• Title/Summary/Keyword: Double chamber

Search Result 134, Processing Time 0.027 seconds

Study on Combustion Characteristics of Unielement Thrust Chambers with Various Injectors (다종의 동축 스월형 단일 분사기 연소 특성에 관한 실험적 연구)

  • Seonghyeon Seo;Lee, Kwang-Jin;Han, Yeoung-Min;Kim, Seung-Han;Kim, Jong-Gyu;Moon, Il-Yoon;Seol, Woo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.85-94
    • /
    • 2004
  • Experimental study on combustion characteristics of double swirl coaxial injectors has been conducted for the assessment of critical injector design parameters. A reusable, unielement thrust chamber has been fabricated with a water-cooled copper nozzle. Two principal design parameters. a swirl angle and a recess length, have been investigated through hot firing tests for the understanding of their effects on high pressure combustion. Clearly, both parameters considerably affect the combustion efficiency, dynamics and hydraulic characteristics of an injector. Internal mixing of propellants in a recess region increases combustion efficiency along with the increase of a pressure drop required for flowing the same amount of mass flow rates. It is concluded that pressure buildup due to flame can be released by the increase of LOx flow axial momentum or the reduction of a recess length. Dynamic pressure measurements of the thrust chamber show varied dynamic behaviors depending on injector configurations.

Modified Fontan Procedure for Single or Dominant Right Ventricle (우세우심실 또는 우단심실증에서의 변형 Fontan 수술)

  • 백완기
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.310-321
    • /
    • 1991
  • Between April 1986 and September 1990, 34 patients with a single or dominant right ventricle underwent modified Fontan procedure for definite palliation in Seoul National University Children`s Hospital. Their age at operation ranged from 8 months to 14 years [Mean 5.5 years]. The ventricular chamber was solitary and of indeterminate trabecular pattern in 6 patients. 28 patients had posteriorly located rudimentary chamber, all of which were trabecular pouches having no communication with outlet septum. The patterns of atrioventricular connection were common inlet[9], double inlet [11], left atrioventricular valve atresia [12] and right atrioventricular valve atresia with L-loop [2]. Pulmonary outflow tracts were atretic in 7 patients and stenotic in 26 patients. Major associated anomalies included anomalous systemic venous drainage [15], dextrocardia [12] and total anomalous pulmonary venous connection[3]. Shunt operations were previously performed in 13 patients and pulmonary artery banding and atrial septectomy in 1 patients. Surgery included intraatrial baffling in 26 patients, bidirectional cavopulmonary shunt in 13 patients, atrioventricular valve obliteration in 3 patients and atrioventricular valve replacement in 3 patients. Central venous pressure measured postoperatively at intensive care unit ranged from 18cm H2O to 28cm H2O [mean 23.2cm H2O]. Hospital mortality was 35.3% [12/34], all died out of low output syndrome. Suspected causes of low output syndrome include ventricular dysfunction [8], hypoplastic or tortuous pulmonary artery [2] and elevated pulmonary vascular resistance [2]. 19 patients had 31 major complications including low output syndrome [18], arrhythmia [4], acute renal failure [3] and respiratory failure [3]. Mortality rate was significantly higher in the groups receiving intraatrial baffling and AV valve replacement respectively [p<0.05]. 20 patients were followed up postoperatively with the mean follow-up period 15.0$\pm$11.6 months. There were no late death and follow-up catheterization was performed in 10 patients. Mean right atrial pressure was 15.4$\pm$6.8mmHg and ventricular contraction was reasonable in all but one case. Thus, Fontan principle can be applied successfully to all the patients with complex cardiac anomaly of single ventricle variety and better results can be anticipated with judicious selection of patient and improvement of postoperative care.

  • PDF

Aerosol Jet Deposition of $CuInS_2$ Thin Films

  • Fan, Rong;Kong, Seon-Mi;Kim, Dong-Chan;Chung, Chee-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.159-159
    • /
    • 2011
  • Among the semiconductor ternary compounds in the I-III-$VI_2$ series, $CulnS_2$ ($CulnSe_2$) are one of the promising materials for photovoltaic applications because of the suitability of their electrical and optical properties. The $CuInS_2$ thin film is one of I-III-$VI_2$ type semiconductors, which crystallizes in the chalcopyrite structure. Its direct band gap of 1.5 eV, high absorption coefficient and environmental viewpoint that $CuInS_2$ does not contain any toxic constituents make it suitable for terrestrial photovoltaic applications. A variety of techniques have been applied to deposit $CuInS_2$ thin films, such as single/double source evaporation, coevaporation, rf sputtering, chemical vapor deposition and chemical spray pyrolysis. This is the first report that $CuInS_2$ thin films have been prepared by Aerosol Jet Deposition (AJD) technique which is a novel and attractive method because thin films with high deposition rate can be grown at very low cost. In this study, $CuInS_2$ thin films have been prepared by Aerosol Jet Deposition (AJD) method which employs a nozzle expansion. The mixed fluid is expanded through the nozzle into the chamber evacuated in a lower pressure to deposit $CuInS_2$ films on Mo coated glass substrate. In this AJD system, the characteristics of $CuInS_2$ films are dependent on various deposition parameters, such as compositional ratio of precursor solution, flow rate of carrier gas, stagnation pressure, substrate temperature, nozzle shape, nozzle size and chamber pressure, etc. In this report, $CuInS_2$ thin films are deposited using the deposition parameters such as the compositional ratio of the precursor solution and the substrate temperature. The deposited $CuInS_2$ thin films will be analyzed in terms of deposition rate, crystal structure, and optical properties.

  • PDF

Experimental Investigation for Evaluating Wave Forces on Perforated Caisson with Two Wave Chambers (유수실이 2개인 유공케이슨의 파력 산정에 관한 실험적 연구)

  • Oh, Sang-Ho;Ji, Chang-Hwan;Lee, Dal Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.6
    • /
    • pp.443-451
    • /
    • 2015
  • Design formula for estimating the wave loading on the perforated caisson having two wave chambers is yet available. In this study, the analysis results are presented with the experimental data for the wave force acting on such a breakwater model. Based on the experimental results, it was able to clarify the variation of wave action according to five different wave phases that are associated with peak wave loading at the three vertical walls. Then the force adjustment factor for double-chamber caisson was estimated, similarly as Takahashi and Shimosako (1994), which needs to be further validated with subsequent experiments and practical application in the field.

Development of two-component polyurethane metering system for in-mold coating (인몰드 코팅을 위한 2액형 폴리우레탄 공급장치 개발)

  • Seo, Bong-Hyun;Lee, Ho-Sang
    • Design & Manufacturing
    • /
    • v.10 no.2
    • /
    • pp.18-23
    • /
    • 2016
  • Injection molded thermoplastic parts may need to be coated to facilitate paint adhesion, or to satisfy other surface property requirements, such as appearance, durability, and weather resistance. In this paper, a two-component polyurethane metering system was developed for the simultaneous injection and surface coating of a plastic substrate. The system was composed of storage tanks, feed pumps, axial piston pumps, mixing head. The tank was designed to be double-jacket structured and fabricated for polyol and isocyanate, respectively. A temperature chamber was used to maintain the material temperature to be $80^{\circ}C$ during flowing from storage tank to mixing head. Inside the chamber, feed pump, low pressure filter, high pressure pump, high pressure filter, pressure sensor, flow meter were installed. A mixing head of L-type was used for homogeneous mixing of polyol and isocyanate. Inside the mixing head, a cartridge heater and a temperature sensor were installed to control the temperature of the materials. The flow rate of axial-piston pump was controlled by using closed-loop feedback control algorithm. The input flow-rates were compared with the measured values. The output error was 6.7% for open-loop control, whereas the error was below 2.2% for closed-loop control. In addition, the pressure generated through mixing-head nozzle increased with increasing flow rate. It was found that the pressure drop between metering pump and mixing-head nozzle was almost 10 bar.

Coronal tooth discoloration induced by regenerative endodontic treatment using different scaffolds and intracanal coronal barriers: a 6-month ex vivo study

  • Shokouhinejad, Noushin;Razmi, Hassan;Farbod, Maryam;Alikhasi, Marzieh;Camilleri, Josette
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.25.1-25.10
    • /
    • 2019
  • Objective: The aim of this study was to evaluate discoloration of teeth undergoing regenerative endodontic procedures (REPs) using blood clot or platelet-rich fibrin (PRF) as the scaffolds and different calcium silicate-based materials as the intracanal coronal barriers in an ex vivo model. Materials and Methods: Forty-eight bovine incisors were prepared and disinfected using 1 mg/mL double antibiotic paste (DAP). The specimens were then randomly divided into 2 groups (n = 24) according to the scaffolds (blood or PRF). After placement of scaffolds each group was divided into 2 subgroups (n = 12) according to the intracanal coronal barriers (ProRoot MTA or Biodentine). The pulp chamber walls were sealed with dentin bonding agent before placement of DAP and before placement of scaffolds. The color changes (${\Delta}E$) were measured at different steps. The data were analyzed using 2-way analysis of variance. Results: Coronal discoloration induced by DAP was not clinically perceptible (${\Delta}E{\leq}3.3$). Regarding the type of the scaffold, coronal discoloration was significantly higher in blood groups compared with PRF groups at the end of REP and after 1 month (p < 0.05). However, no significant difference was found between PRF and blood clot after 6 months (p > 0.05). Considering the type of intracanal coronal barrier, no significant difference existed between ProRoot MTA and Biodentine (p > 0.05). Conclusions: With sealing the dentinal tubules of pulp chamber with a dentin bonding agent and application of DAP as an intracanal medicament, coronal color change of the teeth following the use of PRF and blood sealed with either ProRoot MTA or Biodentine was not different at 6-month follow-up.

A Study on the Development of a Infusion Pump based on an Active Muscle Pump (능동형 근육펌프 구조의 수액 주입 펌프 개발에 관한 연구)

  • Lee, Jeong-Whan;Lee, Sang-Yeob;Lee, Jung-Eun;Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.443-449
    • /
    • 2022
  • In this study, in order to improve the disadvantages of the environmental error of the infusion set that performs infusion therapy in the existing clinical practice and to maximize the user's convenience by miniaturizing the existing infusion pump system, the structure of the muscle pump of the human vein was imitated. As a double check valve method, a method for preventing the backflow of fluid and discharging a constant fluid in one direction by external pressure was proposed. The proposed bio-mimic muscle pump uses a check valve that controls the flow of fluid in one direction and a silicone tube with elasticity, and a chamber is constructed. A peristaltic pump for applying intermittent pressure to the tube chamber was constructed using a multi-cam structure roller. In order to verify the performance of the proposed pump, optimization was performed while changing the number of multi-cam rollers and adjusting the speed of the roller driving motor, and the reproducibility of the instantaneous discharge amount and the continuous discharge amount of the pump was compared and tested. The performance of the muscle pump proposed in this study was verified through experiments that it can inject up to 1L of fluid within 12 hours, and that it is possible to inject the fluid with an accuracy of ±0.1ml. Real-time monitoring of the fluid injection volume through the bio-mimic muscle pump proposed in this study not only increases the convenience of the administrator, but also provides a precise fluid administration environment to more patients at a low cost, and additionally applies bubble detection and occlusion detection technology If so, it is believed that a safer medical environment can be provided to patients.

Optimization of Microbial Electrosynthesis Using Rhodobacter sphaeroides for CO2 Upcycling (CO2 고부가화를 위한 로도박터 스페로이데스를 활용한 미생물 전기합성 최적화 연구)

  • Hui Su Kim;Hwi Jong Jung;Danbee Kim;Samgmin Lee;Jiye Lee;Jin-Suk Lee;Myounghoon Moon;Chang Hyun Ko;Soo Youn Lee
    • New & Renewable Energy
    • /
    • v.19 no.4
    • /
    • pp.20-26
    • /
    • 2023
  • Emitted CO2 is an attractive material for microbial electrochemical CO2 reduction. Microbial electrochemical CO2 reduction (i.e., microbial electrosynthesis, MES) using biocatalysts has advantages compared to conventional CO2 reduction using electrocatalysts. However, MES has several challenges, including electrode performance, biocatalysts, and reactor optimization. In this study, an MES system was investigated for optimizing reactor types, counter electrode materials, and CO2-converting microorganisms to achieve effective CO2 upcycling. In autotrophic cultivation (supplementation of CO2 and H2), CO2 consumption of Rhodobacter sphaeroides was observed to be four times higher than that with heterotrophic cultivation (supplementation of succinic acid). The bacterial growth in an MES reactor with a single-chambered shape was two times higher than that with a double chamber (H-type MES reactor). Moreover, a single-chambered MES reactor equipped with titanium mesh as the counter electrode (anode) showed markedly increased current density in the graphite felt as a working electrode (cathode) compared to that with a graphite felt counter electrode (anode). These results demonstrate that the optimized conditions of a single chamber and titanium mesh for the counter electrode have a positive effect on microbial electrochemical CO2 reduction.

Estimation of Net Biome Production in a Barley-Rice Double Cropping Paddy Field of Gimje, Korea (김제 보리-벼 이모작지에서의 순 생물상생산량의 추정)

  • Shim, Kyo-Moon;Min, Sung-Hyun;Kim, Yong-Seok;Jung, Myung-Pyo;Choi, In-Tae
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.2
    • /
    • pp.173-181
    • /
    • 2015
  • Fluxes of carbon dioxide ($CO_2$) were measured above crop canopy using the Eddy Covariance (EC) method, and emission rate of methane ($CH_4$) was measured using Automatic Open/Close Chamber (AOCC) method during the 2012-2013 barley and rice growing season in a barley-rice double cropping field of Gimje, Korea. The net ecosystem exchange (NEE) of $CO_2$ in the paddy field was analyzed to be affected by crop growth (biomass, LAI, etc.) and environment (air temperature, solar radiation, etc.) factors. On the other hand, the emission rate of $CH_4$ was estimated to be affected by water management (soil condition). NEE of $CO_2$ in barley, rice and fallow period was -100.2, -374.1 and $+41.2g\;C\;m^{-2}$, respectively, and $CH_4$ emission in barley and rice period was 0.2 and $17.3g\;C\;m^{-2}$, respectively. When considering only $CO_2$, the barley-rice double cropping ecosystem was estimated as a carbon sink ($-433.0g\;C\;m^{-2}$). However, after considering the harvested crop biomass ($+600.3g\;C\;m^{-2}$) and $CH_4$ emission ($+17.5g\;C\;m^{-2}$), it turned into a carbon source ($+184.7g\;C\;m^{-2}$).

Comparison of Carbon Budget between Rice-barley Double Cropping and Rice Mono Cropping Field in Gimje, South Korea (국내 벼-보리 이모작지와 벼 단작지의 탄소수지 비교)

  • Shim, Kyo-Moon;Min, Sung-Hyun;Kim, Yong-Seok;Jung, Myung-Pyo;Choi, In-Tae;Kang, Kee-Kyung
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.4
    • /
    • pp.337-347
    • /
    • 2016
  • Carbon dioxide ($CO_2$) and methane ($CH_4$) were measured in a rice-barley double cropping and rice mono cropping paddy fields, which are located in the southwestern coast of Korea, over a one-year period. Net ecosystems $CO_2$ exchange (NEE) and ecosystem respiration (Re) were estimated by the eddy covariance (EC) method, and an automatic open/close chamber (AOCC) method was used to measure $CH_4$ fluxes. Environmental factors (solar radiation, air temperature, precipitation etc.) were also measured along with fluxes. After the quality control and gap-filling, the observed fluxes were analyzed. As a result, NEE was -603.0 and $-471.5g\;C\;m^{-2}\;yr^{-1}$ in rice-barley double cropping and rice mono cropping paddy field, respectively. $CH_4$ emissions increased during the course of flooded days and were similar in two cropping paddy field. Accoding to rough results considering only fluxes of $CO_2$ and $CH_4$, it was estimated that the carbon absorbation in rice-barley double cropping paddy field was higher than that in rice mono cropping paddy field by $128.9g\;C\;m^{-2}\;yr^{-1}$.