• Title/Summary/Keyword: Drinking water quality

Search Result 582, Processing Time 0.027 seconds

Survey of Citizens Public Opinion for Natural Spring Water in Seoul (서울지역 약수터에 대한 시민 여론 조사)

  • Kim, Kwang-Rae;Gil, Hae-Kyung;Lee, Man-Ho;Eom, Seok-Won;Lee, Jai-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.2
    • /
    • pp.1-5
    • /
    • 2011
  • We surveyed the citizens opinion about springs in Seoul for two years from 2008 to 2009. It was found that spring water was mostly used by citizens older than 50, and that 29.5% of citizens used purified tap water as drinking water, 27.2% of them used boiled tap water, 21.1% of them used spring water, and 12.1% of them used bottled water. Citizens who store spring water more than a day are 76.7%. Although many citizens (70.3%) knew that water quality had been tested, 40% of them didn't care about checking the certificate of water quality analysis. Once recognized that the spring water was unfit for drinking exceeded standard of drinking water, 85% of citizens would rather not use the spring water.

Rainwater Quality Variations for the Effective Usage (효율적 우수이용을 위한 초기우수의 수질변화)

  • 이창수;지홍기
    • Journal of Environmental Science International
    • /
    • v.12 no.3
    • /
    • pp.275-279
    • /
    • 2003
  • A water quality analysis of rainwater collected from catchment equipment(2m${\times}$1m) was conducted to determine its suitability for domestic purposes, in this study. As the results of analysis, the pH of rainwater was 6.3${\pm}$0.3, and the turbidity of rainwater was over the 5 times than drinking water guidelines. For the usage of rainwater as the domestic and drinking water, the rainwater is need to treat. The analysis value of BOD was about 3 mg/L and the values of heavy metal as the Pb, Cd, Fe, Mn, Cr$\sub$6/$\^$+/and Cu was satisfied with drinking guidelines. Overall results of analysis support the possibility of rainwater as the domestic and drinking water.

Contamination status of groundwater used as livestock drinking in beef and dairy cattle farms, Korea (국내 소사육농가의 자가용 가축음용수 오염실태 평가조사)

  • Jang, Yangho;Lee, Soojin;Kim, Hyobi;Lee, Jeonghak;Lee, Manho;Gil, Hyekyoung;Choe, Nonghoon
    • Korean Journal of Veterinary Research
    • /
    • v.51 no.1
    • /
    • pp.47-53
    • /
    • 2011
  • In Korea, groundwater is main water source in livestock farms. Most dairy and cattle farms have constructed their own wells for human drinking and livestock farming. However, these private residential wells have not been controlled by government and also there was scant study about livestock drinking water quality. Therefore this study was to monitor of the livestock farms' groundwater quality in Korea. Water samples were collected at 123 dairy and cattle farms and were analysed forty six substances with quality standard for drinking water approved by the Minister of Environment. Seventy eight (63.4%) of 123 samples failed to drinking water stand a test. The most frequent contaminants were nitrate-nitrogen and microbial. 22.8% (n=28) of samples showed nitrate-N concentration of higher than 10 mg/L meant that can't be used drinking water for human and the Nitrate-N concentration analysed in the range of 0.2 to 61.2 mg/L. All of 78 failed to drinking samples had microbial problems, especially 5.7% (n=7) of samples indicated water could be contaminated by feces. Other contaminants detected were zinc and evaporation residue. Especially detected zinc concentration (32 mg/L) was about ten times higher than standard of zinc (3 mg/L). Regression analysis indicated that groundwater pH did not influence to nitrate-N concentration but the hardness and chloride could affect to nitrate-N concentration in the groundwater. Most livestock farms were adjacent to crop farmland in Korea. This could cause contamination of groundwater with nitrate-N and pesticide that could accumulate livestock product. Moreover Heavy metal such as zinc and copper could be released from a corrosive plated water pipe in livestock farm. Put together, Korea livestock system is indoor, not pasture-based, hence livestock could be exposed to potential contaminated water consistently. Therefore on the basis of these data, appropriate livestock drinking water quality standards should be prepared to keep livestock healthy and their product safe. Further, livestock drinking water quality should be monitored continuously in suitable livestock drinking water standards.

The Regulations and Guidelines for Management of Corrosive Water and Pipe Corrosion in Drinking Water Distribution System in North America (상수원 관망 부식 제어를 위한 부식성 수질 관리: 북미지역 관리 사례 및 국외 현황)

  • Kim, Minhee;Hyun, Seunghun;Lee, Won-Seok;Loretta, Y. Li
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.359-369
    • /
    • 2017
  • Water distribution systems supply drinking water to consumers' taps. Internal corrosion of metallic pipe used in drinking water distribution systems has reduced water quality and led to increased levels of toxic heavy metals such as lead, copper and nickel. These problems have been experienced to varying degrees by water utilities in many countries. North America has successfully managed and controlled pipe corrosion and corrosive water in water distribution system based on various policies, regulations and rules. Practical and engineering guidelines for evaluation of pipe corrosion and determination of treatment options are also provided to assist drinking water supplies. In addition, the corrosion mechanism in water distribution systems, such as the complex effects of physical and chemical parameters on the corrosion pipes has been improved to accurately predict corrosion rates of metallic pipes in actual water distribution systems. This paper reviews various regulations, policy statement, and treatment produces on controlling corrosion in drinking water distribution systems in US and Canada and then offers suggestion for management of corrosive water and pipe corrosion in drinking water distribution system in Korea.

Water Quality Characteristics and Influencing Factors of Park Drinking Fountains (공원 음수대의 수질 특성 및 영향인자 연구)

  • Sang-jo Kwon;Eun-ah Kim;Duk-hee Joh;Hyo-Jin Lee;Seung-gyu Jung;Seung-yeon Cho
    • Journal of Korean Society on Water Environment
    • /
    • v.40 no.5
    • /
    • pp.229-242
    • /
    • 2024
  • This study investigated water quality characteristics and influencing factors of park drinking fountains having directly piped water systems by analyzing stagnation water (first draw) and water after a 10-minute flush (flushed water). First draws exhibited significant variations in residual chlorine, heavy metals, bacteria, and turbidity, which were largely influenced by usage frequency and external environmental contamination. However, water quality stabilized after flushing. A seasonal analysis indicated that the greatest difference in residual chlorine between first draws and flushed water occurred in spring, followed by that in winter when drinking fountains were discontinued, accompanied by increased zinc concentrations in stagnation water. A comparative analysis of water quality variability by faucet type revealed that push-button faucets exhibited greater variabilities in copper, zinc, and nickel levels than screw-down faucets, likely due to corrosive by-products generated from water hammer effects. Additionally, an analysis based on exterior material indicated that metal fountains experienced higher temperature increases and elevated zinc concentrations in first draws than stone fountains. Regarding installation environments, drinking fountains exposed to direct sunlight or partial shade had higher concentrations of copper, zinc, and nickel in first draws than those installed in constant shade. Overall, these findings suggest that frequent use or flushing can help maintain stable water quality with the exception of push-button faucets.

Water Quality Assessment of Major Drinking Waters in Natural Parks (자연공원내 주요 음용수의 수질환경평가)

  • Yi, Youngkyoung;Yi, Pyongin;Hong, Sungchul
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.439-453
    • /
    • 2018
  • The purpose of this study is to evaluate water quality characteristics of main drinking waters in natural parks, for providing the basic information of water quality and to propose the appropriate management method. to maintain the water quality standards. As a result of the analysis, microorganisms were mostly detected in the nature of natural park. And some sites are currently using UV sterilizer and ozone treatment, and it is considered appropriate to extend the use to other main drinking water. It is also good to boil drinking water at home. Turbidity is expected to improve through environmental cleanup. Overall, the main drinking water in the natural park is suitable for water quality standards, and it is considered that maintenance such as cleaning is necessary.

Risk Assessment of Drinking Water Pollutants (다중이용시설에서의 먹는물 위해성 평가)

  • Back, Young Maan;Chung, Yong;Park, Je Chul;Kim, Hyung Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1107-1108
    • /
    • 2006
  • As expanding municipal and industrial areas since started the economic development plan in earnest in 1970's, the water resource, mainly river surface water has been seriously polluted. Nevertheless, being upgraded in their treatment technologies for the drinking water, the safety has been issued one of crucially social problem in Korea. The water authorities has tried to improve the quality such as amending the drinking water quality standard to be monitored; hazardous chemicals and microorganis have been added and now 55 items, before 47 items, since in 2002. The Water Authorities of Seoul, the capital city of Korea, planned to assess the safty of drinking water quality after amended the standard. This study was conducted to assess the risk due to polluted chemicals including 21 heavy metals, VOCs, pesticides, PAHs, DBPs and organic chemicals among the regulated items. The risk assessment were undertaken hazard identification, exposure assessment, dose-response assessment and risk characterization. For the exposoure assessment, tap water, bottled water and purified water were sampled and analyzed in February, 2004. Risk characterization of detected chemicals was categorized into carcinogenecity and noncarcinogenecity, and estimated the excess of carcinogens and compapared with the reference dose (RfD) of noncarcinogenns. The excess risk of carcinogens from samples were considered comparatively in the acceptable levels; $10^{-6}$ for cancer risk and hazard quotient (HQ) 1.0 for noncancer risk. The deteced levels were estimated in $10^{-5}{\sim}10^{-6}$ of cancer risk and below 1.0 of HQ of noncancer risk. While three kinds of water were determined within the acceptal levels, DBPs were detected in tap water and purified were and some undesireable chemicals such as more fluoride detected rather than the quality stanadard. For the drinking water safety, it shoud be continuously monitored, assessed and managed as well risk communiction between the authoritis and public.

Hygienic Quality of Drinking Water Served in Restaurants and Quality Characteristics of Drinking Water Boiled with Various Plant Materials (외식업소 음용수의 위생실태와 침출재료에 따른 기호성과 저장성)

  • Ahan, Yu-Bok;Jeong, Eun-Ju;Lee, Shin-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.3
    • /
    • pp.159-164
    • /
    • 2007
  • The viable cell of 60% drinking water among 25 drinking water served in restaurant of Daegu district showed above 100 CFU/mL which is sanitary standard of drinking water. The 50 CEO of restaurant considered drinking water served in their own restaurant as just safe and were very deficient in aware of sanitation about drinking water. Sensory quality of drinking water boiled with plant materials, such as barley, Cassia semen, corn, Buckwheat, Korean solomon's seal, Chamomile, Brown rice-green and peppermint was improved in color, taste, flavor and overall acceptability compare to marketed drinking water, respectively. Especially drinking water boiled with Korean solomon's seal was the best In overall acceptability. The number of total bacteria reached above $10^2 CFU/mL$ in marketed drinking water after 4 days storage at 10. But the growth of microorganism did not occur in boiled drinking water with Brown rice-green tea, Korean solomon's seal, barley, Cassia semen and com during storage for 10 days at $10^{\circ}C$, respectively. The number of total bacteria reached above $10^2 CFU/mL$ in marketed drinking water after storage for 1 days at $25^{\circ}C$. The growth of microorganism was accelerated in boiled drinking water with corn, Korean solomon's seal, barley, Cassia semen except Brown rice-green tea during storage far 10 days at $25^{\circ}C$, respectively.

Evaluation of Corrosion Index by Water Quality Parameters in Korea (국내 수질에 적합한 부식성지수 선정 연구)

  • Ahn, Kyunghee;Yu, Soonju;Park, Sujeong;Kwon, Ohsang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.615-623
    • /
    • 2012
  • In this study, we evaluate the corrosion indexes (CI) such as Langelier Index (LI), Larson ratio (LR), Ryznar saturation index (RSI), Aggressiveness index (AI) of water quality for raw water, treated water and water in distribution reservoir at major eight drinking water treatment plants (DWTPs) in Korea. By analyzing secondary contamination of tap water, the variation of secondary contaminants was investigated with regard to pipe materials, aging and corrosion index (CI). In addition, we suggested an appropriate CI applicable water quality and the management plan for CI monitoriing. All CI showed corrosive water quality, and they did not change significantly in the distribution network. However, Copper (Cu), iron (Fe) and zinc (Zn) concentrations as secondary contaminants increased through the distribution network. Among CI, LI was most sensitive to changes in raw water quality and drinking water treatment. Also, it has high correlations with other indexes such as RSI, AI. Therefore, LI is considered as an appropriate CI to the domestic water quality. Based on these result, we propose LI as a drinking water quality standard to control the pipe corrosion from DWTPs.

The Delineation of Water-Pollutant Buffering Zone for Sustaining Better Drinking Water Quality Using a GIS (GIS를 이용한 상수원 보호를 위한 수변구역 지정에 관한 연구)

  • Kim, Kye-Hyun;Yoon, Ho-Seok;Kwon, Woo-Suk
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.3
    • /
    • pp.239-248
    • /
    • 2000
  • The aggravating water quality from the expansion of industrialization along with increasing population lead to develop more intensive physical measures to secure better drinking water quality. This study was mainly initiated to establish a water-pollutant buffering zone for the upper stream basin of Paldang--the major source area of drinking water for the metropolitan Seoul and suburban areas with a population more than 13 million. Two different criteria were considered in determining the buffering distance from the edge of the streamflow : 1km-width buffer zone for the special protection area which has been strictly controlled by the conventional laws for the protection of drinking water supply, and 500m-width buffer zone for the rest of the area. To delineate the exact boundaries of the water-pollutant buffering zone, GIS database was created integrating topography, hydrography, cadastral, and other related layers. The newly designated water-pollutant buffering zone would contribute to improve the water quality in a long term along with the conservation of the wet land. More study, however, should be made within the water-pollutant buffering zone such as the detailed survey of the pollutants, vegetation, and ecosystem for more effective management of the buffering zone.

  • PDF