• 제목/요약/키워드: Dry storage

검색결과 666건 처리시간 0.021초

Pheophytin Content and Cytotoxicity of Silkworm Feces Against Jurkat Cells According to Dry Method and Storage Period

  • Ahn, Mi-Young;Kim, Iksoo;Ryu, Kang-Sun;Kim, Jin-Won;Lee, Heui-Sam;Lee, Pyeong-Jae;Ko, Si-Hwan;Lee, Won-Young
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제8권2호
    • /
    • pp.135-138
    • /
    • 2004
  • In order to find potential anticancer agents, we extracted pheophytin from silkworm feces according to various dry and storage methods such as sun dry, shade dry, fresh freezing dry and freezing dry after freezing storage (for 1∼3 years). The pheophytin extracts, mainly 10-hydroxypheophytin a, little b, of various storage silkworm feces were analyzed by reversed-phase high-performance liquid chromatography with photodiode array and fluorescence detection. The content of those pheophytih in old silkworm for 3 years (freezing storage and freezing dried in use, or freezing dried and cold storage) was better than others. The cytotoxicity of the pheophytin extracts and ethanol extracts of various storage silkworm feces were measured using Jurkat cells originated from human leukemia, using dye uptake assay (MTT) in order to find effective photodynamic therapeutic agents. The anticancer activity of those pheophytin extracts in various storage methods showed little difference among them. But ethanol extracts of fresh freezing dried silkworm in the current year was good cytotoxic activity than those of any other silkworm feces. With regards to these results, fresh ethanol extracts of silkworm feces were better than old ones. On the other hands, the pheophytin extracts of old silkworm feces contained the highest percentage of pheophytin content and showed good cytotoxicity against cancer cells by changing the pheophytin into pheophobide in the degradative process.

The effect of peak cladding temperature occurring during interim-dry storage on transport-induced cladding embrittlement

  • Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1486-1494
    • /
    • 2020
  • To evaluate transport-induced cladding embrittlement after interim-dry storage, ring compression tests were carried out at room temperature(RT) and 135 ℃. The ring compression test specimens were prepared by simulating the interim-dry storage conditions that include four peak cladding temperatures of 250, 300, 350 and 400 ℃, two tensile hoop stresses of 80 and 100 MPa, two hydrogen contents of 250 and 500 wt.ppm-H and a cooling rate of 0.3 ℃/min. Radial hydride fractions of the ring specimens vary depending on those interim-dry storage conditions. The RT compression tests generated lower offset strains than the 135 ℃ ones. In addition, the RT and 135 ℃ compression tests indicate that a higher peak cladding temperature, a higher tensile hoop stress and the lower hydrogen content generated a lower offset strain. Based on the embrittlement criterion of 2.0% offset strain, an allowable peak temperature during the interim-dry storage may be proposed to be less than 350 ℃ under the tensile hoop stress of 80 MPa at the terminal cool-down temperature of 135 ℃.

경수로 사용후핵연료 건식저장시스템의 격납감시 기술현황 분석 (Status Analysis for the Confinement Monitoring Technology of PWR Spent Nuclear Fuel Dry Storage System)

  • 백창열;조천형
    • 방사성폐기물학회지
    • /
    • 제14권1호
    • /
    • pp.35-44
    • /
    • 2016
  • Leading national R&D project to design a PWR spent nuclear fuel interim dry storage system that has been under development since mid-2009, which consists of a dual purpose metal cask and concrete storage cask. To ensure the safe operation of dry storage systems in foreign countries, major confinement monitoring techniques currently consist of pressure and temperature measurement. In the case of a dual purpose metal cask, a pressure sensor is installed in the interspace of bolted double lid(primary and secondary lid) in order to measure pressure. A concrete storage cask is a canister based system made of double/redundant welded lid to ensure confinement integrity. For this reason, confinement monitoring method is real time temperature measurement by thermocouple placed in the air flow(air intake and exit) of the concrete structure(over pack and module). The use of various monitoring technologies and operating experiences for the interim dry storage system over the last decades in foreign countries were analyzed. On the basis of the analysis above, development of the confinement monitoring technology that can be used optimally in our system will be available in the near future.

Irradiation Effect on Silo Dry Storage Systems for CANDU Spent Nuclear Fuel

  • Taehyung Na;Yeji Kim;Donghee Lee;Taehyeon Kim;Sunghwan Chung
    • 방사성폐기물학회지
    • /
    • 제22권2호
    • /
    • pp.117-128
    • /
    • 2024
  • The 300 concrete silo systems installed and operated at the site of Wolsong nuclear power plant (NPP) have been storing CANDU spent nuclear fuel (SNF) under dry conditions since 1992. The dry storage system must be operated safely until SNF is delivered to an interim storage facility or final repository located outside the NPP in accordance with the SNF management policy of the country. The silo dry storage system consists of a concrete structure, liner steel plate in the inner cavity, and fuel basket. Because the components of the silo system are exposed to high energy radiation owing to the high radioactivity of SNF inside, the effects of irradiation during long-term storage must be analyzed. To this end, material specimens of each component were manufactured and subjected to irradiation and strength tests, and mechanical characteristics before and after irradiation were examined. Notably, the mechanical characteristics of the main components of the silo system were affected by irradiation during the storage of spent fuel. The test results will be used to evaluate the long-term behavior of silo systems in the future.

ARISING TECHNICAL ISSUES IN THE DEVELOPMENT OF A TRANSPORTATION AND STORAGE SYSTEM OF SPENT NUCLEAR FUEL IN KOREA

  • Yoo, Jeong-Hyoun;Choi, Woo-Seok;Lee, Sang-Hoon;Seo, Ki-Seog
    • Nuclear Engineering and Technology
    • /
    • 제43권5호
    • /
    • pp.413-420
    • /
    • 2011
  • In Korea, although the concept of dry storage system for PWR spent fuels first emerged in the early 1990s, wet storage inside nuclear reactor buildings remains the dominant storage paradigm. Furthermore, as the amount of discharged fuel from nuclear power plants increases, nuclear power plants are confronted with the problem of meeting storage capacity demand. Various measures have been taken to resolve this problem. Dry storage systems along with transportation of spent fuel either on-site or off-site are regarded as the most feasible measure. In order to develop dry storage and transportation system safety analyses, development of design techniques, full scale performance tests, and research on key material degradation should be conducted. This paper deals with two topics, structural analysis methodology to assess cumulative damage to transportation packages and the effects of an aircraft engine crash on a dual purpose cask. These newly emerging issues are selected from among the many technical issues related to the development of transportation and storage systems of spent fuels. In the design process, appropriate analytical methods, procedures, and tools are used in conjunction with a suitably selected test procedure and assumptions such as jet engine simulation for postulated design events and a beyond design basis accident.

FRAPCON analysis of cladding performance during dry storage operations

  • Richmond, David J.;Geelhood, Kenneth J.
    • Nuclear Engineering and Technology
    • /
    • 제50권2호
    • /
    • pp.306-312
    • /
    • 2018
  • There is an increasing need in the United States and around the world to move used nuclear fuel from wet storage in fuel pools to dry storage in casks stored at independent spent fuel storage installations or interim storage sites. Under normal conditions, the Nuclear Regulatory Commission limits cladding temperature to $400^{\circ}C$ for high-burnup (>45 GWd/mtU) fuel, with higher temperatures allowed for low-burnup fuel. An analysis was conducted with FRAPCON-4.0 on three modern fuel designs with three representative used nuclear fuel storage temperature profiles that peaked at $400^{\circ}C$. Results were representative of the majority of US light water reactor fuel. They conservatively showed that hoop stress remains below 90 MPa at the licensing temperature limit. Results also show that the limiting case for hoop stress may not be at the highest rod internal pressure in all cases but will be related to the axial temperature and oxidation profiles of the rods at the end of life and in storage.

Review of Aging Management for Concrete Silo Dry Storage Systems

  • Donghee Lee;Sunghwan Chung;Yongdeog Kim;Taehyung Na
    • 방사성폐기물학회지
    • /
    • 제21권4호
    • /
    • pp.531-541
    • /
    • 2023
  • The Wolsong Nuclear Power Plant (NPP) operates an on-site spent fuel dry storage facility using concrete silo and vertical module systems. This facility must be safely maintained until the spent nuclear fuel (SNF) is transferred to an external interim or final disposal facility, aligning with national policies on spent nuclear fuel management. The concrete silo system, operational since 1992, requires an aging management review for its long-term operation and potential license renewal. This involves comparing aging management programs of different dry storage systems against the U.S. NRC's guidelines for license renewal of spent nuclear fuel dry storage facilities and the U.S. DOE's program for long-term storage. Based on this comparison, a specific aging management program for the silo system was developed. Furthermore, the facility's current practices-periodic checks of surface dose rate, contamination, weld integrity, leakage, surface and groundwater, cumulative dose, and concrete structure-were evaluated for their suitability in managing the silo system's aging. Based on this review, several improvements were proposed.

Effects of Mustard Seed Extract on Physicochemical and Storage Characteristics of Dry-aged Pork Loin Ham

  • Han-Gyeol Cho;Hack-Youn Kim
    • 한국축산식품학회지
    • /
    • 제43권6호
    • /
    • pp.961-974
    • /
    • 2023
  • This study investigated the effects of mustard seed extracts on physicochemical and storage characteristics of dry-aged pork loin ham during the aging period. In experiment 1, antioxidant activity was assessed for mustard seed extracted with varying ethanol concentrations and the results showed high antioxidant activity at 25%, 50%, and 75% ethanol concentrations. In experiment 2, pork loin was treated with mustard seed extracts obtained using different ethanol concentrations: not treated (control), 25% (MS25), 50% (MS50), and 75% (MS75). Physicochemical and storage characteristics of pork loin ham were measured in wk 0, 2, 4, and 6. The pH, aw, CIE b*, thiobarbituric acid reactive substances and volatile basic nitrogen values were lower in treated samples compared to the control (p<0.05). In conclusion, applying mustard seed extracts, particularly MS75, in the dry-aged pork loin ham production process could enhance storage stability and improve color attributes without having negative impacts on product quality.

MAKING THE CASE FOR SAFE STORAGE OF USED NUCLEAR FUEL FOR EXTENDED PERIODS OF TIME: COMBINING NEAR-TERM EXPERIMENTS AND ANALYSES WITH LONGER-TERM CONFIRMATORY DEMONSTRATIONS

  • Sorenson, Ken B.;Hanson, Brady
    • Nuclear Engineering and Technology
    • /
    • 제45권4호
    • /
    • pp.421-426
    • /
    • 2013
  • The need for extended storage of used nuclear fuel is increasing globally as disposition schedules for used fuel are pushed further into the future. This is creating a situation where dry storage of used fuel may need to be extended beyond normal regulatory licensing periods. While it is generally accepted that used fuel in dry storage will remain in a safe condition, there is little data that demonstrate used fuel performance in dry storage environments for long periods of time. This is especially true for high burnup used fuel. This paper discusses a technical approach that defines a process that develops the technical basis for demonstrating the safety of used fuel over extended periods of time.

HEAT REMOVAL TEST USING A HALF SCALE STORAGE CASK

  • Bang, K.S.;Lee, J.C.;Seo, K.S.;Cho, C.H.;Lee, S.J.;Kim, J.M.
    • Nuclear Engineering and Technology
    • /
    • 제39권2호
    • /
    • pp.143-148
    • /
    • 2007
  • Spent nuclear fuel generated at nuclear power plants must be safely stored during interim storage periods. A dry storage cask to safely store the spent nuclear fuel should be able to adequately emit the decay heat from the spent nuclear fuel. Therefore, heat removal tests using a half scale dry storage cask have been performed to estimate the heat transfer characteristics of a dry storage cask under normal, off-normal, and accident conditions. In the normal condition, the heat transfer rate to an ambient atmosphere by convective air through a passive heat removal system reached 83%. Accordingly, the passive heat removal system is designed well and works adequately. In the off-normal condition, the influence of a half blockage in the inlet on the temperature appears minimal. In the accident condition, the temperature rose for 12 hours after the accident, but the temperature rise steadied after 36 hours.