항성에 미치는 영향에 관한 실험적 연구)

  • Kim, Jae-Sung;Kang, Suk-Pyo;Hong, Sung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.782-785
    • /
    • 2004
  • Salt attack is one of the serious deterioration factor with respect to the durability of concrete structure. Especially, in case of exposed rebar concrete structure in marine environment, corrosion of rebar is accelerated by penetration of $Cl^-$ from exterior. Through this path, volume of corroded rebar is increased about two and half times due to increased inner pressure originated from rust. As a consequence, the overall deterioration of concrete structure, namely, cracks, reduction of adhesive strength and pop-out is followed. In this paper, the effect of structure treatment of concrete on chloride resistance has been investigated. At the same time, the relationship among several characteristics, such as resistance to chloride, water absorption coefficient and surface hardness of concrete has been investigated. It is believed that surface performance improvement by the application of penetrative hardening agent influences on positively water absorption coefficient, surface hardness of concrete and resistance to chloride ion penetration.

  • PDF

A Study on the Freezing and Thawing Resistance of Permeable Polymer Concrete (투수성 폴리머 콘크리트의 동결융해 저항성에 관한 연구)

  • 박응모;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.331-336
    • /
    • 1999
  • Permeable polymer concrete in this study is one of the environment conscious concrete that can be applied at road, side walks and river embankment, etc. The purpose of this study is to evaluate the effects of mix proportions such as resing content, filler-binder ratio and aggregate ratio on the freezing and thawing resistance of permeable polymer concrete. The permeable polymer concrete are prepared with the resin ratio of 5%, 6% and 7%, filler-binder ratio of 0, 0.5 and 1.0, and 2.5~5mm sized aggregate ratio to standard sand of 10:10, 10:20, 20:10 and 20:20. It is tested for freezing and thawing test according to ASTM C 666092, and then, weight change, length change, relative dynamic modulus, durability factor, and compressive and flexural strengths after test are measured. From the test results, the resistance to freezing and thawing of permeable polymer concrete increased with increase the resing content, filler-binder ratio and fine aggregate ratio.

  • PDF

A Chloride Ion Diffusion Model in Blast Furnace Slag Concrete (고로슬래그 미분말 콘크리트의 염화물이온 확산모델)

  • 이석원;박상순;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.467-472
    • /
    • 2000
  • It is known that chloride ion in concrete destroys the passive film of reinforcement inside concrete and accelerates corrosion which is the most influencing factor to durability of concrete structures. In this thesis, a chloride ion diffusion model for blast furnace slag(BFS) concrete, which has better resistance to both damage due to salt and chloride ion penetration than ordinary portland cement concrete, is proposed by modifying existing model of normal concrete. Proposed model is verified by comparing diffusion analysis results with both results by indoor chloride penetration test for specimens and field test results for actual RC bridge pier. Also, the optimum resistance condition to chloride penetration is obtained according to degrees of fineness and replacement ratios of BFS concrete. As a result, resistance to chloride ion penetration for BFS concrete is more affected by replacement ratio than degree of fineness.

  • PDF