• Title/Summary/Keyword: Duct Model

Search Result 332, Processing Time 0.027 seconds

A Study on Motion and Wave Drift Force of a BBDB Type OWC Wave Energy Device (BBDB형 진동수주 파력발전장치의 운동 및 파랑표류력 연구)

  • Kim Jin-Ha;Lew Jae-Moon;Hong Do-Chun;Hong Seok-Won
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.2 s.69
    • /
    • pp.22-28
    • /
    • 2006
  • The motion and wave drift forces of floating BBDB (backward-bent duct buoy) wave energy absorbers in regular waves are calculated, taking account of the oscillating surface-pressure due to the pressure drop in the air chamber above the oscillating water column, within the scope of the linear wave theory. A series of model tests has been conducted in order to order to verify the motion and time mean wave drift force reponses in regular waves at the ocean engineering basin, MOERI/KORDI. The pneumatic damping through an orifice-type duct for the BBDB wave energy device are deducted from experimental research. Numerical simulation for motion and drift force responses of the BBDB wave energy device, considering pneumatic damping coefficients, has been carried out, and the results are compared with those of model tests.

A Study on Velocity Distribution Characteristics for Each Location and Effectiveness of Straight Duct Length in a Square-sectional 180° Bended Duct (정사각형 단면을 갖는 180° 곡관에서 위치별 속도분포특성 및 직관거리의 유효성에 관한 연구)

  • Chen, Jing-Jing;Yoon, Jun-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.618-627
    • /
    • 2016
  • This study numerically analyzes the characteristics of the velocity distribution for each location of a square-sectional $180^{\circ}$ bent duct using a Reynolds Stress Turbulent model. The flow parameters were varied, including the working fluids, inlet velocity, surface roughness, radius of curvature, and hydraulic diameter. The boundary conditions for computational fluid dynamics analysis were inlet temperatures of air and water of 288 K and 293 K, inlet air velocity of 3-15 m/s, inner surface roughness of 0-0.001 mm, radius of curvature of 2.5-4.5 D, and hydraulic diameter of 70-100 mm. The working fluid characteristics were highly affected by changes in the viscous force. The maximum velocity profiles in the bent duct were indicated when the $90^{\circ}$ section was in the region of X/D=0.8 and the $180^{\circ}$ section was in the region of Y/D=0.8. Lower surface roughness and higher radius of curvature resulted in a higher rate of velocity change. Also, an efficient measuring location downstream of the bent duct is suggested since the flow deviations were the most stable when the straight duct length was in the region of L/D=30. The minimum deviations at the same velocity conditions according to the hydraulic diameter were mostly indicated in the range of L/D=15-30 based on the standard deviation characteristics.

Investigation of Motion of Single Point Moored Duct-type TCP System by Both Numerical and Experimental Method (수치 해석 및 모형실험을 이용한 수중 일점 계류식 조류발전 장치의 운동 성능 고찰)

  • JO, CHUL HEE;PARK, HONG JAE;CHO, BONG KUN;KIM, MYEONG JOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.212-219
    • /
    • 2017
  • As an environmental pollution and global warming due to an excessive carbon emission are intensified, the importance of renewable energy is in rise today. TCP (Tidal Current Power), one of the renewable energy sources, generates electricity by converting kinetic energy of current into rotational energy of turbine. Also the TCP has a great advantages of predictability and reliability. Because the generating power is proportional to cubic of stream velocity, amplifying current speed by applying duct is highly effective to increase the generating power. SPM (Single Point Mooring) can be applied for the weather vane with various current direction and also augments generating power of the system. In addition, simple installation and retrieval could be a merit of SPM system. By combining duct and SPM, TCP system for relatively low-speed-current and shallow water region can be feasible and economical. In this study, single point moored duct-type TCP system was designed and the motion of submerged structure was investigated in both numerical and experimental method. DNV wadam V4.8-1 and OrcaFlex 10.0a were used for the frequency and time domain motion analysis of system respectively. Duct model scaled by 0.05 of Froude conformity ratio and CWC (Circulate Water Channel) are used for experiment.

Numerical study on overall thermal performance in SAH duct with compound roughness of V-shaped ribs and dimples (V 형 rib과 dimple로 구성된 SAH 덕트에서의 총괄 열성능에 대한 수치적 연구)

  • Kumar, Anil;Kim, Man-Hoe
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.43-55
    • /
    • 2015
  • This paper presents the thermal hydraulic performance of a three dimensional rib-roughened solar air heater (SAH) duct with the one principal wall subjected to uniform heat flux. The SAH duct has aspect ratio of 12.0 and the Reynolds number ranges from 2000 to 12000. The roughness has relative rib height of 0.045, ratio of dimple depth to print diameter of 0.5 and rib pitch ratio of 8.0. The flow attack angle is varied from $35^{\circ}$ to $70^{\circ}$. Various turbulent flow models are used for the heat transfer and fluid flow analysis and their results are compared with the experimental results for smooth surfaces. The computational fluid dynamics (CFD) results based on the renormalization k-epsilon model are in better outcomes compared with the experimental data. This model is used to calculate heat transfer and fluid flow in SAH duct with the compound roughness of V-shaped ribs and dimples. The overall thermal performance based on equal pumping power is found to be the highest (2.18) for flow attack angle of $55^{\circ}$. The thermo-hydraulic performance for V-pattern shaped ribs combined with dimple ribs is higher than that for dimple rib shape and V-pattern rib shape air duct.

Numerical Study on the Turbulent Flow in the 180^{\circ}$ Bends Decreasing Cross-sectional Aspect Ratio (단면의 폭이 감소하는 180^{\circ}$ 곡덕트 내 난류유동의 수치해석적 연구)

  • 김원갑;최영돈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1056-1062
    • /
    • 2002
  • This paper reports the characteristics of the three dimensional turbulent flow in the 180 degree bends with decreasing cross-sectional area by numerical method. Calculated pressure and velocity, Reynolds stress distributions are compared to the experimental data. Turbulence model employed are low Reynolds number k-epsilon model and algebraic stress model. The results show that the main vortex generated from the inlet part of the bend maintained to outlet of the bend because of the contraction of cross-sectional area. The rate of increase of turbulent kinetic energy through the bend are lower than that of mean flow. Secondary flow strength of the flow is lower about 60% than that of square duct flow.

Numerical Study on the Turbulent Flow in the $180^\circ$ Bends increasing Cross-sectional Aspect Ratio (단면의 폭이 증가하는 $180^\circ$ 곡덕트 내 난류유동의 수치해석적 연구)

  • 김원갑;김철수;최영돈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.804-810
    • /
    • 2004
  • This paper reports the characteristics of the three dimensional turbulent flow by numerical method in the 180 degree bends with increasing cross-sectional area. Calculated pressure and velocity, Reynolds stress distributions are compared to the experimental data. Turbulence model employed are low Reynolds number $textsc{k}$-$\varepsilon$ model and algebraic stress model(ASM). The results show that the main vortex generated from the inlet part of the bend maintained to outlet of the bend and vortices are continually developed at the inner wall region. The distribution of turbulent kinetic energy along the bend are increase up to 120$^{\circ}$ because of increment of cross-sectional area. Secondary flow strength of the flow is lower about 60% than that of square duct flow.

Numerical Study on Heat Transfer Characteristics of Turbulent Flow in Transition Duct (안내덕트 내부 난류유동구조에 따른 열전달 특성변화 수치해석)

  • Yoo, Geun-Jong;Choi, Hoon-Ki;Choi, Kee-Lim
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.923-932
    • /
    • 2011
  • Because of the instability of a flow pattern in the inlet transition square duct (hereinafter referred to as "transition duct") of a heat recovery steam generator (hereinafter referred to as "HRSG") in a combined cycle power plant, the Reynolds number in the first row of a tube bank is differs sharply from that in the sectional area of the transition duct. This causes differences in the heat flux in each tube in the tube bank. The computational fluid dynamics (CFD) predictions provide three-dimensional results for velocity, temperature, and other flow parameters over the entire domain of the duct and HRSG. A renormalization group theory (RNG) based k-${\epsilon}$�� turbulent model is used for obtaining the results cited in this study. A porous media option is used for modeling the tube banks and the number of transfer units method is used for determining the heat transfer characteristics. This study describes a comparison between the numerical simulation results and actual design output.

Effect of Interconnected Boundary Between Journal and Thrust Bearings on the Performance of Self-Acting Air-Lubricated Bearings (저널-스러스트 베어링 사이의 상호 연결 경계가 동압 공기 윤활 베어링의 성능에 미치는 영향)

  • Kang, Ji-Hoon;Kim, Sung-Ki;Kim, Kyung-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.608-613
    • /
    • 2003
  • In this paper, the effect of interconnected boundary between journal and thrust bearings on the performance of self-acting air-lubricated bearings is investigated. When journal and thrust bearings have common boundary, conventional boundary condition which assumes that the boundary pressure is equal to atmosphere is no more valid. Instead, new boundary condition by mass conservation at interconnected boundary is needed. To do this, a duct model satisfying mass conservation at interconnected boundary is developed. Using this model, pressure distribution at interconnected boundary is numerically analyzed with changing the volume of interconnecting part. As a result, it is shown that load capacity of thrust bearing can be greatly increased when journal and thrust have a common boundary.

3-Dimensional Locally Elliptic Numerical Predictions of Turbulent Jet in a Crossflow In A Curved Duct (곡관내의 주유동에 분사되는 난류제트에 대한 3차원 국소타원형 수치해석)

  • 정형호;이택식;이준식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.470-483
    • /
    • 1990
  • Turbulent jet in a crossflow, issuing from a row of holes on a convex surface of 90 .deg. bend duct, is predicted by a 3-dimensional numerical method. The Cartesian coordinate system in adopted in upstream and downstream tangents and the cylindrical polar coordinate system in curved region. The Reynolds stresses and heat fluxes are obtained from a standard k-e model in the core region and van Driest model in the vicinity of the wall. The governing equations are discretized by a finite volume method and solutions are obtained by a locally elliptic calculation procedure. Pressure and convective terms are treated by SIMPLE algorithm and hybrid scheme respectively. A vortex initially induced by the injected jet has been built up due to the interaction with the secondary flow caused by pressure gradient and centrifugal force. The vortex structure has a strong influence on the wall cooling effectiveness. Another vortex like horseshoe is formed in the vicinity of the injection hole and its strength is getting weak as it moves downward.