• Title/Summary/Keyword: Dose planning

Search Result 718, Processing Time 0.03 seconds

The Feasibility Study on the Monte Carlo Based RTP Commissioning

  • Kang, Sei-Kwon;Cho, Byung-Chul;Park, Suk-Won;Oh, Do-Hoon;Park, Hee-Chul;Bae, Hoon-Sik
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.43-46
    • /
    • 2004
  • The commissioning of a treatment planning system of model-based dose calculation algorithm requires a lot of parameters to be selected to fit measured data, in which process physical insights for the parameters are often forgotten. We present the photon beam commissioning of Pinnacle$^3$ with the help of Monte Carlo (MC) simulation and evaluate the parameters Pinnacle$^3$ demands. Even though the MC calculation produces reasonable values for the commissioning, the thorough physical basis of the Pinnacles$^3$'s commissioning process is needed to use the MC derived parameters directly.

  • PDF

Study on Energy Distribution of the 6 MeV Electron Beam using Gaussian Approximation (가우시안 근사를 이용한 6 MeV 전자선의 에너지분포에 관한 연구)

  • Lee, Jeong-Ok;Kim, Seung-Kon
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.53-56
    • /
    • 1999
  • A Gaussian distribution was parametrized for the initial distribution of the electron beam emitted from a 6MeV medical linear accelerator. A percent depth dose was measured in a water phantom and the corresponding Monte Carlo calculations were performed starting from a Gaussian distribution for a range of standard deviations, ${\sigma}=0.1$, 0.15, 0.2, 0.25, and 0.3 with being the mean value for the Incident beam energy. When measurement and calculation were compared, the calculation with the Gaussian distribution for ${\sigma}=0.25$ turned out to agree best with the measurement. The results from the present work can be utilized as input energy data in planning an electron beam therapy with a Monte Carlo calculation.

  • PDF

Are dental radiographs dangerous? (치과방사선영상 검사는 위험한 술식인가?)

  • Lee, Byung-Do
    • The Journal of the Korean dental association
    • /
    • v.54 no.2
    • /
    • pp.155-162
    • /
    • 2016
  • Radiographs can help in the diagnosis and treatment planning, but the exposure to ionizing radiation may elevate the risk of developing cancer in a person's lifetime. The objective of this review is to briefly summarize 1) radiation risk, especially cancer risks associated with diagnostic imaging, 2) linear, non-threshold (LNT) hypothesis, 3) the risks of radiation exposure to a fetus, and 4) the campaign of Image Gently. The individual risk of radiation-related cancer from any single medical imaging procedure is extremely small and it is not likely to be cancer risk at doses lower than 100 mGy, but patients may be harmed by avoiding diagnostic imaging due to fear of radiation hazard. Dentists need to understand the radiation doses delivered by various radiographic techniques and the acceptable exposure thresholds to effectively advise the patient and to reduce the unnecessary radiation

  • PDF

An Analysis of the Effect of R&D Characteristics of Firms on R&D Performance (연구개발 특성이 기업 연구 성과에 미치는 영향 분석 - 국제화된 한국 중소기업을 중심으로 -)

  • Kim, Han-Joo;Hwang, Yun-Seop
    • International Commerce and Information Review
    • /
    • v.9 no.4
    • /
    • pp.395-413
    • /
    • 2007
  • The main purpose of this study is to analyze the relationships between the R&D characteristics and R&D performance for Korean enterprises. We divided R&D performance into technological and business launching performance and analyzed four R&D characteristics' effect on the performance. The empirical analysis results can be summarized as follows: First, R&D characteristics of enterprises show a strong relationship with R&D performance in the case of R&D process control. Second, firm capability and information routine positively affect to technological performance at 0.1 significant level but not showing significance in the case of business launching performance. Third, managerial support negatively affects to technological performance but dose not show statistical significance. Its effect on business launching performance, however, shows positive and significant effect. This result is expected to be highly suggestive for establishing the effective R&D strategies of enterprises and also the relevant overseas marketing plan to support R&D planning.

  • PDF

Feasibility Test of the Numerical Optimization for the Fast IMRT Planning

  • Cheong, Kwang-Ho;Suh, Tae-Suk;Dempsey, James F.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.79-82
    • /
    • 2005
  • In this study, we have tested the feasibility of the convex non-linear objective model and the line search optimization method for the fluence map optimization (FMO). We've created the convex nonlinear objective function with simple bound constraints and attained the optimal solution using well-known gradient algorithms with an Armijo line search that requires sufficient objective function decrease. The algorithms were applied to 10 head-and-neck cases. The numbers of beamlets were between 900 and 2,100 with a 3 mm isotropic dose grid. Nonlinear optimization methods could efficiently solve the IMRT FMO problem in well under a minute with high quality for clinical cases.

  • PDF

Cone-beam computed tomography: Time to move from ALARA to ALADA

  • Jaju, Prashant P.;Jaju, Sushma P.
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.263-265
    • /
    • 2015
  • Cone-beam computed tomography (CBCT) is routinely recommended for dental diagnosis and treatment planning. CBCT exposes patients to less radiation than does conventional CT. Still, lack of proper education among dentists and specialists is resulting in improper referral for CBCT. In addition, aiming to generate high-quality images, operators may increase the radiation dose, which can expose the patient to unnecessary risk. This letter advocates appropriate radiation dosing during CBCT to the benefit of both patients and dentists, and supports moving from the concept of "as low as reasonably achievable" (ALARA) to "as low as diagnostically acceptable" (ALADA).

Development of RADCON and Establishments of Its Related System

  • Kim, Kuk-Ki;Lee, Kun-Jai;Park, Won jong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.51-56
    • /
    • 1996
  • In a NNP (Nuclear Power Plant) severe accident, radionuclides are dispersed into the air. The official regulatory institute, KINS (Korea Institute of Nuclear Safety), has been authorized and developing Computerized technical Advisory system for the Radiological Emergency preparedness (CARE). In this paper, in line with the CARE system, we presented the result of a modularized intermediate-level emergency dose assessment computer code. The RADCON (RADiological CONsequence analysis) version 3.0, which is operable on PC, is developed for simulating emergency situation by considering continuous washout phenomena, and provide a function of effective emergency planning. The source files are coded by using C language in order to increase the compatibility with the other computer system and modularized to adjust the functions and characteristics of each module fer easy understanding and further modification.

  • PDF

Internal Radiation Dosimetry in Radionuclide Therapy (방사성핵종을 이용한 치료에서 흡수선량의 평가)

  • Kim, Kyeong-Min;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.2
    • /
    • pp.120-126
    • /
    • 2006
  • Radionuclide therapy has been continued for treatment of incurable diseases for past decades. Relevant evaluation of absorbed dose in radionuclide therapy is important to predict treatment output and essential for making treatment planning to prevent unexpected radiation toxicity. Many scientists in the field related with nuclear medicine have made effort to evolve concept and technique for internal radiation dosimetry in this review, basic concept of internal radiation dosimetry is described and recent progress in method for dosimetry is introduced.

Evaluation of CT Number Difference between Radiation Therapeutic CT Simulator and Conventional CT (방사선치료용 CT simulator와 진단용 CT의 구조 차이에 의한 CT number의 비교 평가)

  • Seo, Jeong Min;Rhim, Jae Dong;Kim, Chan Hyeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.3
    • /
    • pp.215-219
    • /
    • 2015
  • The purpose in this study is to investigate CT number difference between conventional CT and CT simulator. It shows good correlation in CT number on the muscle, bone, and air. However, in the liver, lungs and water, the low correlation was detected. This result can become the good index for the direction of the distribution of dose difference research between CT equipment for using the computerized radiation therapy planning system.

New evolution of cone-beam computed tomography in dentistry: Combining digital technologies

  • Jain, Supreet;Choudhary, Kartik;Nagi, Ravleen;Shukla, Stuti;Kaur, Navneet;Grover, Deepak
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.179-190
    • /
    • 2019
  • Panoramic radiographs and computed tomography (CT) play a paramount role in the accurate diagnosis, treatment planning, and prognostic evaluation of various complex dental pathologies. The advent of cone-beam computed tomography (CBCT) has revolutionized the practice of dentistry, and this technique is now considered the gold standard for imaging the oral and maxillofacial area due to its numerous advantages, including reductions in exposure time, radiation dose, and cost in comparison to other imaging modalities. This review highlights the broad use of CBCT in the dentomaxillofacial region, and also focuses on future software advancements that can further optimize CBCT imaging.