• Title/Summary/Keyword: Double line

Search Result 774, Processing Time 0.034 seconds

Luminous efficiency of ZnS:Sm,F TFEL devices (ZnS:Sm,F 형광체 박막 EL 소자의 발광효율)

  • 최광호;임영민;이철준;장보현
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.111-116
    • /
    • 1992
  • ZnS:Sm, F TFEL devices with double insulating layer are prepared by e-beam evaporation method. Electroluminescence and luminous efficiency of the device fabricated at various conditions are investigated. The main transitions on the emission spectra for ZnS:Sm, F TFEL device occur at$^4G_{5/2}\to^6H_{9/2}^4G_{5/2}\to^6H_{7/2}, \;^4G_{5/2}\to^6H_{5/2}\to$.Among them, the dominant spectral line and its corresponding transition occur at $^4G_{5/2}\to^6H_{9/2}$(650 nm) and results in an orange-red emission color. The optimum concentration and substrate temperature for the ZnS:Sm, F TFEL device are around 1 wt% and $200^{\circ}C$. Luminous efficiency for the device is the largest at optimum condition.

  • PDF

Improved Contact property in low temperature process via Ultrathin Al2O3 layer (Al2O3 층을 이용한 저온공정에서의 산화물 기반 트랜지스터 컨택 특성 향상)

  • Jeong, Seong-Hyeon;Sin, Dae-Yeong;Jo, Hyeong-Gyun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.55-55
    • /
    • 2018
  • Recently, amorphous oxides such as InGaZnO (IGZO) and InZnO (IZO) as a channel layer of an oxide TFT have been attracted by advantages such as high mobility, good uniformity, and high transparency. In order to apply such an amorphous oxide TFTs to a display, the stability in various environments must be ensured. In the InGaZnO which has been studied in the past, Ga elements act as a suppressor of oxygen vacancy and result in a decreased mobility at the same time. Previous studies have been showed that the InZnO, which does not contain Ga, can achieve high mobility, but has relatively poor stability under various instability environments. In this study, the TFTs using $IZO/Al_2O_3$ double layer structure were studied. The introduction of an $Al_2O_3$ interlayer between source/drain and channel causes superior electrical characteristics and electrical stability as well as reduced contact resistance with optimally perfect ohmic contact. For the IZO and $Al_2O_3$ bilayer structures, the IZO 30nm IZO channels were prepared at $Ar:O_2=30:1$ by sputtering and the $Al_2O_3$ interlayer were depostied with various thickness by ALD at $150^{\circ}C$. The optimal sample exhibits considerably good TFT performance with $V_{th}$ of -3.3V and field effect mobility of $19.25cm^2/Vs$, and reduced $V_{th}$ shift under positive bias stress stability, compared to conventional IZO TFT. The enhanced TFT performances are closely related to the nice ohmic contact properties coming from the defect passivation of the IZO surface inducing charge traps, and we will provide the detail mechanism and model via electrical analysis and transmission line method.

  • PDF

Stability Analysis of Highway Tunnel and Railway Tunnel According to Section Shape (단면형상 차이에 따른 고속도로 터널과 철도터널의 안정성 분석)

  • Kim, Jae-Kyoung;Lee, Bum-Jun;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.107-115
    • /
    • 2009
  • The number of railway tunnel design is increasing recently compare to a great number of highway tunnel design which had increased with a lot of highway construction in the 70's and 80's. Therefore, there is more or less difference of time between highway tunnel and railway tunnel. In this paper, numerical analysis on two kinds of tunnels, such as two-forked road highway ventilation tunnel and double track railway tunnel with 4.3m of center line, in cases of with support materials condition and without support materials condition were conducted. Finally, stability of two kinds of tunnels were compared and analyzed through comparing of principal stresses and deviator stresses in the near base rock of tunnels using results of numerical analysis.

A Case Study on the Cause and Reinforcement of Railroad Facilities Settlement According to the Ground Excavation (지반굴착에 따른 철도시설물의 침하 원인 및 보강 사례연구)

  • Oh, Beyung-Sam
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.10
    • /
    • pp.85-94
    • /
    • 2012
  • Recent development trend of construction projects in the urban area is the efficient use of insufficient land, however caused to difficult construction conditions because of many adjacent structures. This paper presents the case study that analyzed the ground settlement of railroad structure for the double track railway project of Gyeongui line, adjacent to the high rise building under ground excavating for substructure work, considering interaction of soft ground characteristics. Field survey and measurement works were carried out during construction of station and excavation of high rise building, and field data were analyzed to find the source of settlement of platform and railway. In addition, the soil reinforcement and foundation restoration were performed using in-situ injection method, i.e., D-ROG(Digitalized Restoring On Grout) method which filled the pore of bottom and around of foundation with micro-cement.

CAD Data Conversion to a Node-Relation Structure for 3D Sub-Unit Topological Representation (3차원 위상구조 생성을 위한 노드 - 관계구조로의 CAD 자료 변환)

  • Stevens Mark;Choi Jin-Mu
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.2 s.113
    • /
    • pp.188-194
    • /
    • 2006
  • Three-dimensional topological data is essential for 3D modeling and application such as emergency management and 3D network analysis. This paper reviewed current 3D topological data model and developed a method to construct 3D topological node-relation data structure from 2D computer aided design (CAD) data. The method needed two steps with medial axis-transformation and topological node-relation algorithms. Using a medial-axis transformation algorithm, the first step is to extract skeleton from wall data that was drawn polygon or double line in a CAD data. The second step is to build a topological node-relation structure by converting rooms to nodes and the relations between rooms to links. So, links represent adjacency and connectivity between nodes (rooms). As a result, with the conversion method 3D topological data for micro-level sub-unit of each building can be easily constructed from CAD data that are commonly used to design a building as a blueprint.

Mössbauer Studies on Magnetoresistance in Chalcogenide Fe0.9M0.1Cr2S4 (M=Co, Ni, Zn) (Chalcogenide Fe0.9M0.1Cr2S4(M=Co, Ni, Zn)의 자기저항에 관한 Mössbauer 분광연구)

  • Park, Jae Yun;Lee, Byoung-Seob
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.2
    • /
    • pp.43-48
    • /
    • 2013
  • The Jahn-Teller distortion of chalcogenide $Fe_{0.9}M_{0.1}Cr_2S_4$ (M=Co, Ni, Zn) have been investigated by M$\ddot{o}$ssbauer spectroscopy. The crystal structures of $Fe_{0.9}M_{0.1}Cr_2S_4$ (M=Co, Ni, Zn) are cubic spinel at room temperature. Magnetoresistance measurements indicate these system is conducting-semiconducting transistion around $T_C$. Below $T_C$, the asymmetric line broadening is observed and considered to be dynamic Jahn-Teller distortion. Isomer shift value of the samples at room temperature was about 0.5 mm/s, which means that charge state of Fe ions is ferrous in character. The Ni substitutions for Fe occur to increase the Jahn-Teller relaxation. CMR properties could be explained with magnetic polaron due to Jahn-Teller effect, which is different from both the double exchange interactions of manganite system and the triple exchange interactions of chalcogenide $Cu_xFe_{1-x}Cr_2S_4$.

Nonlinear Magneto-optic Effect in the Paraffin Coated Rb Vapor Cell (파라핀이 코팅된 Rb 증기 셀에서 비선형 광자기 효과 신호)

  • Lee, Hyun-Joon;Yu, Ye-Jin;Bae, In-Ho;Moon, Han-Seb
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.4
    • /
    • pp.249-254
    • /
    • 2009
  • In our study, the Hanle spectrum and nonlinear magneto-optic effect (NMOE) signals were observed as a function of magnetic field on $D_1$ line of $^{87}Rb$ atoms contained in a paraffin coated vapor cell. We observed the double structure from the Hanle and the NMOE spectrum in the paraffin coated Rb vapor cell. The narrow spectral width of the narrow resonance signal is approximately 1 kHz and the magnitude is approximately 10 percent of the total spectrum. Also, the NMOE signals corresponding to the Hanle configuration consisted of two different dispersion-like features. At the near zero magnetic field, a sharp slope signal was centered, and its value was 10 mV/${\mu}T$ with laser power was $200{\mu}W$.

Improved Corrosion and Abrasion Resistance of Organic-Inorganic Composite Coated Electro-galvanized Steels for Digital TV Panels

  • Jo, Du-Hwan;Noh, Sang-Geol;Park, Jong-Tae;Kang, Choon-Ho
    • Corrosion Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.213-217
    • /
    • 2015
  • Recently, household electronic industries require environmentally-friendly and highly functional steels in order to enhance the quality of human life. Customers especially require both excellent corrosion and abrasion resistant anti-fingerprint steels for digital TV panels. Thus POSCO has developed new functional electro-galvanized steels, which have double coated layers with organic-inorganic composites on the zinc surface of the steel for usage as the bottom chassis panel of TVs. The inorganic solution for the bottom layer consists of inorganic phosphate, magnesium, and zirconium compounds with a small amount of epoxy binder, and affords both improved adhesion properties by chemical conversion reactions and corrosion resistance due to a self-healing effect. The composite solution for the top layer was prepared by fine dispersion of organic-inorganic ingredients that consist of a urethane modified polyacrylate polymer, hardener, silica sol and a titanium complex inhibitor in aqueous media. Both composite solutions were coated on the steel surface by using a roll coater and then cured through an induction furnace in the electro-galvanizing line. New anti-fingerprint steel was evaluated for quality performance through such procedures as the salt spray test for corrosion resistance, tribological test for abrasion resistance, and conductivity test for surface electric conductance regarding to both types of polymer resin and coating weight of composite solution. New composite coated anti-fingerprint steels afford both better corrosion resistance and abrasion properties compared to conventional anti-fingerprint steel that mainly consists of acrylate polymers. Detailed discussions of both composite solutions and experimental results suggest that urethane modifications of acrylate polymers of composite solutions play a key role in enhanced quality performances.

The Kwinana Shoreline Fumigation Experiment in Western Australia, Australia

  • Yoon, I.H.;Sawford, B.L;Manins, P.C.
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1996.04a
    • /
    • pp.22-22
    • /
    • 1996
  • ;The Kwinana Shoreline Fumigation Experiment(KSFE) took place in Fremantle, WA, Australia between 23 January and 8 February, 1995. All measurement systems performed to expectation. The CSIRO DAR(Division of Atmospheric Research) LIDAR measured plume sections from near the Kwinana Power Station(KPS) stacks to up to about 5 km downstream. It also measured boundary layer aerosols and the structure of the boundary layer on some occasions. Both stages A and C of KPS were used as tracers at different times. Radiosonde and double theodolite sounding systems measured temperature, humidity, air pressure and wind structure at the coast(Woodman Point) and at the inland(ALCOA residue dump) site at intervals of roughly two hours. These were supplemented by mid afternoon soundings(radiosonde and single theodolite) by Department of Environmental Protection(DEP) at Swanbourne. The Flinders aircraft measured wind, turbulence and temperature structure of the atmospheric boundary layer, concentrations of $C0_2,\;0_3,\;S0_2\;and\;NO_x$ in the smoke plumes and surface radiation over both land and sea. CSIRO DCET(Division of Coal and Energy Technology) vehicle successfully interceptde many smoke plumes and using a range of tracers will be able to identify the various sources much of the time. Routine data from the DEP and Kwinana Industrial Council(KIC) air quality monitoring networks were also automatically logged. Murdoch University measured surface heat flux at Hope Valldy monitoring station and also at Wattleup monitoring station for the last five days. The heart of the LIDAR system is a Neodymium-doped Yttrium-aluminumgarnet(Nd:Y AG) laser operating at a fundamental wavelength of 1064 nm, with harmonics fo 532 nm and 355 nm. A small fraction of the laser beam is scattered back to the LIDAR, collected by a telescope and detedted by a photomultiplier tube. The intensity of the signal as a function of time is a measure of the particle concentration as a function of distance along the line of the laser shot. The results of nine days special field observations are summarized in detail.etail.

  • PDF

Implementation of Milllimeter-Wave Antennas for Vehicular Radar Applications (차량 레이다용 밀리미터파 안테나 구현)

  • 박건우;배종진;김역식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.1
    • /
    • pp.73-82
    • /
    • 1997
  • This paper discusses the design and implementation of parabola, lens, and $32{\times}8$ rectangular microstrip patch array antennas at 77GHz for vehicular radar applications. The parabola size was $7{\times}10$ cm and the f/D was 0.263. Open waveguide(WR-12) was utilized as the feed antenna. Two types of lens antennas with f/D=0.5 were investigated ; one was a plano-convex and the other was a double-convex. A patch array antenna was designed using a transmission line model and experimented. Comparing the theoretical values with the measured ones for four antennas, the results were agreed well in 3 dB BW and radiation patterns, while the gain of the patch array antenna was degraded as much as -25 dB due to the feed network and microstrip-to-coax-to-waveguide transition losses.

  • PDF