• 제목/요약/키워드: Drum type

검색결과 210건 처리시간 0.024초

자이로스코프 시스템을 이용한 드럼 세탁기의 진동 저감 연구 (A Study on Reducing Vibration of Washing Machine Using Gyroscope System)

  • 나규성;박영진;박윤식
    • 한국소음진동공학회논문집
    • /
    • 제24권2호
    • /
    • pp.117-122
    • /
    • 2014
  • A novel method to reduce the vibration of drum type washing machine is proposed. Recently, as the capacity of the drum-type washing machine gets expanded and its washing performance is improved, its market share is increasing in the whole world. But, the capacity of washing machine is limited because of door size and built-in washing machine size. The vibration of washing machine is caused by unbalanced cloths in high spining drum, and the displacement of tub is maximized at transient range about 3 Hz(180 rpm). Previous researches were concerned about steady-state vibration in spinning. In this study, concerned about transient vibration and the displacement of tub is decreased by using gyroscope system. Mutibody dynamic model of washing machine include gyroscope is designed and the vibration of tub have been reduced by 44.7 % over original.

발전소 급수펌프 구동용 소형 터빈 제어시스템 소개 (An Introduction to Speed Control System of Small Steam Turbine for Feed Water Supply in Power Plant)

  • 최인규;김종안
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1603-1604
    • /
    • 2007
  • The load of power plants changes every from time to time according to which steam flow of boiler changes. the feed water control is very important for the power plant to be operated in its stability conditions. In case of circulation type boiler, the instability of feed water control leads to instability of drum level control. The higher level of drum water can induce bad quality steam to go into turbine which means the possibility of damage. The lower level of drum water can induce the tubes of boiler water wall to be overheated. In case of once through type boiler, the instability of feed water control leads to bad cooling of superheaters. The less the feed water flow is, the more heated the superheater is. It is necessary for the turbine driving feed water pump to be controlled for the optimal feed water flow in the large capacity power plant. The speed of turbine is controled for the feed water flow. By the way, the optimal control of steam valve is necessary for the speed control of turbine. Therefore, the various kinds of the steam valve structures are introduced in this paper

  • PDF

돌발성 이벤트 형태의 고장 시뮬레이션을 위한 화력발전소 보일러 드럼 수위 제어 계통의 다이나믹스 모델링 및 운전 시뮬레이션 (Dynamics Modeling and Operation Simulation for the Simulation of Abrupt Faults in the Boiler Drum Level Control System of a Fossile Power Plant)

  • 김정근;김재화;장태규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권2호
    • /
    • pp.59-68
    • /
    • 2002
  • This Paper presents the dynmics modeling and the operation simulation of the 500 MW drum-type boiler and its control system hosted in the Boryung Power Plant unit #1 and #2. The fidelity of the modeling and the operation simulation is well verified by their agreement with the actual data obtained form the plant operation. As a plant signal generator for the various operation patterns and fault situations, the simulation environment will be utilized to develope the fault detecting signal processing algorithms.

세탁에 의한 편성물 내의의 변형 (Changes of Knitted Underwear by Repeated Launderings)

  • 정혜원;나영주
    • 한국의류학회지
    • /
    • 제23권5호
    • /
    • pp.737-744
    • /
    • 1999
  • Underwear made of plain and 1$\times$1 rib-knit cotton fabric were laundered to evaluate the change of the size and the tensile properties. For laundering pulsator and drum washers were used. After 30 washing cycles the amount of shrinkage and the extension were different with washer types. Underwear laundered by the drum type was shrunken in the neck line armhole line and hem line were extended and the bodice width and side length were shrunken,. Tensile strength of the knitted fabric was not decreased through repeated washings because the fabric density was increased. But it was confirmed by SEM that the surface of the fiber was damaged by washings.

  • PDF

신호흐름도 모델을 이용한 화력 발전소 드럼형 보일러 시뮬레이터의 개발에 관한 연구 (A Study on the Development of Drum-Type Boiler Simulator for Thermal Power Plant Using the Signal Flow Diagram Model)

  • 김재선;황동환;김병국
    • 대한전기학회논문지
    • /
    • 제39권12호
    • /
    • pp.1269-1280
    • /
    • 1990
  • Owing to the need to accommodate the load variation, thermal power plants need a modern controller in order to achieve better frequency regulation, faster response and higher efficiency. For a successful development of the digital instrumentation and control system that can adopt advanced control algorithms, power plant simulator must be available for safe and convenient test. In this paper, a simple drum-type boiler model is proposed using Signal Flow Diagram that describes the system by a combination of basic time responses representing the relationships between cause and effect process variables. After verifying the model and thereafter building a simulator based on the proposed model, we tested the operation of the controller and stability or efficiency of the implemented control algorithms.

  • PDF

드럼세탁기 화재안전성 확보를 위한 실험연구 (A Experimental Study on the Fire Safety of Drum-type Electric Washing Machine)

  • 홍성호;이상현;박상태;유현종;전웅재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.131-133
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

  • PDF

전문가 지식을 이용한 화력 발전소 드럼형 보일러 PI 제어기의 자동 동조에 관한 연구 (Expert knowledge-based auto-tuning of PI controllers for a drum-type boiler of fossil power plant)

  • 권만준;황동환;변증남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.219-225
    • /
    • 1991
  • The characteristics of a power plant changes as it operates for a long time and/or for different operating points. As a result, operators must retune gains of the controllers for better performance. In fact, skilled operators can retune the gains in reference to recorded data obtained by a test called dynamic test. The dynamic test, however, requires much time, and can be heavy burden for operators. In this paper, an expert knowledge-based auto-tuner is designed for drum-type boiler controllers of a fossil power plant using fuzzy logic. The performance of the proposed auto-tuner is shown via computer simulation and the simulation results show that the proposed auto-tuner is satisfactory for the desired performance.

  • PDF

퍼지 논리를 이용한 드럼형 보일러의 자동기동에 관한 연구 (A Study on the Automatic Start-up of a Drum-type Boiler Using Fuzzy Logic)

  • 류형근;이재혁;황동환
    • 전자공학회논문지B
    • /
    • 제30B권2호
    • /
    • pp.87-96
    • /
    • 1993
  • Because of the complexity, nonlinearity and long-time delay of power plant, the star-up operation of a fossil power plant is very difficult to automate. So the start-up operation is always carried out by the skilled human operators, who utilize their knowledges and experiences for the predesigned start-up schedules and procedures. In this paper, a fuzzy logic controller is designed for the start-up operation of the power plant. And the operators experiences are modeled in terms of fuzzy sets and variables. To validate the controller, a drum-type boiler of the Seoul Power Plant is constructed via the signal flow diagram. Using the model, the suggested automatic start-up operation is verified, and the results are also presented.

  • PDF

신호 흐름도 모델을 이용한 드럼형 보일러 시뮬레이터의 개발에 관한 연구 (A study on the development of drum-type boiler simulator using the signal-flow diagram model)

  • 김재선;황동환;김병국;변증남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.194-199
    • /
    • 1990
  • Because of being operated to accomodate the load variation, fossile power plants need modern controller to satisfy frequency regulation, fast response and efficiency requirement. But in the way of developing the Digital Instrumentation and Control System that can adopt advanced control algorithms, power plant simulator must be available for safe and convenient test. In this paper, a simple drum-type boiler model is proposed, using Signal Flow Diagram that describes the system by a collection of basic time response representing the relationship between process variables. After verifying the model and thereafter building simulator based on the proposed model, we test the operation of controller and approve stability or efficiency of implemented control algorithms.

  • PDF

건조일체형 드럼세탁기의 화재위험성에 관한 실험연구 (A Experimental Study on the Fire Hazards in Drum-Type Electric Washing Machine)

  • 홍성호
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.328-331
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.