• Title/Summary/Keyword: Distribution safety

Search Result 3,059, Processing Time 0.031 seconds

Quality Changes of Fresh-Cut Leafy and Condiment Vegetables during Refrigerated Storage (신선편이 엽채류 및 조미채소류의 냉장저장 중 품질변화)

  • Kim, Su-Jin;Sun, Shih-Hui;Kim, Gi-Chang;Kim, Haeng-Ran;Yoon, Ki-Sun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.8
    • /
    • pp.1141-1149
    • /
    • 2011
  • The objective of this study was to analyze quality changes during storage of fresh-cut produce (leafy vegetables and condiment vegetables) as a function of packaging and storage temperature. Fresh-cut produce was washed using a three step cleaning process and was packed in vacuum packaging (green onion, hot pepper, onion, baechu) and perforated film packaging (buchu and perilla leaf). The effects of packaging method and storage temperature on quality of fresh-cut produce were determined by analyzing total plate counts, E. coli, coliform groups, moisture content, pH, Aw, surface color, and exterior quality during storage at 4 and 10$^{\circ}C$. According to the results, surface color change and microbial growth were delayed during storage at 4$^{\circ}C$. Additionally, E. coli was not detected during storage. Generally, moisture content decreased in the perforated film packaging. Changes in surface quality such as skin browning, softening of tissue and chlorosis at 4$^{\circ}C$ were inhibited, whereas rapid vacuum annealing and changes in color and flavor were observed in the sample stored at 10$^{\circ}C$. The result indicated that overall quality of the fresh-cut produce at 4$^{\circ}C$ was well maintained. The perforation in packing materials did not significantly increase the number of microorganisms on buchu and perilla leaf. The proper packaging methods and temperature may beneficial effect on microbial safety, quality and thus result in longer shelf-life fresh-cut vegetables during distribution.

Clinical Usefulness of a Totally Laparoscopic Gastrectomy (전(全)복강경하 위절제술의 임상적 유용성)

  • Kim, Jin-Jo;Kim, Sung-Keun;Jun, Kyong-Hwa;Kang, Han-Chul;Song, Kyo-Young;Chin, Hyung-Min;Kim, Wook;Jeon, Hae-Myung;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Park, Woo-Bae;Kim, Seung-Nam
    • Journal of Gastric Cancer
    • /
    • v.7 no.3
    • /
    • pp.132-138
    • /
    • 2007
  • Purpose: In Korea, the number of laparoscopy-assisted distal gastrectomies for early gastric cancer patients has been on the increase. Although minimally invasive surgery is more beneficial, no reported case of a total laparoscopic gastrectomy has been reported because of difficulty with intracorporeal anastomosis. This study attempts, through our experience, to determine the safety and feasibility of a total laparoscopic gastrectomy with various types of intracorporeal anastomosis using laparoscopic linears stapler in treating early gastric carcinomas. Materials and Methods: We investigated the surgical results and clinicopatholgical characteristics of 81 patients that underwent a totally laparoscopic distal gastrectomy at our department between June 2004 and May 2007. The intracorporeal anastomoses were performed by using laparoscopic linear staplers. Results: The mean operative time was 287 minutes, the mean anastomotic time was 40 minutes, and the mean number of laparoscopic linear staplers used for an operation was 7.5. The mean time to the first flatus, the first food intake, and discharge from hospital was 2.9, 3.6, and 10.3 days respectively. There were 11 cases of postoperative complications, but no case of postoperative mortality or conversion to an open procedure. In 75 patients with an adenocarcinoma, the mean number of lymph nodes harvested was 38.1 and the stage distribution was as follows: stage I, 72 patients; stage II, 2 patients; stage IV, 1 patient. During the mean follow-up period of 14 months, 5 patients died of other causes and there were no cases of cancer recurrence. Conclusion: A total laparoscopic gastrectomy with intracorporeal anastomosis by using a laparoscopic linear stapler was found to be safe and feasible. We were able to obtain acceptable surgical outcomes in terms of minimal invasiveness.

  • PDF

Pharmacokinetics of oxolinic acid in cultured olive flounder Paralichthys olivaceus by oral administration, injection and dipping (Oxolinic acid의 경구투여, 주사 및 약욕에 따른 넙치, Paralichthys olivaceus 체내 약물동태학적 특성)

  • Jung, Sung-Hee;Choi, Dong-Lim;Kim, Jin-Woo;Jo, Mi-Ra;Jee, Bo-Young;Seo, Jung-Soo
    • Journal of fish pathology
    • /
    • v.22 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • The pharmacokinetic properties of oxolinic acid (OA) were studied after oral administration, intraperitoneal injection and dipping to cultured olive flounder, Paralichthys olivaceus (average 90 g, $23{\pm}1{^{\circ}C}$). Plasma samples were taken at 3, 5, 10, 15, 24, 30, 48, 96 and 144 h post-dose. In oral dosage at 15, 30 and 60 ㎎/㎏, the peak plasma concentrations of OA, which attained at 10~15 h post-dose, were 1.92, 2.45 and 3.72 $\mu{g}/m\ell$, respectively. In intraperitoneal injection with 10 and 20 ㎎/㎏, the peak plasma concentrations of OA, which attained at 10 h post-dose, were 4.1 and 4.8 $\mu{g}/m\ell$, respectively. In dipping in 30 and 50 ppm for 1 h, peak concentrations were observed at 5 h and 30 h post-dose, were 0.22 and 0.38 $\mu{g}/m\ell$, respectively. The kinetic profile of absorption, distribution and elimination of OA in plasma were analyzed fitting to a one-compartment model by WinNonlin program. Calculated parameters for a single oral dosage of 15, 30 and 60 ㎎/㎏, respectively, were: AUC (the area under the concentration-time curve)=70.93, 120.0 and 141.86 $\mu{g}$ $h/m\ell$ $T_{max}$ (time for maximum concentration)=16.22, 20.39 and 17.33 h; $C_{max}$ (maximum concentration)=���D1.61, 2.40 and 3.01 $\mu{g}/m\ell$. Following intraperitoneal injection of 10 and 20 ㎎/㎏, these parameters were AUC=184.7 and 315.92 $\mu{g}$ $h/m\ell$ $T_{max}$=5.91 and 6.26 h; $C_{max}$=4.19 and 4.45 $\mu{g}/m\ell$. Following dipping at 30 and 50 ppm, these parameters were AUC=17.58 and 21.69 $\mu{g}$ $h/m\ell$ $T_{max}$=19.08 and 31.43 h; $C_{max}$x=0.22 and 0.25 $\mu{g}/m\ell$.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Calculation Method of Oil Slick Area on Sea Surface Using High-resolution Satellite Imagery: M/V Symphony Oil Spill Accident (고해상도 광학위성을 이용한 해상 유출유 면적 산출: 심포니호 기름유출 사고 사례)

  • Kim, Tae-Ho;Shin, Hye-Kyeong;Jang, So Yeong;Ryu, Joung-Mi;Kim, Pyeongjoong;Yang, Chan-Su
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1773-1784
    • /
    • 2021
  • In order to minimize damage to oil spill accidents in the ocean, it is essential to collect a spilled area as soon as possible. Thus satellite-based remote sensing is a powerful source to detect oil spills in the ocean. With the recent rapid increase in the number of available satellites, it has become possible to generate a status report of marine oil spills soon after the accident. In this study, the oil spill area was calculated using various satellite images for the Symphony oil spill accident that occurred off the coast of Qingdao Port, China, on April 27, 2021. In particular, improving the accuracy of oil spill area determination was applied using high-resolution commercial satellite images with a spatial resolution of 2m. Sentinel-1, Sentinel-2, LANDSAT-8, GEO-KOMPSAT-2B (GOCI-II) and Skysat satellite images were collected from April 27 to May 13, but five images were available considering the weather conditions. The spilled oil had spread northeastward, bound for coastal region of China. This trend was confirmed in the Skysat image and also similar to the movement prediction of oil particles from the accident location. From this result, the look-alike patch observed in the north area from the Sentinel-1A (2021.05.01) image was discriminated as a false alarm. Through the survey period, the spilled oil area tends to increase linearly after the accident. This study showed that high-resolution optical satellites can be used to calculate more accurately the distribution area of spilled oil and contribute to establishing efficient response strategies for oil spill accidents.

A study on the structure of the Three storied Stone pagoda in Gameunsa Temple site (감은사지 삼층석탑 구조)

  • Nam, si-jin
    • Korean Journal of Heritage: History & Science
    • /
    • v.38
    • /
    • pp.329-358
    • /
    • 2005
  • The Three storied Stone pagoda in Gameunsa Temple site, one of the early staged stone pagodas, has been known as a standard for Silla stone pagodas. A stone pagoda is not only a stone art work and but also a stone structure. Most studies and investigation of the stone pagoda has done mainly based on style and chronological research according to an art historical view. However, there is not an attempt to research the stone pagoda as a stone architecture. Most Korean experts at the stone pagoda has art history in their background. Engineers who can understand the structure of the stone pagoda are very limited. More architectural and engineering approach is need to research not only art historial understanding but also safety as a structure. We can find many technical know-how from our ancestors who made stone pagodas. 1. To reduce any deformation such as relaxation and sinking of BuJae which is caused by a heavy load, the BuJae (consist of a foundation stone and lower stereobates) should be enlarged. 2. A special construction method for connection between Myonsuk and Tangjoo was invented. This unique method is not used any longer after the Three storied Stone pagoda in Gameunsa Temple site. 3. The upper BuJae and the lower BuJae are missed each other by making a difference of Okgaesuk and Okgaebatchim in size. It is done for a distribution of perpendicular load and a prevention for relaxation of BuJae. 4. The center of gravity in the BuJae is located to the center of the stone pagoda by trimming the upper surface of the Okgaebatchim into a convex shape. The man who made stone pagodas had excellent knowledge on the engineering and techniques to understand the structure of the stone pagodas. We can confirm it as follows: the enlarged BuJae, dislocated connection between upper Bujae and lower BuJae, and moving the center of gravity close to the center of the stone pagoda.

Consideration of a Bacteria Contamination Management in the Dispensation of 99mTc Radiopharmaceutical (테크네슘 방사성의약품의 조제와 분배 과정에서 오염균에 대한 고찰)

  • Choi, Do Chul;Gim, Yeong Su;Jo, Gwang Mo;Gim, Hui Jeong;Seo, Han Gyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.84-87
    • /
    • 2018
  • Purpose The radiopharmaceutical used in the nuclear medicine department is used only for the specific patient according to the prescription or instruction of the doctor without selling, so it is dispensed and it is distributed and used for the examination. Radiopharmaceuticals administered to patients should be managed appropriately as well as radiation safety management during dispensation. The purpose of this study is to investigate microbial contamination during dispensation of radiopharmaceuticals Materials and Methods This study distinguished between general workbench and clean workbench and performed three tests. First, microbial cultivation test of radiopharmaceutical prepared and dispensed in general workbenches and sterile workbenches were carried out five times, respectively. The second test was performed settle plate method three times before and after the use of the exhaust filter. Finally, Adenosine Triphosphate (ATP) measurement was performed in each workbench to measure bacterial counts. In addition, ATP measurement were carried out by designating locations and items that may be contaminated during dispensation. Results In the microbial culture test, no microorganisms were detected in both samples. In the settle plate method, it was detected without using of the exhaust filter in a general workbench once. In the ATP measurement test, it was measured at the level of 400 RLU or less, which is the standard value of contamination, in both workbenches surface. In additional ATP measurement test, the refrigerator handle in the distribution room was measured above the reference value of 1217 RLU, the vacuum vial shield of the Tech Generator at 435 RLU, and the syringe holder at 1357 RLU. After environmental disinfection, the results were reduced to 311 RLU, 136 RLU, and 291 RLU. Conclusion No contamination by bacteria was found in both workbenches. However, microbial contamination may occur if the use of an exhaust filter or proper hand hygiene is not achieved. Regular inspections and management for aseptic processing themselves will be necessary.

Mechanism of steel pipe reinforcement grouting based on tunnel field measurement results (터널 현장 계측결과를 통한 강관보강 그라우팅의 거동 메커니즘)

  • Shin, Hyunkang;Jung, Hyuksang;Lee, Yong-joo;Kim, Nag-young;Ko, Sungil
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.3
    • /
    • pp.133-149
    • /
    • 2021
  • This study aims to report the behavioral mechanism of steel pipe reinforcement grouting, which is being actively used to ensure the stability of the excavation surface during tunnel excavation, based on measurements taken at the actual site. After using a 12 m steel pipe attached with a shape displacement meter and a strain gauge to reinforce the actual tunnel surface, behavioral characteristics were identified by analyzing the measured deformation and stress of the steel pipe. Taking into account that the steel pipes were overlapped every 6 m, the measured data up to 7 m of excavation were used. In addition, the behavioral characteristics of the steel pipe reinforcement according to the difference in strength were also examined by applying steel pipes with different allowable stresses (SGT275 and SGT550). As a result of analyzing the behavior of steel pipes for 7 hours after the first excavation for 1 m and before proceeding with the next excavation, the stress redistribution due to the arching effect caused by the excavation relaxation load was observed. As excavation proceeded by 1 m, the excavated section exhibited the greatest deformation during excavation of 4 to 6 m due to the stress distribution of the three-dimensional relaxation load, and deformation and stress were generated in the steel pipe installed in the ground ahead of the tunnel face. As a result of comparing the behavior of SGT275 steel pipe (yield strength 275 MPa) and SGT550 steel pipe (yield strength 550 MPa), the difference in the amount of deformation was up to 18 times and the stress was up to 12 times; the stronger the steel pipe, the better it was at responding to the relaxation load. In this study, the behavior mechanism of steel pipe reinforcement grouting in response to the arching effect due to the relaxation load was identified based on the measured data during the actual tunnel excavation, and the results were reported.

Cesium Sorption to Granite in An Anoxic Environment (무산소 환경에서의 화강암에 대한 세슘 수착 특성 연구)

  • Cho, Subin;Kwon, Kideok D.;Hyun, Sung Pil
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.2
    • /
    • pp.101-109
    • /
    • 2022
  • The mobility and transport of radioactive cesium are crucial factors to consider for the safety assessment of high-level radioactive waste disposal sites in granite. The retardation of radionuclides in the fractured crystalline rock is mainly controlled by the hydrochemical condition of groundwater and surface reactions with minerals present in the fractures. This paper reports the experimental results of cesium sorption to the Wonju Granite, a typical Mesozoic granite in Korea, performed in an anaerobic chamber that mimics the anoxic environment of a deep disposal site. We measured the rates and amounts of cesium (133Cs) removed by crushed granite samples in different electrolyte (NaCl, KCl, and CaCl2) solutions and a synthetic groundwater solution, with variations in the initial cesium concentration (10-5, 5×10-6, 10-6, 5×10-7 M). The cesium sorption kinetic and isotherm data were successfully simulated by the pseudo-second-order kinetic model (r2= 0.99) and the Freundlich isotherm model (r2= 0.99), respectively. The sorption distribution coefficient of granite increased almost linearly with increasing biotite content in granite samples, indicating that biotite is an effective cesium scavenger. The cesium removal was minimal in KCl solution compared to that in NaCl or CaCl2 solution, regardless of the ionic strength and initial cesium concentration that we examined, showing that K+ is the most competitive ion against cesium in sorption to granite. Because it is the main source mineral of K+ in fracture fluids, biotite may also hinder the sorption of cesium, which warrants further research.

A study on inspection methods for waste treatment facilities(II): Derivation of problems and improvement direction in inspection methods (폐기물처리시설의 세부검사방법 마련연구(II): 세부검사방법 문제점도출 및 개선방향 설정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.85-100
    • /
    • 2023
  • In this study, in order to improve the installation periodical inspection method of waste treatment facilities, we conducted on-site surveys of waste treatment facilities classified into six fields, grasped the problems of inspection methods, and made improvements accordingly. And revised the inspection method for waste treatment facilities. As a result, in the field of incineration and incineration heat recovery, inspection methods such as total temperature measurement and one-year TMS data comparison using a thermal imaging camera were established. And for the safety of the inspected person, it was applied so that the waste can be replaced with a document without opening it. In the case of landfill facilities, the details regarding the use of video information processing equipment and the management of facilities covering the upper part of the landfill facility are presented in the law, but the items that do not have a inspection methods were applied to the inspection method. In the case of Food Waste Treatment Facility, inspection methods were put in place to ensure compliance with standards for foul-smelling fish in odor control, a major cause of complaints. As a result, 10 out of 18 improvement proposals were reflected in the incineration and sterilization grinding, cement kiln, and incineration heat recovery facilities, and 11 out of 12 improvement proposals were reflected in the landfill facility. In the case of food distribution waste treatment facilities, 10 out of 12 improvement proposals were reflected, and a total of 31 inspection methods were improved.