• 제목/요약/키워드: Driving Duty

검색결과 165건 처리시간 0.028초

Dynamic analysis of multi-functional maintenance platform based on Newton-Euler method and improved virtual work principle

  • Li, Dongyi;Lu, Kun;Cheng, Yong;Zhao, Wenlong;Yang, Songzhu;Zhang, Yu;Li, Junwei;Shi, Shanshuang
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2630-2637
    • /
    • 2020
  • The structure design of divertor Multi-Functional Maintenance Platform (MFMP) actuated by hydraulic system for China Fusion Engineering Test Reactor (CFETR) was introduced in this paper. The model of MFMP was established according to maintenance requirements. In this paper, Newton-Euler method and the improved virtual work principle were used, the equivalent driving force of each actuator was obtained through the equivalent Jacobian inverse matrix derived from velocity relationship among the components. The accuracy of the model was verified by ADAMS simulation. The stability control of the heavy-duty components driven by hydraulic cylinders based on Newton-Euler method and improved virtual work principle was established.

자력소호 가스차단부의 소호특성 (Arc-Extinguishing Characteristics of A Rotary-Arc Gas Circuit Breaker)

  • 신영준;박경엽;송기동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1593-1598
    • /
    • 1994
  • Recently rotary-arc, thermal expansion and their composite interrupters are widely used in the distribution power system because they have lots of advantages in making the larger interrupting capacity, the smaller size, the lighter weight and the less surge. A model interrupter of rotary-arc type, which has constant stroke and thermal expansion volume, was studied by varying the design parameters, i.e. the number of turns of the driving coil, the inner diameter of the moving contact, the gas pressure and the shape of the fixed contact for this project. Short cicuit current interrupting tests were conducted to the model interrupters by varying the requirements from 42% to 175% of the test voltage, interrupting current and transient recovery voltage for the test duty No.4 of 7.2kV 12.5kA single phase test. The pressure rise, minimum and maximum arcing times were analyzed for each model interrupter. All types of model interrupters showed good interrupting performances and sufficient design margins for the ratings.

  • PDF

비례제어밸브용 디지털 앰프.컨트롤러에 대한 연구 (A Study on a Digital Amplifier.Controller for Proportional Control Valve)

  • 이재천;고재욱;권태황;신행봉
    • 유공압시스템학회논문집
    • /
    • 제8권1호
    • /
    • pp.19-25
    • /
    • 2011
  • This study presents the design of digital amplifier.controller for a proportional control valve and the development of PID discrete control scheme by using RCP(Rapid Controller Prototyping) system. RCP system is the device to embed the control code developed in PC into the microcontroller on-site. Ramp input test using the digital amplifier.controller developed in this study was carried out for the proportional control valve of domestic production and Bosch Rexroth respectively. The instability problem occurred around maximum displacement of localized valve spool at ramp input test was solved by supplementing offset current to the duty ratio of PWM(Pulse Width Modulation) driving signal to the solenoid. The comparison of test results between localized proportional control valve and Bosch Rexroth's product shows that the characteristics obtained by ramp input test and static flow gains are alike each other. Two valves are about the same in dead bands and hysteresis characteristics.

Design and Implementation of LED Dimming System with Intelligent Sensor Module

  • Cho, Young Seek;Kwon, Jaerock;Kim, Hwan-Yong
    • Journal of information and communication convergence engineering
    • /
    • 제11권4호
    • /
    • pp.247-252
    • /
    • 2013
  • An intelligent light emitting diode (LED) dimming system is designed and implemented for energy-saving lighting systems. An LED light bulb is powered by an LED driver controlled by a microcontroller using pulse width modulation (PWM) signals. By changing the duty cycle of the PWM signals, the LED driver generates a driving current of up to 1,000 mA. The current consumption by the LED light bulb exhibits a very linear characteristic that indicates that the level of LED dimming can be finely tuned. Multiple sensors-lighting intensity and ultrasonic range sensors-are combined with the LED dimming system to realize an automatically controllable LED lighting system. The light intensity sensor is capable of sensing ambient light. The ultrasonic range sensor can detect objects from 0.15 to 5.6 m at a resolution of 0.0254 m. The collected information by the light intensity and ultrasonic range sensors is processed by the microcontroller that in turn automatically controls the brightness of the LED light bulb. The algorithm of the software for the LED dimming system is also described.

Ultra High Luminance and Luminous Efficacy MFFL (Mercury-free Flat Fluorescent Lamp) for Scanning Backlights of LCD TVs

  • Seo, In-Woo;Jung, Jae-Chul;Oh, Byung-Joo;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.231-234
    • /
    • 2009
  • In order to realize the high luminance and luminous efficacy MFFLs for LCD backlights, we optimized the phosphor profile to enlarge the surface area. The MFFL with the new phosphor profile shows a very wide luminance range from 2,600 to 17,000 nit with the corresponding luminous efficacy from 66 to 32.5 lm/W. The results were obtained with the color coordinate of the phosphor to be around (0.25, 0.23). And the single cell is expanded into a multi-structured configuration to realize a 32 inch-sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive local dimming and scanning drive using dual auxiliary electrodes and bipolar drive scheme. Especially the ultra high luminance and luminous efficacy results suggest the duty time of illumination of the backlight unit can be significantly reduced.

  • PDF

직접전단시험모델에 의한 뿌리말뚝의 탄소성조인트 유한요소해석 (Elasto-plastic Joint Finite Element Analysis of Root-pile Using the Direct Shear Test Model)

  • 한중근
    • 한국환경복원기술학회지
    • /
    • 제5권4호
    • /
    • pp.19-30
    • /
    • 2002
  • The stability of slope using root-pile like to the reinforcements is affected by the interaction behavior mechanism of soil-reinforcements. Through the studying on the interaction in joint of its, therefore, the control roles can be find out in installed slope. In study, the stress level ratio based on the insert angle of installed reinforcements in soil used to numerical analysis, which was results from the duty direct shear test in Lab. The maximum shear strain variation on the reinforcements was observed at insert angle, which was approximately similar to the calculated angle based on the equation proposed by the Jewell. The elasto-plastic joint model on the contact area of soil-reinforcements was presumed, the reinforced soil assumed non-linear elastic model and the reinforcements supposed elastic model, respectively. The finite element analysis of assumed models was performed. The shear strain variation of non-reinforced state obtained by the FEM analysis including elasto-plastic joint elements were shown the rationality of general limit equilibrium analysis for the slope failure mode on driving zone and resistance zone, which based on the stress level step according to failure ratio. Through the variation of shear strain for the variation of inserting angle of reinforcements, the different mechanism on the bending and the shear resistance of reinforcements was shown fair possibility.

Design and Analysis of Universal Power Converter for Hybrid Solar and Thermoelectric Generators

  • Sathiyanathan, M.;Jaganathan, S.;Josephine, R.L.
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.220-233
    • /
    • 2019
  • This work aims to study and analyze the various operating modes of universal power converter which is powered by solar and thermoelectric generators. The proposed converter is operated in a DC-DC (buck or boost mode) and DC-AC (single phase) inverter with high efficiency. DC power sources, such as solar photovoltaic (SPV) panels, thermoelectric generators (TEGs), and Li-ion battery, are selected as input to the proposed converter according to the nominal output voltage available/generated by these sources. The mode of selection and output power regulation are achieved via control of the metal-oxide semiconductor field-effect transistor (MOSFET) switches in the converter through the modified stepped perturb and observe (MSPO) algorithm. The MSPO duty cycle control algorithm effectively converts the unregulated DC power from the SPV/TEG into regulated DC for storing energy in a Li-ion battery or directly driving a DC load. In this work, the proposed power sources and converter are mathematically modelled using the Scilab-Xcos Simulink tool. The hardware prototype is designed for 200 W rating with a dsPIC30F4011 digital controller. The various output parameters, such as voltage ripple, current ripple, switching losses, and converter efficiency, are analyzed, and the proposed converter with a control circuit operates the converter closely at 97% efficiency.

CNC 복합자동선반 베이스 구조 안전성에 관한 연구 (A Study of Structural Stability of Complex CNC Automatic Lathe Base)

  • 이상협;양동호;차승환;곽진;이종찬;이영식
    • 한국기계가공학회지
    • /
    • 제20권8호
    • /
    • pp.80-85
    • /
    • 2021
  • This study is to evaluate the structural stability of heavy duty structure of the Complex CNC automatic lathe. The analysis conditions were analyzed by applying the weight and load of the part itself and then applying the weight of the upper assembly unit. As a result of the structural analysis, the values of stress and strain are small and safety factor is high, and as a result of the dynamic analysis, there will be no resonance outside the equipment driving area, so there will be no problem in equipment stability.

향상된 장애물 극복형 실내 이·승강 전동휠체어의 설계 및 제작 (Design and Manufacture of Improved Obstacle-Overcoming type Indoor Moving and Lifting Electric Wheelchair)

  • 김영필;함헌주;홍성희;고석철
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.851-860
    • /
    • 2020
  • 인구 고령화와 건강 복지에 대한 사회적 관심이 높아지면서 재활복지기를 포함한 실버 및 헬스케어 산업과 관련한 연구들이 활발하게 진행되고 있다. 본 연구에서는 기존에 1차적으로 설계·제작되었던 이·승강 전동휠체어를 사용자 측면에서 보다 더 안전성과 편의성을 갖도록 개선하고자 하였다. 사용자 체형을 고려한 헤드레스트 높이조절 기능의 시트 디자인, 사용성 증대를 위한 암레스트의 길이조절 및 95° 회전 기능, 사용자 탑승 편의성을 위한 바닥까지의 시트하강 및 운행 시 승강할 수 있는 기능, 캐스터 회전반경 및 안전성 증대를 위한 발판 추가 및 풋레스트 길이 조절 기능, 승·하강 시 흔들림 방지를 위한 프레임 및 승·하강 링크 설계 등을 개선시켰다. 또한 안전주행을 위한 컨트롤러 및 드라이브 부문과 사용자 편의성 측면의 기능들을 추가적으로 설계·제작하였다. 추가 기능을 보완하여 제작된 실내 전동휠체어의 동작 상태를 평가하기 위해 구동 실험을 수행하였다. 연속 주행시간, 회전반경, 승·하강 최대 하중, 최대 승강 높이, 소음레벨, 운행 보조센서 센싱 최소거리, 서버 및 앱 프로그램 상호연동 및 기기호환성, 듀티 사이클 최대 오차율의 성능실험을 수행하였다. 실험 결과, 더 개선하여 설계·제작한 전동휠체어는 시험 목표 값을 달성하였으며, 성공적으로 동작하는 것을 확인할 수 있었다. 향후 연구로는 개선하여 제작된 이·승강 전동휠체어에 대해 사용자 측면에서의 사용성 평가를 수행할 것이다.

사전-정합 로드-풀 측정을 통한 X-대역 40 W급 펄스 구동 GaN HEMT 전력증폭기 설계 (Design of X-band 40 W Pulse-Driven GaN HEMT Power Amplifier Using Load-Pull Measurement with Pre-matched Fixture)

  • 정해창;오현석;염경환;진형석;박종설;장호기;김보균
    • 한국전자파학회논문지
    • /
    • 제22권11호
    • /
    • pp.1034-1046
    • /
    • 2011
  • 본 논문에서는 X-대역에서 GaN HEMT 소자의 로드-풀 측정을 통한 40 W급 전력증폭기 모듈의 설계, 제작을 보였다. 전력증폭기의 설계에 적용하기 위한 능동 소자로, 최근 발표된 TriQuint사의 GaN HEMT 소자를 선정하였다. 로드-풀 측정 시스템의 임피던스 튜너의 임피던스 범위 제한으로 인하여, 시험치구 내에 사전-정합 회로를 구성하였다. 사전-정합 회로가 포함된 로드-풀 측정을 통해 최적 입 출력 임피던스를 도출하기 위하여, 사전-정합 회로의 2-포트 S-파라미터가 필요하며, 이의 새로운 추출 방법을 제안하였다. 이와 같이 결정된 사전-정합 회로의 S-파라미터를 반영한 로드-풀 측정을 통해 도출된 최적 입 출력 임피던스는 데이터 시트와 근접한 결과를 주며, 이를 통해 측정의 타당성을 확인하였다. 전력증폭기의 정합 회로는 도출된 최적 임피던스로부터 EM co-simulation을 이용하여 설계하였다. 제작된 전력증폭기는 15${\times}$17.8 $mm^2$으로 소형의 크기를 가지며, 10 usec의 펄스 폭, 10 % duty의 펄스 입력 및 드레인 스위칭 상태에서, 9~9.5 GHz 대역 내 출력은 46.7~46.3 dBm, 전력 이득은 8.7~8.3 dB, 효율은 약 35 %의 특성을 보인다.