Proceedings of the Korea Concrete Institute Conference (한국콘크리트학회:학술대회논문집)
- 2005.05a
- /
- Pages.71-74
- /
- 2005
Shear Test on New Modified Double Tee Slabs including Service Ducts at the Ends
단부에 설비덕트를 포함하는 새로운 더블티 전단실험
Abstract
The increasement in the floor hight may be one of the most significant problem in the use of precast concrete double slab in the multi-story buildings. The modified double-tees including duct space at the ends of slab were considered in this study. The length and thickness of nib of modified double tee was increased to receive the uniform reaction from rectangular beam, while the original PCI dapped one to receive the point load from inverted tee beam to the leg of double tee. Shear tests were performed on the ends of the modified double tees which were designed by strut-tie model. The modified double tees generally show more ductile flexural failure in the long thickened nib. It is concluded that they show superior failure patterns than that of original dapped one with shear failure.
Keywords