• 제목/요약/키워드: Distribution diagram

검색결과 335건 처리시간 0.026초

배전선로 회선별단선도 자동생성 알고리즘 (An Auto-drawing Algorithm for the Single Line Diagram of Distribution Systems)

  • 손주환;임성일
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.854-859
    • /
    • 2010
  • Distribution Automation System(DAS) is designed to improve operational efficiency by acquisition and control of remote data using its components such as central computation units, communication network and feeder remote terminal units. A conventional human machine interface of the DAS adopts a schematic diagram which is made by drawing power equipments on the geographic information system map. The single line diagram is more useful than the schematic diagram for the main tasks of distribution system operation such as protective relay coordination, service restoration and loss minimization. Since the configuration of the distribution line is changed according to the relocation of the open tie switches, the auto-drawing algorithm based on the connection between the sections and the switches is an essential technique. This paper proposes a new auto-drawing algorithm for a single line diagram of distribution systems based on tertiary tree and collision avoidance method. The feasibility of the proposed algorithm has been testified for various cases using practical distribution system with 12 feeders.

New Definition of the Fibrogram and Its Application to Cotton Blending

  • Jeon, Boong-Soo
    • Fibers and Polymers
    • /
    • 제6권4호
    • /
    • pp.332-335
    • /
    • 2005
  • The fibrogram theory is newly derived from the superposition principle of the conventional staple diagram, in which the left-hand ends of the fibers have to share a common starting point in order for the fiber length distribution to be measured, and the right-hand ends of the fibers form points. It is shown that the fibrogram is the staple diagram of the fiber sample having different random starting points, as well as the double cumulative distribution function of the frequency length function in the length biased sample. Also, the various means, viz. the numerical mean length, numerical mean length in median, length biased mean length, and length biased mean length in median, and the various upper half means, viz. the numerical upper half mean length, numerical upper half mean length in median, length biased upper half mean length, and length biased upper half mean length in median, are discussed in relation to the cotton blending process.

배전자동화시스템의 효율적인 운용을 위한 구가기능 및 정보전송체계 (The Additional Functions and Data Transmission Flow Diagram for Effective Operation of Distribution Automation System)

  • 이중호;하복남;조남훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.211-213
    • /
    • 1998
  • This paper introduces the additional remote monitoring and remote setting functions needed to operate the distribution automation system effectively. we compare the additional functions with the old functions. The remote setting of minimum trip value of fault indicator is an example of additional function. It saves time and line-man's power. Also this paper describes the data transmission flow diagram for operation of distribution automation system using wireless communication method.

  • PDF

LH-모멘트의 적정 차수 결정에 의한 설계홍수량 추정 ( I ) (Estimation of Design Flood by the Determination of Best Fitting Order of LH-Moments ( I ))

  • 맹승진;이순혁
    • 한국농공학회지
    • /
    • 제44권6호
    • /
    • pp.49-60
    • /
    • 2002
  • This study was conducted to estimate the design flood by the determination of best fitting order of LH-moments of the annual maximum series at six and nine watersheds in Korea and Australia, respectively. Adequacy for flood flow data was confirmed by the tests of independence, homogeneity, and outliers. Gumbel (GUM), Generalized Extreme Value (GEV), Generalized Pareto (GPA), and Generalized Logistic (GLO) distributions were applied to get the best fitting frequency distribution for flood flow data. Theoretical bases of L, L1, L2, L3 and L4-moments were derived to estimate the parameters of 4 distributions. L, L1, L2, L3 and L4-moment ratio diagrams (LH-moments ratio diagram) were developed in this study. GEV distribution for the flood flow data of the applied watersheds was confirmed as the best one among others by the LH-moments ratio diagram and Kolmogorov-Smirnov test. Best fitting order of LH-moments will be derived by the confidence analysis of estimated design flood in the second report of this study.

시험탐사 결과에 따른 전기비저항 탐사 분석 (Resistivity Protecting analysis due to test survey result)

  • 김재홍;홍원표;박철숙;임은상
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1285-1289
    • /
    • 2008
  • Increasing the flood control capacity's link that is enforcing to existing dam by unusual change of weather, While build planing construction by exiting spillway of tunnel type to dam, could know that part bed rock is formed as is different with design. Grasped topography of research area and geology state to definite distribution aspect of different bed rock, Place that achieved Surface geological Survey and correct Survey is difficult in some section enforced Electrical resistivity dipole-dipole investigation. Grasped stratigraphy distribution confirmation and fracture or weathering zone making out siding 2D-Resistivity Electrical resistivity diagram and Reverse analysis diagram, examining closely soil weathered rock rock's distribution state, established stability countermeasure plan

  • PDF

Development of Fault Detector for Series Arc Fault in Low Voltage DC Distribution System using Wavelet Singular Value Decomposition and State Diagram

  • Oh, Yun-Sik;Han, Joon;Gwon, Gi-Hyeon;Kim, Doo-Ung;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.766-776
    • /
    • 2015
  • It is well known that series arc faults in Low Voltage DC (LVDC) distribution system occur at unintended points of discontinuity within an electrical circuit. These faults can make circuit breakers not respond timely due to low fault current. It, therefore, is needed to detect the series fault for protecting circuits from electrical fires. This paper proposes a novel scheme to detect the series arc fault using Wavelet Singular Value Decomposition (WSVD) and state diagram. In this paper, the fault detector developed is designed by using three criterion factors based on the RMS value of Singular value of Approximation (SA), Sum of the absolute value of Detail (SD), and state diagram. LVDC distribution system including AC/DC and DC/DC converter is modeled to verify the proposed scheme using ElectroMagnetic Transient Program (EMTP) software. EMTP/MODELS is also utilized to implement the series arc model and WSVD. Simulation results according to various conditions clearly show the effectiveness of the proposed scheme.

UN Studio의 공간 다이어그램 구성요소와 활용방법 분석 (A Study on the Analysis of Elements and Practical Using Method in Space Diagram of UN Studio)

  • 최은희;윤주현;권영걸
    • 디자인학연구
    • /
    • 제19권5호
    • /
    • pp.75-84
    • /
    • 2006
  • 본 연구의 주 내용은 UN Studio의 다이어그램 사례를 중점적으로 분석해봄으로써 공간디자인 다이어그램의 개념적 내용과 구성 요소 및 실질적 활용방법에 대해 알아보는 것이다. 사례연구를 통해 분석된 연구결과는 다음과 같다. 첫째, 공간 다이어그램에 표현되고 있는 개념적 내용은 모티브, 흐름, 관계, 분포의 네 가지로 구분된다. 둘째, 공간 다이어그램은 디자인 프로세스의 프로그램 개발, 개략적인 디자인, 초기 디자인의 단계에서 주로 사용된다. 셋째, 사례 다이어그램들에 기초한 다이어그램 구성요소의 내용은 크게 다섯 가지, 컨텍스트 분석, 객체 분석, 시간/행위 분석, 조형 분석, 공간 분석으로 나눌 수 있다. 넷째, 다이어그램의 실질적 활용에 있어서 모티브를 개념적으로 표현한 다이어그램은 조형 분석에 주로 활용될 수 있으며, 흐름을 개념적으로 표현한 다이어그램은 시간/행위 분석과 객체 분석에 주로 활용될 수 있다. 관계를 개념적으로 표현한 다이어그램은 공간 분석에 가장 많이 활용 될 수 있으며, 그 다음으로 컨텍스트 분석과 조형분석에 활용 될 수 있다. 분포를 개념적으로 표현한 다이어그램은 공간분석에 주로 활용될 수 있다. 이와 같은 연구 결과를 실무 및 교육의 디자인 프로젝트에 적극적으로 활용한다면 디자인 정오의 구조화뿐만 아니라 디자인 발상과 전개에 도움이 될 것이다.

  • PDF

힘다각형선도법을 이용한 세롤에 의한 파워스피닝공정의 해석 (Analysis of the Three-Roll Power Spinning Process by using the Method of Force Polygon Diagram)

  • 유동진
    • 한국정밀공학회지
    • /
    • 제2권3호
    • /
    • pp.47-58
    • /
    • 1985
  • The study is concerned with the analysis of the required loads and torque in the Three-Roll Power Spinning Process by using the Method of Force Polygon Diagram. Experiments are carried out using pure lead billets at room temperature. The radial force, the axial force and the torque occurring during the process are calculated theoretically and are compared with the experimental data. An approximate load distribution is known by the Force Polygon Diagram.

  • PDF

서비스 지향적 방법론 기반의 배전선로 회선별단선도 생성 기법 (Service Oriented Architecture based Single Line Diagram Auto-drawing Technique in Distribution Automation Systems)

  • 임성일
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.23-29
    • /
    • 2012
  • A single line diagram is a graphic user interface to represent electrical connectivity between power equipments in distribution automation systems. This paper proposes a new single line auto-drawing technique based on the service oriented architecture. Web service, CIM(Common Information Model) and SVG(Scalable Vector Graphics) are adopted to implement SOA concept. A web service demo system was established which is configured with the service provider, consumer and broker to verify the feasibility of this study.

멀티미디어 배전감시 제어시스템의 MMI 기술개발 (Development of MMI Techniques of the Power Distribution Control Systems for Multimedia Environment)

  • 이병철;정진현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1185-1187
    • /
    • 1998
  • The object of this study shows a program for supervisory control of the electric power distribution, approach to the more easy manipulations and hangulization that could be easily familiar to the domestic operators whereas the program, up to now, displayed only in English. This program is consist of a skeleton-diagram designer and a state-displayer of the electric power distribution To make skeleton-diagram data available in state-displayer, the designer must be performed with the proposed format in the program manual. States display executes downloading S/Ws-state-data externally and display the S/W informations at that times, and also power distribution simulation of voluntary S/W manipulations performed by the internal operators is possible.

  • PDF