• Title/Summary/Keyword: Double-tee slab

Search Result 16, Processing Time 0.024 seconds

Continuity for Double Tee Slabs (더블티 슬래브의 연속화)

  • 유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.99-106
    • /
    • 2001
  • The main objective of this study is to develop a continuity of double tee slab with two modified dap-ends to solve the problems of excessive moment, slab depth, deflection, and joint cracking in the original simply supported double tee slab systems. The modified joint is produced in a combination with two slabs with modified dap and one rectangular beam. The modified joint can be justified as following different merits. The span capacity for a design load is increased, while the deflection of the slab is decreased due to the decrease of positive moment at the center span of the slab. The joint cracking between slab and beam, which occur frequently in the original slab systems of double tee will be reduced. No more additional form work is needed to cast topping concrete for continuity. Three point loading tests are performed on the specimens with a variable of an amount of main longitudinal reinforcement to evaluate flexural and shear behavior. Following conclusions are obtained from the experimental investigation. The continuity of double tee slab effectively is provided by placing longitudinal steel reinforcement in the topping concrete over the connection, and generally leads to an increase in span capacity of double tee slabs with reduced deflection. It is more effective to control the initial cracking at the connection than that of some simply supported double tee slab systems.

Shear Test on New Modified Double Tee Slabs including Service Ducts at the Ends (단부에 설비덕트를 포함하는 새로운 더블티 전단실험)

  • Kim Yun Soo;Song Hyung Soo;Ryu Jeong Wook;Lee Bo Kyung;Lee Jung Woo;Yu Sung Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.71-74
    • /
    • 2005
  • The increasement in the floor hight may be one of the most significant problem in the use of precast concrete double slab in the multi-story buildings. The modified double-tees including duct space at the ends of slab were considered in this study. The length and thickness of nib of modified double tee was increased to receive the uniform reaction from rectangular beam, while the original PCI dapped one to receive the point load from inverted tee beam to the leg of double tee. Shear tests were performed on the ends of the modified double tees which were designed by strut-tie model. The modified double tees generally show more ductile flexural failure in the long thickened nib. It is concluded that they show superior failure patterns than that of original dapped one with shear failure.

  • PDF

Evaluation on Flexural Behavior of Double-tee Slabs with the Least Depth from Optimization Process (최적이론에 의하여 설계된 최소 깊이 더블티 슬래브의 휨거동 평가)

  • 유승룡;김대훈;유재천
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.141-152
    • /
    • 1999
  • Precast prestressed double-tee slab may be designed by the PCI Design Handbook. It is based on the bridge construction and is required for reorganization for the use of buildings in the domestic construction environments. Much enhanced sections are developed from the reforming process on the determined design factors in the previous experimental works on double tees. Pre-determined shape, reinforcement detail, and 5000 psi concrete strength can not be expected as the best solution for the domestic construction requirements because large amount of use on that systems are anticipated. Flexural tests are performed on four full-scale 12.5m proto-type models, "least depth double tee", which are resulted from the optimization process. Domestic superimposed live load regulation, domestic material properties which is available to product, building design requirements and economy in construction are considered as the main factors to establish. the first two sections are double tee section for 1.2 ton/$\m^2$ market live load with straight and one-point depressed strands and the second two are for 0.6 ton/$\m^2$ parking live load with those strand types. All of the specimens tested fully comply with the flexural strength requirements as specified by ACI 318-95. However, the research has shown that following improved considerations are needed for better result in practice. The locations and method of connection for the lowest bottom mild bar, connection method between precast and cast-in-place concrete, and dap-end reinforcement are need to be improved.

Shear Test II on New Modified Double Tee Slabs including Service Ducts at the Ends (단부에 설비덕트를 포함하는 새로운 더블티 전단실험II)

  • Kim Yun Soo;Ryu Jeong Wook;Lee Bo Kyung;Yu Sung Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.267-270
    • /
    • 2005
  • The section of double-tee is considered as one of the most efficient type for flexure. However, the depth of it is bigger then that of other slab systems. The story height of it is also increased because the duct space is required under the double tee in addition to their net depth. Thus, a new modified double-tees with the nib length of 1.58m was suggested in this study. The story height of this one is reduced up to 450mm by including duct space under the nib at the ends of slab. The four ends of the modified two single tees were designed by strut-tie models. Shear tests were performed on them to verify the safety. The ultimate shear strengths of non-prestressed two specimens were larger than the design shear strength by strut-tie models. They were failed in ductile with many distributed flexural crackings. However, the other prestressed two specimens showed much stiffer behaviors, less deflection. and strength than those of prestressed.

  • PDF

Crack Control of the Upside of Double Tee Slab and Inversed Tee Beam Joint (더블티 슬래브-역티형 보 접합부 상부의 균열억제를 위한 실험연구)

  • Nam, Sang-Uk;Song, Han-Beom;Yi, Waon-Ho;Yang, Won-Jik;Baik, Young-Soo;Tae, Kyung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.345-348
    • /
    • 2008
  • Recently, demand is caused that new building environment of value added rising demand on the lines of becoming bigger, manhattanize of structure and becoming high standard of structure in a construction site and influx of advanced foreign nation technique. To satisfy these requirements for alternative, structures applied to the PSC, PC is increasing. Double Tee Slab is possible for long length structure and applied to the method of construction. When assembling Double Tee Slab produced by the factory in the field, becamed carry-out topping concrete in upper, but occurred crack to slab line. There is no structural problem to crack occurred in upper, waterproof in maintenance and repair of structure due to a conservative cause several problems.

  • PDF

Effect of the spandrel end beams on shear strength behavior in MTS systems (MTS (Multi-tee slab) 시스템의 테두리보가 전단 강도에 미치는 영향)

  • Kim, Min-Ki;Hong, Sung-Gul;Lee, Jong-Min;Cho, Yi-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.189-192
    • /
    • 2008
  • Most existing double tee systems have need to improve flexure and shear design at their flanges in the section. In order to solve this problem we have devised MTS(Multi-tee slab) system, which is composed of several T-beams and applied spandrel end beams at each slab unit. The application of spandrel end beams has an beneficial effect on the shear strength and force distribution of slab unit because they support the ribs in the transverse direction. Numerical analysis shows that the spandrel end beams increase the shear strength. This paper represents the analysis of shear strength in MTS system and the effect of the spandrel end beams on the system.

  • PDF

Performance Evaluation of Vertical Vibration of Precast Concrete Slabs (프리캐스트 콘크리트 바닥판의 수직진동 허용치 평가)

  • Heo, Seok-Jae;Lee, Sang-Hyun;Cho, Seung-Ho;Chung, Lan;Kim, Sung-Bae;Park, Sung-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.662-667
    • /
    • 2009
  • In this study, the serviceability of Waffle shaped(WAS) and Double-Tee(DT) precast concrete slabs was evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures (a shopping mall in Hanam) of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan), and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and the maximum acceleration level of WAS slabs was lower than that of DT slabs.

  • PDF

Evaluation on Shear Behavior of Double-tee Dap-ends with the Least Depth from Optimization Proces (최적이론에 의하여 설계된 최소 깊이 더블티 댑단부 전단거동 평가)

  • 유승룡;김대훈
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.4
    • /
    • pp.43-54
    • /
    • 1999
  • Shear tests are performed on four full-scale 12.5 m proto-type models, "least depth double tee," which are resulted from the optimization process. Domestic superimposed live load regulation, domestic material properties which is available to product. Korean building code requirements, construction environments and economy are considered as the main factors to establish the process. All of the specimens tested fully comply with the shear strength requirements as specified by ACI 318-95. The research has shown following results. 1) The development length requirement of ACI 318-95 does not seem a good predictor for the estimation of bond failure in a beam with the strands below the supports. 2) The load required for the first initial coner cracking in the dap end and first web shear cracking does not seem to have any relation with the dimension and shear strength of the section in the test beams. 3) The strand slip has a direct relationship with the web shear cracking. However, the coner cracking in the dap end does not give any help for the slip in anchorage. 4) Use of whole area for bearing steel at the bottom of dap end is desired for safe bearing pressure design in the precast prestressed double tee beams. 5) The deflection of beam influences directly on the amount of strand slip at the anchorage after initiation of it, and relationship between them are very linear.