• 제목/요약/키워드: Dual-Energy Technique

검색결과 89건 처리시간 0.022초

Single Fiber Composite(SFC) 시험법과 Acoustic Emission(AE)를 이용한 고분자 복합재료 계면전단강도 및 미세파손기구의 해석

  • 이준현;박종만;윤동진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.656-659
    • /
    • 1993
  • The failure phenomenon of Dual Basalt Fibers Reinforced Epoxy Composites(DFC) under tensile load was studied using acoustic emission(AE) technique. AE amplitude and AE energy were mainly associated with the internal microscopic failure mechanism of DFC specimen, such as fiber fracture, matrix cracking, and fiber/matrix debonding. Fiber failures in the DFC specimens were distinguishable by showing the highest AE energy amplitude. They were dependant on the fiber diameters. Matrix cracking was determined from the relatively lower AE amplitude and AE energy, whereas fiber/matrix debonding could not be successfully isolated. AE method, however, can be applicable to the fragmentation method for interfacial strength(IFSS) in DFC specimens with adjusting the threshold to isolate fiber breaks from matrix crack and debonding.

  • PDF

Micromechanical 시험법과 음향방출을 이용한 Implant용 Bioabsorbable 복합재료의 미세파괴 분해메커니즘과 계면물성 (Microfailure Degradation Mechanisms and Interfacial Properties of Bioabsorbable Composites for Implant Materials using Micromechanical Technique and Acoustic Emission)

  • 박종만;김대식
    • Composites Research
    • /
    • 제14권4호
    • /
    • pp.15-26
    • /
    • 2001
  • Implant용 bioabsorbable 복합재료의 계면물성과 미세파괴분해 메카니즘을 micromechanical 시험법과 음향방출을 이용하여 평가하였다. Poly(ester-amide)와 bioactive 유리섬유의 인장 강도와 탄성률 그리고 연신율은 분해시간에 따라 점차적으로 감소하는 경향을 보인 반면, chitosan 섬유는 분해시간 내에서 거의 변화가 없었다. Dual matrix composite 시험법을 이용하여 측정된 bioactive 유리섬유와 poly(L-lactide) 사이의 계면전단강도는 chitosan이나 poly(ester-amide) 섬유의 경우 보다 큰 값을 보였다. 그리고 계면전단강도 감소는 bioactive 유리섬유 강화 poly(L-lactide) 복합재료에서 가장 빨랐으며, chitosan 섬유의 경우가 상대적으로 가장 느린 경향을 보였다. Poly(ester-amide) 섬유의 분해시간에 따른 음향방출 진폭과 에너지는 점차로 감소하였고, 음향방출 진폭의 분포 역시 점차 좁아짐을 보여주었다. Bioactive 유리섬유에서 인장파단에 의한 음향방출 진폭과 에너지는 압축파단의 경우 보다 크게 나타났으며, 또한, 인장 및 압축시험 모두에서 초기상태가 분해 후 보다 더 큰 값을 보였다. 본 연구에서 평가한 계면물성과 미세파괴분해 메카니즘은 생흡수성 복합재료의 성능을 조절할 수 있는 중요한 요소가 될 것이다.

  • PDF

Calibration을 통한 스테레오 X-ray 검색장치의 기하구조 최적화 연구 (The Study of the Geometric Structure Optimization for the Stereo X-ray Inspection System Using the Calibration)

  • 황영관;이남호;이승민
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3422-3427
    • /
    • 2010
  • 본 논문에서는 빠르게 움직이는 화물 대상체의 효율적인 검색을 위해 스테레오 X-선 영상을 이용하여 장치 켈리브레이션을 통한 최적화된 구조에 대하여 연구하였다. 스테레오 X-선 스캔 영상은 X-선 발생장치, 듀얼 라인 어래이 검출기, 컨베이어 시스템 등으로 구성된 특별하게 제작된 스테레오 X-선 검색 장치로부터 획득하였다. 스테레오 X-선 영상을 이용하여 영상과 실제 대상체의 3차원 형상 구성사이의 관계를 찾기 위해 센서에 대한 캘리브레이션을 수행하였다. 스테레오 영상을 얻기 위해 구성된 두 개의 검출기 사이의 거리를 다양하게 변화 시키며 획득한 영상을 이용하여 영상에서의 GCP(Ground Control Point)에 대하여 계산 하였다. 계산된 GCP 값과 실제 대상체의 GCP의 좌표값을 비교하여 오차가 작은 효율적인 장치의 구조에 대하여 결과를 얻었다. 실험의 결과는 화물검색을 위한 영상의 효율적인 가시화 및 스테레오 매칭의 정확도를 향상시키기 위해 활용될 것이다.

보코더에서 프레임별 에너지 보상에 의한 피치검색 성능 개선에 관한 연구 (An Algorithm on Improving a Pitch Searching by Energy Compensation in a Frame for Vocoder)

  • 백금란;민소연;배명진
    • 한국산학기술학회논문지
    • /
    • 제13권7호
    • /
    • pp.3188-3193
    • /
    • 2012
  • 보코더 과정 중 피치를 분석하는 과정은 코드북 분석과 더불어 부호화기 성능에 큰 영향을 미치는 부분이다. 피치를 검색하기 위해 먼저 신호의 주기성을 강조해야 하는데 일반적으로 자기상관법의 일종인 듀얼 펄스 알고리즘 기법을 이용하여 주기성을 강조한 후 피치를 검색하는 방법을 많이 사용한다. 이 방법은 한 프레임 내에서 두 개의 펄스 간격을 변경시키면서 음성신호와의 상관관계 값을 구하여 상관관계가 가장 높을 때의 펄스 간격을 찾는다. 또한 상관관계 값이 가장 높을 때의 주기가 가장 뚜렷한 반복 구간인데 이것을 피치 주기라 한다. 이때 반주기, 배주기 및 세배주기가 주된 주기로 찾아지는 경우에는 이 간격을 피치 주기라 할 수 없어 이를 해결하기 위한 여러 가지방법들이 제안되어 있다. 본 논문에서는 피치를 검색하기 전에 프레임내의 전체 에너지변화 비율을 추정하여 신호의 에너지 레벨을 미리 보상해 준 후 피치를 검색하는 방법을 제안한다. 이 방법을 적용하면 피치검색 시간을 단축할 수 있고, 피치 검색의 정확도를 높일 수 있어 전반적인 피치 검색에 관한 성능이 개선된다.

Characterization of a CLYC Detector and Validation of the Monte Carlo Simulation by Measurement Experiments

  • Kim, Hyun Suk;Smith, Martin B.;Koslowsky, Martin R.;Kwak, Sung-Woo;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.48-55
    • /
    • 2017
  • Background: Simultaneous detection of neutrons and gamma rays have become much more practicable, by taking advantage of good gamma-ray discrimination properties using pulse shape discrimination (PSD) technique. Recently, we introduced a commercial CLYC system in Korea, and performed an initial characterization and simulation studies for the CLYC detector system to provide references for the future implementation of the dual-mode scintillator system in various studies and applications. Materials and Methods: We evaluated a CLYC detector with 95% $^6Li$ enrichment using various gamma-ray sources and a $^{252}Cf$ neutron source, with validation of our Monte Carlo simulation results via measurement experiments. Absolute full-energy peak efficiency values were calculated for gamma-ray sources and neutron source using MCNP6 and compared with measurement experiments of the calibration sources. In addition, behavioral characteristics of neutrons were validated by comparing simulations and experiments on neutron moderation with various polyethylene (PE) moderator thicknesses. Results and Discussion: Both results showed good agreements in overall characteristics of the gamma and neutron detection efficiencies, with consistent ~20% discrepancy. Furthermore, moderation of neutrons emitted from $^{252}Cf$ showed similarities between the simulation and the experiment, in terms of their relative ratios depending on the thickness of the PE moderator. Conclusion: A CLYC detector system was characterized for its energy resolution and detection efficiency, and Monte Carlo simulations on the detector system was validated experimentally. Validation of the simulation results in overall trend of the CLYC detector behavior will provide the fundamental basis and validity of follow-up Monte Carlo simulation studies for the development of our dual-particle imager using a rotational modulation collimator.

상호작용 이중-모드 조정방법을 이용한 저항률 영상 복원 (Resistivity Image Reconstruction Using Interacting Dual-Mode Regularization)

  • 강숙인;김경연
    • 전기전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.152-162
    • /
    • 2016
  • 전기 저항률 단층촬영법(ERT)은 표면 전극으로부터 측정된 전압을 사용하여 물체 내부의 임피던스 분포를 영상화하는 기술이다. ERT 역문제는 비정치성(ill-posedness)이 매우 심하여 영상복원의 수렴성을 확보하기 위해 조정방법이 사용된다. 사용된 조정방법에 따라 영상복원 성능이 달라지므로 상황에 따라 보다 강건한 영상 복원 성능을 얻기 위해, 서로 다른 영상복원 특성을 나타내는 L1-norm 조정방법과 Total Variation (TV) 조정방법의 두 개의 모드가 상호작용하는 상호작용 이중-모드 조정방법을 제안하였다. 제안한 이중-모드 조정방법은 실제 상황에 따라 달라지는 모드 확률을 계산하고 이에 근거하여 적합한 모드를 선택하거나 두 개의 모드를 결합한다. 모의실험을 수행하여 제안된 기법의 영상 복원 성능을 평가한 결과 비교적 양호한 성능을 나타내었다.

피부 T 세포림프종의 전 피부 전자선 치료를 위한 dosimetry 연구 (A Study on the Dosimetry of the Total Skin Electron Beam Therapy in Cutaneous T-Cell Lymphoma)

  • 신교철;윤형근
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.57-65
    • /
    • 1996
  • 피부 T 세포림프종에 대하여 4MeV 의 전자선으로 전 피부 방사선 조사를 시행하였다. 피부전체의 균일한 선량분포를 위하여 스탠포드대학의 방법으로 알려져 있는 six dual field 기법을 사용하였다. SSD 는 390cm로 하였으며 방사선 조사시의 gantry 의 각은 환자의 중심을 지나는 수평축에 대하여 상ㆍ하로 14$^{\circ}$가 되도록 하였다. 전자콘을 설치해야만 전자선 조사가 가능하므로 최대의 전자콘인 25$\times$25cm콘을 사용하였다. 치료면에서의 선량분포의 균일성을 확인하기 위하여 치료면에 90$\times$180cm의 폴리스틸렌을 설치하고 Famer type ion chamber와 측정용 필름을 사용하여 측정하였다. 그 결과 치료면에서 10% 정도의 균일함을 보였다. 환자의 자세를 하루에 세가지씩 이틀에 걸쳐 여섯가지 자세를 한 주기로 치료를 시행하였다. 선량이 부족한 정수리, 회음부, 발바닥 등은 따로 추가의 방사선을 조사하였다. 렌즈와 손톱, 발톱은 차폐물을 제작하여 차폐하였다.

  • PDF

유한요소해에 기초한 이중 삼각뿔 압입 물성평가법 (A Dual Triangular Pyramidal Indentation Technique Based on FEA Solutions for Material Property Evaluation)

  • 김민수;현홍철;이진행;이형일
    • 대한기계학회논문집A
    • /
    • 제36권1호
    • /
    • pp.17-28
    • /
    • 2012
  • 본 연구에서는 역해석 방법을 통해, 중심각이 서로 다른 두 삼각뿔 압입자를 이용하는 재료물성 평가법을 제안한다. 자기유사성을 갖는 첨단형 압입자를 사용한 압입시험 전산모사시, 동일 압입깊이에 대해 원뿔형 및 삼각뿔 압입자가 주는 하중-변위 곡선들이 다름을 확인했다. 따라서 삼각뿔형 압입자를 이용한 물성평가는 원뿔형 압입자와 별도로 독립적인 연구가 필수적이다. 먼저 다양한 재료들에 대한 삼각뿔 압입 유한요소해석들로 얻은 하중-변위 곡선들의 특징을 살폈다. 이를 토대로 압입자 반각이 다른 두 삼각뿔 압입자를 이용해 유한요소해석으로 얻은 하중-변위곡선들의 회귀분석으로 재료물성치를 얻는 이중 삼각뿔 압입물성평가 알고리듬을 제시했다. 제안된 물성평가법을 이용하면 다양한 재료에 대해 평균오차 3% 이내로 영률 및 항복강도, 변형경화지수의 예측이 가능하다.

전위된 하부 천골 횡골절에 대한 이중 금속판을 이용한 내고정술 (Dual Plate Fixation for Displaced Transverse Fracture of the Lower Sacrum)

  • 최동혁;박지훈;심승우;최용수
    • 대한정형외과학회지
    • /
    • 제55권2호
    • /
    • pp.178-182
    • /
    • 2020
  • 하부 천골의 단독 골절은 일반적으로 저에너지 손상으로 안정된 골절이 많아 대부분의 경우에서 보존적 치료가 이루이지고 있고 그 결과도 좋은 것으로 보고되고 있다. 하지만 전위된 불안정 골절에서는 수술적 치료의 필요성이 요구되나 치료 방법이 정립되어 있지 않으며 증례보고마저 매우 드물다. 이에 저자들은 하부 천골의 전위된 횡골절에 대해 관혈적 정복 및 이중 금속판을 이용한 내고정술을 치험한 증례를 보고하고자 한다.

Design of a 12b SAR ADC for DMPPT Control in a Photovoltaic System

  • Rho, Sung-Chan;Lim, Shin-Il
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권3호
    • /
    • pp.189-193
    • /
    • 2015
  • This paper provides the design techniques of a successive approximation register (SAR) type 12b analog-to-digital converter (ADC) for distributed maximum power point tracking (DMPPT) control in a photovoltaic system. Both a top-plate sampling technique and a $V_{CM}$-based switching technique are applied to the 12b capacitor digital-to-analog converter (CDAC). With these techniques, we can implement a 12b SAR ADC with a 10b capacitor array digital-to-analog converter (DAC). To enhance the accuracy of the ADC, a single-to-differential converted DAC is exploited with the dual sampling technique during top-plate sampling. Simulation results show that the proposed ADC can achieve a signal-to-noise plus distortion ratio (SNDR) of 70.8dB, a spurious free dynamic range (SFDR) of 83.3dB and an effective number of bits (ENOB) of 11.5b with bipolar CMOS LDMOD (BCDMOS) $0.35{\mu}m$ technology. Total power consumption is 115uW under a supply voltage of 3.3V at a sampling frequency of 1.25MHz. And the figure of merit (FoM) is 32.68fJ/conversion-step.