• Title/Summary/Keyword: Documentation of society

Search Result 527, Processing Time 0.026 seconds

Environmental Effects and Characteristics of Ground Vibration Caused by Tunnel Blasting in the Vicinity of an Apartment (터널 발파로 인한 아파트 인근지역에서의 지반진동 전파특성 및 영향 평가 연구)

  • 최병희;류창하;백승규
    • Explosives and Blasting
    • /
    • v.22 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Explosive blasting in tunnel excavation produces ground vibration and air blast as its side effects, which may cause complaints from nearby residents. This study was intended to investigate the propagation characteristics of ground vibration induced by tunnel blasting and to evaluate its effects on the residential structures near the site. We have conducted field measurements for 6 blasts and acquired vibration data from 70 measuring points, some of which on positioned inside the tunnel for comparative reason. Various documentation was reviewed to determine an allowable level of peak particle velocity for the residential structures in the area and the allowable limit was set to 0.5 cm/sec. Propagation equations for peak particle velocities were derived from regression analyses using the data acquired at both the surface and the underground tunnel. Finally we proposed appropriate predictive equations for the two areas and a safe blasting criterion.

The Effects of Project-Based Flipped Learning Model on Self-Directed Learning Ability, Self-Leadership and Learning Competency (프로젝트기반 학습의 플립러닝 수업 모형이 자기주도적 학습능력과 셀프리더십 및 학습역량에 미치는 영향)

  • KAN, Jin-Sook;SHIN, Mee-Sook;KWON, Myung-Soon
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.5
    • /
    • pp.1478-1491
    • /
    • 2016
  • This study has designed to find out the effects of a project-based flipped learning model at universities on the self-directed learning ability, the self-leadership, and the learning competency. For the study, two procedures were performed. First, a flipped learning model for a project-based learning was developed on the basis of the literature reviews. The flipped learning model has three different steps: the pre-class, the in-class, and the post-class. In the pre-class, instructors provide mini-core courses using various technologies for learners outside the class. The in-class is the step to check whether learners prepare their learning or not. Also, in this step, the in-death learning and the teaching-learning process by interaction between instructors and learners would be performed. In the post-class, learners would be able to sustain the extended learning to develop the learning tasks and activities after flipped learning class. Through this step, the learners could be experienced integrated thinking and application, documentation and management, as well as sharing and spread of their learning. Second, the effectiveness of the developed flipped learning model on the self-direction, the self-leadership, and the learning competency was examined. The quantitative research method and the qualitative research method were used for this study. The results indicated that the flipped learning model showed improvement on the self-direction, the self-leadership, and the learning competency.

Anterior Cruciate Ligament Reconsruction Using Tibialis Tendon Allograft - A Short-Term Follow-Up Result - (동종 경골건을 이용한 전방 십자 인대 재건술 -단기 추시 결과-)

  • Woo, Jong-Ken;Ko, Sang-Hun;Lew, Sog-u;Park, Moon-Soo;Jung, Kwang-Hwan;Gwak, Chang-Youl;Lee, Chae-Chil;Cho, Sung-Do
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • Purpose: To evaluate the clinical stability and function after arthroscopic anterior cruciate ligament(ACL) reconstruction using fresh-frozen tibialis tendon allograft. Materials and Methods: Of the patients who underwent ACL reconstruction using tibialis tendon allograft from July 2002 to June 2003, thirty-one patients could be evaluated and the mean follow-up period was 19 months. Evaluations included were Lysholm knee score, 2000 International knee Documentation Committee (IKDC) subjective knee score, Lachman test, pivot shift test, KT-1000 arthrometer measurement and 2000 IKDC knee examination. Results: The mean Lysholm score was 88. Twenty-eight patients (90.3%) were good or exellent for the measured parameters. Twenty-seven patients(87.1%) was over 70 in IKDC subjective knee score. Thirty patients (96.8%) had 1+ firm end or negative Lachman test. 27 patients (87.1%) had a negative pivot shift. Thirty patients (96.8%) had less than 5mm difference of maximal manual difference by KT-1000 arthrometer. Twenty -nine patients (93.5%) were nearly normal or normal grade by 2000 IKDC knee examination. Complications were 1 case of failure and 1 case of infection. Conclusion: ACL reconstruction with the double-stranded fresh-frozen tibialis tendon allograft resulted in a reliable and predictable outcome after short-term follow-up.

  • PDF

Comparison and Analyzing System for Protein Tertiary Structure Database expands LOCK (LOCK을 확장한 3차원 단백질 구조비교 및 분석시스템의 설계 및 구현)

  • Jung Kwang Su;Han Yu;Park Sung Hee;Ryu Keun Ho
    • The KIPS Transactions:PartD
    • /
    • v.12D no.2 s.98
    • /
    • pp.247-258
    • /
    • 2005
  • Protein structure is highly related to its function and comparing protein structure is very important to identify structural motif, family and their function. In this paper, we construct an integrated database system which has all the protein structure data and their literature. The structure queries from the web interface are compared with the target structures in database, and the results are shown to the user for future analysis. To constructs this system, we analyze the Flat-File of Protein Data Bank. Then we select the necessary structure data and store as a new formatted data. The literature data related to these structures are stored in a relational database to query the my kinds of data easily In our structure comparison system, the structure of matched pattern and RMSD valure are calculated, then they are showed to the user with their relational documentation data. This system provides the more quick comparison and nice analyzing environment.

Clinical Results of Anatomical Single Bundle Anterior Cruciate Ligament Reconstruction Using Autogenous Quadriceps Tendon (자가 대퇴사두건을 이용한 해부학적 단일 다발 전방십자인대 재건술의 임상적 결과)

  • Park, Jin;Kim, Young Sin;Lee, Ju Hong;Wang, Seong Il;Park, Chan Ill
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the clinical outcomes and stability of anatomical single bundle anterior cruciate ligament reconstruction (SBACLR) with quadriceps tendon comparable to double bundle anterior cruciate ligament reconstruction (DBACLR). Materials and Methods: We retrospectively reviewed 28 consecutive patients (16 male, 12 female) who underwent SBACLR using quadriceps tendon from March 2009 (Group 1) and compared its clinical results to whom DBACLR with semitendinosus tendon for 53 patients (51 male, 2 female) from August. 2006 (Group 2). Mean age were 34.9 (range, 16-52) in Group 1 and 21.6 (range, 17-55) in Group 2. Mean follow up periods were 13.9 months (range, 12-20) in Group 1 and 36.2 months (range, 20-52) in Group 2. Lysholm score, International Knee Documentation Committee (IKDC) evaluation form and Tegner score were performed for evaluating the clinical outcome. Lachman test, pivot shift test and KT-1000 arthrometer (MEDmetric Corp., San Diego, CA, USA) were performed for stability. Results: There was no statistical significant difference between the two groups in terms of Lysholm score (Group 1: $85.9{\pm}2.6$, Group 2: $90.9{\pm}1.0$, P=0.226), IKDC score (P=0.345) and Tegner score (Group 1: $6.9{\pm}1.4$, Group 2: $7.1{\pm}1.3$, P=0.523). Nor was there statistical significance between the two groups in terms of KT-1000 arthrometer (Group 1: $1.5{\pm}1.1\;mm$, Group 2: $1.5{\pm}1.6\;mm$, P=0.457), Lachman test (P=0.547) and pivot shift test (P=0.073). Conclusion: Anatomical SBACLR with quadriceps tendon shows similar clinical outcomes and stability comparable to anatomical DBACLR with hamstring tendon.

  • PDF

Registration and Description of Public Records in Korea : A Comparative Analysis of Korean Recordskeeping System with the International Standards (한국의 기록물 둥록 및 기술에 대한 기록관리적 접근)

  • Si, Kwi-Sun
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.3 no.1
    • /
    • pp.69-92
    • /
    • 2003
  • Registration and description of records are important elements of processing which provide with the background information of production of records and business-related information. They also enable to search and use the records. In this paper, I examined the Korean registration and description system defined in the Public Records Management Act which directs the records creating agency to register records in creating offices and directs the "professional archives" to make "basic registrations" and "detailed registrations" of the records. In the analysis and comparison of two different registration and description systems with the known international standards of records and archives management, such as ISO15489 and ISAD(G), I intended to evaluate the Korean records and archives management system and suggested recommendations for the renovation of the Korean recordskeeping system. Despite we have unique office business procedures and the culture of officialdom, and despite we have developed our system based on the established business procedures and office culture, it would be preferable to adopt or follow the international standards and established best practices. After the comparative analysis, I recommended some innovations in the filed of registration and description. For instance, in the basic registration. we would better to install an item of "simple contents summary." We may also need the multiple-level description. The fonds level description and the series level description should be introduced to our archival automated management system. We need to establish a Korean standard of description adopting the rules of the ISAD(G) and ISAAR(CPF). Essential requirements for electronic records management, such as contextual and structural information, should be incorporated in the new standard. Documentation of records disposition also should be reinforced to guarantee the authenticity of records and to ensure control of the records. To implement the recommendations for the standard, we need to amend the Public Records Management Act and its Regulations and Rules. Also it is imperative to redesign the GARS integrated archival automated management system.

Effects of Knee Position during the Graft Fixation of the Arthroscopic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Graft (이식 건 고정 시 슬관절 위치가 자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 후 결과에 미치는 영향)

  • Lee, Churl-Woo;Yoo, Jae-Doo;Roh, Kwon-Jae;Park, Seong-Pil
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.143-147
    • /
    • 2005
  • Purpose: In case of anterior cruciate ligament (ACL) reconstruction, graft tendon is generally fixed in tibial tunnel with knee extended. When reconstructing ACL using hamstring tendon, the authors aim to find out the effect of knee joint position during graft fixation on postoperative knee joint stability and range of motion. Materials and Methods: Prospective study was done on patients who have undergone ACL reconstruction using hamstring tendon from May 2002 to January 2003 We used Rigifix system (Mitek Product, Johnson and Johnson, USA) and Intrafix system for fixation. Thirty nine patients received ACL reconstruction during this period. Excluding 2 patients lost in the follow-up, 37 patients were analyzed. The mean follow-up period was 14 months $(13{\sim}25months)$. Knee position was decided alternatively without any bias. Clinical evaluation was based on Lachman test, pivot shift test, Lysholm score, IKDC(international knee documentation committee) assessment and side to side KT-1000 maximal manual arthrometer difference. Results: After the last follow-up, average postoperative Lysholm score was 93.1 poins(65-98points). According to IKDC score, 26 cases were normal, 10 cases were nearly normal, 1 case was abnormal and we had no case of severe abnormality. The mean difference from the normal side was 2.5 mm under maximal manual loading KT-1000 arthrometer. According to postoperative Lachman test, 32 cases were normal,2 cases were grade I and 1 case was grade II. There were 34 cases of normal, 2 cases of grade I and 1 case of grade II. When using maximal manual KT-1000 arthrometer side to side difference, the difference from the normal side while fixing the tibia at 20'knee flexion was 2.3 mm and at full extention the difference was 2.7 mm. The range of motion at postoperative 1 year showed 5 degree flexion contracture in 1 case at 20 degrees knee flexion and 10 degrees of flexion limitation was observed in 2 cases at full extension. Conclusion: When ACL reconstruction using autogenous hamstring tendon, anterior laxity showed no difference in its stability between two groups. Tibial side fixation at full extension may be helpful in preventing flexion contracture due to overconstrained graft tendon.

  • PDF

Comparison of Anterior Cruciate Ligament Reconstruction using Autogenous Patellar Tendon versus Quadruple Hamstring Tendon (자가 슬개건과 네 겹 슬괵건을 이용한 전방 십자 인대 재건술의 비교)

  • Kim, Seok-Jung;Kwon, Oh-Soo;Choi, Dong-Won;Song, Ho-Wook;Kang, Hyun-Taek;In, Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.19-25
    • /
    • 2004
  • Purpose: To compare the results of two different autografts used to reconstruct the anterior cruciate ligament(ACL): bone-patellar tendon-bone and quadruple hamstring tendon. Materials and Methods: Forty one cases (20 bone-patellar tendon-bone cases and 21 quadruple hamstring tendon cases) were followed up more than 2 years postoperatively. Patellar tendons were fixed with interference screws and hamstring tendons were fixed with cross pins and intrafix sheaths and screws. Follow-up results were evaluated with KT-2000 arthrometer, International knee Documentation Committee(IKDC) evaluation form and follow up X-ray Donor site morbidity was analysed. Results: Final IKDC) scores more than B grade and side to side differences of manual maximum test using KT-2000 arthrometer showed insignificant differences(p>) between the two groups. Plain radiographs of hamstring group showed marked widening of the femoral and tibial tunnels at postoperative 2 years. Patellar tendon group showed 30% rate of anterior knee complications. Conclusion: ACL reconstruction using autogenous hamstring graft with new fixation method showed comparable clinical results to using autogenous patellar tendon graft with fewer anterior knee symptoms.

  • PDF

Comparison of Single-Incision, Single-Bundle Posterior Cruciate Ligament Reconstruction Using Allograft Tendon (동종건을 이용한 단일 절개, 단일 다발 후방십자인대 재건술의 비교)

  • Kyung, Hee-Soo;Cheon, Sang-Ho;Park, Kyung-Hyun;Jung, Jae-Wook
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.107-113
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the posterior cruciate ligament (PCL) reconstruction with single bundle, single-incision technique using Achilles tendon and tibialis anterior allograft with ligament remnant preservation. Materials and Methods: Twenty six patients underwent PCL reconstruction was included. There were 21 males and 5 females. Mean age was 32 years. Used graft was a fresh frozen Achilles tendon allograft (group I, 14 cases) and tibialis anterior allograft (group II, 12 cases). Arthroscopic PCL reconstruction was performed using transtibial, single-incision and single bundle technique with remnant preserving as possible. For clinical evaluation, range of motion, posterior drawer test, Lysholm score, Tegner activity scale, International Knee Documentation Committee (IKDC) grade and posterior stress radiograph were used. The mean follow-up period was 21.6 months (12-40 months). Associated injuries were 5 medial collateral ligament injuries, which were treated by conservative method. Results: Range of motion (ROM) was returned to normal range in 24 cases, but ROM deficit under $10^{\circ}$ flexion was 2 cases at final follow-up period. Preoperative posterior drawer test was 17 cases in grade II and 9 cases in grade III. At final follow-up 13 cases returned within normal grade, 7 cases grade I and 6 cases grade II posterior instability. Lysholm mean score was improved from preoperatively 62 to 90 at final follow-up period. Tegner activity mean scale improved from preoperatively 3.5 to 5.6 at final follow-up period. IDKC grade was grade A was 3 cases, grade B 17 cases, grade C 6 cases. In posterior stress radiograph, posterior displacement was improved from mean 12 mm preoperative to 4.5 mm at final follow-up. There were no statistical differences between two groups in clinical evaluations. There were two cases of re-rupture of graft at the bone-tendon junction in group I. Conclusion: We had successful results of PCL reconstruction with single-incision, single bundle technique using Achilles and tibialis anterior allograft without difference between two groups in patients with PCL injury. There were more re-rupture of graft in Achilles tendon group.

  • PDF

Posterior Cruciate Ligament Augmentation Using an Autogenous Hamstring Tendon Graft and the Posterior-Posterior Triangulation Technique (만성 단독 후방십자인대 파열에서 자가 슬괵건과 후-후 삼각술기를 이용한 만성 후방십자인대 보강술)

  • Kim, Yeung Jin;Chae, Soo Uk;Choi, Byong San;Kim, Jong Yun;Lee, Hwang Yong;Han, Chang Wan;Han, Su Hyoun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.24-30
    • /
    • 2013
  • Purpose: To evaluate the outcome of arthroscopic posterior cruciate ligament (PCL) augmentation using an autogenous hamstring tendon graft and the posterior-posterior triangulation technique with preservation of ligament remnant or elongated ligament. Materials and Methods: From January 2002 to December 2009, we performed PCL augmentation using an autogenous hamstring tendon graft and the posterior-posterior triangulation technique in 32 patients. The mean age was 35.2 years. Twenty two cases were male and 10 cases were female. Average follow-up period was 5 years and 5 months (range: 2-7.9). Subjective and objective parameters were utilized in analyses, such as the mean range of motion, post. drawer test, Lysholm knee score, Tegner activity score, International Knee Documentation Cominittee (IKDC) grade, and second look arthroscopic examination. Results: At last follow up posterior displacement by the Telos stress test decreased from $10.8{\pm}5.1\;mm$ to $2.8{\pm}3.7\;mm$ (p<0.05). The final Lysholm knee score improved from $60.4{\pm}5.8$ to $84.6{\pm}4.8$. Tegner activity score improved from 3.2 to 4.8. The final IKDC grade was A in 18, B in 11, C in 3. Postoperative Lysholm knee score, IKDC grades, Tegner activity scale, and posterior displacement demonstrated statistically significant improvement compared to the preoperative state (p<0.05). Conclusion: Arthroscopic PCL reconstruction using an autogenous hamstring tendon with preservation of ligament remnant showed a good clinical results and posterior stability.

  • PDF