• Title/Summary/Keyword: Distribution Department

Search Result 23,866, Processing Time 0.047 seconds

SAR Variation by EMI Paint Distribution on Front Case of Mobile Handsets

  • Lee Won Kew;Son Ji Myoung;Yang Woon Geun
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.339-342
    • /
    • 2004
  • In this paper, we investigated methods to reduce SAR(Specific Absorption Rate) value with EMI(Electromagnetic Interference) paint distribution on front case of mobile handset. Simulations for several different EMI patterns were carried out. For the purpose of modeling, we used 3 dimensional CAD(Computer Aided Design) program, `Pro-engineering'. SAR simulation was done with SEMCAD, simulation platform for electromagnetic compatibility antenna design and dosimetry. In order to distinguish the individual pieces and to enable an assignment of the different material properties, each subfile was imported separately. In simulation, folding angle was set to $142^{\circ}.$ If we vary folding angle, different SAR value will be obtained. Among the tested EMI paint patterns, the hairpin pattern showed the best performance, i.e. the decrease efficiency of $16.5\%$ and horizontal-direction zigzag pattern showed the decrease efficiency of $12.2\%$ when we set the completely removed pattern as reference.

  • PDF

On the maximum and minimum in a bivariate uniform distribution

  • Lee, Changsoo;Shin, Hyejung;Moon, Yeung-Gil
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.6
    • /
    • pp.1495-1500
    • /
    • 2015
  • We obtain means and variances of max {X, Y} and min {X, Y} in the underlying Morgenstern type bivariate uniform variables X and Y with same scale parameters and different scale parameters respectively. And we obtain the conditional expectations in the underlying Morgenstern type bivariate uniform variables. Here, we shall consider the conditional expectations to know the dependence of one variable on the other variable and we consider the behaviors of means and variances of max {X, Y} and min {X, Y} with respect to changes in means, variances, and the correlation coeffcient of the underlying Morgenstern type bivariate uniform variables.

Synthesis of Monodisperse Spherical SiO2 and Self-Assembly for Photonic Crystals

  • Lee, Byung-Kee;Jung, Young-Hwa;Kim, Do-Kyung
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.5
    • /
    • pp.472-477
    • /
    • 2009
  • Monodisperse spherical $SiO_2$ particles of various sizes ($\sim$350 nm and $\sim$800 nm) and size distributions were synthesized from TEOS and MTMS. The particle size and size distribution were controlled by changing the volume ratio of water to ethanol and the reaction temperature. Narrow-sized $SiO_2$ particles with $\sim$3% size distribution were obtained. Self-assembly of the $SiO_2$ particles for photonic crystals were performed by the solvent evaporation method. The number of ordered $SiO_2$ layers can be controlled by changing the amount of the dispersed $SiO_2$ volume fraction in the solvent.

A Study on Enhancement of Thermoelectric Cooling System Performance by Piezoelectric Actuator (압전 액츄에이터를 이용한 열전냉각 시스템 성능 향상에 관한 연구)

  • Yang, Ho-Dong;Yoon, Hee-Sung;Oh, Yool-Kwon
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.13-19
    • /
    • 2009
  • The thermoelectric cooling system consisted of the thermoelectric module, a heat sink and a cooling fan, respectively. Also, the piezoelectric actuator was applied to improve the performance of thermoelectric cooling system and investigate the heat transfer phenomenon. The temperature distribution of test section was measured to investigate cooling characteristics of thermoelectric cooling system. The flow phenomenon of test section was visualized using visualization device. When the piezoelectric actuator was applied to the heat transfer process of thermoelectric cooling system, acoustic streaming was occurred in test section. The acoustic streaming was occurred forced convection flow, and was regularly formed the temperature distribution in test section. The results clearly show that the acoustic streaming is one of the prime effects to enhance the convection heat transfer and can enhance the performance of thermoelectric cooling system.

An Interpretation of the Equations for the GI/GI/c/K Queue Length Distribution (GI/GI/c/K 대기행렬의 고객수 분포 방정식에 대한 해석)

  • Chae, Kyung-Chul;Kim, Nam-Ki;Choi, Dae-Won
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.28 no.4
    • /
    • pp.390-396
    • /
    • 2002
  • We present a meaningful interpretation of the equations for the steady-state queue length distribution of the GI/GI/c/K queue so that the equations are better understood and become more applicable. As a byproduct, we present an exact expression of the mean queue waiting time for the M/GI/c queue.

A study on the breakdown probability distribution of materials for conduction-cooled HTS SMES

  • Choi, J.H.;Kim, W.J.;Kim, H.J.;Seong, K.C.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.2
    • /
    • pp.17-20
    • /
    • 2011
  • Superconducting magnetic energy storage (SMES) has attracted a great deal of interest from the viewpoint of energy saving. The magnet of conduction-cooled high temperature superconducting (HTS) SMES is cooled down by a cryocooler. One of the most important problems to be assured the protection of magnet and cryocooler is breakdown at cryogenic temperature. In this study, we investigated insulation materials such as Kapton, Aluminum Nitride(AIN), Alumina($Al_2O_3$), glass fiber reinforced plastics(GFRP) and vacuum in cryogenic temperature. Also, we analyzed statistically the Weibull distribution of breakdown voltage.

Analytical solution for steady seepage and groundwater inflow into an underwater tunnel

  • Zou, Jin-feng;Wei, An;Liang, Li
    • Geomechanics and Engineering
    • /
    • v.20 no.3
    • /
    • pp.267-273
    • /
    • 2020
  • Solutions of the water pressure and groundwater inflow distribution along the tunnel perimeter in a half-infinite aquifer were investigated considering the conditions of the constant head and constant water pressure. It is assumed that the circular tunnel is buried in a fully saturated, homogeneous, isotropic and half-infinite space. Coordinate transformation technique was adopted, the problem of solving the control equations of water pressure in the Cartesian coordinate was transformed to that in the bipolar coordinate system, which can significantly simplify the derivation procedure of the water pressure and inflow distribution. The validation results show the accuracy and advantage of the proposed approach.

Optimal Burn-In under Warranty

  • Kim, Kui-Nam J.;Park, Chi-Yeon;Hong, Chan-Geui
    • Proceedings of the Safety Management and Science Conference
    • /
    • 1999.11a
    • /
    • pp.147-155
    • /
    • 1999
  • This paper discusses an optimal burn-in procedure to minimize total costs based on the assumption that the failure rate pattern follows a bimodal mixed Weibull distribution. The procedure will consider warranty period as a factor of the total expected burn-in cost. A cost model is formulated to find the optimal burn-in time that minimizes the expected burn-in cost. Conditional reliability for warranty period will be discussed. An illustrative example is included to show how to use the cost model in practice.

  • PDF

Optimal Burn-in Time under Cumulative Pro-Rata Replacement Warranty

  • Yun, Won-Young;Lee, Yang-Woo;Chung, Il-Han;Luis Ferreira
    • International Journal of Reliability and Applications
    • /
    • v.2 no.4
    • /
    • pp.241-251
    • /
    • 2001
  • In this paper, optimal bum-in time to minimize the total mean cost, which is the sum of manufacturing cost with burn-in and cumulative warranty-related cost, is obtained. When the products with cumulative pro-rata warranty have high failure rate in the early period (infant mortality period), a burn-in procedure is adopted to eliminate early product failures. After burn-in, the posterior product life distribution and the warranty-related cost are dependent on burn-in time; long burn-in period may reduce the warranty-related cost, but it increases the manufacturing cost. The paper provides a methodology to obtain total mean cost under burn-in and cumulative pro-rata warranty. Property of the optimal burn-in time is analyzed, and numerical examples and sensitivity analysis are studied.

  • PDF

Length-biased Rayleigh distribution: reliability analysis, estimation of the parameter, and applications

  • Kayid, M.;Alshingiti, Arwa M.;Aldossary, H.
    • International Journal of Reliability and Applications
    • /
    • v.14 no.1
    • /
    • pp.27-39
    • /
    • 2013
  • In this article, a new model based on the Rayleigh distribution is introduced. This model is useful and practical in physics, reliability, and life testing. The statistical and reliability properties of this model are presented, including moments, the hazard rate, the reversed hazard rate, and mean residual life functions, among others. In addition, it is shown that the distributions of the new model are ordered regarding the strongest likelihood ratio ordering. Four estimating methods, namely, method of moment, maximum likelihood method, Bayes estimation, and uniformly minimum variance unbiased, are used to estimate the parameters of this model. Simulation is used to calculate the estimates and to study their properties. Finally, the appropriateness of this model for real data sets is shown by using the chi-square goodness of fit test and the Kolmogorov-Smirnov statistic.

  • PDF