• Title/Summary/Keyword: Distribution uniformity

Search Result 677, Processing Time 0.037 seconds

A Study of Technology Trends for Effective Process Control under Non-Normal Distribution (비정규분포하에서의 효과적 공정관리를 위한 기술체계동향 연구)

  • Kim, Jong-Gurl;Um, Sang-Joon;Kim, Young-Sub;Ko, Jae-Kyu
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2008.11a
    • /
    • pp.599-610
    • /
    • 2008
  • It is an important and urgent issue to improve process capability in quality control. Process capability refers to the uniformity of the process. The variability in the process is a measure of the uniformity of output. A simple, quantitative way to express process capability, the degree of variability from target in specification is defined by process capability index(PCI). Almost process capability indices are defined under normal distribution. However, these indices can not be applied to the process of non-normal distribution including reliability. We investigate current research on the process of non-normal distribution, and advanced method and technology for developing more reliable and efficient PCI. Finally we suggest the perspective for future study.

  • PDF

Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires (LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo;Han, Won-Tak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.1-7
    • /
    • 2008
  • This study is intended to compare physical properties of fluorescent luminaires with ones of LED luminaires so as to analyze fundamental characteristics of LED luminaires. For this, a comparative analysis of uniformity ratio of illuminance and luminance distribution of these two luminaires was made, and materials for applying LED luminaires to interior construction space were prepared. This study was carried out in four stages. First, a theoretical review on LED illumination light source was made compared with the existing luminaires. Second, a mock-up to control experimental variables to meet the objective of this study was manufactured. Third uniformity ratio of illuminance and luminance distribution of each luminaire were measured by using the mock-up. Fourth, a comparative analysis of uniformity ratio of illuminance and characteristics of luminance distribution of the existing fluorescent luminaires and LED ones was made. As a result of the study, the uniformity ratio of illuminance of LED luminaires, 0.559, was higher than one of the existing fluorescent luminaires, 0.522. Namely, it was shown that illuminance distribution of LED luminaires was uniform and global diffuse was good. As a result of measuring luminance distribution, it was found that luminance distribution of LED luminaires was more uniform than one of the existing fluorescent luminaires. The maximum luminance of fluorescent luminaires and LED luminaires over the wall was $180.6[cd/m^2]$ and $155.26[cd/m^2]$ respectively. Namely, the maximum luminance of fluorescent luminaires was higher than one of LED luminaires. The average luminance of fluorescent luminaires and LED luminaires was $44.32[cd/m^2]$ and $58.65[cd/m^2]$. Like this, the average luminance of LED luminaires was higher than one of fluorescent luminaires. Considering these results, it's thought that LED luminaires can give a person in the room a more comfortable working environment than fluorescent luminaires.

COMPUTATIONAL ANALYSIS FOR IMPROVING UNIFORMITY OF $SNO_2$ THIN FILM DEPOSITION IN AN APCVD SYSTEM ($SnO_2$ 박막증착을 위한 APCVD Reactor 내 유량 균일도 향상에 대한 수치 해석적 연구)

  • Park, J.W.;Yoon, I.R.;Chung, H.S.;Shin, S.W.;Park, S.H.;Kim, H.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.567-570
    • /
    • 2010
  • With continuously increasing flat panel display size, uniformity of thin film deposition has been drawing more attentions and associated fabrication methodologies are being actively investigated. Since the convective flow field of mixture gas plays a significant role for deposition characteristics of thin film in an APCVD system, it is greatly important to maintain uniform distribution and consistent concentration of mixture gas species. In this paper, computational study has been performed for the improvement of flow uniformity of mixture gas in an APCVD reactor during thin film deposition process. A diffuser slit has bee designed to spread the locally concentrated gas flow exiting from the flow distributor. A uniform flow distributor has been developed which has less dependency on operating conditions for global flow uniformity

  • PDF

A Study on the Characteristics of Air flow Fields with Velocity Uniformity in a Wind Tunnel (풍동장치 내 공기 유동장과 속도 균일도 특성에 대한 분석)

  • Han, Seok Jong;Lee, Sang Ho;Lee, Jae Gyu
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.3
    • /
    • pp.59-64
    • /
    • 2018
  • Numerical simulations were carried out to analyze the flow characteristics of the wind tunnel. Flow field characteristics with velocity uniformity at the test sections are largely affected by inlet conditions of air flow rate and temperature. Axial average velocity of the flow field inside the test area was almost linearly decreased by 0.026% each 1m. The uniformity distributions of axial velocity showed the highest reduction rate of about 24% between nozzle outlets 1 ~ 2m. In addition, average velocity and the uniformity are increased with air temperature in the wind tunnel due to density variation. The results of this paper are expected to be useful for the basic design of wind tunnel and to be used for efficient design.

Improvement Scheme of Field Uniformity of Stirrer Parameter in Reverberation Chamber (전자파 잔향실의 교반기 매개변수에 따른 전계 균일도 향상 방안)

  • Kim, Kwang-Yong;Hong, Joo-Il;Han, Seung-Moon;Doo, Jin-Suk;Huh, Chang-Su;Lee, Ki-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1583_1584
    • /
    • 2009
  • Reverberation chamber have become a common tool in radiated susceptibility and emission testing of electronic equipment. In a reverberation chamber, internal electromagnetic fields are mixed by metallic stirrer. Due to elimination of Polarization characteristic in reverberation chamber, electromagnetic wave reached to EUT all aspect angle. Hence, Field distribution in overmode reverberation chamber can be presented by chi-square distribution. Field uniformity in reverberation chamber have to satisfy standard deviation below 3dB and is influenced by mechanical stirrer. This paper investigates relationship between change of stirrer parameter and field uniformity in reverberation chamber.

  • PDF

A Study on Life Expectancy Forecast for Porcelain Insulators (송전용 자기애자의 수명 평가 연구)

  • Lee, Won-Kyo;Choi, In-Hyuk;Hwang, Kab-Cheol;Choi, Han-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.462-463
    • /
    • 2008
  • 36,000lbs porcelain insulators (D-1995, D-1997, D-2002) investigated mechanical and electrical qualities, which were installed in the Korea 154kV transmission lines. This paper assessed Weibull distribution function, quality index, and uniformity index to forecast the remaining life expectancies of insulators. Applying Weibull distribution function on year lapse change test, electro-mechanical failing load test, and HRB values confirmed a significant degree of correlation. Statistically calculating the life expectancy through quality indices for aging and new products and uniformity indices that are associated with uniformity of insulation materials revealed.

  • PDF

Temperature Uniformity of the Glass Panel Heated in the Infrared Heating Chamber

  • Lee, Kong-Hoon;Kim, Ook-Joong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.10
    • /
    • pp.1950-1956
    • /
    • 2005
  • An analysis has been carried out to investigate the effect of the reflectivity on the temperature distribution of a glass panel by infrared radiant heating. Halogen lamps are used to heat the panel, located near the top and bottom of the rectangular chamber. The thermal energy is transferred from the lamps to the panel only by radiation and it is considered by using view factor. The conductive transfer is limited inside the panel. The results show that the uniformity of the temperature distribution of the panel is improved and, at the same time, the time for heating increases as the wall reflectivity increases. The temperature difference between the center and the corner reaches a maximum in the early stage of the heating process and then decreases until it reaches a uniform steady-state value.

Analysis of the Illuminance Distribution on the Blackboard in Classroom of the Elementary and Senior (Junior) High School (초.중.고교의 흑판조도분포 분석)

  • Kim, Tae-Hyoun;Sun, Sang-Kweon;Park, Tong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1764-1766
    • /
    • 1997
  • In this paper, the illuminance distribution of blackboards on classroom in elementary, junior, and senior high school was measured and analyzed. Generally, average illuminance and uniformity of illuminance was 519[lx] and 0.543 (elementary: 389[lx], 0.387; junior: 632[lx], 0.570; senior: 527[lx], 0.608) respectively. When all lighting fixtures in each classroom were turned on, average illuminance was higher about 65% than lights-out, and, in case that local lighting fixtures exist, was higher 27% than absence, but uniformity of illuminance turned bad on the contrary ($0.462{\rightarrow}0.676$). According to classification into direction of windows on classroom. facing north, both were bad. In case of classroom to slant to east or west, the difference of illuminance at the forenoon and afternoon was big, and uniformity of illuminance was also bad.

  • PDF

Development of A Boom Sprayer for Effective Pest-and-Disease Control on Densed Paddy Stems (수도(水稻) 기부(基部) 방제용(防除用) 붐-형(型) 주간(株間) 살포(撒布) 장치(裝置) 개발(開發)에 관(關)한 연구(硏究))

  • Chung, Chang Joo;Chang, Young Chang
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.13-23
    • /
    • 1985
  • Spraying method from the paddy-field levee is known to give insufficient penetration of the spray droplets to the rice stem of the densely grown plants, which is generally encountered at the last stage of rice growth. This study was intended to investigate the spraying system to solve this existing problem. As an approach, it was attempted to develop the boom-with-nozzle, between-the-row application system. Several types of nozzles and their different arrangements in the boom were tested in the field to measure the penetration-reaching distance and the uniformity of spray droplet distribution. The results of the study are summarized as follows: 1. Field experiments by the spraying method from the paddy-field levee showed to have practically no penetration of the spray droplets to the portion of the plant stem with the normal flow volume generally applied and thus need for improving present spraying method. 2. It was found that, considering both the uniformity of the spray droplet distribution and performance rate, the most efficient type of nozzle in the between-the-row boom-type spraying system was one that has core-insert hollow-cone with some clearance between the cone and tip. 3. When tested by applying the spraying method of between-the-row, the nozzle pressure did not affect the uniformity of spray droplet distribution. However, the nozzle pressure had a positive effect on the penetrating-reaching distance of the facing side of the rice stem and did not affect much on that of the opposite face of the stem. It was also found that the maximum pressure to affect the penetration-reaching distance was about $10kg/cm^2$. 4. The uniformity of the spray droplet distribution in the between-the-row system was greatly affected by the height and orientation of the nozzles in the boom. Based on experimental work for the different type of the boom-with-nozzle arrangements, it is recommended that the position of nozzle is set at about 0.45 m above the ground and two nozzles in the boom are oriented to be faced with each other with some angle such that the droplet stream from the nozzle would not directly face with each other.

  • PDF

Basic RF Coils Used in Multi-channel RF Coil and Its B1 Field Distribution for Magnetic Resonance Imaging System (자기공명영상 촬영 장치에서 다채널 RF Coil에 이용되는 기본 구조 RF Coil의 B1 Field 분석)

  • Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4891-4895
    • /
    • 2010
  • RF coil is an important component of the Magnetic Resonance Imaging (MRI) system and the performance of RF coil is one of major factors for high SNR images. Sensitivity and RF field uniformity are parameters for evaluating RF coil performance. Since the B1 field is induced by RF coil, MR signal is strongly affected by RF coil structure and arrangement. In receiving MR signal, the RF coil sensitivity to MR Signal is also determined by the induced B1 field of RF coil. Therefore, the spatial distribution of B1 field must be verified. In this work, we performed computer simulation of the basic RF coil structures using Matlab and verified their sensitivity and uniformity through their B1 field distribution. This work will be useful for the advanced multi-channel RF coil design.