• Title/Summary/Keyword: Dry ice

Search Result 118, Processing Time 0.021 seconds

VOLATILE CONSTITUENTS OF COOKED SQUID (피등어꼴뚜기의 자숙취에 관한 연구)

  • LEE Eung-Ho;KOIZUMI Chiaki;NONAKA Junsaku
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.4
    • /
    • pp.183-188
    • /
    • 1978
  • In this study, gas chromatographic analysis was carried out on volatile constituents of cooked squid for the object of obtaining information on the characteristic flavor of the cooked squid meat. The results obtained are as follows: 1) Methanol was the most effective solvent for the extraction of volatile constituents of squid meat. 2) Twenty five and thirty two peaks were detected from the condensate collected in cold traps which were immersed in ice water and dry ice-acetone, respectively. In these compounds, five kinds of volatile organic acids such as acetic acid, butyric acid, iso-valeric acid, valeric acid, and caproic acid were identified. 3) Eleven peaks were detected from the head space vapor collected in cold trap which is immersed in liquid nitrogen. Volatile amines identified in these components are as follows; methylamine, trimethylamine, dimethylamine, ethylamine, and iso-propylamine.

  • PDF

Comparison of the Impact of an Optimized Ice Cooling Vest and a Paraffin Cooling Vest on Physiological and Perceptual Strain

  • zare, Mansoor;dehghan, Habibollah;yazdanirad, Saeid;khoshakhlagh, Amir hossein
    • Safety and Health at Work
    • /
    • v.10 no.2
    • /
    • pp.219-223
    • /
    • 2019
  • Background: Ice cooling vests can cause tissue damage and have no flexibility. Therefore, these two undesirable properties of ice cooling vest were optimized, and the present study was aimed to compare the impact of the optimized ice cooling vest and a commercial paraffin cooling vest on physiological and perceptual strain under controlled conditions. Methods: For optimizing, hydrogel was used to increase the flexibility and a layer of the ethylene vinyl acetate foam was placed into the inside layer of packs to prevent tissue damage. Then, 15 men with an optimized ice cooling vest, with a commercial paraffin cooling vest, and without a cooling vest performed tests including exercise on a treadmill (speed of 2.8 km/hr and slope of %0) under hot ($40^{\circ}C$) and dry (40 %) condition for 60 min. The physiological strain index and skin temperature were measured every 5 and 15 minutes, respectively. The heat strain score index and perceptual strain index were also assessed every 15 minutes. Results: The mean values of the physiological and perceptual indices differed significantly between exercise with and without cooling vests (P < 0.05). However, the difference of the mean values of the indices except the value of the skin temperature during the exercises with the commercial paraffin cooling vest and the optimized ice cooling vest was not significant (P > 0.05). Conclusions: The optimized ice cooling vest was as effective as the commercial paraffin cooling vest to control the thermal strain. However, ice has a greater latent heat and less production cost.

Study on the Breakdown Performance of Synthetic Polypropylene Laminated Paper for Application of a HTS Cable (고온초전도 케이블의 응용을 위한 PPLP의 절연파괴 특성연구)

  • Kwag, Dong-Soon;Kim, Young-Seok;Kim, Hae-Jong;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.65-68
    • /
    • 2003
  • In this paper, we researched breakdown characteristics of paper/liquid nitrogen composite insulation system for application of a high temperature superconducting cable. And, we have studied the AC breakdown performance of paper/ice composite insulating system immersed in liquid nitrogen. The electric strength in this paper/ice composite system is higher than that of paper/liquid nitrogen system. Furthermore this system shows a self-healing type breakdown behavior. Among the many kinds of liquid to be immersed and frozen to the ice, deionized water gives the highest electric breakdown strength. The paper/ice composite insulation system is thought to be one of good candidate for the electrical insulating system at cryogenic temperature.

  • PDF

Changes in Characteristic Proteins during Chilling of Dressed broilers (Dressed broilers의 냉장중(冷藏中) 특수단백질(特殊蛋白質) 변화(變化))

  • Lee, Young-Choon
    • Applied Biological Chemistry
    • /
    • v.14 no.2
    • /
    • pp.165-169
    • /
    • 1971
  • From both breast and leg muscle of 12 week-old broiler chicken held for aging in slushed ice and dry chilling at $33-35^{\circ}F$., myosin, actomyosin and other nitrogenous fractions were extracted with KCl-phosphate buffer for various periods from 1 hr. to 25 hr. post-mortem. The changes in extractable nitrogen occurred mainly as a result of decrease in extractability of myosin and to some extent, increase in extractability of actomyosin. Changes in stroma, sarcoplasmic and NPN fractions were small. Myosin extractability decreased rapidly during the first 3 hr. post-mortem and then reduced Continuously in both leg muscle and breast muscle during wet chilling. The decrease of myosin extractability in leg muscle was much more than that in breast muscle, and then the extractability increased after 17 hr. post-mortem in dry chilling. Actomyosin was extracted at low consistent level in wet chilling, while it increased considerably after 17 hr. post-mortem in dry chilling. The tendency was similar in both breast and leg muscle.

  • PDF

A Basic Study on the Development of Automatic Line Stripe Removal Using Dry Ice Blaster (드라이아이스 블래스터를 이용한 자동화 차선제거 장비 개발을 위한 기초연구)

  • Koo, Ja-Kyung;Moon, Deuk-Soo;Bernold, Leonhard E.;Lee, Tai-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.800-803
    • /
    • 2008
  • Road is one of the infrastructure facilities, on which lines include various information for guiding a smooth traffic flow. This line marking work is continually removed and re-marked during maintenance. However, some problems exist when the line marking work is conducted. Traditional methods of using grinders and torches have risk of repetitive skill, and workers are exposed directly to the hazardous situations. Moreover, even though the equipment has developed, the line removing work induces environmental contamination and pollution line on the road. Therefore, this study can become one of the eco-friendly cleaning technologies using dry ice blaster equipment, and the new development of equipment will improve method of pavement marking removal. Also, it can introduce innovative automation in construction.

  • PDF

Effect of Irradiation Temperature on Physicochemical and Sensory Properties of Tarakjuk (Milk Porridge) (방사선 조사 온도가 타락죽의 이화학적 및 관능적 품질 특성에 미치는 영향)

  • Han, In-Jun;Song, Beom-Seok;Lee, Ju-Woon;Kim, Jae-Hun;Choi, Kap-Sung;Park, Jeong-Ro;Chun, Soon-Sil
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.9
    • /
    • pp.1307-1313
    • /
    • 2011
  • This study was conducted to evaluate the effects of irradiation temperature on the physicochemical and sensory properties of Tarakjuk, milk porridge. Tarakjuk was gamma-irradiated at different temperatures of $25^{\circ}C$ (in room), $4^{\circ}C$ (in ice), and $-20^{\circ}C$ (in dry ice) at a dose of 10 kGy, and then autoclaved at $120^{\circ}C$ for 15 min for comparison. pH and Hunter's color value of Tarakjuk were not changed by irradiation regardless of the temperature. However, the TBA (2-thiobarbituric acid) value decreased as irradiation temperature was decreased. The viscosity of Tarakjuk irradiated in dry ice was significantly higher than that irradiated at room temperature and in ice (p<0.05). For the sensory evaluation, there were no significant differences in overall acceptability between non-treated Tarakjuk and that irradiated in dry ice. Flavor pattern analysis using an electronic nose with a SAW (surface acoustic wave) sensor determined that the main peaks at retention times 3.88 and 7.34 sec were related with off-flavor induced by irradiation and unique flavor of Tarakjuk, respectively. These results indicated that irradiation at freezing temperature improved quality deterioration of Tarakjuk by gamma irradiation. However, sensory quality of Tarakjuk irradiated at freezing temperature was still lower than that of non-irradiated Tarakjuk. Therefore, further research is needed to improve the quality of Tarakjuk using combined treatment such as addition of antioxidants and vacuum packaging method.

A Study on the Variation of Air Temperature in the Box Containing Dry Ice for Transportation of the Pine Mushroom, Tricholoma matsutake (Ito et Imai) Sing. (드라이아이스를 넣은 송용상자내(松茸箱子內)의 기온변화(氣溫變化)에 관(關)한 연구(硏究))

  • Lee, Ji-Yul;Kim, Hyung-Bae
    • The Korean Journal of Mycology
    • /
    • v.3 no.2
    • /
    • pp.19-23
    • /
    • 1975
  • A study on the variation of the air temperature in the pine mushroom box containing dry ice for the preservation of the freshness of the pine mushroom, Tricholoma matsutake (Ito et Imai) Sing. produced in Korea was made in Seoul, Korea during the period of August 1 to 30, 1975. A safe shipment of 5 kg (net weight) of fresh mushrooms with freshness preserved for 24 hours in August required the placement of 4.5 kg of dry ice-a half in the upper portion and the other half in the middle portion-in an airtight container (mushroom box). The container used for the shipment test, made of 3mm-thick double-layer cardboard, was of the dimensions : $0.33{\times}0.4{\times}0.5=0.066(m^3)$. As the temperature fell, decreased amounts of dry ice were needed : 3 to 2 kg in September and 1.5 to 0.3 kg in October. With this preservation method, large quantities of fresh mushrooms were exported to Tokyo ana Osaka, Japan without damage in the process of transportation.

  • PDF

Genomic DNA Extracted from Ancient Antarctic Glacier Ice for Molecular Analyses on the Indigenous Microbial Communities

  • Lee, Sang-Hoon;Bidle, Kay;Falkowski, Paul;Marchant, David
    • Ocean and Polar Research
    • /
    • v.27 no.2
    • /
    • pp.205-214
    • /
    • 2005
  • From ancient Antarctic glacier ice, we extracted total genomic DNA that was suitable for prokaryotic 16S rDNA gene cloning and sequencing, and bacterial artificial chromosome (BAC) library and end-sequencing. The ice samples were from the Dry Valley region. Age dating by $^{40}Ar/^{39}Ar$ analysis on the volcanic ashes deposited in situ indicated the ice samples are minimum 100,000-300,000 yr (sample DLE) and 8 million years (sample EME) old. Further assay proved the ice survived freeze-thaw cycles or other re-working processes. EME, which was from a small lobe of the basal Taylor glacier, is the oldest known ice on Earth. Microorganisms, preserved frozen in glacier ice and isolated from the rest of the world over a geological time scale, can provide valuable data or insight for the diversity, distribution, survival strategy, and evolutionary relationships to the extant relatives. From the 16S gene cloning study, we detected no PCR amplicons with Archaea-specific primers, however we found many phylotypes belonging to Bacteria divisions, such as Actinobacteria, Acidobacteria, Proteobacteria $({\alpha},\;{\beta},\;and\;{\gamma})$, Firmicutes, and Cytophaga-Flavobacterium-Bacteroid$. BAC cloning and sequencing revealed protein codings highly identical to phenylacetic acid degradation protein paaA, chromosome segregation ATPases, or cold shock protein B of present day bacteria. Throughput sequencing of the BAC clones is underway. Viable and culturable cells were recovered from the DLE sample, and characterized by their 16S rDNA sequences. Further investigation on the survivorship and functional genes from the past should help unveil the evolution of life on Earth, or elsewhere, if any.

Comparative Study of KOMPSAT-1 EOC Images and SSM/I NASA Team Sea Ice Concentration of the Arctic (북극의 KOMPSAT-1 EOC 영상과 SSM/I NASA Team 해빙 면적비의 비교 연구)

  • Han, Hyang-Sun;Lee, Hoon-Yol
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.6
    • /
    • pp.507-520
    • /
    • 2007
  • Satellite passive microwave(PM) sensors have been observing polar sea ice concentration(SIC), ice temperature, and snow depth since 1970s. Among them SIC is playing an important role in the various studies as it is considered the first factor for the monitoring of global climate and environment changes. Verification and correction of PM SIC is essential for this purpose. In this study, we calculated SIC from KOMPSAT-1 EOC images obtained from Arctic sea ice edges from July to August 2005 and compared with SSM/I SIC calculated from NASA Team(NT) algorithm. When we have no consideration of sea ice types, EOC and SSM/I NT SIC showed low correlation coefficient of 0.574. This is because there are differences in spatial resolution and observing time between two sensors, and the temporal and spatial variation of sea ice was high in summer Arctic ice edge. For the verification of SSM/I NT SIC according to sea ice types, we divided sea ice into land-fast ice, pack ice, and drift ice from EOC images, and compared them with SSM/I NT SIC corresponding to each ice type. The concentration of land-fast ice between EOC and SSM/I SIC were calculated very similarly to each other with the mean difference of 0.38%. This is because the temporal and spatial variation of land-fast ice is small, and the snow condition on the ice surface is relatively dry. In case of pack ice, there were lots of ice ridge and new ice that are known to be underestimated by NT algorithm. SSM/I NT SIC were lower than EOC SIC by 19.63% in average. In drift ice, SSM/I NT SIC showed 20.17% higher than EOC SIC in average. The sea ice with high concentration could be included inside the wide IFOV of SSM/I because the drift ice was located near the edge of pack ice. It is also suggested that SSM/I NT SIC overestimated the drift ice covered by wet snow.

Establishment of Low Temperature Environment System Using Polar Environment Performance Test Construction (극지환경성능시험설비를 활용한 저온환경 시스템 구축)

  • Sung, Ki-Young;Han, Seong-Jong;Lee, Jung-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.843-851
    • /
    • 2022
  • This paper was conducted to study the conditions for the manufacture and operation of artificial snow removal and ice-making test facilities so that the test equipment can be tested in a low-temperature environment using the polar environment performance test facility. The polar environment performance test Facility is designed to artificially simulate extreme environments up to -65 ℃, and is a mid-to-large low-temperature environment test facility that can perform performance tests on offshore plant equipment, ships, leisure, and offshore structures. To verify the safety of deck work of ships operating in polar environments, artificial snow removal and artificial ice making devices were manufactured, and we conducted research on various operating environments using these facilities. For the efficient operation of artificial snow and ice making facilities, it is important to continuously supply dry air, and it has been found that installing an additional heater at the tip of the nozzle is effective in preventing freezing.