• Title/Summary/Keyword: Double loop controller

Search Result 35, Processing Time 0.023 seconds

A pole assignment control design for single-input double-output nonlinear mechanical systems

  • Kobayashi, Masahito;Tamura, Katsutoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.144-149
    • /
    • 1993
  • This paper discusses a design of a nonlinear control for a class of single-input double-output nonlinear mechanical systems. When conventional linearization methods are applied to the mechanical systems, some problems of oscillation and unstable phenomena arise. The proposed nonlinear control system resolves these problems. In this design the eigenvalues of the closed-loop nonlinear system are assigned to desired locations and local asymptotic stability of the closed-loop system. is guaranteed. The design method is applied to an inverted pendulum system with a moving weight mechanism. Experimental results show that the proposed nonlinear controller is more effective for stability than the usual linear controller.

  • PDF

A Design of a High Performance UPS with Capacitor Current Feedback for Nonlinear Loads (비선형 부하에서 커패시터 전류 궤환을 통한 고성능 UPS 설계)

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.71-78
    • /
    • 2012
  • This paper presents a digital control solution to process capacitor current feedback of high performance single-phase UPS for non-linear loads. In all UPS the goal is to maintain the desired output voltage waveform and RMS value over all unknown load conditions and transient response. The proposed UPS uses instantaneous load voltage and filter capacitor current feedback, which is based on the double regulation loop such as the outer voltage control loop and inner current control loop. The proposed DSP-based digital-controlled PWM inverter system has fast dynamic response and low total harmonic distortion (THD) for nonlinear load. The control system was implemented on a 32bit Floating-point DSP controller TMS320C32 and tested on a 5[KVA] IGBT based inverter switching at 11[Khz]. The validity of the proposed scheme is investigated through simulation and experimental results.

A Modular UPS Design with an Active Multiple Interphase Reactor and Double PLL Control (능동 다중인터페이스 리액터와 Double PLL제어를 이용한 Modular UPS 설계)

  • 박인덕;정상식;안형회;김시경
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.489-497
    • /
    • 2001
  • The proposed dobule phase locked loop and active multiple interphase reactor are used to eliminate the circular current and the voltage ripples caused by the system parameter unbalance of parallel connected UPSs. In this paper, digital controller for the dobule PLL and active interphase reactor is implemented with ADSP21061 as an aspect of functional convenience.

  • PDF

Design of Double Digital Controller to Improve Performance for the Silent Discharging Ozonizer (무성방전 오조나이저의 성능개선을 위한 2중 디지털 제어기의 설계)

  • Park, Jee-Ho;Kim, Dong-Wan;Woo, Sung-Hoon;Roh, In-Bae;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.13-20
    • /
    • 2006
  • In this paper, a control method of ozone generator for a tiny deodorizer is proposed, and also a cooling technique is described which is cooling down the flowing air gap into a silent discharger to $2[^{\circ}C]$ to generate ozone of high density and diffusing power. As the digital control system for this method, a double feedback loop is designed which detects the voltage and current of equivalent capacitor of the discharger and compensates for the poor power waveform caused by the noise at high discharging frequency. During the plant modeling of this system, computing time factor is considered as a unique parameter of the power system to improve the respond characteristics with regard to fluctuating load and to replenish the computing time delay of the controller. Through the experiment, sinusoidal input current for discharger can be acquired and all the effectiveness of this accurate control system over unstable ozone discharger are proved.

Hybrid position/force controller design of the robot manipulator using neural network (신경 회로망을 이용한 로보트 매니퓰레이터의 Hybrid 위치/힘 제어기의 설계)

  • 조현찬;전홍태;이홍기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.24-29
    • /
    • 1990
  • In this paper ,ie propose a hybrid position/force controller of a robot manipulator using double-layer neural network. Each layer is constructed from inverse dynamics and Jacobian transpose matrix, respectively. The weighting value of each neuron is trained by using a feedback force as an error signal. If the neural networks are sufficiently trained it does not require the feedback-loop with error signals. The effectiveness of the proposed hybrid position/force controller is demonstrated by computer simulation using a PUMA 560 manipulator.

  • PDF

Improvement of Steady State Response Using PI+Double Integral Controller (비례적분+이중적분 제어기를 이용한 정상상태 응답 개선)

  • Jung, Gyu Hong
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.24-31
    • /
    • 2016
  • The performance characteristics of a dynamic control system are evaluated according to the transient and steady-state responses. The transient performance is the controllability of the output for the tracking of the reference or the ability to reduce or reject the effects of unwanted disturbances; alternatively, the steady-state performance is represented by the magnitude of the control error at the steady state. As the effects of the two performances on each other are reciprocal, a controller design that shows a zero steady-state error for the ramp input is uncommon because of the challenge regarding the achievement of an acceptable transient response. This paper proposes a PI+double-integral controller for the elimination of the steady-state error for the ramp input while a sound transient performance is maintained. The control-gain design procedure is described by the second-order response for the step input and the response of the error dynamics for the ramp input. The PI+double-integral controller is designed for the first-order transfer function that is derived from a system identification with the open-loop experiment data of the dc-motor. The simple structure of the proposed controller enables the adoption of a low-end microcontroller for the implementation of a real-time control. The experiment results show that the control performance is as effective as that of the simulation analysis for the operating point of linear system; furthermore, the PI+double-integral controller can be conveniently applied to the control system, which is desirable for the improvement of the steady-state error.

An analysis and control of double chopper DC-DC converter (이중 쵸퍼 DC-DC 컨버터의 해석과 제어)

  • Han, Sang-Wan;Sin, Dong-Hee;Hong, Seok-Gyo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.576-581
    • /
    • 1997
  • DC-DC converter with chopper is seen to have problems, such as, loop instability and degradation of transient response, due to the interaction between input filter and switching regulator. In this paper, the switching regulator consisting of input filter and double chopper is analyzed, and the state space model at continuous current mode and the transfer function between duty ratio of switching pulse and output voltage are derived. The controller in this paper is designed as feedforward(P) and feedback(PI) control scheme to minimize the variation of output voltage, and computer simulation results are presented to show the performance of the proposed controller.

  • PDF

Internal Model Control of UPS Inverter using Resonance Model

  • Park J. H.;Kim D. W.;Kim J. K.;Lee H. W.;Noh T. K.;Woo J. I.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.184-188
    • /
    • 2001
  • In this paper, a new fully digital control method for single-phase UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. The inner current control loop is designed and implemented in the form of internal model control and takes the presence of computational time-delay into account. Therefore, this method provides an overshoot-free reference-to-output response. In the proposed scheme, the outer voltage control loop employing P controller with resonance model implemented by a DSP is introduced. The proposed resonance model has an infinite gain at resonant frequency, and it exhibits a function similar to an integrator for AC component. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been demonstrated by the simulation and experimental results respectively.

  • PDF

Direct Current Control Method Based On One Cycle Controller for Double-Frequency Buck Converters

  • Luo, Quanming;Zhi, Shubo;Lu, Weiguo;Zhou, Luowei
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.410-417
    • /
    • 2012
  • In this paper, a direct current control method based on a one-cycle controller (DCOCC) for double frequency buck converters (DF buck) is proposed. This control method can make the average current through the high frequency and low frequency inductors of a DF buck converter equal. This is similar to the average current control method. However, the design of the loop compensator is much easier when compared with the average current control. Since the average current though the high frequency and low frequency inductors is equivalent, the current stress of the high frequency switches and the switch losses are minimized. Therefore, the efficiency of the DF buck converter is improved. Firstly, the operation principle of DCOCC is described, then the small signal models of a one cycle controller and a DF buck converter are presented based on the state space average method. Eventually, a system block diagram of the DCOCC controlled DF buck is established and the compensator is designed. Finally, simulation and experiment results are given to verify the correction of the theory analysis.

Study of Speed Profile for Dynamic Stability of EOTS (EOTS의 동적 안정성을 위한 속도 프로파일에 대한 연구)

  • Gyu-Chan Lee;Dong-Gi Kwag
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.919-925
    • /
    • 2023
  • Modern drones are equipped with miniaturized mission equipment capable of performing various tasks such as surveillance and reconnaissance. Consequently, these mission equipment are exposed to disturbances like wind loads and motor rotations, which can lead to instability in the operation of the Electro-Optical Targeting System (EOTS). Specifically, simple step inputs for changing the line of sight in EOTS can cause abrupt changes in speed, inducing overshoot and potentially creating instability along with other disturbances. To address this, a velocity profile was designed so that the angular velocity moves in a trapezoidal shape when changing the EOTS line of sight. A Double-loop controller was designed to apply this profile as an input to the external loop receiving position feedback. The system's stability was then compared, and the velocity profile was optimized within a stable range by varying maximum speed and acceleration.