Blood flow velocity in the anterior humeral circumflex artery and tear size can predict synovitis severity in patients with rotator cuff tears

  • Takahiro Machida;Takahiko Hirooka;Akihisa Watanabe;Hinako Katayama;Yuki Matsukubo
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.11-17
    • /
    • 2024
  • Background: Rotator cuff tears are often associated with synovitis, but the ability of noninvasive ultrasonography to predict the severity of synovitis remains unclear. We investigated whether ultrasound parameters, namely peak systolic velocity in the anterior humeral circumflex artery and Doppler activity in the glenohumeral joint and subacromial space, reflect synovitis severity. Methods: A total of 54 patients undergoing arthroscopic rotator cuff repair were selected. Doppler ultrasound was used to measure peak systolic velocity in the anterior humeral circumflex artery and Doppler activity in the glenohumeral joint and subacromial space, and these values were compared with the intraoperative synovitis score in univariate and multivariate analyses. Results: Univariate analyses revealed that tear size, peak systolic velocity in the anterior humeral circumflex artery, and Doppler activity in the glenohumeral joint were associated with synovitis in the glenohumeral joint (P=0.02, P<0.001, P=0.02, respectively). In the subacromial space, tear size, peak systolic velocity in the anterior humeral circumflex artery, and Doppler activity in the subacromial space were associated with synovitis severity (P=0.02, P<0.001, P=0.02, respectively). Multivariate analyses indicated that tear size and peak systolic velocity in the anterior humeral circumflex artery were independently associated with synovitis scores in both the glenohumeral joint and the subacromial space (all P<0.05). Conclusions: These findings demonstrate that tear size and peak systolic velocity in the anterior humeral circumflex artery, which can both be measured noninvasively, are useful indicators of synovitis severity.

Value of Ultrasound Elastography in Assessment of Enlarged Cervical Lymph Nodes

  • Teng, Deng-Ke;Wang, Hui;Lin, Yuan-Qiang;Sui, Guo-Qing;Guo, Feng;Sun, Li-Na
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2081-2085
    • /
    • 2012
  • Background: To investigate the value of ultrasound elastography (UE) in the differentiation between benign and malignant enlarged cervical lymph nodes (LNs). Methods: B-mode ultrasound, power Doppler imaging and UE were examined to determine LN characteristics. Two kinds of methods, 4 scores of elastographic classification and a strain ratio (SR) were used to evaluate the ultrasound elastograms. Results: The cutoff point of SR had high utility in differential diagnosis of benign and malignant of cervical lymph nodes, with good sensitivity, specificity and accuracy. Conclusion: UE is an important aid in differential diagnosis of benign and malignant cervical LNs.

A Study on Ultrasound Pulsed Doppler Systems for Sending the Blood Flow (혈류 진단을 위한 초음파 펄스 도플러 시스템에 관한 연구)

  • Kim, Seong-Ryul;Kim, Jin-Ha;Park, Song-Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.5
    • /
    • pp.33-40
    • /
    • 1984
  • In the conventional pulsed doppler system, gated CW is used to excite a ultrasonic transducer so that a group of linear RF amplifiers are required to excite a ultrasonic array transducer in the scanning pulsed doppler system. A pulsed doppler system without linear high voltage RF amplifiers, which excites the transducer impulsively, is studied theoretically and experimentally. In this paper, an experimental 8-channel pulsed doppler system is implemented, which uses quadrature defection to detect the direction of motion and can compensate the attenuation effect. The designed pulsed doppler system shows the possibility of real time multichannel doppler flow meter.

  • PDF

The effects of gingival blood flow on pulpal blood flow detection using ultrasound Doppler flowmetry: animal study

  • Dohyun Kim ;Hyoung-Seok Ko;Soo-Yeon Park ;Seung-Yeon Ryu ;Sung-ho Park
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.9.1-9.11
    • /
    • 2023
  • Objectives: This study evaluated the effect of adjacent gingival blood flow on detection of pulpal blood flow (PBF) using ultrasound Doppler flowmetry (UDF) through animal study. Materials and Methods: The study included 36 right and left maxillary the third incisors and canines in 9 experimental dogs. The study included 2 main steps: In the first step, the pulse sound level (PSL) was recorded on the cervical part of each tooth without flap elevation (Group 1), with flap elevation (Group 2), and after it was repositioned in place (Group 3). In the second step, the PSL was recorded on the cervical part of each tooth (Group 4), after pulpotomy (Group 5), after partial pulp extirpation (Group 6), after complete extirpation (Group 7), and after canal filling (Group 8). In Groups 5-8, the study was performed with and without flap elevation in the left and right teeth, respectively. The PSL was graded as follows: 0, inaudible; 1, heard faintly; and 2, heard well. The difference between each group was analyzed using Friedman's test with Wilcoxon signed-rank tests (α = 0.05). Results: In step 1, the PSL results were Group 1 > 2 and 3. In step 2, there was no significant difference between the groups when the flap was not elevated, while PSL results were Group 4 > 5 ≥ 6 and 7 ≥ 8 when the flap was elevated. Conclusions: PBF is affected by gingival blood flow when measured with UDF. UDF measurements require isolation of gingiva from the tooth.

The Use of Transabdominal Ultrasound in Inflammatory Bowel Disease

  • Jiro Hata;Hiroshi Imamura
    • Korean Journal of Radiology
    • /
    • v.23 no.3
    • /
    • pp.308-321
    • /
    • 2022
  • Transabdominal ultrasound (TAUS) is useful in all aspects of lesion screening, monitoring activity, or treating/diagnosing any related complications of inflammatory bowel disease. Its ability to screen or diagnose complications is almost the same as that of other methods, such as CT or MRI. Moreover, its noninvasiveness makes it a first-line examination method. A TAUS image depicting ulcerative colitis will show large intestinal wall thickening that is continuous from the rectum, which is mainly due to mucosal layer thickening, while for Crohn's disease, a TAUS image is characterized by a diversity in the areas affected, distribution, and layer structure. Indicators of activity monitoring include wall thickness, wall structure, and vascular tests that use Doppler ultrasound or contrast agents. While all of these have been reported to be useful, at this time, no single parameter has been established as superior to others; therefore, a comprehensive evaluation of these parameters is justified. In addition, evaluating the elasticity of lesions using elastography is particularly useful for distinguishing between fibrous and inflammatory stenoses. However, the lack of objectivity is the biggest drawback of using ultrasound. Standardizing and popularizing the ultrasound process will be necessary, including scanning methods, equipment settings, and image analysis.

Detection of Segmental Branch Renal Artery Stenosis by Doppler US: A Case Report

  • Chang Kyu Seong;Seung Hyup Kim;Jung Suk Sim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.57-60
    • /
    • 2001
  • In stenosis of a segmental branch or among multiple renal arteries, Doppler sampling of intrarenal arteries in the upper, mid and lower poles demonstrates strikingly different waveform patterns that might otherwise be overlooked. We report a case of segmental branch renal artery stenosis in which a pulsus parvus et tardus waveform was observed in a segmental branch of a renal artery. In this case, systematic analysis of Doppler waveforms of intrarenal arteries at more than three different locations facilitated a rapid and confident diagnosis of segmental branch renal artery stenosis.

  • PDF

Improvement of Fetal Heart Rate Extraction from Doppler Ultrasound Signal (도플러 초음파 신호에서의 태아 심박 검출 개선)

  • Kwon, Ja Young;Lee, Yu Bin;Cho, Ju Hyun;Lee, Yoo Jin;Choi, Young Deuk;Nam, Ki Chang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.328-334
    • /
    • 2012
  • Continuous fetal heart beat monitoring has assisted clinicians in assuring fetal well-being during antepartum and intrapartum. Fetal heart rate (FHR) is an important parameter of fetal health during pregnancy. The Doppler ultrasound is one of very useful methods that can non-invasively measure FHR. Although it has been commonly used in clinic, inaccurate heart rate reading has not been completely resolved.. The objective of this study is to improve detection algorithm of FHR from Doppler ultrasound signal with simple method. We modified autocorrelation function to enhance signal periodicity and adopted adaptive window size and shifted for data segment to be analysed. The proposed method was applied to real measured data, and it was verified that beat-to-beat FHR estimation result was comparable with the reference fetal ECG data. This simple and effective method is expected to be implemented in the embedded system.

Clinical study on the estimation of blood flow velocity using doppler ultrasound of the cerebral artery in stroke patients (도플러 초음파를 이용한 중풍환자(中風患者)의 뇌혈관(腦血管) 혈류측정(血流測定)에 관한 임상적(臨床的) 연구(硏究) (경동맥(頸動脈), 추골동맥(椎骨動脈) 및 기저동맥(基底動脈)을 중심으로))

  • Chang, In-Su;Sun, Jungn-Ki
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.345-360
    • /
    • 1996
  • Background and Purpose: To evaluate the blood flow velocity using doppler ultrasound of the carotid artery, vertebral artery, and basilar artery in stroke patients Material and Methods: To evaluate the blood flow, I measured the peak systolic velocity and mean velocity of the common carotid artery(CCA), internal carotid artery(ICA), external carotid artery (ECA). vertebral artery(VA), and basilar artery(BA) in 44 stroke patients and 15 healthy adults. To investigate the difference between ischemic stroke patients and normal healthy adults, I selected 44 ischemic stroke patients diagnosed by brain CT and brain MRI, and 15 healthy adults who did not have any symptoms of stroke, hypertension, heart disease, and diabetes melitus. Results: Peak velocity in normal adults was 50.6${\pm}$1.6cm/sec in the CCA, 67.2${\pm}$1.7cm/sec in the ICA, 62.5${\pm}$2.4cm/see in the ECA, 45.5${\pm}$1.9cm/sec VA. and 50.5${\pm}$3.5cm/sec in the BA. Mean velocity in normal adults was 26.9${\pm}$1.1cm/sec in the CCA, 43.7${\pm}$1.4cm/sec in the ICA, 26.7${\pm}$1.3cm/sec in the ECA. 31.6${\pm}$1.9cm/sec in the VA and 33.0${\pm}$2.6cm/sec in the BA. In this study, there was a significant increase in the velocity of ICA, ECA, and VA of ischemic stroke patients in comparison with normal healthy adults. And the blood flow velocity of this study in the CCA and ECA was different from other reported foreign values and the other known values in my country. Conclusion: There was a significant difference in the blood flow velocity between ischemic stroke patients and normal healthy adults. And the blood flow velocity of this study was different from other reported foreign values and the other known values in my country. Therefore, it needs more detailed studies about old aged Korean and ischemic stroke patients than previous studies.

  • PDF

Ultrasonographic Findings of Transitional Cell Carcinoma in a Dog (개에서 방광내 이행세포암종의 초음파학적 진단)

  • 엄기동;오태호;장광호;이영원;장동우;이기창;윤정희
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.268-271
    • /
    • 2002
  • Transitional cell carcinoma(TCC) was identified by cytological and ultrasonographic findings in an 11-year-old, intact female Yorkshire terrier with intermittent hematuria for three years. In color-doppler ultrasound images there was marked irregular wall thickness of the bladder surface and well-defined hyperechoic focal lesions within the mass. Active vascular response was observed in the surroundings of hyperechoic lesions.

The effects of ultrasound and myofascial release therapy on blood velocity of cranial artery in tension-type headache subjects (초음파와 근막이완술이 긴장형 두통환자의 뇌혈류 속도에 미치는 영향)

  • Han Jong-Man;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.196-209
    • /
    • 2003
  • The aim of study was compared with the possible role of cranial artery in headache pathogenesis each 2 group (group I : ultrasound therapy alone, group II : myofascial release therapy alone)- divided each 5 tension- type headache patients. Each group were applied ultrasound therapy for 5 minuets and myofascial release therapy for 15 minuets in occipital portion. The study carried out to determine the effects of ultrasound and myofascial release on the cranial arteries velocity from November 11, 2001 to March 29, 2002 the objects were 10 patients who having the tension-type headache at H-hospital. Transcranial doppler ultrasonograpy(TCD) is new non-invasive applicable method to evaluate flow velocities of intrans cranial and extracranial cerebral arteries. TCD was peformed with standard method to measure the Mean Flow Velocity(MFV) of the middle and posterior cerebral arteries, the vertebral arteries.

  • PDF